This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si...This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.展开更多
AIM To establish minimum clinically important difference(MCID) for measurements in an orthopaedic patient population with joint disorders.METHODS Adult patients aged 18 years and older seeking care for joint condition...AIM To establish minimum clinically important difference(MCID) for measurements in an orthopaedic patient population with joint disorders.METHODS Adult patients aged 18 years and older seeking care for joint conditions at an orthopaedic clinic took the Patient-Reported Outcomes Measurement Information System Physical Function(PROMIS~? PF) computerized adaptive test(CAT), hip disability and osteoarthritis outcome score for joint reconstruction(HOOS JR), and the knee injury and osteoarthritis outcome score for joint reconstruction(KOOS JR) from February 2014 to April 2017. MCIDs were calculated using anchorbased and distribution-based methods. Patient reports of meaningful change in function since their first clinic encounter were used as an anchor.RESULTS There were 2226 patients who participated with a mean age of 61.16(SD = 12.84) years, 41.6% male, and 89.7% Caucasian. Mean change ranged from 7.29 to 8.41 for the PROMIS~? PF CAT, from 14.81 to 19.68 for the HOOS JR, and from 14.51 to 18.85 for the KOOS JR. ROC cut-offs ranged from 1.97-8.18 for the PF CAT, 6.33-43.36 for the HOOS JR, and 2.21-8.16 for the KOOS JR. Distribution-based methods estimated MCID values ranging from 2.45 to 21.55 for the PROMIS~? PF CAT; from 3.90 to 43.61 for the HOOS JR, and from 3.98 to 40.67 for the KOOS JR. The median MCID value in the range was similar to the mean change score for each measure and was 7.9 for the PF CAT, 18.0 for the HOOS JR, and 15.1 for the KOOS JR.CONCLUSION This is the first comprehensive study providing a wide range of MCIDs for the PROMIS? PF, HOOS JR, and KOOS JR in orthopaedic patients with joint ailments.展开更多
An experimentally feasible scheme for teleportation of an unknown two-atom entangled state is proposed. Our scheme uses a duster state as the quantum channel, where we do not need any joint Bell-state measurement. Mor...An experimentally feasible scheme for teleportation of an unknown two-atom entangled state is proposed. Our scheme uses a duster state as the quantum channel, where we do not need any joint Bell-state measurement. Moreover the successful probability and fidelity of teleportation can both reach 1.0. The current scheme can be realized within the current experimental technology.展开更多
This paper proposes a scheme for realizing entanglement swapping in cavity QED. The scheme is based on the resonant interaction of a two-mode cavity field with a ∧-type three-level atom. In contrast with the previous...This paper proposes a scheme for realizing entanglement swapping in cavity QED. The scheme is based on the resonant interaction of a two-mode cavity field with a ∧-type three-level atom. In contrast with the previously proposed schemes, the present scheme is ascendant, since the fidelity is 1.0 and the joint measurement isn't needed. And the scheme is experimentally feasible based on the current cavity QED technique.展开更多
In this paper, we reinvestigate the faithful quantum teleportation of an arbitrary two-qubit state by a multi-particle channel with multi-particle joint measurements. The relationship between multi-particle quantum ch...In this paper, we reinvestigate the faithful quantum teleportation of an arbitrary two-qubit state by a multi-particle channel with multi-particle joint measurements. The relationship between multi-particle quantum channel and the multi-particle joint measurement bases has been found. In addition, we show how to construct the multi-particle joint measurement bases.展开更多
International joint ventures (IJVs) have increasingly their role in business world and also in research field of international business. There have been a lot of studies related to determinant factors of IJV perform...International joint ventures (IJVs) have increasingly their role in business world and also in research field of international business. There have been a lot of studies related to determinant factors of IJV performance. However, there are very few studies focusing on the measurement of I Jr performance. Especially, researchers have ignored how foreign parent firms really choose their measures in the evaluation of their IJV performance. This research investigates determinant factors of performance measures of 1JVs. Determinant factors of IJV performance measures include motives for establishment, establishment mode, location of IJVs, distribution of ownership in IJVs, cultural background of parent firms, and trust between partners, IJV life stages, parent firms' international experience, and relatedness of the IJVs to their parents. Performance measures are divided into financial measures and non-financial measures. The paper shows how different determinant factors are expected to lead foreign parent firms preferring one kind of measure over the other.展开更多
Objective:To study the effect of repetitive peripheral magnetic stimulation(rPMS)combined with conventional rehabilitation measures on shoulder dysfunction in early stroke.Methods:60 patients with shoulder dysfunction...Objective:To study the effect of repetitive peripheral magnetic stimulation(rPMS)combined with conventional rehabilitation measures on shoulder dysfunction in early stroke.Methods:60 patients with shoulder dysfunction in early stroke were selected,and all of them were admitted to our hospital from August 2021 to August 2023.The patients were randomly grouped into a control group(conventional rehabilitation measures intervention,30 cases)and an intervention group(rPMS and conventional rehabilitation measures intervention,30 cases)according to the lottery method.The pain scores,shoulder mobility,and motor function scores of the two groups were compared.Results:The pain score was lower in the intervention group,and the shoulder mobility and motor function scores were higher in the intervention group(P<0.05)as compared to that of the control group.Conclusion:The effect of combining rPMS and conventional rehabilitation measures in treating shoulder dysfunction in early stroke was remarkable and should be popularized.展开更多
In the tracking problem for the maritime radiation source by a passive sensor,there are three main difficulties,i.e.,the poor observability of the radiation source,the detection uncertainty(false and missed detections...In the tracking problem for the maritime radiation source by a passive sensor,there are three main difficulties,i.e.,the poor observability of the radiation source,the detection uncertainty(false and missed detections)and the uncertainty of the target appearing/disappearing in the field of view.These difficulties can make the establishment or maintenance of the radiation source target track invalid.By incorporating the elevation information of the passive sensor into the automatic bearings-only tracking(BOT)and consolidating these uncertainties under the framework of random finite set(RFS),a novel approach for tracking maritime radiation source target with intermittent measurement was proposed.Under the RFS framework,the target state was represented as a set that can take on either an empty set or a singleton; meanwhile,the measurement uncertainty was modeled as a Bernoulli random finite set.Moreover,the elevation information of the sensor platform was introduced to ensure observability of passive measurements and obtain the unique target localization.Simulation experiments verify the validity of the proposed approach for tracking maritime radiation source and demonstrate the superiority of the proposed approach in comparison with the traditional integrated probabilistic data association(IPDA)method.The tracking performance under different conditions,particularly involving different existence probabilities and different appearance durations of the target,indicates that the method to solve our problem is robust and effective.展开更多
In this paper, to meet the needs of studying work of dynamic mechanical properties of welded joint, the dynamic mechanical properties of welded joint were measured by means of SHPB(Split Hopkinson Pressure Bar).The dy...In this paper, to meet the needs of studying work of dynamic mechanical properties of welded joint, the dynamic mechanical properties of welded joint were measured by means of SHPB(Split Hopkinson Pressure Bar).The dynamic mechanical property's curves of every part of welded joint were obtained. For studying the dynamic behavior of mechanical heterogeneity of welded joint, important data were offered. The method of test creates a new way of studying dynamic mechanical properties of welded joint.展开更多
Magnesium diboride(MgB_(2))magnets have the potential to be the next-generation liquid-helium-free magnet for magnetic resonance imaging(MRI)application due to their relatively high superconducting transition temperat...Magnesium diboride(MgB_(2))magnets have the potential to be the next-generation liquid-helium-free magnet for magnetic resonance imaging(MRI)application due to their relatively high superconducting transition temperature,high current density and low raw material cost compared with current commercial niobium-titanium(Nb-Ti)magnets.A typical superconducting magnet includes several coils.To produce an ultra-stable magnetic field for imaging in MRI,a superconducting electromagnet operating in a persistent mode is crucial.Superconducting coils of the electromagnet in MRI are short-circuited to operate in the persistent mode by connecting coils with superconducting joints.Per-sistent joints have been demonstrated for in-situ and ex-situ wires of both mono-and multi-filamentary structures,made predominantly by PIT techniques similar to those used in wire production.To realise further engagement of MgB_(2)in MRI applications,enhancing the performance of MgB_(2)superconducting joints is essential.This literature review summarises research and development on MgB_(2)superconducting joining technology.展开更多
In order to solve the problem that the traditional space jamming countermeasure cannot deal with the mainlobe self-protecting jammings,a polarization-space joint mainlobe jamming countermeasure technique based on divi...In order to solve the problem that the traditional space jamming countermeasure cannot deal with the mainlobe self-protecting jammings,a polarization-space joint mainlobe jamming countermeasure technique based on divided dimensions is proposed.Specifically,the digital beam of each row and column is firstly formed by using dual polarization digital receiving in multi-channel.Then,the polarization-space joint cancellation in both azimuth and elevation dimensions is carried out based on the polarization-space joint difference between the target echo and the jamming,as well as the divided dimension feature of the row and column beams.Finally,the sum and difference beams of the full array in the elevation or azimuth dimension are formed by the beams after jamming cancelling,and the monopulse angle measurement is further employed to obtain target angles.The effectiveness of the proposed technique is verified by simulations,indicating that the self-protecting jamming and multiple mainlobe following jammings can be both cancelled simultaneously with the angle measurement unchanged.展开更多
Using computer-controlled liquid crystal display (LCD) as an image processor and a CCD camera as a detector, phase-only correlation measurement is performed with the aid of joint transform correlation method (JTC). Th...Using computer-controlled liquid crystal display (LCD) as an image processor and a CCD camera as a detector, phase-only correlation measurement is performed with the aid of joint transform correlation method (JTC). This computer -controlled LCD-CCD image processing system may be a powerful tool for defect detection, position control and pattern recognition. It enables new possibilities in analog real-time image processing. This is of great interest in microelectronic manufacturing today and in the future.展开更多
Each rock joint is unique by nature which means that utilization of replicas in direct shear tests is required in experimental parameter studies.However,a method to acquire knowledge about the ability of the replicas ...Each rock joint is unique by nature which means that utilization of replicas in direct shear tests is required in experimental parameter studies.However,a method to acquire knowledge about the ability of the replicas to imitate the shear mechanical behavior of the rock joint and their dispersion in direct shear testing is lacking.In this study,a novel method is presented for geometric quality assurance of replicas.The aim is to facilitate generation of high-quality direct shear testing data as a prerequisite for reliable subsequent analyses of the results.In Part 1 of this study,two quality assurance parameters,smf and V_(Hp100),are derived and their usefulness for evaluation of geometric deviations,i.e.geometric reproducibility,is shown.In Part 2,the parameters are validated by showing a correlation between the parameters and the shear mechanical behavior,which qualifies the parameters for usage in the quality assurance method.Unique results from direct shear tests presenting comparisons between replicas and the rock joint show that replicas fulfilling proposed threshold values of σ_(mf)<0.06 mm and|V_(Hp100)|<0.2 mm have a narrow dispersion and imitate the shear mechanical behavior of the rock joint in all aspects apart from having a slightly lower peak shear strength.The wear in these replicas,which have similar morphology as the rock joint,is in the same areas as in the rock joint.The wear is slightly larger in the rock joint and therefore the discrepancy in peak shear strength derives from differences in material properties,possibly from differences in toughness.It is shown by application of the suggested method that the quality assured replicas manufactured following the process employed in this study phenomenologically capture the shear strength characteristics,which makes them useful in parameter studies.展开更多
基金supported by the National Key R&D Program(No.2022YFA1602201)。
文摘This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.
基金National Institute of Arthritis and Musculoskeletal and Skin Diseases of the National Institutes of Health,No.U01AR067138.
文摘AIM To establish minimum clinically important difference(MCID) for measurements in an orthopaedic patient population with joint disorders.METHODS Adult patients aged 18 years and older seeking care for joint conditions at an orthopaedic clinic took the Patient-Reported Outcomes Measurement Information System Physical Function(PROMIS~? PF) computerized adaptive test(CAT), hip disability and osteoarthritis outcome score for joint reconstruction(HOOS JR), and the knee injury and osteoarthritis outcome score for joint reconstruction(KOOS JR) from February 2014 to April 2017. MCIDs were calculated using anchorbased and distribution-based methods. Patient reports of meaningful change in function since their first clinic encounter were used as an anchor.RESULTS There were 2226 patients who participated with a mean age of 61.16(SD = 12.84) years, 41.6% male, and 89.7% Caucasian. Mean change ranged from 7.29 to 8.41 for the PROMIS~? PF CAT, from 14.81 to 19.68 for the HOOS JR, and from 14.51 to 18.85 for the KOOS JR. ROC cut-offs ranged from 1.97-8.18 for the PF CAT, 6.33-43.36 for the HOOS JR, and 2.21-8.16 for the KOOS JR. Distribution-based methods estimated MCID values ranging from 2.45 to 21.55 for the PROMIS~? PF CAT; from 3.90 to 43.61 for the HOOS JR, and from 3.98 to 40.67 for the KOOS JR. The median MCID value in the range was similar to the mean change score for each measure and was 7.9 for the PF CAT, 18.0 for the HOOS JR, and 15.1 for the KOOS JR.CONCLUSION This is the first comprehensive study providing a wide range of MCIDs for the PROMIS? PF, HOOS JR, and KOOS JR in orthopaedic patients with joint ailments.
基金National Natural Science Foundation of China under Grant Nos.60678022 and 1070400the Specialized Research Fund for the Doctoral Program of Higher Education of China under Grant No.20060357008+3 种基金Natural Science Foundation of Anhui Province under Grant No.070412060the Key Program of the Education Department of Anhui Province under Grant No.2006KJ070AThe Talent Foundation of Anhui UniversityAnhui Key Laboratory of Information Materials and Devices (Anhui University)
文摘An experimentally feasible scheme for teleportation of an unknown two-atom entangled state is proposed. Our scheme uses a duster state as the quantum channel, where we do not need any joint Bell-state measurement. Moreover the successful probability and fidelity of teleportation can both reach 1.0. The current scheme can be realized within the current experimental technology.
基金Project supported by the National Natural Science Foundation of China (Grant No 10574022), the Funds of the Natural Science of Fujian Province, China (Grant No Z0512006).
文摘This paper proposes a scheme for realizing entanglement swapping in cavity QED. The scheme is based on the resonant interaction of a two-mode cavity field with a ∧-type three-level atom. In contrast with the previously proposed schemes, the present scheme is ascendant, since the fidelity is 1.0 and the joint measurement isn't needed. And the scheme is experimentally feasible based on the current cavity QED technique.
基金National Natural Science Foundation of China under Grant Nos.60578014 and 10547106
文摘In this paper, we reinvestigate the faithful quantum teleportation of an arbitrary two-qubit state by a multi-particle channel with multi-particle joint measurements. The relationship between multi-particle quantum channel and the multi-particle joint measurement bases has been found. In addition, we show how to construct the multi-particle joint measurement bases.
文摘International joint ventures (IJVs) have increasingly their role in business world and also in research field of international business. There have been a lot of studies related to determinant factors of IJV performance. However, there are very few studies focusing on the measurement of I Jr performance. Especially, researchers have ignored how foreign parent firms really choose their measures in the evaluation of their IJV performance. This research investigates determinant factors of performance measures of 1JVs. Determinant factors of IJV performance measures include motives for establishment, establishment mode, location of IJVs, distribution of ownership in IJVs, cultural background of parent firms, and trust between partners, IJV life stages, parent firms' international experience, and relatedness of the IJVs to their parents. Performance measures are divided into financial measures and non-financial measures. The paper shows how different determinant factors are expected to lead foreign parent firms preferring one kind of measure over the other.
文摘Objective:To study the effect of repetitive peripheral magnetic stimulation(rPMS)combined with conventional rehabilitation measures on shoulder dysfunction in early stroke.Methods:60 patients with shoulder dysfunction in early stroke were selected,and all of them were admitted to our hospital from August 2021 to August 2023.The patients were randomly grouped into a control group(conventional rehabilitation measures intervention,30 cases)and an intervention group(rPMS and conventional rehabilitation measures intervention,30 cases)according to the lottery method.The pain scores,shoulder mobility,and motor function scores of the two groups were compared.Results:The pain score was lower in the intervention group,and the shoulder mobility and motor function scores were higher in the intervention group(P<0.05)as compared to that of the control group.Conclusion:The effect of combining rPMS and conventional rehabilitation measures in treating shoulder dysfunction in early stroke was remarkable and should be popularized.
基金Project(61101186)supported by the National Natural Science Foundation of China
文摘In the tracking problem for the maritime radiation source by a passive sensor,there are three main difficulties,i.e.,the poor observability of the radiation source,the detection uncertainty(false and missed detections)and the uncertainty of the target appearing/disappearing in the field of view.These difficulties can make the establishment or maintenance of the radiation source target track invalid.By incorporating the elevation information of the passive sensor into the automatic bearings-only tracking(BOT)and consolidating these uncertainties under the framework of random finite set(RFS),a novel approach for tracking maritime radiation source target with intermittent measurement was proposed.Under the RFS framework,the target state was represented as a set that can take on either an empty set or a singleton; meanwhile,the measurement uncertainty was modeled as a Bernoulli random finite set.Moreover,the elevation information of the sensor platform was introduced to ensure observability of passive measurements and obtain the unique target localization.Simulation experiments verify the validity of the proposed approach for tracking maritime radiation source and demonstrate the superiority of the proposed approach in comparison with the traditional integrated probabilistic data association(IPDA)method.The tracking performance under different conditions,particularly involving different existence probabilities and different appearance durations of the target,indicates that the method to solve our problem is robust and effective.
文摘In this paper, to meet the needs of studying work of dynamic mechanical properties of welded joint, the dynamic mechanical properties of welded joint were measured by means of SHPB(Split Hopkinson Pressure Bar).The dynamic mechanical property's curves of every part of welded joint were obtained. For studying the dynamic behavior of mechanical heterogeneity of welded joint, important data were offered. The method of test creates a new way of studying dynamic mechanical properties of welded joint.
基金thankful for the support from the Australian Research Council(ARC)Linkage Project(LP200200689).
文摘Magnesium diboride(MgB_(2))magnets have the potential to be the next-generation liquid-helium-free magnet for magnetic resonance imaging(MRI)application due to their relatively high superconducting transition temperature,high current density and low raw material cost compared with current commercial niobium-titanium(Nb-Ti)magnets.A typical superconducting magnet includes several coils.To produce an ultra-stable magnetic field for imaging in MRI,a superconducting electromagnet operating in a persistent mode is crucial.Superconducting coils of the electromagnet in MRI are short-circuited to operate in the persistent mode by connecting coils with superconducting joints.Per-sistent joints have been demonstrated for in-situ and ex-situ wires of both mono-and multi-filamentary structures,made predominantly by PIT techniques similar to those used in wire production.To realise further engagement of MgB_(2)in MRI applications,enhancing the performance of MgB_(2)superconducting joints is essential.This literature review summarises research and development on MgB_(2)superconducting joining technology.
文摘In order to solve the problem that the traditional space jamming countermeasure cannot deal with the mainlobe self-protecting jammings,a polarization-space joint mainlobe jamming countermeasure technique based on divided dimensions is proposed.Specifically,the digital beam of each row and column is firstly formed by using dual polarization digital receiving in multi-channel.Then,the polarization-space joint cancellation in both azimuth and elevation dimensions is carried out based on the polarization-space joint difference between the target echo and the jamming,as well as the divided dimension feature of the row and column beams.Finally,the sum and difference beams of the full array in the elevation or azimuth dimension are formed by the beams after jamming cancelling,and the monopulse angle measurement is further employed to obtain target angles.The effectiveness of the proposed technique is verified by simulations,indicating that the self-protecting jamming and multiple mainlobe following jammings can be both cancelled simultaneously with the angle measurement unchanged.
基金National Studying Abroad Foundation Management Commission of China!(No. 98822014)
文摘Using computer-controlled liquid crystal display (LCD) as an image processor and a CCD camera as a detector, phase-only correlation measurement is performed with the aid of joint transform correlation method (JTC). This computer -controlled LCD-CCD image processing system may be a powerful tool for defect detection, position control and pattern recognition. It enables new possibilities in analog real-time image processing. This is of great interest in microelectronic manufacturing today and in the future.
文摘Each rock joint is unique by nature which means that utilization of replicas in direct shear tests is required in experimental parameter studies.However,a method to acquire knowledge about the ability of the replicas to imitate the shear mechanical behavior of the rock joint and their dispersion in direct shear testing is lacking.In this study,a novel method is presented for geometric quality assurance of replicas.The aim is to facilitate generation of high-quality direct shear testing data as a prerequisite for reliable subsequent analyses of the results.In Part 1 of this study,two quality assurance parameters,smf and V_(Hp100),are derived and their usefulness for evaluation of geometric deviations,i.e.geometric reproducibility,is shown.In Part 2,the parameters are validated by showing a correlation between the parameters and the shear mechanical behavior,which qualifies the parameters for usage in the quality assurance method.Unique results from direct shear tests presenting comparisons between replicas and the rock joint show that replicas fulfilling proposed threshold values of σ_(mf)<0.06 mm and|V_(Hp100)|<0.2 mm have a narrow dispersion and imitate the shear mechanical behavior of the rock joint in all aspects apart from having a slightly lower peak shear strength.The wear in these replicas,which have similar morphology as the rock joint,is in the same areas as in the rock joint.The wear is slightly larger in the rock joint and therefore the discrepancy in peak shear strength derives from differences in material properties,possibly from differences in toughness.It is shown by application of the suggested method that the quality assured replicas manufactured following the process employed in this study phenomenologically capture the shear strength characteristics,which makes them useful in parameter studies.