The biological aerated filter (BAF) was used to treat the oil-field produced water. The removal efficiency for oil, COD, BOD and suspended solids (SS) was 76.3%-80.3%, 31.6%-57.9%, 8.6.3%-96.3% and76.4%--82.7%, re...The biological aerated filter (BAF) was used to treat the oil-field produced water. The removal efficiency for oil, COD, BOD and suspended solids (SS) was 76.3%-80.3%, 31.6%-57.9%, 8.6.3%-96.3% and76.4%--82.7%, respectively when the hydraulic loading rates varied from 016m·h^-1 to 1.4m·h^-1. The greatest partof removal, for example more than 80% of COD removal, occurred on the top 100cm of the media in BAF. The kinetic .performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loadingrates, in biological aerated filters could be described by c1/c1=l-exp(-2.44/L^0.59). This equation could be used topredict the B OD.removal efficiency at different hydraulic loading rates.展开更多
The slightly polluted wastewater from oil refinery contains some COD, oil pollutants and suspended solids (SS). A small-scale fixed film biological aerated filter (BAF) process was used to treat the wastewater. Th...The slightly polluted wastewater from oil refinery contains some COD, oil pollutants and suspended solids (SS). A small-scale fixed film biological aerated filter (BAF) process was used to treat the wastewater. The influences of hydraulic retention time (HRT), air/water volume flow ratio and backwashing cycle on treatment efficiencies were investigated. The wastewater was treated by the BAF process under optimal conditions: the HRT of 1.0 h, the air/water volume flow ratio of about 5 : 1 and the backwashing cycle of every 4-7 days. The results showed that the average removal efficiency of COD, oil pollutants and SS was 84.5%, 94.0% and 83.4%, respectively. And the average effluent concentration of COD, oil pollutants and SS was 12.5, 0.27, 14.5 mg·L^-1, respectively. The experimental results demonstrated that the BAF process is a suitable and highly efficient method to treat the wastewater.展开更多
Biological aerated filters have many advantages such as small volume and high treatment efficiency. This research focused on sewage treatment performance of integrated biological aerated filter (IBAF) under different ...Biological aerated filters have many advantages such as small volume and high treatment efficiency. This research focused on sewage treatment performance of integrated biological aerated filter (IBAF) under different conditions such as aeration, hydraulic retention time and the height of fillers layer, to identify the turn of marked affecting factor of removal performance through orthogonal experiments, optimize the function parameter of IBAF, reveal the regularity of sewage treatment of IBAF under different conditions, and adopt suitable measures to guarantee excess water quality of IBAF.展开更多
The optimum media height of carbon oxidation and nitrification in a down-flow biological aerated filter was determined, and the distribution of the heterotrophic and nitrifying populations through studying the changes...The optimum media height of carbon oxidation and nitrification in a down-flow biological aerated filter was determined, and the distribution of the heterotrophic and nitrifying populations through studying the changes of organic carbon contents and ammonia concentration at different media height was got. The results showed that as a down flow BAF with granular media, the active layer of nitrifiers was deeper than heterotrophs in BAF. And the optimum media height for the removal of SS, COD Cr and NH + 4-N was 40 cm,60 cm and 80 cm respectively. The removal efficiency of SS, COD Cr and NH + 4-N was 79.1%, 63.9% and 96.4% respectively under the influent COD Cr and NH + 4-N of 122.1 mgCOD Cr /L and 14.84 mgNH + 4-N/L, the influent flux of 15.8 L/h, air to liquid ratio of 3∶1.展开更多
The aim of this work was the determination of the optimal aerations, and more specifically the corresponding optimal air velocities uopt, at which the largest COD removals were achieved in treatment of industrial wast...The aim of this work was the determination of the optimal aerations, and more specifically the corresponding optimal air velocities uopt, at which the largest COD removals were achieved in treatment of industrial wastewaters of various strength conducted in the inverse fluidized bed biofilm reactor. The largest COD removals were achieved at the following air velocities uopt and retention times ts, and (Vb/VR) = 0.55: i) for CODo = 72,780 mg/l at uopt = 0.052 m/s and ts = 80 h;ii) for CODo = 62,070 mg/l at uopt = 0.042 m/s and ts = 65 h;iii) for CODo = 49,130 mg/l at uopt = 0.033 m/s and ts= 55 h;iv) for CODo = 41,170 mg/l at uopt = 0.028 m/s and ts = 45 h;v) for CODo = 35,460 mg/l at uopt = 0.025 m/s and ts = 27.5 h;and vi) for CODo = 26,470 mg/l at uopt= 0.014 m/s and ts = 22.5 h. In the treatment operation conducted in a reactor optimally controlled at the above values of uopt, ts and (Vb/VR), the following decreases in COD were obtained: i) from 72,780 to 5410 mg/l;ii) from 62,070 to 3730 mg/l;iii) from 49,130 to 2820 mg/l;iv) from 41,170 to 1820 mg/l;v) from 35,460 to 1600 mg/l;and vi) from 26,470 to 1180 mg/l, that is, approximately a 93%, 94%, 95%, 96%, 95% and 96% COD reduction was attained, respectively.展开更多
基金Supported by the National Natural Science Foundation of China (No.59978020).
文摘The biological aerated filter (BAF) was used to treat the oil-field produced water. The removal efficiency for oil, COD, BOD and suspended solids (SS) was 76.3%-80.3%, 31.6%-57.9%, 8.6.3%-96.3% and76.4%--82.7%, respectively when the hydraulic loading rates varied from 016m·h^-1 to 1.4m·h^-1. The greatest partof removal, for example more than 80% of COD removal, occurred on the top 100cm of the media in BAF. The kinetic .performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loadingrates, in biological aerated filters could be described by c1/c1=l-exp(-2.44/L^0.59). This equation could be used topredict the B OD.removal efficiency at different hydraulic loading rates.
基金Supported by the Foundation of Science and Technology Project of Guangdong Province (2004B33301001)
文摘The slightly polluted wastewater from oil refinery contains some COD, oil pollutants and suspended solids (SS). A small-scale fixed film biological aerated filter (BAF) process was used to treat the wastewater. The influences of hydraulic retention time (HRT), air/water volume flow ratio and backwashing cycle on treatment efficiencies were investigated. The wastewater was treated by the BAF process under optimal conditions: the HRT of 1.0 h, the air/water volume flow ratio of about 5 : 1 and the backwashing cycle of every 4-7 days. The results showed that the average removal efficiency of COD, oil pollutants and SS was 84.5%, 94.0% and 83.4%, respectively. And the average effluent concentration of COD, oil pollutants and SS was 12.5, 0.27, 14.5 mg·L^-1, respectively. The experimental results demonstrated that the BAF process is a suitable and highly efficient method to treat the wastewater.
文摘Biological aerated filters have many advantages such as small volume and high treatment efficiency. This research focused on sewage treatment performance of integrated biological aerated filter (IBAF) under different conditions such as aeration, hydraulic retention time and the height of fillers layer, to identify the turn of marked affecting factor of removal performance through orthogonal experiments, optimize the function parameter of IBAF, reveal the regularity of sewage treatment of IBAF under different conditions, and adopt suitable measures to guarantee excess water quality of IBAF.
文摘The optimum media height of carbon oxidation and nitrification in a down-flow biological aerated filter was determined, and the distribution of the heterotrophic and nitrifying populations through studying the changes of organic carbon contents and ammonia concentration at different media height was got. The results showed that as a down flow BAF with granular media, the active layer of nitrifiers was deeper than heterotrophs in BAF. And the optimum media height for the removal of SS, COD Cr and NH + 4-N was 40 cm,60 cm and 80 cm respectively. The removal efficiency of SS, COD Cr and NH + 4-N was 79.1%, 63.9% and 96.4% respectively under the influent COD Cr and NH + 4-N of 122.1 mgCOD Cr /L and 14.84 mgNH + 4-N/L, the influent flux of 15.8 L/h, air to liquid ratio of 3∶1.
文摘The aim of this work was the determination of the optimal aerations, and more specifically the corresponding optimal air velocities uopt, at which the largest COD removals were achieved in treatment of industrial wastewaters of various strength conducted in the inverse fluidized bed biofilm reactor. The largest COD removals were achieved at the following air velocities uopt and retention times ts, and (Vb/VR) = 0.55: i) for CODo = 72,780 mg/l at uopt = 0.052 m/s and ts = 80 h;ii) for CODo = 62,070 mg/l at uopt = 0.042 m/s and ts = 65 h;iii) for CODo = 49,130 mg/l at uopt = 0.033 m/s and ts= 55 h;iv) for CODo = 41,170 mg/l at uopt = 0.028 m/s and ts = 45 h;v) for CODo = 35,460 mg/l at uopt = 0.025 m/s and ts = 27.5 h;and vi) for CODo = 26,470 mg/l at uopt= 0.014 m/s and ts = 22.5 h. In the treatment operation conducted in a reactor optimally controlled at the above values of uopt, ts and (Vb/VR), the following decreases in COD were obtained: i) from 72,780 to 5410 mg/l;ii) from 62,070 to 3730 mg/l;iii) from 49,130 to 2820 mg/l;iv) from 41,170 to 1820 mg/l;v) from 35,460 to 1600 mg/l;and vi) from 26,470 to 1180 mg/l, that is, approximately a 93%, 94%, 95%, 96%, 95% and 96% COD reduction was attained, respectively.