Heating-only fan coil(HFC)is one of the suited end users,which is not only compact but also highly efficient.And the major factors affecting the heat dissipation performance of HFC include leakage through coil bypass,...Heating-only fan coil(HFC)is one of the suited end users,which is not only compact but also highly efficient.And the major factors affecting the heat dissipation performance of HFC include leakage through coil bypass,distance between fan and coil,fan structure and air inlet type.Under natural air convection or forced,experimental studies were made on the effects of these factors upon the heat dissipation performance of HFC.The results show that:1)After reducing the leakage through coil bypass,the heat dissipation of HFC increases 16.9% under natural convection,and increases 8.3% under forced convection.2)After the distance between fan and coil be raised from 23.2cm to 41.7cm,the heat dissipation of HFC decreases 21.3% under natural convection,but increases12.8% under forced convection.3)After changing the fan structure,the heat dissipation of HFC increases 41.8% under natural convection,and the heat dissipation per motor power increases 96.1% under forced convection.4)The heat dissipations of HFC with round pass,slit and strip type of air inlet are different,whose proportion is about 100%,110%,136% under natural convection,and 100%,105%,116% under forced convection.展开更多
Based on the corresponding theories of engineering thermodynamics and hydro-dynamics, a careful study is made of the characteristics of air flow in different duct-embedded ways. According to critical Reynolds number, ...Based on the corresponding theories of engineering thermodynamics and hydro-dynamics, a careful study is made of the characteristics of air flow in different duct-embedded ways. According to critical Reynolds number, the atmospheric critical velocity of the duct with different diameters, which makes laminar flow different from turbulent flow, is calculated. Given the condition in which a forced flow occurs and the wind strength is larger than the atmospheric pressure gradient along the air-duct, a rational ratio of the length to the diameter is presented. Based on the above theory and field test data on soil temperature and embankment settlement, the advantages and disadvantages are discussed in details of all duct-embedded ways that might affect the stability of embankment.展开更多
An unsteady three-dimensional analysis of the ventilation performance is carried out for different ventilation strategies to find out a ventilation method with a high performance in a subway tunnel.The natural ventila...An unsteady three-dimensional analysis of the ventilation performance is carried out for different ventilation strategies to find out a ventilation method with a high performance in a subway tunnel.The natural ventilation performance associated with a train-induced air flow in a subway tunnel is examined.The dynamic layering method is used to consider the moving boundary of a train in the current CFD method.The geometries of the modeled tunnel and the subway train are partially based on those of the Seoul subway.The effects of the structure of the ventilation duct and the geometry of the partitions on the ventilation performance are evaluated.The results show that the combined ventilation ducts (to be designed),and the partitioning blocks installed along the middle of tunnel (already in existences) are helpful for air exchange.This study can provide some guidance for the design of ventilation ducts in a subway system.展开更多
基金Supported by National11th Five-Year Plan Major Scientific and Technological Issues of China(2006BAJ01A04)
文摘Heating-only fan coil(HFC)is one of the suited end users,which is not only compact but also highly efficient.And the major factors affecting the heat dissipation performance of HFC include leakage through coil bypass,distance between fan and coil,fan structure and air inlet type.Under natural air convection or forced,experimental studies were made on the effects of these factors upon the heat dissipation performance of HFC.The results show that:1)After reducing the leakage through coil bypass,the heat dissipation of HFC increases 16.9% under natural convection,and increases 8.3% under forced convection.2)After the distance between fan and coil be raised from 23.2cm to 41.7cm,the heat dissipation of HFC decreases 21.3% under natural convection,but increases12.8% under forced convection.3)After changing the fan structure,the heat dissipation of HFC increases 41.8% under natural convection,and the heat dissipation per motor power increases 96.1% under forced convection.4)The heat dissipations of HFC with round pass,slit and strip type of air inlet are different,whose proportion is about 100%,110%,136% under natural convection,and 100%,105%,116% under forced convection.
文摘Based on the corresponding theories of engineering thermodynamics and hydro-dynamics, a careful study is made of the characteristics of air flow in different duct-embedded ways. According to critical Reynolds number, the atmospheric critical velocity of the duct with different diameters, which makes laminar flow different from turbulent flow, is calculated. Given the condition in which a forced flow occurs and the wind strength is larger than the atmospheric pressure gradient along the air-duct, a rational ratio of the length to the diameter is presented. Based on the above theory and field test data on soil temperature and embankment settlement, the advantages and disadvantages are discussed in details of all duct-embedded ways that might affect the stability of embankment.
文摘An unsteady three-dimensional analysis of the ventilation performance is carried out for different ventilation strategies to find out a ventilation method with a high performance in a subway tunnel.The natural ventilation performance associated with a train-induced air flow in a subway tunnel is examined.The dynamic layering method is used to consider the moving boundary of a train in the current CFD method.The geometries of the modeled tunnel and the subway train are partially based on those of the Seoul subway.The effects of the structure of the ventilation duct and the geometry of the partitions on the ventilation performance are evaluated.The results show that the combined ventilation ducts (to be designed),and the partitioning blocks installed along the middle of tunnel (already in existences) are helpful for air exchange.This study can provide some guidance for the design of ventilation ducts in a subway system.