This study aims to optimize the influence of the inlet inclination angle on the Indoor Air Quality(IAQ),heat,and temperature distribution in mixed convection within a two-dimensional square cavityfilled with an air-CO_(...This study aims to optimize the influence of the inlet inclination angle on the Indoor Air Quality(IAQ),heat,and temperature distribution in mixed convection within a two-dimensional square cavityfilled with an air-CO_(2)mixture.The air-CO_(2)mixture enters the cavity through two inlet openings positioned at the top wall,which is set at the ambient temperature(TC).Three values of the Reynolds numbers,ranging from 1000 to 2000,are considered,while the Prandtl number is kept constant(Pr=0.71).The temperature distribution and streamlines are shown for Rayleigh number(Ra)equal to 104,three inlet inclination anglesϕ(0,π/6 andπ/4)and three CO_(2)concentrations values(1500,2500,3500 ppm)applied at both hot vertical walls(maintained at a constant temperature TH).Afinite volume method is used under the assumption of two-dimensional laminarflow to solve the NavierStokes and energy equations.The results indicate that inlet inclination angle has an impact on the indoor air quality(IAQ),which,in turn,affects the heat transfer distribution and thermal comfort within the cavity.展开更多
The amount of moisture in the air is represented by relative humidity(RH);an ideal level of humidity in the interior environment is between 40%and 60%at temperatures between 18°and 20°Celsius.When the RH fal...The amount of moisture in the air is represented by relative humidity(RH);an ideal level of humidity in the interior environment is between 40%and 60%at temperatures between 18°and 20°Celsius.When the RH falls below this level,the environment becomes dry,which can cause skin dryness,irritation,and discomfort at low temperatures.When the humidity level rises above 60%,a wet atmosphere develops,which encourages the growth of mold and mites.Asthma and allergy symptoms may occur as a result.Human health is harmed by excessive humidity or a lack thereof.Dehumidifiers can be used to provide an optimal level of humidity and a stable and pleasant atmosphere;certain models disinfect and purify the water,reducing the spread of bacteria.The design and implementation of a client-server indoor and outdoor air quality monitoring application are presented in this paper.The Netatmo station was used to acquire the data needed in the application.The client is an Android application that allows the user to monitor air quality over a period of their choosing.For a good monitoring process,the Netatmo modules were used to collect data from both environments(indoor:temperature(T),RH,carbon dioxide(CO_(2)),atmospheric pressure(Pa),noise and outdoor:T and RH).The data is stored in a database,using MySQL.The Android application allows the user to view the evolution of the measured parameters in the form of graphs.Also,the paper presents a prediction model of RH using Azure Machine Learning Studio(Azure ML Studio).The model is evaluated using metrics:Mean Absolute Error(MAE),Root Mean Squared Error(RMSE),Relative Absolute Error(RAE),Relative Squared Error(RSE)and Coefficient of Determination(CoD).展开更多
Individuals spend 90% of their time indoors, primarily at home or at work. Indoor environmental factors have a significant impact on human well-being. It was a longitudinal study that assessed the major factors that r...Individuals spend 90% of their time indoors, primarily at home or at work. Indoor environmental factors have a significant impact on human well-being. It was a longitudinal study that assessed the major factors that reduce indoor air quality, namely particulate matter, and bio-aerosols, using low-cost sensors and the settle plate method, respectively also to determine the effect of atmospheric parameters and land use patterns in households of commercial, industrial, residential, slum, and rural areas of the city. PM2.5 concentration levels were similar in most parts of the day across all sites. PM10.0 concentration levels increased indoors in a commercial area. PM2.5 concentration showed a negative correlation with temperature and a positive correlation with relative humidity in some areas. Very high values of PM2.5 concentration and PM10.0 concentration have been observed in this study, inside households of selected rural and urban areas. Pathogenic gram-positive cocci, gram-positive rods, Aspergillus, and Mucor species were the most common bacterial and fungal species respectively found inside households. This study examined particulate matter concentration along with bio-aerosols, as very less studies have been conducted in Jaipur the capital of Rajasthan, a state in the western part of India which assessed both of these factors together to determine the indoor air quality. Rural households surrounding the periphery of the city were found to have similar pollution levels as urban households. So, this study may form the basis for reducing pollution inside households and also for taking suitable measures for the reduction of pollution in the indoor environment.展开更多
Background,aim,and scope Owing to the rapid development of modernisation and urbanisation,living standards have gradually improved.However,the widespread use of high-energy-consuming indoor appliances and furniture ha...Background,aim,and scope Owing to the rapid development of modernisation and urbanisation,living standards have gradually improved.However,the widespread use of high-energy-consuming indoor appliances and furniture has made indoor environments a primary environmental problem affecting human health.Sick building syndrome(SBS)and building-related illness(BRI)have occurred,and indoor air conditions have been extensively studied.Common indoor pollutants include CO,CO_(2),volatile organic compounds(VOCs)(such as the formaldehyde and benzene series),NOx(NO and NO_(2)),and polycyclic aromatic hydrocarbons(PAHs).VOCs have replaced SO_(2)as the“The Fourteenth Five-Year Plan”urban air quality assessment new indicators.Indoor VOCs can cause diseases such as cataract,asthma,and lung cancer.To protect human health,researchers have proposed several indoor air purification technologies,including adsorption,filtration,electrostatic dust removal,ozonation,and plant purification.However,each technology has drawbacks,such as high operating costs,high energy consumption,and the generation of secondary waste or toxic substances.Plant degradation of VOCs as a bioremediation technology has the characteristics of low cost,high efficiency,and sustainability,thereby becoming a potential green solution for improving indoor air quality.This study introduces the research status and mechanism of plant removal of indoor VOCs and provides an experimental basis and scientific guidance for analysing the mechanism of plant degradation of pollutants.Materials and methods This study reviews studies on the harm caused by indoor pollutants to human health and related sources,mainly investigating the degradation of indoor formaldehyde,BTEX(benzene,toluene,ethylbenzene,and xylene)plant mechanisms,and research results.Results Plants can remove VOCs via stomatal and non-stomatal adsorption,interfoliar microbial,rhizosphere microbial,and growth media.Benzene,toluene,and xylene(BTX)are adsorbed by pores,hydroxylated into fumaric acid,and then removed into CO_(2) and H_(2)O by TCA.Formaldehyde enters plant leaves through the stomata and epidermal waxy substances and is adsorbed.After the two steps of enzymatic oxidation,formic acid and CO_(2) are generated.Finally,it enters the Calvin cycle and removes glucose and other nontoxic compounds.Discussion The non-stomatal degradation of VOCs can be divided into adsorption by cuticular wax and active adsorption by plant surface microorganisms.The leaf epidermal waxy matter content and the lipid composition of the epidermal membrane covering the plant surface play important roles in the non-stomatal adsorption of indoor air pollutants.The leaf margin of a plant is an ecological environment containing various microbial communities.The endophytic and inoculated microbiota in plant buds and leaves can remove VOCs(formaldehyde and BTEX).Formaldehyde can be directly absorbed by plant leaves and converted into organic acids,sugars,CO_(2) and H_(2)O by microbes.Bioremediation of indoor VOCs is usually inefficient,leading to plant toxicity or residual chemical substance volatilisation through leaves,followed by secondary pollution.Therefore,plants must be inoculated with microorganisms to improve the efficiency of plant degradation of VOCs.However,the effectiveness of interfoliar microbial removal remains largely unknown and several microorganisms are not culturable.Therefore,methods for collecting,identifying,and culturing microorganisms must be developed.As the leaf space is a relatively unstable environment,the degradation of VOCs by rhizosphere microorganisms is equally important,and formaldehyde is absorbed more by rhizosphere microorganisms at night.The inoculation of bacteria into the rhizosphere improves the efficiency of plants in degrading VOCs.However,most of these studies were conducted in simulation chambers.To ensure the authenticity of these conclusions,the ability of plants to remove indoor air pollutants must be further verified in real situations.Conclusions Plant purification is an economical,environment-friendly,and sustainable remediation technology.This review summarises the mechanisms of VOC plant degradation and presents its limitations.Simultaneously,it briefly puts forward a plant selection scheme according to different temperatures,light,and specific VOCs that can be absorbed to choose the appropriate plant species.However,some studies have denied the purification effect of plants and proposed that numerous plants are required to achieve indoor ventilation effects.Therefore,determining the ability of plants to remove indoor VOCs requires a combination of realistic and simulated scenarios.Recommendations and perspectives Plants and related microorganisms play an important role in improving indoor air quality,therefore,the effect of plants and the related microorganisms on improving indoor air quality must be studied further and the effect of plants on indoor VOCs will be the focus of future research.展开更多
Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using ...Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using an MQ2 gas detector,and microcontroller/Arduino-Uno.The design steps included bonding and connecting readymade sensors,coding,and finally testing the device.Testing has been conducted in Environment and Pollution Engineering Department laboratories,at the Technical Engineering College of Kirkuk.This study proposed the use of an MQ2 sensor for multi-gas rate detection which can exist indoors.The system uses also a DHT22 sensor for measuring environment temperature and humidity.The sensors are connected to Arduino and LCD to present data on LCD by powering the system with external power.Overall,the testing was conducted,and the device served as a measuring tool for indoor air as an accurate multi-gas rate detector.展开更多
Environmental monitoring of airborne formaldehyde (FA) using sensitive methodologies is fundamental to prevent health risks. The objective of this study was to compare three different FA monitoring methods during the ...Environmental monitoring of airborne formaldehyde (FA) using sensitive methodologies is fundamental to prevent health risks. The objective of this study was to compare three different FA monitoring methods during the daily activities of an anatomic pathology laboratory. Daily eight-hour measurements deriving from Radiello® passive diffusive samplers (PDS), NEMo XT continuous optical sensor (COS), and multi-gas 1512 photoacoustic monitor (MPM) were simultaneously compared over a period of 14 working days. Given the different daily distributions of the measurements performed by the three devices, all measurements were time-aligned for comparison purposes. The 95% limit of agreement (LOA) method was applied to estimate the degree of concordance of each device with respect to the others. Formaldehyde arithmetic mean measured using PDS was 32.6 ± 10.4 ppb (range: 19.8 - 62.7). The simultaneous measures performed by COS and MPM were respectively 42.4 ± 44.8 ppb (range: 7.0 - 175.0) and 189.0 ± 163.7 ppb (range: 40.0 - 2895.4). The MPM geometric mean (171.3 ppb) was approximately five times higher than those derived from COS (32.3 ppb) and PDS (31.4 ppb). The results of the LOA method applied to log-transformed FA data showed the same systematic discrepancies between MPM and the other two devices. A good agreement between PDS and COS could lead to a tailored approach according to the individual specificity of these techniques. This tool may be useful for accurately assessing the risk of FA exposure among healthcare workers. However, the limited specificity of the MPM does not support its use as a monitoring method for FA in the workplace.展开更多
Study Objective: The purpose of the study is to present independent laboratory testing for a novel technology in air and on surfaces. Since 2020, public health goals have focused on improving indoor air quality. This ...Study Objective: The purpose of the study is to present independent laboratory testing for a novel technology in air and on surfaces. Since 2020, public health goals have focused on improving indoor air quality. This includes protection from airborne pathogens, such as tuberculosis, RSV, SARS-CoV-2, common cold or influenza viruses, measles, and others. Engineering controls are highly effective at reducing hazardous pathogens found in indoor air and from recontamination of surfaces. This occurs from a continuous cycle of settling of small, sustained airborne pathogens, which may become dehumidified, becoming airborne again, carried by room air currents around indoor spaces, then repeating the cycle. Methods: The novel technology utilizes a catalytic process to produce safe levels of hydrogen peroxide gas that are effective in reducing pathogens in the air and on surfaces. Air testing was performed with the MS2 bacteriophage, the test organism for ASHRAE standard 241, and methicillin-Resistant Staphylococcus aureus (MRSA). Surface testing was performed with SARS-COV-2 (Coronavirus COVID-19) and H1N1 (Influenza). Typical ventilation and filtration does not effectively remove disbursed pathogens from the entire facility, due to inconsistent air circulation and surface deposits of pathogens. Results: MS2 was reduced by 99.9%;MRSA was reduced by 99.9%;SARS-CoV-2 was reduced by 99.9%;H1N1 was reduced by 99.9%. Conclusion: This novel catalytic converter reduces a variety of pathogens in the air (99%) and on surfaces (99%), by actively disinfecting with the introduction of gaseous hydrogen peroxide. This active disinfection provides a strong solution for protecting the entire facility and its occupants.展开更多
This research focuses on the evaluation of diverse approaches for removing formaldehyde from indoor environments,which is a significant concern for indoor air quality.The study systematically examines physical,chemica...This research focuses on the evaluation of diverse approaches for removing formaldehyde from indoor environments,which is a significant concern for indoor air quality.The study systematically examines physical,chemical,and biological methods to ascertain their effectiveness in formaldehyde mitigation.Physical methods,including air circulation and adsorption,particularly with activated carbon and molecular sieves,are assessed for their efficiency in various concentration scenarios.Chemical methods,such as photocatalytic oxidation using titanium dioxide and plasma technology,are analyzed for their ability to decompose formaldehyde into non-toxic substances.Additionally,biological methods involving plant purification and microbial transformation are explored for their eco-friendly and sustainable removal capabilities.The paper concludes that while each method has its merits,a combined approach may offer the most effective solution for reducing indoor formaldehyde levels.The study underscores the need for further research to integrate these methods in a practical,cost-effective,and environmentally sustainable manner,highlighting their potential to improve indoor air quality significantly.展开更多
To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,...To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,is investigated.A questionnaire survey and field tests are used to collect data.According to the data of twelve rooms in this building,objective evaluation and the subjective evaluation of the IAQ are obtained.Almost all of the environmental parameters in these rooms basically meet the standards of the objective evaluation.But the average concentration of carbon dioxide in most rooms cannot reach the value of the cleanliness standards,1 255 mg/m^3.The average acceptability of the IAQ in these rooms is 71%,which is lower than the value of the ASHRAE 55—1992 standards,80%.The proper increase in the wind speed and the indoor fresh air supply can greatly improve the objective evaluation and the subjective evaluation of the IAQ.展开更多
A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive o...A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 ±1.53 mg/m^3) compared to outdoor air (0.71± 0.46 mg/m^3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building.展开更多
The environmental air quality is one of the important problems of people′s concern. The study on human exposure to air pollutants provides an important basis for the nuprorement of human health effects. The question...The environmental air quality is one of the important problems of people′s concern. The study on human exposure to air pollutants provides an important basis for the nuprorement of human health effects. The questionnaire about time activity patterns includes questions about time spent in the houses, personal activities, indoor combustion sources, information about hobbies, (e.g. smoking), home repairing and decorating materials, and personal product use and so on. The questionnaire was conducted with 662 respondents over 16 years of age in Tianjin, China from fall 1995 to summer 1996. The results of the investigation show that 84% of people′s activities happen indoors, and 58% in family. The field researches of air pollutants monitoring of the most important air pollutants either indoors or outdoors, including carbon monoxide (CO), formaldehyde (HCHO), inhaled particulate (IR), and Benzpyrene(Bap), were carried out in winter and summer from 1995 to 1996. The results of the study on human exposure to four selected air pollutants show that indoor sources and their air pollution cause relatively high exposure in the total air pollution exposures. For example, only the exposure indoors at home is 71.0%,60.3%, 69.4% and 74.0% respectively for CO, HCHO, IR and Bap in the total air pollution exposure.展开更多
This is the first detailed characterization of the airborne bacterial profiles in indoor environments. Two restaurants were selected for this study. Fifteen genera of bacteria were isolated from each restaurant and id...This is the first detailed characterization of the airborne bacterial profiles in indoor environments. Two restaurants were selected for this study. Fifteen genera of bacteria were isolated from each restaurant and identified by three different bacterial identification systems including MIDI, Biolog and Riboprinter. The dominant bacteria of both restaurants were Gram-positive bacteria in which Micrococcus and Bacillus species were the most abundant. Most bacteria identified were representative species of skin and respiratory tract of human, and soil. Although the bacterial levels in these two restaurants were below the limit of the Hong Kong Indoor Air Quality Objective (HKIAQO) Level 1 standard (i.e., 〈 500 cfu/m^3), the majority of these bacteria were opportunistic pathogens. These results suggested that the identity of airborne bacteria should also be included in the IAQ to ensure there is a safety guideline for the public.展开更多
Objective The changes in serum adipokines and cytokines related to oxidative stress were examined during 3 months ‘Off to On’ and ‘On to Off’ periods using negatively charged particle-dominant indoor air condition...Objective The changes in serum adipokines and cytokines related to oxidative stress were examined during 3 months ‘Off to On’ and ‘On to Off’ periods using negatively charged particle-dominant indoor air conditions(NCPDIAC).Methods Seven volunteers participated in the study,which included ‘OFF to 3 months ON’ periods(ON trials) for a total of 16 times,and ‘ON to 3 months OFF’(OFF trials) periods for a total of 13 times.Results With the exception of one case,serum amyloid A(SAA) levels decreased significantly during the ON trials.Conclusion Considering that SAA is an acute phase reactive protein such as C reactive protein(CRP),this observed decrease might indicate the prevention of cardiovascular and atherosclerotic changes,since an increase in high-sensitive CRP is associated with the subsequent detection of these events.展开更多
With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that ther...With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that there is a significant sensitivity differen ce in indoor environment between southerners and northerners in China. People fr om different regions have different demands for their working and living environ ment. Therefore, as a good design of air conditioning system, it is strongly rec ommended that the different demands of people from different regions should be t aken into consideration.展开更多
Experiments on the behavior of airborne microparticle sediments and their adhesion on glass slides were conducted in a laboratory located on the first floor of a teaching building. Clean tiles and glass slides were pl...Experiments on the behavior of airborne microparticle sediments and their adhesion on glass slides were conducted in a laboratory located on the first floor of a teaching building. Clean tiles and glass slides were placed at different angles (0°, 45° and 90°) with respect to the horizontal plane in the laboratory. The sedimentation of microparticles was investigated at certain time intervals (1 d, 3 d, l0 d and 30 d). The results of testing, at day 30, show that the diameters of particles on the horizontal tiles varied from 20 to 80 μm; few particles with diameter less than 0.5 μm or greater than 100 μm were found. The amount of particle sediment on all the slides increased along over time, while the average diameter of particles was not correlated with time, nor with the angle of placement. The maximum particle size, the total particle surface area, the total perimeter of all particles and the cover ratio of light (the proportion of total area of particles to the observed area of the slides surfaces) did not change significantly within the first 10 days. Inspection of all the samples for the last 20 days, however, showed that these variables increased substantially with the passage of time and were in reverse proportion to the placement angles, which indicates a concentration of particles, as well as physical and chemical changes.展开更多
In this study,a CO_(2) capture material in the form of liquid-like adsorbents(LLAs) is developed to overcome the limitations of conventional types of adsorbents.The increase in indoor activities necessitates the captu...In this study,a CO_(2) capture material in the form of liquid-like adsorbents(LLAs) is developed to overcome the limitations of conventional types of adsorbents.The increase in indoor activities necessitates the capture of CO_(2) in enclosed indoor spaces.Indoor spaces require safe and stable materials for CO_(2) capture because humans are present in these spaces.Solid adsorbents are mainly used because liquid absorbents are unsuitable owing to noise and scattering problems.In LLA,the liquid absorbent assembled by carbon nanotubes(CNTs) is solidified and prevented from flowing and scattering indoor.LLAs present to maintain 95% of initial capacity after recycling 20 times,and have characteristics that can be regenerated in a low temperature heat source(80 to 120℃) and moisture resistance.This work not only provides indoor useable CO_(2) capture materials,but also offers a new prospect in the field of adsorbents.展开更多
During the past few decades, both positive and negative aspects of indoor air movement on human comfort perception have been studied. However, most research has focused on collecting empirical evidence to support the ...During the past few decades, both positive and negative aspects of indoor air movement on human comfort perception have been studied. However, most research has focused on collecting empirical evidence to support the potential application of airflows in practice. In this context, numerous studies have encouraged the use of moving air to promote comfort in warm environments, especially with regard to the application of dynamic airflows. Through these studies, the effects of different airflow parameters(such as air velocity, turbulence intensity, and fluctuation frequency) on human comfort perception have gradually been identified and even quantified. This article aims to summarize the progress in the literature concerning dynamic characteristics and comfort assessment of airflows in four main sections: demand for indoor airflows, parameters of indoor airflows, comfort assessment of indoor airflows, and dynamic airflows and their application.This paper will hopefully aid the understanding of human perception of indoor airflows and guide future research.展开更多
Objective Evidence on potential cardiovascular benefits of personal-level intervention among the elderly exposed to high levels of particulate matter(PM)remains limited.We aimed to assess improvements in surrogate mar...Objective Evidence on potential cardiovascular benefits of personal-level intervention among the elderly exposed to high levels of particulate matter(PM)remains limited.We aimed to assess improvements in surrogate markers of cardiovascular injury in vulnerable populations at risks by using indoor air filtration units.Methods We conducted a randomized crossover trial for 2 separate 2-week air filtration interventions in 20 households of patients with stable chronic obstructive pulmonary disease and their partners in the winter of 2013,with concurrent measurements of indoor PM.The changes in biomarkers indicative of cardiac injury,atherosclerosis progression and systemic inflammation following intervention were evaluated using linear mixed-effect models.Results In the analysis,average levels of indoor PM with aerodynamic diameters<2.5µm(PM2.5)decreased significantly by 59.2%(from 59.6 to 24.3µg/m3,P<0.001)during the active air filtration.The reduction was accompanied by improvements in levels of high-sensitivity cardiac troponin I by−84.6%(95%confidence interval[CI]:−90.7 to−78.6),growth differentiation factor-15 by−48.1%(95%CI:−31.2 to−25.6),osteoprotegerin by−65.4%(95%CI:−56.5 to−18.7),interleukin-4 by−46.6%(95%CI:−62.3 to−31.0)and myeloperoxidase by−60.3%(95%CI:−83.7 to−3.0),respectively.Conclusion Indoor air filtration intervention may provide potential cardiovascular benefits in vulnerable populations at risks.展开更多
To analyze the thermal comfort and indoor air quality (IAQ) in a medium-sized mechanically ventilated gymnasium in Beijing,a field study was carried out. PHOENICS,one of the CFD software,was chosen to simulate the dis...To analyze the thermal comfort and indoor air quality (IAQ) in a medium-sized mechanically ventilated gymnasium in Beijing,a field study was carried out. PHOENICS,one of the CFD software,was chosen to simulate the distribution of the indicators of indoor air in the gymnasium to check the air-conditioning parameters reasonable or not. And there was a questionnaire for audiences and staff about the acceptance and satisfaction of the thermal comfort,simultaneously,some environmental parameters were monitored. Then an experiment was carried out in gymnasium with the plate sedimentation to the biological aerosol in the air. Finally,the thermal comfort and IAQ in the gymnasium were assessed based on the results of above questionnaire survey and measurements. The results show that most parameters of the environmental are within the standard limits of thermal comfort and IAQ in the monitored period,and the biological contaminants initially come from human beings. The main species in the gymnasium are streptobacillus,coccus,cladosporium,penicillium and neurospora.展开更多
文摘This study aims to optimize the influence of the inlet inclination angle on the Indoor Air Quality(IAQ),heat,and temperature distribution in mixed convection within a two-dimensional square cavityfilled with an air-CO_(2)mixture.The air-CO_(2)mixture enters the cavity through two inlet openings positioned at the top wall,which is set at the ambient temperature(TC).Three values of the Reynolds numbers,ranging from 1000 to 2000,are considered,while the Prandtl number is kept constant(Pr=0.71).The temperature distribution and streamlines are shown for Rayleigh number(Ra)equal to 104,three inlet inclination anglesϕ(0,π/6 andπ/4)and three CO_(2)concentrations values(1500,2500,3500 ppm)applied at both hot vertical walls(maintained at a constant temperature TH).Afinite volume method is used under the assumption of two-dimensional laminarflow to solve the NavierStokes and energy equations.The results indicate that inlet inclination angle has an impact on the indoor air quality(IAQ),which,in turn,affects the heat transfer distribution and thermal comfort within the cavity.
基金supported by the Project“Entrepreneurial competences and excellence research in doctoral and postdoctoral programs-ANTREDOC”,project cofounded by the European Social Fund financing agreement No.56437/24.07.2019.
文摘The amount of moisture in the air is represented by relative humidity(RH);an ideal level of humidity in the interior environment is between 40%and 60%at temperatures between 18°and 20°Celsius.When the RH falls below this level,the environment becomes dry,which can cause skin dryness,irritation,and discomfort at low temperatures.When the humidity level rises above 60%,a wet atmosphere develops,which encourages the growth of mold and mites.Asthma and allergy symptoms may occur as a result.Human health is harmed by excessive humidity or a lack thereof.Dehumidifiers can be used to provide an optimal level of humidity and a stable and pleasant atmosphere;certain models disinfect and purify the water,reducing the spread of bacteria.The design and implementation of a client-server indoor and outdoor air quality monitoring application are presented in this paper.The Netatmo station was used to acquire the data needed in the application.The client is an Android application that allows the user to monitor air quality over a period of their choosing.For a good monitoring process,the Netatmo modules were used to collect data from both environments(indoor:temperature(T),RH,carbon dioxide(CO_(2)),atmospheric pressure(Pa),noise and outdoor:T and RH).The data is stored in a database,using MySQL.The Android application allows the user to view the evolution of the measured parameters in the form of graphs.Also,the paper presents a prediction model of RH using Azure Machine Learning Studio(Azure ML Studio).The model is evaluated using metrics:Mean Absolute Error(MAE),Root Mean Squared Error(RMSE),Relative Absolute Error(RAE),Relative Squared Error(RSE)and Coefficient of Determination(CoD).
文摘Individuals spend 90% of their time indoors, primarily at home or at work. Indoor environmental factors have a significant impact on human well-being. It was a longitudinal study that assessed the major factors that reduce indoor air quality, namely particulate matter, and bio-aerosols, using low-cost sensors and the settle plate method, respectively also to determine the effect of atmospheric parameters and land use patterns in households of commercial, industrial, residential, slum, and rural areas of the city. PM2.5 concentration levels were similar in most parts of the day across all sites. PM10.0 concentration levels increased indoors in a commercial area. PM2.5 concentration showed a negative correlation with temperature and a positive correlation with relative humidity in some areas. Very high values of PM2.5 concentration and PM10.0 concentration have been observed in this study, inside households of selected rural and urban areas. Pathogenic gram-positive cocci, gram-positive rods, Aspergillus, and Mucor species were the most common bacterial and fungal species respectively found inside households. This study examined particulate matter concentration along with bio-aerosols, as very less studies have been conducted in Jaipur the capital of Rajasthan, a state in the western part of India which assessed both of these factors together to determine the indoor air quality. Rural households surrounding the periphery of the city were found to have similar pollution levels as urban households. So, this study may form the basis for reducing pollution inside households and also for taking suitable measures for the reduction of pollution in the indoor environment.
文摘Background,aim,and scope Owing to the rapid development of modernisation and urbanisation,living standards have gradually improved.However,the widespread use of high-energy-consuming indoor appliances and furniture has made indoor environments a primary environmental problem affecting human health.Sick building syndrome(SBS)and building-related illness(BRI)have occurred,and indoor air conditions have been extensively studied.Common indoor pollutants include CO,CO_(2),volatile organic compounds(VOCs)(such as the formaldehyde and benzene series),NOx(NO and NO_(2)),and polycyclic aromatic hydrocarbons(PAHs).VOCs have replaced SO_(2)as the“The Fourteenth Five-Year Plan”urban air quality assessment new indicators.Indoor VOCs can cause diseases such as cataract,asthma,and lung cancer.To protect human health,researchers have proposed several indoor air purification technologies,including adsorption,filtration,electrostatic dust removal,ozonation,and plant purification.However,each technology has drawbacks,such as high operating costs,high energy consumption,and the generation of secondary waste or toxic substances.Plant degradation of VOCs as a bioremediation technology has the characteristics of low cost,high efficiency,and sustainability,thereby becoming a potential green solution for improving indoor air quality.This study introduces the research status and mechanism of plant removal of indoor VOCs and provides an experimental basis and scientific guidance for analysing the mechanism of plant degradation of pollutants.Materials and methods This study reviews studies on the harm caused by indoor pollutants to human health and related sources,mainly investigating the degradation of indoor formaldehyde,BTEX(benzene,toluene,ethylbenzene,and xylene)plant mechanisms,and research results.Results Plants can remove VOCs via stomatal and non-stomatal adsorption,interfoliar microbial,rhizosphere microbial,and growth media.Benzene,toluene,and xylene(BTX)are adsorbed by pores,hydroxylated into fumaric acid,and then removed into CO_(2) and H_(2)O by TCA.Formaldehyde enters plant leaves through the stomata and epidermal waxy substances and is adsorbed.After the two steps of enzymatic oxidation,formic acid and CO_(2) are generated.Finally,it enters the Calvin cycle and removes glucose and other nontoxic compounds.Discussion The non-stomatal degradation of VOCs can be divided into adsorption by cuticular wax and active adsorption by plant surface microorganisms.The leaf epidermal waxy matter content and the lipid composition of the epidermal membrane covering the plant surface play important roles in the non-stomatal adsorption of indoor air pollutants.The leaf margin of a plant is an ecological environment containing various microbial communities.The endophytic and inoculated microbiota in plant buds and leaves can remove VOCs(formaldehyde and BTEX).Formaldehyde can be directly absorbed by plant leaves and converted into organic acids,sugars,CO_(2) and H_(2)O by microbes.Bioremediation of indoor VOCs is usually inefficient,leading to plant toxicity or residual chemical substance volatilisation through leaves,followed by secondary pollution.Therefore,plants must be inoculated with microorganisms to improve the efficiency of plant degradation of VOCs.However,the effectiveness of interfoliar microbial removal remains largely unknown and several microorganisms are not culturable.Therefore,methods for collecting,identifying,and culturing microorganisms must be developed.As the leaf space is a relatively unstable environment,the degradation of VOCs by rhizosphere microorganisms is equally important,and formaldehyde is absorbed more by rhizosphere microorganisms at night.The inoculation of bacteria into the rhizosphere improves the efficiency of plants in degrading VOCs.However,most of these studies were conducted in simulation chambers.To ensure the authenticity of these conclusions,the ability of plants to remove indoor air pollutants must be further verified in real situations.Conclusions Plant purification is an economical,environment-friendly,and sustainable remediation technology.This review summarises the mechanisms of VOC plant degradation and presents its limitations.Simultaneously,it briefly puts forward a plant selection scheme according to different temperatures,light,and specific VOCs that can be absorbed to choose the appropriate plant species.However,some studies have denied the purification effect of plants and proposed that numerous plants are required to achieve indoor ventilation effects.Therefore,determining the ability of plants to remove indoor VOCs requires a combination of realistic and simulated scenarios.Recommendations and perspectives Plants and related microorganisms play an important role in improving indoor air quality,therefore,the effect of plants and the related microorganisms on improving indoor air quality must be studied further and the effect of plants on indoor VOCs will be the focus of future research.
文摘Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using an MQ2 gas detector,and microcontroller/Arduino-Uno.The design steps included bonding and connecting readymade sensors,coding,and finally testing the device.Testing has been conducted in Environment and Pollution Engineering Department laboratories,at the Technical Engineering College of Kirkuk.This study proposed the use of an MQ2 sensor for multi-gas rate detection which can exist indoors.The system uses also a DHT22 sensor for measuring environment temperature and humidity.The sensors are connected to Arduino and LCD to present data on LCD by powering the system with external power.Overall,the testing was conducted,and the device served as a measuring tool for indoor air as an accurate multi-gas rate detector.
文摘Environmental monitoring of airborne formaldehyde (FA) using sensitive methodologies is fundamental to prevent health risks. The objective of this study was to compare three different FA monitoring methods during the daily activities of an anatomic pathology laboratory. Daily eight-hour measurements deriving from Radiello® passive diffusive samplers (PDS), NEMo XT continuous optical sensor (COS), and multi-gas 1512 photoacoustic monitor (MPM) were simultaneously compared over a period of 14 working days. Given the different daily distributions of the measurements performed by the three devices, all measurements were time-aligned for comparison purposes. The 95% limit of agreement (LOA) method was applied to estimate the degree of concordance of each device with respect to the others. Formaldehyde arithmetic mean measured using PDS was 32.6 ± 10.4 ppb (range: 19.8 - 62.7). The simultaneous measures performed by COS and MPM were respectively 42.4 ± 44.8 ppb (range: 7.0 - 175.0) and 189.0 ± 163.7 ppb (range: 40.0 - 2895.4). The MPM geometric mean (171.3 ppb) was approximately five times higher than those derived from COS (32.3 ppb) and PDS (31.4 ppb). The results of the LOA method applied to log-transformed FA data showed the same systematic discrepancies between MPM and the other two devices. A good agreement between PDS and COS could lead to a tailored approach according to the individual specificity of these techniques. This tool may be useful for accurately assessing the risk of FA exposure among healthcare workers. However, the limited specificity of the MPM does not support its use as a monitoring method for FA in the workplace.
文摘Study Objective: The purpose of the study is to present independent laboratory testing for a novel technology in air and on surfaces. Since 2020, public health goals have focused on improving indoor air quality. This includes protection from airborne pathogens, such as tuberculosis, RSV, SARS-CoV-2, common cold or influenza viruses, measles, and others. Engineering controls are highly effective at reducing hazardous pathogens found in indoor air and from recontamination of surfaces. This occurs from a continuous cycle of settling of small, sustained airborne pathogens, which may become dehumidified, becoming airborne again, carried by room air currents around indoor spaces, then repeating the cycle. Methods: The novel technology utilizes a catalytic process to produce safe levels of hydrogen peroxide gas that are effective in reducing pathogens in the air and on surfaces. Air testing was performed with the MS2 bacteriophage, the test organism for ASHRAE standard 241, and methicillin-Resistant Staphylococcus aureus (MRSA). Surface testing was performed with SARS-COV-2 (Coronavirus COVID-19) and H1N1 (Influenza). Typical ventilation and filtration does not effectively remove disbursed pathogens from the entire facility, due to inconsistent air circulation and surface deposits of pathogens. Results: MS2 was reduced by 99.9%;MRSA was reduced by 99.9%;SARS-CoV-2 was reduced by 99.9%;H1N1 was reduced by 99.9%. Conclusion: This novel catalytic converter reduces a variety of pathogens in the air (99%) and on surfaces (99%), by actively disinfecting with the introduction of gaseous hydrogen peroxide. This active disinfection provides a strong solution for protecting the entire facility and its occupants.
文摘This research focuses on the evaluation of diverse approaches for removing formaldehyde from indoor environments,which is a significant concern for indoor air quality.The study systematically examines physical,chemical,and biological methods to ascertain their effectiveness in formaldehyde mitigation.Physical methods,including air circulation and adsorption,particularly with activated carbon and molecular sieves,are assessed for their efficiency in various concentration scenarios.Chemical methods,such as photocatalytic oxidation using titanium dioxide and plasma technology,are analyzed for their ability to decompose formaldehyde into non-toxic substances.Additionally,biological methods involving plant purification and microbial transformation are explored for their eco-friendly and sustainable removal capabilities.The paper concludes that while each method has its merits,a combined approach may offer the most effective solution for reducing indoor formaldehyde levels.The study underscores the need for further research to integrate these methods in a practical,cost-effective,and environmentally sustainable manner,highlighting their potential to improve indoor air quality significantly.
基金The National Natural Science Foundation of China(No.50878078)
文摘To study the indoor air qualities(IAQ)of large commercial office buildings in Hunan province of China and the corresponding improvement methods,the IAQ of a large commercial office building in Changsha in July,2008,is investigated.A questionnaire survey and field tests are used to collect data.According to the data of twelve rooms in this building,objective evaluation and the subjective evaluation of the IAQ are obtained.Almost all of the environmental parameters in these rooms basically meet the standards of the objective evaluation.But the average concentration of carbon dioxide in most rooms cannot reach the value of the cleanliness standards,1 255 mg/m^3.The average acceptability of the IAQ in these rooms is 71%,which is lower than the value of the ASHRAE 55—1992 standards,80%.The proper increase in the wind speed and the indoor fresh air supply can greatly improve the objective evaluation and the subjective evaluation of the IAQ.
文摘A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 ±1.53 mg/m^3) compared to outdoor air (0.71± 0.46 mg/m^3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building.
文摘The environmental air quality is one of the important problems of people′s concern. The study on human exposure to air pollutants provides an important basis for the nuprorement of human health effects. The questionnaire about time activity patterns includes questions about time spent in the houses, personal activities, indoor combustion sources, information about hobbies, (e.g. smoking), home repairing and decorating materials, and personal product use and so on. The questionnaire was conducted with 662 respondents over 16 years of age in Tianjin, China from fall 1995 to summer 1996. The results of the investigation show that 84% of people′s activities happen indoors, and 58% in family. The field researches of air pollutants monitoring of the most important air pollutants either indoors or outdoors, including carbon monoxide (CO), formaldehyde (HCHO), inhaled particulate (IR), and Benzpyrene(Bap), were carried out in winter and summer from 1995 to 1996. The results of the study on human exposure to four selected air pollutants show that indoor sources and their air pollution cause relatively high exposure in the total air pollution exposures. For example, only the exposure indoors at home is 71.0%,60.3%, 69.4% and 74.0% respectively for CO, HCHO, IR and Bap in the total air pollution exposure.
基金supported by a research grant from the Research Grant Council of the Hong Kong SAR Government, China
文摘This is the first detailed characterization of the airborne bacterial profiles in indoor environments. Two restaurants were selected for this study. Fifteen genera of bacteria were isolated from each restaurant and identified by three different bacterial identification systems including MIDI, Biolog and Riboprinter. The dominant bacteria of both restaurants were Gram-positive bacteria in which Micrococcus and Bacillus species were the most abundant. Most bacteria identified were representative species of skin and respiratory tract of human, and soil. Although the bacterial levels in these two restaurants were below the limit of the Hong Kong Indoor Air Quality Objective (HKIAQO) Level 1 standard (i.e., 〈 500 cfu/m^3), the majority of these bacteria were opportunistic pathogens. These results suggested that the identity of airborne bacteria should also be included in the IAQ to ensure there is a safety guideline for the public.
基金supported by a Kawasaki Medical School Research Grant(28B051)
文摘Objective The changes in serum adipokines and cytokines related to oxidative stress were examined during 3 months ‘Off to On’ and ‘On to Off’ periods using negatively charged particle-dominant indoor air conditions(NCPDIAC).Methods Seven volunteers participated in the study,which included ‘OFF to 3 months ON’ periods(ON trials) for a total of 16 times,and ‘ON to 3 months OFF’(OFF trials) periods for a total of 13 times.Results With the exception of one case,serum amyloid A(SAA) levels decreased significantly during the ON trials.Conclusion Considering that SAA is an acute phase reactive protein such as C reactive protein(CRP),this observed decrease might indicate the prevention of cardiovascular and atherosclerotic changes,since an increase in high-sensitive CRP is associated with the subsequent detection of these events.
文摘With 1 185 pi eces of questionnaire, it is found that in China, people take fresh air, odor, e tc., as well as indoor air temperature, humidity, as the most important indoor a ir parameters. It is also found that there is a significant sensitivity differen ce in indoor environment between southerners and northerners in China. People fr om different regions have different demands for their working and living environ ment. Therefore, as a good design of air conditioning system, it is strongly rec ommended that the different demands of people from different regions should be t aken into consideration.
基金Projects 50474050 supported by the National Natural Science Foundation of China 20040533011 by the Doctoral Fund of Ministry of Education of China
文摘Experiments on the behavior of airborne microparticle sediments and their adhesion on glass slides were conducted in a laboratory located on the first floor of a teaching building. Clean tiles and glass slides were placed at different angles (0°, 45° and 90°) with respect to the horizontal plane in the laboratory. The sedimentation of microparticles was investigated at certain time intervals (1 d, 3 d, l0 d and 30 d). The results of testing, at day 30, show that the diameters of particles on the horizontal tiles varied from 20 to 80 μm; few particles with diameter less than 0.5 μm or greater than 100 μm were found. The amount of particle sediment on all the slides increased along over time, while the average diameter of particles was not correlated with time, nor with the angle of placement. The maximum particle size, the total particle surface area, the total perimeter of all particles and the cover ratio of light (the proportion of total area of particles to the observed area of the slides surfaces) did not change significantly within the first 10 days. Inspection of all the samples for the last 20 days, however, showed that these variables increased substantially with the passage of time and were in reverse proportion to the placement angles, which indicates a concentration of particles, as well as physical and chemical changes.
基金supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT)(Grant number:2020R1A5A1018153 and No.2020R1A6A3A01095950)。
文摘In this study,a CO_(2) capture material in the form of liquid-like adsorbents(LLAs) is developed to overcome the limitations of conventional types of adsorbents.The increase in indoor activities necessitates the capture of CO_(2) in enclosed indoor spaces.Indoor spaces require safe and stable materials for CO_(2) capture because humans are present in these spaces.Solid adsorbents are mainly used because liquid absorbents are unsuitable owing to noise and scattering problems.In LLA,the liquid absorbent assembled by carbon nanotubes(CNTs) is solidified and prevented from flowing and scattering indoor.LLAs present to maintain 95% of initial capacity after recycling 20 times,and have characteristics that can be regenerated in a low temperature heat source(80 to 120℃) and moisture resistance.This work not only provides indoor useable CO_(2) capture materials,but also offers a new prospect in the field of adsorbents.
文摘During the past few decades, both positive and negative aspects of indoor air movement on human comfort perception have been studied. However, most research has focused on collecting empirical evidence to support the potential application of airflows in practice. In this context, numerous studies have encouraged the use of moving air to promote comfort in warm environments, especially with regard to the application of dynamic airflows. Through these studies, the effects of different airflow parameters(such as air velocity, turbulence intensity, and fluctuation frequency) on human comfort perception have gradually been identified and even quantified. This article aims to summarize the progress in the literature concerning dynamic characteristics and comfort assessment of airflows in four main sections: demand for indoor airflows, parameters of indoor airflows, comfort assessment of indoor airflows, and dynamic airflows and their application.This paper will hopefully aid the understanding of human perception of indoor airflows and guide future research.
基金This work was supported by Beijing Natural Science Foundation(7222246)Royal Dutch Philips Electronics Ltd.(Grant NL18-2100478471).
文摘Objective Evidence on potential cardiovascular benefits of personal-level intervention among the elderly exposed to high levels of particulate matter(PM)remains limited.We aimed to assess improvements in surrogate markers of cardiovascular injury in vulnerable populations at risks by using indoor air filtration units.Methods We conducted a randomized crossover trial for 2 separate 2-week air filtration interventions in 20 households of patients with stable chronic obstructive pulmonary disease and their partners in the winter of 2013,with concurrent measurements of indoor PM.The changes in biomarkers indicative of cardiac injury,atherosclerosis progression and systemic inflammation following intervention were evaluated using linear mixed-effect models.Results In the analysis,average levels of indoor PM with aerodynamic diameters<2.5µm(PM2.5)decreased significantly by 59.2%(from 59.6 to 24.3µg/m3,P<0.001)during the active air filtration.The reduction was accompanied by improvements in levels of high-sensitivity cardiac troponin I by−84.6%(95%confidence interval[CI]:−90.7 to−78.6),growth differentiation factor-15 by−48.1%(95%CI:−31.2 to−25.6),osteoprotegerin by−65.4%(95%CI:−56.5 to−18.7),interleukin-4 by−46.6%(95%CI:−62.3 to−31.0)and myeloperoxidase by−60.3%(95%CI:−83.7 to−3.0),respectively.Conclusion Indoor air filtration intervention may provide potential cardiovascular benefits in vulnerable populations at risks.
基金Project(2006BAJ02A10) supported by the National Key Technologies R & D Program of China
文摘To analyze the thermal comfort and indoor air quality (IAQ) in a medium-sized mechanically ventilated gymnasium in Beijing,a field study was carried out. PHOENICS,one of the CFD software,was chosen to simulate the distribution of the indicators of indoor air in the gymnasium to check the air-conditioning parameters reasonable or not. And there was a questionnaire for audiences and staff about the acceptance and satisfaction of the thermal comfort,simultaneously,some environmental parameters were monitored. Then an experiment was carried out in gymnasium with the plate sedimentation to the biological aerosol in the air. Finally,the thermal comfort and IAQ in the gymnasium were assessed based on the results of above questionnaire survey and measurements. The results show that most parameters of the environmental are within the standard limits of thermal comfort and IAQ in the monitored period,and the biological contaminants initially come from human beings. The main species in the gymnasium are streptobacillus,coccus,cladosporium,penicillium and neurospora.