Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categor...Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.展开更多
It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, t...It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger.展开更多
With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the ...With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.展开更多
High temperature heat hazard at mineral mine becomes more and more serious as the increase of mining depth.Heat sources at working faces of mineral mines are complex and are of different characteristics,presenting new...High temperature heat hazard at mineral mine becomes more and more serious as the increase of mining depth.Heat sources at working faces of mineral mines are complex and are of different characteristics,presenting new challenges for air conditioning systems.In this paper,heat sources at four types of working faces are summarized and their characteristics are investigated.Based on this,simplified equations,which are linear with length of working faces,are proposed to calculate heat dissipation rates.So that the main heat sources of different working faces can be found,and cooling load of air conditioning systems can be calculated.Then,considering main heat sources of coal mines,a typical working face is designed to investigate performances of different ventilation systems and air conditioning systems.Simulation results show that segmented ventilation systems(SC)and heat shield assisted centralized ventilation systems(CCHS)can realize much better temperature distributions at working faces.However,cooling load can be greatly reduced for CCHS,when untreated air is supplied to the coal seam side.Based on this,free cooling assisted air conditioning systems are designed,and annual average energy efficiency ratio(EERann)of the systems are investigated and compared between direct evaporate cooling and indirect evaporate cooling(IEC).For SC,as compared with scenarios without free-cooling,IEC can increase EERann by 15%-23%and 22%-32%under Benxi and Datong ambient conditions,respectively.Besides,to ensure high EERann,CCHS is preferred and it is essential to increase thermal insulation of air ducts.展开更多
On the bads of theory and experiment, this paper studies and analyses the factors such as water - air ratio, air velocity, spraying water pressure and initial water temperature, which affect the heat and mass transfer...On the bads of theory and experiment, this paper studies and analyses the factors such as water - air ratio, air velocity, spraying water pressure and initial water temperature, which affect the heat and mass transfer in air washer , thus can help us to reduce the power consumption and Improve the efficiency of heat and mass transfer.展开更多
The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of re...The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of refrigerant charge amount should be investigated during the design phase. In this study, experimental method was employed to investigate the influence of the refrigerant charge amount on the performance of the ACHP system. The results showed that the refrigerant charge amount had different influence on the refrigerant properties at various locations within the system. The coefficient of performance and pressure-enthalpy diagram were calculated, and showed a close relationship with refrigerant charge amount under different compressor speeds. The degree of subcooling and the degree of superheating were recorded and the critical charge amount was determined by a typical practical test method. In addition, the critical refrigerant charge amount determined by the experimental method was also compared with two typical void fraction correlation models, and the model with consideration of two phase stream reaction of the refrigerant showed a good estimation accuracy on the critical charge amount.展开更多
When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insu...When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed).展开更多
This study developed an appropriate ground cooling system that can be used for indoor cooling during summers in rural houses in northeastern China.To apply this system,a traditional rural house was selected and a heat...This study developed an appropriate ground cooling system that can be used for indoor cooling during summers in rural houses in northeastern China.To apply this system,a traditional rural house was selected and a heat exchanger was designed(PE pipe,32 m in length),manufactured,and installed according to the cooling load(2206 kJ/h)of one room of the experimental house.According to the experiment,the temperature of Room 1 equipped with the cooling system was 3℃ lower than that of Room 2 without the ground cooling system during the same time period.The temperature reduction effect of this system was confirmed through this study.When the ground cooling system was used in rural houses in Northeast China,it was found that a burial depth of 1.5-2.0 m for the ground heat exchanger is appropriate for considering workability and frost line.The use of the ground cooling system for indoor cooling during summers for rural houses in the northeastern region of China would reduce not only environmental pollution and the use of fossil fuels but also ease farmers off a certain amount of financial burden.展开更多
文摘Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.
文摘It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger.
基金Financial supports for this project, provided by the key program supported by the National Natural Science Foundation of China(No. 51134005)the Doctoral Scientific Fund Project of the Ministry of Education of China (No. 20120023120004), are gratefully acknowledged
文摘With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.
基金The authors appreciate the support from the National Natural Science Foundation of China(No.51706015)from the Fundamental Research Funds for the Central Universities(FRF-IDRY-19-01).
文摘High temperature heat hazard at mineral mine becomes more and more serious as the increase of mining depth.Heat sources at working faces of mineral mines are complex and are of different characteristics,presenting new challenges for air conditioning systems.In this paper,heat sources at four types of working faces are summarized and their characteristics are investigated.Based on this,simplified equations,which are linear with length of working faces,are proposed to calculate heat dissipation rates.So that the main heat sources of different working faces can be found,and cooling load of air conditioning systems can be calculated.Then,considering main heat sources of coal mines,a typical working face is designed to investigate performances of different ventilation systems and air conditioning systems.Simulation results show that segmented ventilation systems(SC)and heat shield assisted centralized ventilation systems(CCHS)can realize much better temperature distributions at working faces.However,cooling load can be greatly reduced for CCHS,when untreated air is supplied to the coal seam side.Based on this,free cooling assisted air conditioning systems are designed,and annual average energy efficiency ratio(EERann)of the systems are investigated and compared between direct evaporate cooling and indirect evaporate cooling(IEC).For SC,as compared with scenarios without free-cooling,IEC can increase EERann by 15%-23%and 22%-32%under Benxi and Datong ambient conditions,respectively.Besides,to ensure high EERann,CCHS is preferred and it is essential to increase thermal insulation of air ducts.
文摘On the bads of theory and experiment, this paper studies and analyses the factors such as water - air ratio, air velocity, spraying water pressure and initial water temperature, which affect the heat and mass transfer in air washer , thus can help us to reduce the power consumption and Improve the efficiency of heat and mass transfer.
基金supported by The Open Project Program of State Key Laboratory of Fire Science (No. HZ2018-KF03)Shanghai Sailing Program (No. 18YF1417900)Huaqiao University Scientific Research Foundation (No. 16BS801)
文摘The application of air conditioning heat pump(ACHP) in electric vehicles could lead to significant electrical power saving effect. As for an air conditioning heat pump system for electric vehicles, the influence of refrigerant charge amount should be investigated during the design phase. In this study, experimental method was employed to investigate the influence of the refrigerant charge amount on the performance of the ACHP system. The results showed that the refrigerant charge amount had different influence on the refrigerant properties at various locations within the system. The coefficient of performance and pressure-enthalpy diagram were calculated, and showed a close relationship with refrigerant charge amount under different compressor speeds. The degree of subcooling and the degree of superheating were recorded and the critical charge amount was determined by a typical practical test method. In addition, the critical refrigerant charge amount determined by the experimental method was also compared with two typical void fraction correlation models, and the model with consideration of two phase stream reaction of the refrigerant showed a good estimation accuracy on the critical charge amount.
文摘When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed).
基金This work was supported by National Science and technology support program of the Ministry of science and technology of China(2012BAJ26B00).
文摘This study developed an appropriate ground cooling system that can be used for indoor cooling during summers in rural houses in northeastern China.To apply this system,a traditional rural house was selected and a heat exchanger was designed(PE pipe,32 m in length),manufactured,and installed according to the cooling load(2206 kJ/h)of one room of the experimental house.According to the experiment,the temperature of Room 1 equipped with the cooling system was 3℃ lower than that of Room 2 without the ground cooling system during the same time period.The temperature reduction effect of this system was confirmed through this study.When the ground cooling system was used in rural houses in Northeast China,it was found that a burial depth of 1.5-2.0 m for the ground heat exchanger is appropriate for considering workability and frost line.The use of the ground cooling system for indoor cooling during summers for rural houses in the northeastern region of China would reduce not only environmental pollution and the use of fossil fuels but also ease farmers off a certain amount of financial burden.