期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Research on magnetic centermeasurement of quadrupole and sextupole using vibrating wire alignment technique in HEPS-TF
1
作者 Lei Wu Xiao-long Wang +4 位作者 Chun-hua Li Hua-min Qu Zi-hao Wang Min-xian Li Ling-ling Gong 《Radiation Detection Technology and Methods》 2018年第2期140-147,共8页
Purpose In order to meet the extremely low emittance requirement,the magnets in the storage ring of high-energy photon source(HEPS)need to have a stable support and precise positioning.In HEPS-TF,the key and difficult... Purpose In order to meet the extremely low emittance requirement,the magnets in the storage ring of high-energy photon source(HEPS)need to have a stable support and precise positioning.In HEPS-TF,the key and difficult technologies of HEPS should be researched and developed.Vibrating wire alignment technique is one important project of HEPS-TF.It can be used to pre-align the quadrupoles and sextupoles on one girder with high precision.A vibrating wire measurement system was set up and tested to verify the magnetic center measurement precision and the magnet adjustment error.Methods There are one sextupole and one quadrupole installed on a multipole girder.Vibrating wire is stretched through mechanical center of the magnet apertures and supported by the test benches on the two sides.A single conducting wire is stretched through themagnet aperture and electrified by alternating current.The wire will vibrate for a period of Lorentz force.By matching the current frequency to one mode of natural frequency of the wire,the vibrating amplitude will be enhanced.And by measuring the vibrating amplitude,the magnetic field at the wire position can be got.Moving the wire across the magnet aperture in the transversal or vertical direction,the distribution of magnetic field and magnetic center position can be measured.According to the magnetic center position error to adjust the magnet.Measure the magnetic center of all magnets installed on the multipole girder one by one,and adjust their magnetic center to a line.Results The magnetic center measurement precision is better than±3μm,and the magnet adjustment error is less than 6μm.Conclusion The vibrating wire system design and a series of magnetic center measurement experiments have gained good achievements.It has been proved the vibrating wire system is designed reasonable and using the vibrating wire to align the magnets installed on a multipole girder is feasible and can reach a high precision. 展开更多
关键词 Vibrating wire magnetic center Measurement precision Magnet adjustment
原文传递
Design of the longitudinal-gradient dipole magnets for HEPS
2
作者 Qing Li Fusan Chen +1 位作者 Chunhua Li Minxian Li 《Radiation Detection Technology and Methods》 CSCD 2021年第1期1-7,共7页
TheHigh Energy Photon Source(HEPS)is the fourth generation light source with high brilliance and lowemittance.The lattice of the storage ring consists of five different dipoles with longitudinal gradients.The longitud... TheHigh Energy Photon Source(HEPS)is the fourth generation light source with high brilliance and lowemittance.The lattice of the storage ring consists of five different dipoles with longitudinal gradients.The longitudinal-gradient dipoles(BLGs)are permanent magnets.This paper presents the construction of BLGs and the magnetic field results using OPERA3D.By optimizing the shape of the polar surface,the magnetic field uniformity is optimized to about 2×10−4.With some adjustable screws,the magnetic field is controlled accurately.Some temperature compensation shunt sheets are arranged to make the temperature stability of magnets better than±50 ppm/°C.At last,the mechanical tolerances of the magnets are studied. 展开更多
关键词 Longitudinal-gradient dipoles Permanent magnets design adjustable magnets Temperature compensation‚mechanical tolerances
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部