A Rogowski coil was designed to measure partial discharge (PD) signal with low currents and high frequency. The possibilities of obtaining better measurements of PDs were explored by changing the inductance, mutual ...A Rogowski coil was designed to measure partial discharge (PD) signal with low currents and high frequency. The possibilities of obtaining better measurements of PDs were explored by changing the inductance, mutual inductance, resistance, and capacitance of the coil. The designed Rogowski coil was calibrated under square wave voltage and arbitrary sine wave voltage. Then, according to the parameters of the Rogowski coil, the effect of changing some of these variables was simulated using a bode plot. Comparison shows that the simulation results were consistent with the experimental ones. A needle-plate in air gap model was set up and its PD under impulse voltage was measured. The results demonstrate that the Rogowski coil is adapted to measurement of PDs.展开更多
An ideal current distribution in the air core transformer coils is obtained using variation principle.Climbing mountain method is utilized for optimizing the dimension and position of the real coils.Not only can the r...An ideal current distribution in the air core transformer coils is obtained using variation principle.Climbing mountain method is utilized for optimizing the dimension and position of the real coils.Not only can the requirement of minimizing the stray field in the plasma region be guaranteed,but also integer turns for the coil can be realized.The latter brings a significant convenience to engineering.展开更多
基金The National Natural Science Foundation of China (No.50977075)
文摘A Rogowski coil was designed to measure partial discharge (PD) signal with low currents and high frequency. The possibilities of obtaining better measurements of PDs were explored by changing the inductance, mutual inductance, resistance, and capacitance of the coil. The designed Rogowski coil was calibrated under square wave voltage and arbitrary sine wave voltage. Then, according to the parameters of the Rogowski coil, the effect of changing some of these variables was simulated using a bode plot. Comparison shows that the simulation results were consistent with the experimental ones. A needle-plate in air gap model was set up and its PD under impulse voltage was measured. The results demonstrate that the Rogowski coil is adapted to measurement of PDs.
文摘An ideal current distribution in the air core transformer coils is obtained using variation principle.Climbing mountain method is utilized for optimizing the dimension and position of the real coils.Not only can the requirement of minimizing the stray field in the plasma region be guaranteed,but also integer turns for the coil can be realized.The latter brings a significant convenience to engineering.