期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
On the optimisation of age of the air in the breathing zone of floor heating systems:The role of ventilation design
1
作者 Aminhossein Jahanbin Giovanni Semprini 《Energy and Built Environment》 2024年第1期130-142,共13页
For a mechanically ventilated space,the nominal age of the air can be obtained by the reciprocal of the air change rate.However,values of the local mean age of the air in practice may differ to some extent from the no... For a mechanically ventilated space,the nominal age of the air can be obtained by the reciprocal of the air change rate.However,values of the local mean age of the air in practice may differ to some extent from the nominal one since the nominal time constant employs as reference the theoretical optimum model.This discrepancy could become more prominent in spaces conditioning with both ventilation and heating system where the indoor air pattern is affected by turbulent mixed convection flow.Given importance of knowledge on the distribution of age of the air in these spaces,the present study provides insights on how ventilation design in floor heating systems can optimise the delivery of fresh air into the breathing zone.In this context,by establishing a computational fluid dynamic(CFD)model validated against experimental data,the local mean age of the air as well as the indoor air quality(IAQ)indices in the breathing zone of the floor heating system are examined under different ventilation modes.Six different ventilation scenarios are regarded in order to find the optimal ventilation design in terms of the delivery of the fresh air and ventilation effectiveness in occupied space.Furthermore,the integrated effects of the floor temperature and inlet supply temperature along with the ventilation design on the distribution of local age of the air are addressed.The obtained results indicate that the up-supply ventilation strategy is more efficient than down-supply one in the ventilation effectiveness and delivery of fresh air into the breathing zone.Moreover,it is shown that the mean age of the air in the breathing zone of the up-supply ventilation increases with increment of the Ri(Richardson number),whereas an increase in Ri improves the delivery of fresh air in down-supply mode.For a given floor temperature,the similar trend is also observed in the variation of age of the air with the characteristic temperature of supply inlet,namely the temperature difference between inlet supply and surrounding walls. 展开更多
关键词 age of the air Indoor air quality Ventilation Floor heating CFD
原文传递
Numerical investigation on effects of side curtain opening behavior on indoor climate of naturally ventilated dairy buildings 被引量:2
2
作者 Qifeng Li Chuanxia Yao +4 位作者 Luyu Ding Ligen Yu Weihong Ma Ronghua Gao Wengang Zheng 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2020年第5期63-72,共10页
The side-curtain is popular in cattle buildings to regulate indoor climates and ventilation rates by adjusting the opening ratio.It normally had three different adjusting strategies relate to the position of rollers,i... The side-curtain is popular in cattle buildings to regulate indoor climates and ventilation rates by adjusting the opening ratio.It normally had three different adjusting strategies relate to the position of rollers,i.e.central roller(S1),top roller(S2)and bottom roller(S3),which result in different opening behaviors to generate the same opening ratio but different opening positions in the side wall for a full-curtain house.Numerical simulations were conducted using computational fluid dynamics(CFD)to investigate the effects of the eight potential opening behaviors of side curtains on the indoor climates and airflow rates in winter for a typical naturally ventilated dairy house in China when the opening ratio were 8.5%and 17%.Airflow patterns,wind chilled temperature(WCT)and age of air were analyzed in the animal occupied zone(AOZ)by taking reference planes.Openings at the very bottom of side walls had more efficient ventilation due to the younger air age,more effective air disturbing,more uniformly distributed indicators in AOZ.However,it will result in a lower WCT in AOZ although a lower ventilation rate was observed in this case.Openings on the very top of side wall would generate a better thermal comfort in AOZ but with very poor air quality and nonuniformly distributed airflows in the dairy house.S1 was not recommended to the practical application due to the poor indoor climate and the higher cost of the mechanical structure.Based on the comprehensive evaluations of the analytic hierarchy process,the most satisfaction opening positions were at the bottom of the side curtains and the optimized adjusting strategy is S2. 展开更多
关键词 thermal comfort age of air ventilation rate computational fluid dynamics analytic hierarchy process
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部