期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Study on Air Pollutant Concentration inside Railway Tunnels
1
作者 黄美荣 杨立新 赵海恒 《Journal of Modern Transportation》 2000年第2期129-135,共7页
This paper presents a one-dimensional unsteady flow model and a numerical procedure based on the model. Comparisons between the theory and full scale experiments in a railway tunnel show that the model is capable of p... This paper presents a one-dimensional unsteady flow model and a numerical procedure based on the model. Comparisons between the theory and full scale experiments in a railway tunnel show that the model is capable of produce precise predictions for piston wind and pollutant concentration in railway tunnels. 展开更多
关键词 air pollutant concentration piston wind unsteady flow TUNNEL
下载PDF
Investigation of air pollution concentration in Kathmandu valley during winter season
2
作者 KONDO Akira KAGA Akikazu +4 位作者 IMAMURA Kiyoshi INOUE Yoshio SUGISAWA Masahiko SHRESTHA Manohar Lal SAPKOTA Balkrishan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第6期1008-1013,共6页
The monthly concentrations of NO2, NOx, SO2 and O3 measured by a passive sampler from February 2003 to January 2004 showed that the air pollution during the winter season in Kathmandu valley was higher than the summer... The monthly concentrations of NO2, NOx, SO2 and O3 measured by a passive sampler from February 2003 to January 2004 showed that the air pollution during the winter season in Kathmandu valley was higher than the summer season. The O3 level was found the highest during April, May and June due to strong radiation. The hourly concentrations of NO2, NOx, O3 and suspended particulate matter(SPM) were also measured by automatic instruments on December 2003. Temperature at the height of 60 m and 400 m at Raniban Mountain in the northwest of Kathmandu valley was measured on February 2001 in the winter season and the average potential temperature gradient was estimated from observed temperature. Wind speed was also measured at the department of hydrology, airport section, from 18 February to 6 March 2001. It was found that the stable layer and the calm condition in the atmosphere strongly affected the appearance of the maximum concentrations of NO2 and SPM in the morning, and that the unstable layer and the windy condition in the atmosphere was considerably relevant to the decrease of air pollution concentrations at daytime. The emission amounts of NOx, HCs and total suspended particle(TSP) from transport sector in 2003 were estimated from the increasing rate of vehicles on the basis of the emission amounts in 1993 to be 3751 t/a, 30570 t/a and 1317 t/a, respectively. The diurnal concentrations in 2003 calculated by the two-layers box model reproduced the characteristics of air pollution in Kathmandu valley such as the maximum value of O3 and its time, the maximum value of NO in the morning, and the decrease of NO and NO2 at daytime. The comparison with the concentrations in 1993 calculated suggested that the main cause of air pollution was the emission from transport sector. 展开更多
关键词 air pollution concentration Kathmandu vallay box model
下载PDF
Pollution levels and characteristics of phthalate esters in indoor air in hospitals 被引量:4
3
作者 Xueqing Wang Min Song +3 位作者 Min Guo Chenchen Chi Feifei Mo Xueyou Shen 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第11期67-74,共8页
The concentrations of phthalate esters(PAEs) in Chinese hospitals were investigated by simultaneously determining concentrations of gas- and particle-phase PAEs. PAEs were detected in two third-class first-grade hos... The concentrations of phthalate esters(PAEs) in Chinese hospitals were investigated by simultaneously determining concentrations of gas- and particle-phase PAEs. PAEs were detected in two third-class first-grade hospitals, two second-class first-grade hospitals, and a community health service center. Hospital drugstores had the highest concentration(24.19 μg/m3), which was 1.54 times that of newly decorated houses. The second highest concentration was found in the transfusion rooms, averaging 21.89 μg/m3; this was followed by the concentrations of PAEs in the nurse's workstations, the wards, and the doctor's offices, with mean concentrations of 20.66, 20.0, and 16.92 μg/m3, respectively. The lowest concentrations were found in the hallways(16.30 μg/m3). Of the six different kinds of PAEs found, major pollutants included diethyl phthalates, dibutyl phthalates, butylbenzyl phthalates and di(2-ethylhexyl) phthalates, comprising more than 80% of all PAEs present.Meanwhile, a comparison between different wards showed that PAE concentrations in the maternity wards were 1.63 times higher than in the main wards. Based on known health hazards, our results suggest that the PAEs seriously influence the health of the pregnant women and babies; therefore, it is of great importance to take the phthalate concentrations in hospitals into consideration. In addition, hospital indoor air was more seriously contaminated than the air of newly decorated houses. 展开更多
关键词 air pollution Hospital Indoor air Phthalate concentrations
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部