The distribution of magnetic forces and current on sheet and coil was analyzed in detail according to the structural parameter of the coil which was invalid.The result shows that the current direction based on simulat...The distribution of magnetic forces and current on sheet and coil was analyzed in detail according to the structural parameter of the coil which was invalid.The result shows that the current direction based on simulation result agrees with the principles of uniform pressure electromagnetic actuator.The reason for coil failure was proposed.Then the magnetic forces on the sheet were input into an explicit finite element software ANSYS/LS-DYNA to analyze the deformation law of the sheet.展开更多
Plasma synthetic jet actuator(PSJA) has a wide application prospect in the high-speed flow control field for its high jet velocity.In this paper,the influence of the air pressure on the performance of a two-electrod...Plasma synthetic jet actuator(PSJA) has a wide application prospect in the high-speed flow control field for its high jet velocity.In this paper,the influence of the air pressure on the performance of a two-electrode PSJA is investigated by the schlieren method in a large range from 7 k Pa to 100 k Pa.The energy consumed by the PSJA is roughly the same for all the pressure levels.Traces of the precursor shock wave velocity and the jet front velocity vary a lot for different pressures.The precursor shock wave velocity first decreases gradually and then remains at 345 m/s as the air pressure increases.The peak jet front velocity always appears at the first appearance of a jet,and it decreases gradually with the increase of the air pressure.A maximum precursor shock wave velocity of 520 m/s and a maximum jet front velocity of 440 m/s are observed at the pressure of 7 k Pa.The averaged jet velocity in one period ranges from 44 m/s to 54 m/s for all air pressures,and it drops with the rising of the air pressure.High velocities of the precursor shock wave and the jet front indicate that this type of PSJA can still be used to influence the high-speed flow field at 7 k Pa.展开更多
基金Project (50875093) supported by the National Natural Science Foundation of China
文摘The distribution of magnetic forces and current on sheet and coil was analyzed in detail according to the structural parameter of the coil which was invalid.The result shows that the current direction based on simulation result agrees with the principles of uniform pressure electromagnetic actuator.The reason for coil failure was proposed.Then the magnetic forces on the sheet were input into an explicit finite element software ANSYS/LS-DYNA to analyze the deformation law of the sheet.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51407197,51522606,51336011,91541120,and 11472306)
文摘Plasma synthetic jet actuator(PSJA) has a wide application prospect in the high-speed flow control field for its high jet velocity.In this paper,the influence of the air pressure on the performance of a two-electrode PSJA is investigated by the schlieren method in a large range from 7 k Pa to 100 k Pa.The energy consumed by the PSJA is roughly the same for all the pressure levels.Traces of the precursor shock wave velocity and the jet front velocity vary a lot for different pressures.The precursor shock wave velocity first decreases gradually and then remains at 345 m/s as the air pressure increases.The peak jet front velocity always appears at the first appearance of a jet,and it decreases gradually with the increase of the air pressure.A maximum precursor shock wave velocity of 520 m/s and a maximum jet front velocity of 440 m/s are observed at the pressure of 7 k Pa.The averaged jet velocity in one period ranges from 44 m/s to 54 m/s for all air pressures,and it drops with the rising of the air pressure.High velocities of the precursor shock wave and the jet front indicate that this type of PSJA can still be used to influence the high-speed flow field at 7 k Pa.