The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol partic...The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol particles. The study focused on how commercial instruments perform during routine measurements respect to OPC scientific understanding, because it is important for users of such instruments to be aware of their limitations. Measurements were performed using aerosol generated by a Monodisperse Aerosol Generator (MAGE), which produced carnauba wax particles of diameter (1.00 ± 0.08) μm and (1.40 ± 0.15) μm, and monodisperse Polystyrene Latex (PSL) aerosol with nominal diameter of 1.0mm. The results show comparable total particle number concentrations for all the counters, when the count of the first size channel (0.3 - 0.4 μm) for the 1.108 Grimm counter was left out. In the said channel the Grimm counter 1.108 always showed much higher particle counts than those inferred from the tested aerosols. The overcount was proved by the fact that the aerosol sampled in each test on a Nuclepore filter showed no particles in the 0.3 - 0.4 μm range when examined under Scanning Electronic Microscope (SEM). The presence of an artefact produced by the counter was assumed as a likely explanation. For all the counters, the Count Median Diameters (CMDs) of aerosol size distributions, were far below the expected value for the aerosol used. The nearest CMD values to the expected ones were shown by the Grimm 1.107 counter.展开更多
The mass concentration and size distribution of aerosols in Tokaimura were investigated using a high-volume and a low-volume Andersen sampler. A difference was found using the two samplers: the concentration of total...The mass concentration and size distribution of aerosols in Tokaimura were investigated using a high-volume and a low-volume Andersen sampler. A difference was found using the two samplers: the concentration of total aerosols determined with the high-volume sampler is smaller than that of the low-volume sampler by 70-90% throughout the year. Compared to the high-volume sampler, low-volume sampler gave lower concentration for aerosols 〉7 μm, higher concentration for aerosols of 3.3-7.0 μm and 〈 1.1 μm, though similar results for aerosols of 1.1-3.3 μm. The low-volume sampler was found to have better separation efficiency and higher accuracy.展开更多
文摘The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol particles. The study focused on how commercial instruments perform during routine measurements respect to OPC scientific understanding, because it is important for users of such instruments to be aware of their limitations. Measurements were performed using aerosol generated by a Monodisperse Aerosol Generator (MAGE), which produced carnauba wax particles of diameter (1.00 ± 0.08) μm and (1.40 ± 0.15) μm, and monodisperse Polystyrene Latex (PSL) aerosol with nominal diameter of 1.0mm. The results show comparable total particle number concentrations for all the counters, when the count of the first size channel (0.3 - 0.4 μm) for the 1.108 Grimm counter was left out. In the said channel the Grimm counter 1.108 always showed much higher particle counts than those inferred from the tested aerosols. The overcount was proved by the fact that the aerosol sampled in each test on a Nuclepore filter showed no particles in the 0.3 - 0.4 μm range when examined under Scanning Electronic Microscope (SEM). The presence of an artefact produced by the counter was assumed as a likely explanation. For all the counters, the Count Median Diameters (CMDs) of aerosol size distributions, were far below the expected value for the aerosol used. The nearest CMD values to the expected ones were shown by the Grimm 1.107 counter.
基金partly supported by National Natural Science Foundation of China(NSFC,40575066)Japan Society for the Promotion of Science(JSPS).
文摘The mass concentration and size distribution of aerosols in Tokaimura were investigated using a high-volume and a low-volume Andersen sampler. A difference was found using the two samplers: the concentration of total aerosols determined with the high-volume sampler is smaller than that of the low-volume sampler by 70-90% throughout the year. Compared to the high-volume sampler, low-volume sampler gave lower concentration for aerosols 〉7 μm, higher concentration for aerosols of 3.3-7.0 μm and 〈 1.1 μm, though similar results for aerosols of 1.1-3.3 μm. The low-volume sampler was found to have better separation efficiency and higher accuracy.