The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated...The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly.展开更多
In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of acti...In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of active power filters(APF).On the premise of proportional distribution of harmonic compensation capacity,the harmonic compensation rate of each APF is considered,and the harmonic current value of each APF to be compensated is obtained.At the same time,the communication topology is introduced.Each APF takes into account the compensation ability of other APFs.Finally,three APFs with different capacity and performance are configured at the harmonic source to suppress the same harmonic source,and the harmonic distortion rate is reduced to 1.73%.The simulation results show that the strategy can effectively improve the compensation capability of the multiple APF cascaded system to the power grid without increasing the installed capacity.展开更多
The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the det...The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the detecting circuits of an active power filter based on DSP control.We derived a mathematical model for the compensation error starting from the error estimation when a single distortion frequency is present.This model was then extended to the case where multiple frequencies are present in the distortion.A formula for a general theory of compensation error with fixed load and fixed lag time is presented.The theoretical analysis and experimental results show that the delay time of an active power filter mainly arises from the sampling time.Lower sampling frequencies introduce larger compensation errors in the active power filter reference current.展开更多
With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,a...With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,and interfering with the normal operation of the power grid.Based on the requirements of harmonic suppression and power system protection,a shunt active power filter(SAPF)is proposed as an effective harmonic suppression method.However,there are problems with impulse current and impulse voltage in the starting process of SAPF.Impulse current and impulse voltage cause the power grid and switchgear to bear greater current stress and voltage stress,which seriously affect the security and reliability of the power grid and may damage the switchgear.To effectively solve the problem of impulse current and impulse voltage,the starting process of SAPF is divided into the uncontrolled rectification stage and the transition stage.The mathematical model of the DC side of APF is established.The causes of impulse current and impulse voltage in the uncontrolled rectifier and transition phases are analyzed.By introducing voltage square,a new starting impulse suppression strategy of active power filter based on the slow rising curve is proposed,fundamentally solving the problems of impulse current and impulse voltage.Simulation results verify the effectiveness and feasibility of this method.展开更多
This paper addresses the principle and control topology of active pow er filter( APF). The control strategy of direct pow er control based on DC side is introduced,and the control output is implemented by using the pr...This paper addresses the principle and control topology of active pow er filter( APF). The control strategy of direct pow er control based on DC side is introduced,and the control output is implemented by using the principle of hysteresis control.The active pow er filter can effectively control the pow er system harmonics,improve the quality of electricity and purify pow er grid. The experimental results are provided to illustrate that the direct pow er control based on DC side has the advantages of simple structure,stable DC output voltage and fast dynamic response.展开更多
This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Opt...This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment.展开更多
This paper makes a technical analysis of the converter’s topologies that are conventionally employed in three-phase three-wire in increasing the power factor and harmonics eliminating,namely unit power factor(UPF)and...This paper makes a technical analysis of the converter’s topologies that are conventionally employed in three-phase three-wire in increasing the power factor and harmonics eliminating,namely unit power factor(UPF)and shunt active power filter(SAPF)and highlights the improvement of energy quality in the supply network.The paper highlights that the mathematical model of the three-phase PWM rectifier in the dq coordinate system is similar for both configurations.The structure of the control schemes of the two topologies for increasing the energy quality is similar by transformation of three-phase stationary coordinate system(a,b,c),to synchronous rotating(d,q)coordinate system that synchronously rotates with the fundamental voltage of the grid.Theoretical analysis and simulation results show that the control in synchronous rotating coordinate system has high power factor and low THDi for the both topologies.展开更多
In recent years, renewable energy resources are utilized to meet the growing energy demand. The integration of renewable energy resources with the grid incorporates power electronic converters for conversion of energy...In recent years, renewable energy resources are utilized to meet the growing energy demand. The integration of renewable energy resources with the grid incorporates power electronic converters for conversion of energy. These power electronic converters introduce power quality issues such as a harmonics, voltage regulation etc. Hence, to improve the power quality issues, this work proposes a new control strategy for a grid interconnected solar system. In this proposed work, a maximum power point tracking (MPPT) scheme has been used to obtain maximum power from the solar system and DC/DC converter is implemented to maintain a constant DC voltage. An active filtering method is utilized to improve the power quality of the grid connected solar system. The proposed system is validated through dynamic simulation using MATLAB/Simulink Power system toolbox and results are delivered to validate the effectiveness of the work.展开更多
Based on the background of achieving carbon peaking and carbon neutrality, the development and application of new high-power compressors, electric grid drilling RIGS and electric fracturing pump system provide new equ...Based on the background of achieving carbon peaking and carbon neutrality, the development and application of new high-power compressors, electric grid drilling RIGS and electric fracturing pump system provide new equipment support for the electric, green and intelligent development of shale gas fields in China. However, the harmonic pollution of shale gas grid becomes more serious due to the converter and frequency conversion device in the system, which easily causes harmonic resonance problem. Therefore, the harmonic resonance of shale gas grid is comprehensively analyzed and treated. Firstly, the working mechanism of compressor, electric drilling RIGS of the harmonic impedance model of electric fracturing pump system is established. Secondly, the main research methods of harmonic resonance analysis are introduced, and the basic principle of modal analysis is explained. Modal analysis method was used to analyze. Finally, harmonic resonance is suppressed. The results show that there may be multiple resonant frequency points in the distribution network changes, but these changes are relatively clear;if the original resonant frequency point of the resonant loop does not exist, the resonant frequency point disappears. The optimal configuration strategy of passive filter can effectively suppress harmonic resonance of distribution network in shale gas field.展开更多
This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In c...This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In comparison with the conventional solutions which are based on detecting the expected output R(s)and output C(s)to obtain error signal E(s),the measurement errors are eliminated even the error might be at a significant level.Moreover,it is possible that the individual debugging by regulating the coefficient K for every member of the multiple objectives achieves the optimization of the open loop gain.Therefore,this simple method can be applied to the weak coupling and multiple objectives system,which is usually controlled by complex controller.The principle of eliminating measurement errors is derived analytically,and the advantages comparing with the conventional solutions are depicted.Based on the SSEC method analysis,an application of this method for an active power filter(APF)is investigated and the effectiveness and viability of the scheme are demonstrated through the simulation and experimental verifications.展开更多
This paper proposes a novel AC filter system for a line commutated converter high voltage DC(LCC-HVDC)transmission system.Through the coordination of the hybrid active power filters(APF)and the existing reactive compe...This paper proposes a novel AC filter system for a line commutated converter high voltage DC(LCC-HVDC)transmission system.Through the coordination of the hybrid active power filters(APF)and the existing reactive compensation devices,the proposed filter system can not only enhance the suppression performance for LCC-HVDC harmonics,but also optimize the AC yard layout with reduced reactive power subbanks,reducing the cost of HVDC projects.The novel filter system adopts a serial passive resonance topology obtained by careful comparison of different APFs.A proper control scheme is then designed integrating the control strategy of the APF and impedance characteristics of the HVDC system,which is able to realize harmonic suppression and dynamic reactive power support simultaneously.In addition,a novel self-adaption digital low-pass filter algorithm is presented,which is used in the APF harmonic detecting step,enhancing both high precision and fast dynamic response.On the basis of a real HVDC project,the advantages of proposed filter system in harmonic suppression,reactive power regulation,and sub-banks reduction are simulated and demonstrated.展开更多
In order to eliminate the characteristic harmonics in high voltage direct current(HVDC)transmission systems and to simplify the analog controller structure,this paper proposes a new digital controller by adopting an a...In order to eliminate the characteristic harmonics in high voltage direct current(HVDC)transmission systems and to simplify the analog controller structure,this paper proposes a new digital controller by adopting an approximate inverse system control strategy according to the frequency response characteristic of the hybrid power filter.The pro-posed digital controller is implemented with a TMS320C32 DSP,including a series of parallel digital band-pass filters,phase shifters and amplifiers.The results of both simulations based on PSCAD and experiments on a 30 kVA HVDC system prove that the proposed digital control system is sta-ble and efficient for eliminating the harmonics.展开更多
基金supported in part by the National Key Research and Development Program of China(No.2017YFE0300104)in part by National Natural Science Foundation of China(No.51821005)。
文摘The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly.
基金This work was supported in part by the National Natural Science Foundation of China(Grant No.61863023).
文摘In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of active power filters(APF).On the premise of proportional distribution of harmonic compensation capacity,the harmonic compensation rate of each APF is considered,and the harmonic current value of each APF to be compensated is obtained.At the same time,the communication topology is introduced.Each APF takes into account the compensation ability of other APFs.Finally,three APFs with different capacity and performance are configured at the harmonic source to suppress the same harmonic source,and the harmonic distortion rate is reduced to 1.73%.The simulation results show that the strategy can effectively improve the compensation capability of the multiple APF cascaded system to the power grid without increasing the installed capacity.
基金provided by the National Basic Research Program of China (No.2005CB221505)
文摘The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the detecting circuits of an active power filter based on DSP control.We derived a mathematical model for the compensation error starting from the error estimation when a single distortion frequency is present.This model was then extended to the case where multiple frequencies are present in the distortion.A formula for a general theory of compensation error with fixed load and fixed lag time is presented.The theoretical analysis and experimental results show that the delay time of an active power filter mainly arises from the sampling time.Lower sampling frequencies introduce larger compensation errors in the active power filter reference current.
基金supported by the National Natural Science Foundation of China under Grant 61863023.
文摘With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,and interfering with the normal operation of the power grid.Based on the requirements of harmonic suppression and power system protection,a shunt active power filter(SAPF)is proposed as an effective harmonic suppression method.However,there are problems with impulse current and impulse voltage in the starting process of SAPF.Impulse current and impulse voltage cause the power grid and switchgear to bear greater current stress and voltage stress,which seriously affect the security and reliability of the power grid and may damage the switchgear.To effectively solve the problem of impulse current and impulse voltage,the starting process of SAPF is divided into the uncontrolled rectification stage and the transition stage.The mathematical model of the DC side of APF is established.The causes of impulse current and impulse voltage in the uncontrolled rectifier and transition phases are analyzed.By introducing voltage square,a new starting impulse suppression strategy of active power filter based on the slow rising curve is proposed,fundamentally solving the problems of impulse current and impulse voltage.Simulation results verify the effectiveness and feasibility of this method.
文摘This paper addresses the principle and control topology of active pow er filter( APF). The control strategy of direct pow er control based on DC side is introduced,and the control output is implemented by using the principle of hysteresis control.The active pow er filter can effectively control the pow er system harmonics,improve the quality of electricity and purify pow er grid. The experimental results are provided to illustrate that the direct pow er control based on DC side has the advantages of simple structure,stable DC output voltage and fast dynamic response.
文摘This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment.
文摘This paper makes a technical analysis of the converter’s topologies that are conventionally employed in three-phase three-wire in increasing the power factor and harmonics eliminating,namely unit power factor(UPF)and shunt active power filter(SAPF)and highlights the improvement of energy quality in the supply network.The paper highlights that the mathematical model of the three-phase PWM rectifier in the dq coordinate system is similar for both configurations.The structure of the control schemes of the two topologies for increasing the energy quality is similar by transformation of three-phase stationary coordinate system(a,b,c),to synchronous rotating(d,q)coordinate system that synchronously rotates with the fundamental voltage of the grid.Theoretical analysis and simulation results show that the control in synchronous rotating coordinate system has high power factor and low THDi for the both topologies.
文摘In recent years, renewable energy resources are utilized to meet the growing energy demand. The integration of renewable energy resources with the grid incorporates power electronic converters for conversion of energy. These power electronic converters introduce power quality issues such as a harmonics, voltage regulation etc. Hence, to improve the power quality issues, this work proposes a new control strategy for a grid interconnected solar system. In this proposed work, a maximum power point tracking (MPPT) scheme has been used to obtain maximum power from the solar system and DC/DC converter is implemented to maintain a constant DC voltage. An active filtering method is utilized to improve the power quality of the grid connected solar system. The proposed system is validated through dynamic simulation using MATLAB/Simulink Power system toolbox and results are delivered to validate the effectiveness of the work.
文摘Based on the background of achieving carbon peaking and carbon neutrality, the development and application of new high-power compressors, electric grid drilling RIGS and electric fracturing pump system provide new equipment support for the electric, green and intelligent development of shale gas fields in China. However, the harmonic pollution of shale gas grid becomes more serious due to the converter and frequency conversion device in the system, which easily causes harmonic resonance problem. Therefore, the harmonic resonance of shale gas grid is comprehensively analyzed and treated. Firstly, the working mechanism of compressor, electric drilling RIGS of the harmonic impedance model of electric fracturing pump system is established. Secondly, the main research methods of harmonic resonance analysis are introduced, and the basic principle of modal analysis is explained. Modal analysis method was used to analyze. Finally, harmonic resonance is suppressed. The results show that there may be multiple resonant frequency points in the distribution network changes, but these changes are relatively clear;if the original resonant frequency point of the resonant loop does not exist, the resonant frequency point disappears. The optimal configuration strategy of passive filter can effectively suppress harmonic resonance of distribution network in shale gas field.
基金National Natural Science Foundation of China(No.61273172)
文摘This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In comparison with the conventional solutions which are based on detecting the expected output R(s)and output C(s)to obtain error signal E(s),the measurement errors are eliminated even the error might be at a significant level.Moreover,it is possible that the individual debugging by regulating the coefficient K for every member of the multiple objectives achieves the optimization of the open loop gain.Therefore,this simple method can be applied to the weak coupling and multiple objectives system,which is usually controlled by complex controller.The principle of eliminating measurement errors is derived analytically,and the advantages comparing with the conventional solutions are depicted.Based on the SSEC method analysis,an application of this method for an active power filter(APF)is investigated and the effectiveness and viability of the scheme are demonstrated through the simulation and experimental verifications.
基金This work was supported in part by the National Natural Science Foundation of China(U1766210,51625702)Science and Technology Program of SGCC.
文摘This paper proposes a novel AC filter system for a line commutated converter high voltage DC(LCC-HVDC)transmission system.Through the coordination of the hybrid active power filters(APF)and the existing reactive compensation devices,the proposed filter system can not only enhance the suppression performance for LCC-HVDC harmonics,but also optimize the AC yard layout with reduced reactive power subbanks,reducing the cost of HVDC projects.The novel filter system adopts a serial passive resonance topology obtained by careful comparison of different APFs.A proper control scheme is then designed integrating the control strategy of the APF and impedance characteristics of the HVDC system,which is able to realize harmonic suppression and dynamic reactive power support simultaneously.In addition,a novel self-adaption digital low-pass filter algorithm is presented,which is used in the APF harmonic detecting step,enhancing both high precision and fast dynamic response.On the basis of a real HVDC project,the advantages of proposed filter system in harmonic suppression,reactive power regulation,and sub-banks reduction are simulated and demonstrated.
基金supported by the National Plan-ning Committee(No.2002064).
文摘In order to eliminate the characteristic harmonics in high voltage direct current(HVDC)transmission systems and to simplify the analog controller structure,this paper proposes a new digital controller by adopting an approximate inverse system control strategy according to the frequency response characteristic of the hybrid power filter.The pro-posed digital controller is implemented with a TMS320C32 DSP,including a series of parallel digital band-pass filters,phase shifters and amplifiers.The results of both simulations based on PSCAD and experiments on a 30 kVA HVDC system prove that the proposed digital control system is sta-ble and efficient for eliminating the harmonics.