In this work,based on the role of pre-ionization of the non-uniform electric field and its effect of reducing the collisional ionization coefficient,a diffuse dielectric barrier discharge plasma is formed in the open ...In this work,based on the role of pre-ionization of the non-uniform electric field and its effect of reducing the collisional ionization coefficient,a diffuse dielectric barrier discharge plasma is formed in the open space outside the electrode structure at a lower voltage by constructing a three-dimensional non-uniform spatial electric field using a contact electrode structure.The air purification study is also carried out.Firstly,a contact electrode structure is constructed using a three-dimensional wire electrode.The distribution characteristics of the spatial electric field formed by this electrode structure are analyzed,and the effects of the non-uniform electric field and the different angles of the vertical wire on the generation of three-dimensional spatial diffuse discharge are investigated.Secondly,the copper foam contact electrode structure is constructed using copper foam material,and the effects of different mesh sizes on the electric field distribution are analyzed.The results show that as the mesh size of the copper foam becomes larger,a strong electric field region exists not only on the surface of the insulating layer,but also on the surface of the vertical wires inside the copper foam,i.e.,the strong electric field region shows a three-dimensional distribution.Besides,as the mesh size increases,the area of the vertical strong electric field also increases.However,the electric field strength on the surface of the insulating layer gradually decreases.Therefore,the appropriate mesh size can effectively increase the discharge area,which is conducive to improving the air purification efficiency.Finally,a highly permeable stacked electrode structure of multilayer wire-copper foam is designed.In combination with an ozone treatment catalyst,an air purification device is fabricated,and the air purification experiment is carried out.展开更多
In the context of a sudden contraction plug conduit,the near-wall area experiences a significant shearing effect of water flow,however,the extent to which this shearing effect occurs in bubble-water flow and the relat...In the context of a sudden contraction plug conduit,the near-wall area experiences a significant shearing effect of water flow,however,the extent to which this shearing effect occurs in bubble-water flow and the related variation mechanisms of air bubble size and number remain unclear.This study employs a model test method to investigate the diffusion process of bubble-water flow in a sudden contraction plug conduit.The size and number of bubbles,as well as their distribution along the shearing section under varying initial air volume conditions,are studied in detail using a high-speed image acquisition system.The experimental findings reveal a self-similar relationship between the number and size of bubbles and their cross-sectional distribution over time.The bubble number and size vary in three stages,i.e.,quasi-suspension,shearing,and shearing completion stages.The direction perpendicular to the conduit exhibits peak values in bubble number distribution over the three stages,with peak value location varying with the near-wall area.As time progresses,the peak value increases,and a larger initial air volume corresponds to a smaller distance of the peak value location from the wall.The size of air bubbles near the wall is consistent with the minimum diameter of air bubbles in shear flow and is hardly affected by the initial air volume.These results aid in comprehending the change law of two-phase water and air flow under a strong shearing effect in the plug conduit,and provide useful insights for hydraulic design in fluid engineering.展开更多
Rapid increase of urban underground constructions has a great consideration of underground environment safety and how to expel toxic gasses out of tunnels effectively.The utility tunnel is a typical urban tunnel const...Rapid increase of urban underground constructions has a great consideration of underground environment safety and how to expel toxic gasses out of tunnels effectively.The utility tunnel is a typical urban tunnel construction with multiple underground pipelines including gas pipelines,and it is necessary to investigate characteristic of gas diffusion and monitor gas leakage to ensure tunnel safety.In this study,the experimental measurements of airflow and gas distributions were conducted in a 10 m full-scaled utility tunnel mockup,and gas diffusion characteristic was also investigated.Numerical simulation of utility tunnel leakage was also conducted by computational fluid dynamics(CFD).Different turbulence models and different air supply diffuser models were compared via the experimental results based on visualization and the relative root-mean-square error(RRMSE)index,which quan-titated the difference between the numerical and experimental results.The results showed that the standard k−εturbulence model and random air opening model could provide better results than other models.According to the experimental data analysis,it was necessary to consider the optimization of monitoring detector arrangements in actual utility tunnels.This study provided basic experimental data and the validated numerical model for the leakage source identification and underground tunnels simulation research.展开更多
基金supported by the Fundamental Research Funds for the Central Universities(No.2022YJS094)。
文摘In this work,based on the role of pre-ionization of the non-uniform electric field and its effect of reducing the collisional ionization coefficient,a diffuse dielectric barrier discharge plasma is formed in the open space outside the electrode structure at a lower voltage by constructing a three-dimensional non-uniform spatial electric field using a contact electrode structure.The air purification study is also carried out.Firstly,a contact electrode structure is constructed using a three-dimensional wire electrode.The distribution characteristics of the spatial electric field formed by this electrode structure are analyzed,and the effects of the non-uniform electric field and the different angles of the vertical wire on the generation of three-dimensional spatial diffuse discharge are investigated.Secondly,the copper foam contact electrode structure is constructed using copper foam material,and the effects of different mesh sizes on the electric field distribution are analyzed.The results show that as the mesh size of the copper foam becomes larger,a strong electric field region exists not only on the surface of the insulating layer,but also on the surface of the vertical wires inside the copper foam,i.e.,the strong electric field region shows a three-dimensional distribution.Besides,as the mesh size increases,the area of the vertical strong electric field also increases.However,the electric field strength on the surface of the insulating layer gradually decreases.Therefore,the appropriate mesh size can effectively increase the discharge area,which is conducive to improving the air purification efficiency.Finally,a highly permeable stacked electrode structure of multilayer wire-copper foam is designed.In combination with an ozone treatment catalyst,an air purification device is fabricated,and the air purification experiment is carried out.
基金supported by the National Natural Science Foundation of China(Grant Nos.52192673,51979182).
文摘In the context of a sudden contraction plug conduit,the near-wall area experiences a significant shearing effect of water flow,however,the extent to which this shearing effect occurs in bubble-water flow and the related variation mechanisms of air bubble size and number remain unclear.This study employs a model test method to investigate the diffusion process of bubble-water flow in a sudden contraction plug conduit.The size and number of bubbles,as well as their distribution along the shearing section under varying initial air volume conditions,are studied in detail using a high-speed image acquisition system.The experimental findings reveal a self-similar relationship between the number and size of bubbles and their cross-sectional distribution over time.The bubble number and size vary in three stages,i.e.,quasi-suspension,shearing,and shearing completion stages.The direction perpendicular to the conduit exhibits peak values in bubble number distribution over the three stages,with peak value location varying with the near-wall area.As time progresses,the peak value increases,and a larger initial air volume corresponds to a smaller distance of the peak value location from the wall.The size of air bubbles near the wall is consistent with the minimum diameter of air bubbles in shear flow and is hardly affected by the initial air volume.These results aid in comprehending the change law of two-phase water and air flow under a strong shearing effect in the plug conduit,and provide useful insights for hydraulic design in fluid engineering.
基金This study supported by the National Natural Science Foundation of China(Grant No.51708286)the Natural Science Foundation of Jiangsu Province(No.BK20171015)+1 种基金The study was also supported by the National Natural Science Foundation of China(Grant No.51478468)the National Natural Science Foundation of China)No.51978166.
文摘Rapid increase of urban underground constructions has a great consideration of underground environment safety and how to expel toxic gasses out of tunnels effectively.The utility tunnel is a typical urban tunnel construction with multiple underground pipelines including gas pipelines,and it is necessary to investigate characteristic of gas diffusion and monitor gas leakage to ensure tunnel safety.In this study,the experimental measurements of airflow and gas distributions were conducted in a 10 m full-scaled utility tunnel mockup,and gas diffusion characteristic was also investigated.Numerical simulation of utility tunnel leakage was also conducted by computational fluid dynamics(CFD).Different turbulence models and different air supply diffuser models were compared via the experimental results based on visualization and the relative root-mean-square error(RRMSE)index,which quan-titated the difference between the numerical and experimental results.The results showed that the standard k−εturbulence model and random air opening model could provide better results than other models.According to the experimental data analysis,it was necessary to consider the optimization of monitoring detector arrangements in actual utility tunnels.This study provided basic experimental data and the validated numerical model for the leakage source identification and underground tunnels simulation research.