Death toll by smoke in fire is estimated at 70% which emphasizes the importance of smoke control system to deal with the fire smoke. In advanced countries, the studies on method to prevent smoke spread by forming the ...Death toll by smoke in fire is estimated at 70% which emphasizes the importance of smoke control system to deal with the fire smoke. In advanced countries, the studies on method to prevent smoke spread by forming the air curtain using high velocity jet flow are underway now. In this study, a linear-jet type air curtain system is proposed to prevent the smoke spread and analysis of flow characteristics of pressure chamber, which is the core component, is conducted through numerical analysis and experimental approach. Consequently, the pressure was increased in 2D functional way to input air flowrate and about 595 Pa pressure was formed at pressure chamber inlet in response to 30 m/s nozzle jet velocity.展开更多
Control of dust in underground coal mines is critical for mitigating both safety and health hazards.For decades,the National Institute of Occupational Safety and Health(NIOSH)has led research to evaluate the effective...Control of dust in underground coal mines is critical for mitigating both safety and health hazards.For decades,the National Institute of Occupational Safety and Health(NIOSH)has led research to evaluate the effectiveness of various dust control technologies in coal mines.Recent studies have included the evaluation of auxiliary scrubbers to reduce respirable dust downstream of active mining and the use of canopy air curtains(CACs)to reduce respirable dust in key operator positions.While detailed dust characterization was not a focus of such studies,this is a growing area of interest.Using preserved filter samples from three previous NIOSH studies,the current work aims to explore the effect of two different scrubbers(one wet and one dry)and a roof bolter CAC on respirable dust composition and particle size distribution.For this,the preserved filter samples were analyzed by thermogravimetric analysis and/or scanning electron microscopy with energy dispersive X-ray.Results indicate that dust composition was not appreciably affected by either scrubber or the CAC.However,the wet scrubber and CAC appeared to decrease the overall particle size distribution.Such an effect of the dry scrubber was not consistently observed,but this is probably related to the particular sampling location downstream of the scrubber which allowed for significant mixing of the scrubber exhaust and other return air.Aside from the insights gained with respect to the three specific dust control case studies revisited here,this work demonstrates the value of preserved dust samples for follow-up investigation more broadly.展开更多
In high-rise building fires, the most immediate threat to passenger life and safety evacuation is the smoke inhalation. Some traditional models for smoke prevention and exhaust are analyzed and compared with the smoke...In high-rise building fires, the most immediate threat to passenger life and safety evacuation is the smoke inhalation. Some traditional models for smoke prevention and exhaust are analyzed and compared with the smoke-preventing air curtain. The rationality and the feasibility of the air curtain are theoretically expounded. The air volume, tuyere width and jet velocity in the air curtain experiment are designed according to the theoreti- cal calculation model. Experimental results indicate that the effect of air curtain to prevent smoke diffusion is re- markable as the volume ratio of air-smoke is about 0. 6, the jet angle is between 25^o and 35^o, and the jet thickness is between 25 mm and 45 mm. The efficiency of air curtain can reach 98% on the entraining effect. Meanwhile, experiments verify the theorectical calculation.展开更多
A new air distribution pattern,air curtain jet ventilation was presented.The ventilation or airflow patterns and the air velocity produced by air curtain jet were investigated in detail.To identify the airflow charact...A new air distribution pattern,air curtain jet ventilation was presented.The ventilation or airflow patterns and the air velocity produced by air curtain jet were investigated in detail.To identify the airflow characteristics of this novel air curtain jet ventilation system,a full-scale room was used to measure the jet velocity with a slot-ventilated supply device,with regards to the airflow fields along the vertical wall as well as on the horizontal floor zones.The airflow fields under three supply air velocities,1.0,1.5 and 2.0 m/s,were carried out in the full-scale room.The experimental results show the velocity profiles of air distribution,the airflow fields along the attached vertical wall and the air lake zones on the floor,respectively.The current experimental research is helpful for heating,ventilation and air conditioning(HVAC) engineers to design better air distribution in rooms.展开更多
Canopy air curtain (CAC) technology has been developed by the National Institute for Occupational Safety and Health (NIOSH) for use on continuous miners and subsequently roof bolting machines in underground coal m...Canopy air curtain (CAC) technology has been developed by the National Institute for Occupational Safety and Health (NIOSH) for use on continuous miners and subsequently roof bolting machines in underground coal mines to protect operators of these machines from overexposure to respirable coal mine dust. The next logical progression is to develop a CAC for shuttle cars to protect operators from the same overexposures. NIOSH awarded a contract to Marshall University and J.H. Fletcher to develop the shuttle car CAC. NIOSH conducted laboratory testing to determine the dust control efficiency of the shuttle car CAC. Testing was conducted on two different cab configurations: a center drive similar to that on a Joy 10SC32AA cab model and an end drive similar to that on a Joy 10SC32AB cab model. Three different ventilation velocities were tested-0.61, 2.0, 4.3 rrds (120, 400, and 850 fpm). The lowest, 0.61 m/s (120 fpm), represented the ventilation velocity encountered during loading by the continuous miner, while the 4.3 m/s (850 fpm) velocity represented ventilation velocity airflow over the shuttle car while tramming against ventilation airflow. Test results showed an average of the dust control efficiencies ranging from 74 to 83% for 0.61 m/s (120 fpm), 39%-43% for 2.0 m/s (400 fpm), and 6%-16% for 4.3 m/s (850 fpm). Incorporating an airflow spoiler to the shuttle car CAC design and placing the CAC so that it is located 22.86 cm (9 in.) forward of the operator improved the dust control efficiency to 51%-55% for 4.3 m/s (850 fpm) with minimal impact on dust control efficiencies for lower ventilation velocities. These laboratory tests demonstrate that the newly developed shuttle car CAC has the potential to successfully protect shuttle car operators from coal mine respirable dust overexposures.展开更多
A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow...A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow across the canopy area as recommended by the National Institute for Occupational Safety and Health.The new modifications include a plenum that is constructed of a single flat aluminum plate,smaller-diameter airflow openings,and a single row of perimeter nozzles designed to prevent mine air contaminated by respirable dust from entering the CAC protection zone.Field testing was conducted on this new 3rd generation design showing reductions in coal mine respirable dust exposure for roof bolter operators.Dust control efficiencies for the CAC for the left bolter operator(intake side)ranged from approximately 26%–60%,while the efficiencies for the CAC for the right bolter operator(return side)ranged from 3%to 47%.展开更多
At a fully mechanized working face of a coal mine as prototype,we investigated,by simulation,the flow field and dust distribution during the process of its isolation by a curtain of air,using the CFD software, Fluent....At a fully mechanized working face of a coal mine as prototype,we investigated,by simulation,the flow field and dust distribution during the process of its isolation by a curtain of air,using the CFD software, Fluent.The results show that the air curtain installed on the shearer can effectively prevent the dust (especially the respirable dust)from diffusing into the work area of the operator,reducing the dust concentration on the side of the operator and greatly improving his working environment.The field application of the air curtain shows that the dust-isolation effect of an air curtain is quite noticeable.The isolation efficiency for respiratory dust is over 70%and,as well,it has good dust-isolation effect for nonrespiratory dust.The air curtain is a useful way to resolve the problem of dust-isolation at a fully mechanized working face.It has a practical background elsewhere with more extensive applications.展开更多
A combined method of numerical simulation and field testing was adopted in this study in the interest of solving the problem of hard to control high concentrate dusts on a fully mechanized mining face. In addi- tion, ...A combined method of numerical simulation and field testing was adopted in this study in the interest of solving the problem of hard to control high concentrate dusts on a fully mechanized mining face. In addi- tion, the dust suppression effect of a multi-direction whirling air curtain was studied in this paper. Under the influence of the wall attachment effect, the compressed air which blows out from the two-phase or three-phase radial outlets on the generator of the air curtain can form a multi-direction whirling air curtain, which can cover the whole roadway section of a fully mechanized mining face. The traditional method of controlling dust is a forcing system with exhaust overlap which has the major disadvantage of lacking a jet effect and consequently results in poor dust control. It is difficult to form the air flow field within the range of Lp ≤ 5√S. However, due to the effect of this novel system, the radial airflow can be turned into axial airflow allowing fresh air to flow through the length of the heading. The air flow field which is good at controlling dust diffusion can be formed 12.8 m from the heading face. Furthermore, the field measurement results show that before the application of a multi-direction whirling air curtain, the dust concentration is 348.6 mg/m^3 and 271.4 mg/m^3 respectively at the roadway cross-section measurement points which are 5 m and 10 m from the heading face. However, after the application of the multi-direction whirling air curtain, the dust concentration is only 61.2 mg/m3 and 14.8 mg/m^3, respectively. Therefore, the dust control effect of a multi-direction whirling air curtain is obvious.展开更多
Indoor environment separated with down-feed air curtain was numerically simulated and experimen-tally researched. Indoor airflow and temperature fields separated with air curtain were numerically simulated. Re-sults s...Indoor environment separated with down-feed air curtain was numerically simulated and experimen-tally researched. Indoor airflow and temperature fields separated with air curtain were numerically simulated. Re-sults show that both polluted airflow and thermal air current can be separated with a down-feed air curtain to pre-vent contaminants from spreading in the room space. In a test chamber, the smoke of burning Tibetan incense served as the source of contaminants, and the probe test shows that 1.0 μm is the prevailing diameter of the smoke particles. During the release of the smoke, the particle concentration of the indoor air was tested with a laser particle counter at the points of three different heights from the floor when the air curtain was running or not. Experimental results show that the higher the test point is located, the lower the particle concentration is, implying that the sepa-rating or isolating effect decreases as the air velocity of the curtain reduces along with the height descends. Accord-ing to both simulation and experimental results, down-feed air curtain can separate indoor environment effectively when the supply air velocity of air curtain is not less than 3 m/s. In order to strengthen separation effect, it is sug-gested that the supply air velocity be speeded up to 5 m/s.展开更多
The low-oxygen environment restricts the exploitation of mineral resources on plateaus and affects miner’s safety.This paper proposes an oxygen-enrichment method using an annular air curtain.Through numerical simulat...The low-oxygen environment restricts the exploitation of mineral resources on plateaus and affects miner’s safety.This paper proposes an oxygen-enrichment method using an annular air curtain.Through numerical simulation and experiments,it was confirmed that the proposed method improves the breathing environment in the single-head roadway of a plateau mine.Computational fluid dynamics(CFD)was used to investigate the oxygen-enriching effect and oxygen spatial distribution regularities after using the proposed oxygen-enrichment method in the single-head roadway of a plateau mine.The reliability of the CFD model was confirmed by experiment.Orthogonal testing was conducted to investigate the influence degree and optimal level combination of factors influencing oxygen enrichment.The results demonstrate that the annular air curtain effectively prevented oxygen loss,thus forming a local oxygen-rich space and improving the effective utilization rate of oxygen.Oxygen supply concentration and velocity are positively correlated with the oronasal oxygen mass fraction through a linear function,while the air curtain outlet wind velocity is negatively correlated with the oronasal oxygen mass fraction through a linear function.The annular air curtain diameter and oronasal oxygen mass fraction do not have an obvious functional relationship.When the annular air curtain diameter was greater than 0.9 m,the oronasal oxygen mass fraction was stable at approximately 25.30%.The influencing factors of the novel oxygen-enrichment method are,in descending order,as follows:oxygen supply concentration,annular air curtain diameter,air curtain outlet wind velocity,and oxygen supply velocity.The optimal level combination is oxygen supply concentration of 100%,oxygen supply velocity of 11 m/s,air curtain outlet wind velocity of 1.5 m/s,and annular air curtain diameter of 0.9 m.展开更多
文摘Death toll by smoke in fire is estimated at 70% which emphasizes the importance of smoke control system to deal with the fire smoke. In advanced countries, the studies on method to prevent smoke spread by forming the air curtain using high velocity jet flow are underway now. In this study, a linear-jet type air curtain system is proposed to prevent the smoke spread and analysis of flow characteristics of pressure chamber, which is the core component, is conducted through numerical analysis and experimental approach. Consequently, the pressure was increased in 2D functional way to input air flowrate and about 595 Pa pressure was formed at pressure chamber inlet in response to 30 m/s nozzle jet velocity.
基金CDC/NIOSH for funding this research(75D30119C05529)。
文摘Control of dust in underground coal mines is critical for mitigating both safety and health hazards.For decades,the National Institute of Occupational Safety and Health(NIOSH)has led research to evaluate the effectiveness of various dust control technologies in coal mines.Recent studies have included the evaluation of auxiliary scrubbers to reduce respirable dust downstream of active mining and the use of canopy air curtains(CACs)to reduce respirable dust in key operator positions.While detailed dust characterization was not a focus of such studies,this is a growing area of interest.Using preserved filter samples from three previous NIOSH studies,the current work aims to explore the effect of two different scrubbers(one wet and one dry)and a roof bolter CAC on respirable dust composition and particle size distribution.For this,the preserved filter samples were analyzed by thermogravimetric analysis and/or scanning electron microscopy with energy dispersive X-ray.Results indicate that dust composition was not appreciably affected by either scrubber or the CAC.However,the wet scrubber and CAC appeared to decrease the overall particle size distribution.Such an effect of the dry scrubber was not consistently observed,but this is probably related to the particular sampling location downstream of the scrubber which allowed for significant mixing of the scrubber exhaust and other return air.Aside from the insights gained with respect to the three specific dust control case studies revisited here,this work demonstrates the value of preserved dust samples for follow-up investigation more broadly.
文摘In high-rise building fires, the most immediate threat to passenger life and safety evacuation is the smoke inhalation. Some traditional models for smoke prevention and exhaust are analyzed and compared with the smoke-preventing air curtain. The rationality and the feasibility of the air curtain are theoretically expounded. The air volume, tuyere width and jet velocity in the air curtain experiment are designed according to the theoreti- cal calculation model. Experimental results indicate that the effect of air curtain to prevent smoke diffusion is re- markable as the volume ratio of air-smoke is about 0. 6, the jet angle is between 25^o and 35^o, and the jet thickness is between 25 mm and 45 mm. The efficiency of air curtain can reach 98% on the entraining effect. Meanwhile, experiments verify the theorectical calculation.
基金Projects(50778145, 50278025) supported by the National Natural Science Foundation of ChinaProject(2009ZDKG-47) supported by "13115" Science and Technology Innovation Program of Shaanxi Province, China
文摘A new air distribution pattern,air curtain jet ventilation was presented.The ventilation or airflow patterns and the air velocity produced by air curtain jet were investigated in detail.To identify the airflow characteristics of this novel air curtain jet ventilation system,a full-scale room was used to measure the jet velocity with a slot-ventilated supply device,with regards to the airflow fields along the vertical wall as well as on the horizontal floor zones.The airflow fields under three supply air velocities,1.0,1.5 and 2.0 m/s,were carried out in the full-scale room.The experimental results show the velocity profiles of air distribution,the airflow fields along the attached vertical wall and the air lake zones on the floor,respectively.The current experimental research is helpful for heating,ventilation and air conditioning(HVAC) engineers to design better air distribution in rooms.
文摘Canopy air curtain (CAC) technology has been developed by the National Institute for Occupational Safety and Health (NIOSH) for use on continuous miners and subsequently roof bolting machines in underground coal mines to protect operators of these machines from overexposure to respirable coal mine dust. The next logical progression is to develop a CAC for shuttle cars to protect operators from the same overexposures. NIOSH awarded a contract to Marshall University and J.H. Fletcher to develop the shuttle car CAC. NIOSH conducted laboratory testing to determine the dust control efficiency of the shuttle car CAC. Testing was conducted on two different cab configurations: a center drive similar to that on a Joy 10SC32AA cab model and an end drive similar to that on a Joy 10SC32AB cab model. Three different ventilation velocities were tested-0.61, 2.0, 4.3 rrds (120, 400, and 850 fpm). The lowest, 0.61 m/s (120 fpm), represented the ventilation velocity encountered during loading by the continuous miner, while the 4.3 m/s (850 fpm) velocity represented ventilation velocity airflow over the shuttle car while tramming against ventilation airflow. Test results showed an average of the dust control efficiencies ranging from 74 to 83% for 0.61 m/s (120 fpm), 39%-43% for 2.0 m/s (400 fpm), and 6%-16% for 4.3 m/s (850 fpm). Incorporating an airflow spoiler to the shuttle car CAC design and placing the CAC so that it is located 22.86 cm (9 in.) forward of the operator improved the dust control efficiency to 51%-55% for 4.3 m/s (850 fpm) with minimal impact on dust control efficiencies for lower ventilation velocities. These laboratory tests demonstrate that the newly developed shuttle car CAC has the potential to successfully protect shuttle car operators from coal mine respirable dust overexposures.
文摘A 3rd generation roof bolter canopy air curtain(CAC)has been developed and constructed by J.H.Fletcher&Co.,Inc.As with the previous generation of the CAC,this design uses the principle of providing uniform airflow across the canopy area as recommended by the National Institute for Occupational Safety and Health.The new modifications include a plenum that is constructed of a single flat aluminum plate,smaller-diameter airflow openings,and a single row of perimeter nozzles designed to prevent mine air contaminated by respirable dust from entering the CAC protection zone.Field testing was conducted on this new 3rd generation design showing reductions in coal mine respirable dust exposure for roof bolter operators.Dust control efficiencies for the CAC for the left bolter operator(intake side)ranged from approximately 26%–60%,while the efficiencies for the CAC for the right bolter operator(return side)ranged from 3%to 47%.
基金Financial support for this work,provided by the National Natural Science Foundation of China(No.50974060)the State Safety Production Science and Technology Development Plan (No.06-396)
文摘At a fully mechanized working face of a coal mine as prototype,we investigated,by simulation,the flow field and dust distribution during the process of its isolation by a curtain of air,using the CFD software, Fluent.The results show that the air curtain installed on the shearer can effectively prevent the dust (especially the respirable dust)from diffusing into the work area of the operator,reducing the dust concentration on the side of the operator and greatly improving his working environment.The field application of the air curtain shows that the dust-isolation effect of an air curtain is quite noticeable.The isolation efficiency for respiratory dust is over 70%and,as well,it has good dust-isolation effect for nonrespiratory dust.The air curtain is a useful way to resolve the problem of dust-isolation at a fully mechanized working face.It has a practical background elsewhere with more extensive applications.
基金supported by the Key Program of the Coal Joint Funds of the National Natural Science Foundation of China (No.U1261205)the Youth Program of National Natural Science Foundation of China (No.51404147)+2 种基金the Class General Financial Grant from the China Postdoctoral Science Foundation (No.2015M570601)the Scientific Research Foundation of Shandong University of Science and Technology for Recruited Talents (No.2014RCJJ029)the State Key Laboratory of Mining Disaster Prevention and Control Co-founded by Shandong Province and the Ministry of Science and Technology,Shandong University of Science and Technology (No.MDPC2013ZR02)
文摘A combined method of numerical simulation and field testing was adopted in this study in the interest of solving the problem of hard to control high concentrate dusts on a fully mechanized mining face. In addi- tion, the dust suppression effect of a multi-direction whirling air curtain was studied in this paper. Under the influence of the wall attachment effect, the compressed air which blows out from the two-phase or three-phase radial outlets on the generator of the air curtain can form a multi-direction whirling air curtain, which can cover the whole roadway section of a fully mechanized mining face. The traditional method of controlling dust is a forcing system with exhaust overlap which has the major disadvantage of lacking a jet effect and consequently results in poor dust control. It is difficult to form the air flow field within the range of Lp ≤ 5√S. However, due to the effect of this novel system, the radial airflow can be turned into axial airflow allowing fresh air to flow through the length of the heading. The air flow field which is good at controlling dust diffusion can be formed 12.8 m from the heading face. Furthermore, the field measurement results show that before the application of a multi-direction whirling air curtain, the dust concentration is 348.6 mg/m^3 and 271.4 mg/m^3 respectively at the roadway cross-section measurement points which are 5 m and 10 m from the heading face. However, after the application of the multi-direction whirling air curtain, the dust concentration is only 61.2 mg/m3 and 14.8 mg/m^3, respectively. Therefore, the dust control effect of a multi-direction whirling air curtain is obvious.
基金Supported by Science Foundation of Tianjin Higher Educational Committee (No. 20031109).
文摘Indoor environment separated with down-feed air curtain was numerically simulated and experimen-tally researched. Indoor airflow and temperature fields separated with air curtain were numerically simulated. Re-sults show that both polluted airflow and thermal air current can be separated with a down-feed air curtain to pre-vent contaminants from spreading in the room space. In a test chamber, the smoke of burning Tibetan incense served as the source of contaminants, and the probe test shows that 1.0 μm is the prevailing diameter of the smoke particles. During the release of the smoke, the particle concentration of the indoor air was tested with a laser particle counter at the points of three different heights from the floor when the air curtain was running or not. Experimental results show that the higher the test point is located, the lower the particle concentration is, implying that the sepa-rating or isolating effect decreases as the air velocity of the curtain reduces along with the height descends. Accord-ing to both simulation and experimental results, down-feed air curtain can separate indoor environment effectively when the supply air velocity of air curtain is not less than 3 m/s. In order to strengthen separation effect, it is sug-gested that the supply air velocity be speeded up to 5 m/s.
基金supports of the National Natural Science Foundation of China(No.52274247)the Postgraduate Scientific Research Innovation Project of Hunan Province(No.CX20220196).
文摘The low-oxygen environment restricts the exploitation of mineral resources on plateaus and affects miner’s safety.This paper proposes an oxygen-enrichment method using an annular air curtain.Through numerical simulation and experiments,it was confirmed that the proposed method improves the breathing environment in the single-head roadway of a plateau mine.Computational fluid dynamics(CFD)was used to investigate the oxygen-enriching effect and oxygen spatial distribution regularities after using the proposed oxygen-enrichment method in the single-head roadway of a plateau mine.The reliability of the CFD model was confirmed by experiment.Orthogonal testing was conducted to investigate the influence degree and optimal level combination of factors influencing oxygen enrichment.The results demonstrate that the annular air curtain effectively prevented oxygen loss,thus forming a local oxygen-rich space and improving the effective utilization rate of oxygen.Oxygen supply concentration and velocity are positively correlated with the oronasal oxygen mass fraction through a linear function,while the air curtain outlet wind velocity is negatively correlated with the oronasal oxygen mass fraction through a linear function.The annular air curtain diameter and oronasal oxygen mass fraction do not have an obvious functional relationship.When the annular air curtain diameter was greater than 0.9 m,the oronasal oxygen mass fraction was stable at approximately 25.30%.The influencing factors of the novel oxygen-enrichment method are,in descending order,as follows:oxygen supply concentration,annular air curtain diameter,air curtain outlet wind velocity,and oxygen supply velocity.The optimal level combination is oxygen supply concentration of 100%,oxygen supply velocity of 11 m/s,air curtain outlet wind velocity of 1.5 m/s,and annular air curtain diameter of 0.9 m.