期刊文献+
共找到2,613篇文章
< 1 2 131 >
每页显示 20 50 100
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
1
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
2
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump 被引量:7
3
作者 董建锴 姜益强 +1 位作者 姚杨 张雪丹 《Journal of Central South University》 SCIE EI CAS 2011年第6期2163-2169,共7页
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho... To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting. 展开更多
关键词 逆循环除霜 除霜方法 空气源热泵 热能储存 经营业绩 对比实验 持续时间 能源消耗
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
4
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 天津 气源热泵系统 供暖 运行性能 除霜
下载PDF
Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter 被引量:2
5
作者 庄兆意 张承虎 +1 位作者 王海燕 孙德兴 《Transactions of Tianjin University》 EI CAS 2010年第6期461-466,共6页
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running... Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multiple units but different parallel operation models, and the operation characteristics of units were analyzed as well. Results show that the single screw water-source heat pump can maintain high COP only at 60%—100% load ratio, COP decreases sharply with the decrease of load ratio, and the units with parallel operation are controlled by the load ratio of a single unit according to the reduction of total load which can keep the average COP at high level within a wide load range. 展开更多
关键词 污水来源 热泵单位 性能(警察) 的系数 部分负担 平行操作
下载PDF
Thermodynamic Simulation of CCP in Air-Cooled Heat Pump Unit with HFCs and CO<sub>2</sub>Trans-Critical 被引量:2
6
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Journal of Power and Energy Engineering》 2018年第9期141-164,共24页
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ... The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2. 展开更多
关键词 air-Cooled heat pump unit Compound Condensation Process (CCP) EXERGY Analysis Method Sanitary Hot Water MATLAB/SIMULINK Software Fluorine Substitute REFRIGERANT R407C/R410A Natural REFRIGERANT CO2
下载PDF
Experiment research on grain drying process in the heat pump assisted fluidized beds 被引量:7
7
作者 JingYang LiWang FiXiang LigeTong HuaSu 《Journal of University of Science and Technology Beijing》 CSCD 2004年第4期373-377,共5页
A heat pump assisted fluidized bed grain drying experimental system wasdeveloped. Based on this system, a serial of experiments was performed under four kinds of air cycleconditions. According to the experimental anal... A heat pump assisted fluidized bed grain drying experimental system wasdeveloped. Based on this system, a serial of experiments was performed under four kinds of air cycleconditions. According to the experimental analysis, an appropriate drying medium-air cycle for theheat pump assisted fluidized bed drying equipment was decided, which is different from the commonlyused heat pump assisted drying system. The experimental results concerning the drying operationperformance of the new system show that the averaged coefficient of performance (COP) can reach morethan 2.5. The economical evaluation was performed and the power consumption for removing a kilogramwater from grains was about 0.485 kW-h/kg (H_2O), which shows its reasonable commercial efficiencyand great application potentiality in future market. 展开更多
关键词 heat pump fluidized bed GRAIN drying air recycle
下载PDF
Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System 被引量:1
8
作者 SU Shun-yu,ZHANG Chun-zhi,CHEN Jian(College of Urban Construction,Wuhan University of Science and Technology,Wuhan,Hubei 430070,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期91-95,共5页
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.... This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary. 展开更多
关键词 air-source heat pump control strategy distributed PARAMETER model CHARGE INVENTORY
下载PDF
Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating
9
作者 李凡 陆高锋 +3 位作者 丁云霄 郑春元 李斌 翟晓强 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期179-187,共9页
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of... A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard. 展开更多
关键词 air source heat pump water heater(ASHPWH) cyclic heating MICROCHANNEL CONDENSER
原文传递
基于ANFIS的太阳能-空气源热泵供暖系统温度控制研究
10
作者 谭心 吴林锋 +3 位作者 虞启辉 刘泽江 王亚辉 孙国鑫 《太阳能学报》 EI CAS CSCD 北大核心 2024年第2期16-22,共7页
针对太阳能-空气源热泵供暖系统运行环境复杂多变,模糊控制器的设计高度依赖人工经验的问题,提出一种基于自适应神经模糊推理系统(ANFIS)改进的模糊控制方法。该方法利用ANFIS在复杂系统建模中的优势,结合供暖系统温度响应特性和实际运... 针对太阳能-空气源热泵供暖系统运行环境复杂多变,模糊控制器的设计高度依赖人工经验的问题,提出一种基于自适应神经模糊推理系统(ANFIS)改进的模糊控制方法。该方法利用ANFIS在复杂系统建模中的优势,结合供暖系统温度响应特性和实际运行数据,建立联合供暖系统变工况ANFIS模型,生成与系统性能适配的模糊规则库并传递给模糊控制器执行。Matlab/Simulink仿真对比试验表明,与单一的模糊控制相比,该方法的控制精度提高了17.65%,调节时间缩短了36.4%,具有更高的控制精度和响应速度。 展开更多
关键词 太阳能 空气源热泵 联合供暖 模糊控制 温度控制 ANFIS
下载PDF
太阳能-空气源热泵牧草干燥系统制热性能研究
11
作者 钱珊珠 杨海巍 +5 位作者 郭文斌 钱丹珠 张清杨 王振彬 屠旭杰 黄长华 《农机化研究》 北大核心 2024年第2期235-241,共7页
以太阳能-空气源热泵牧草干燥系统为研究对象,通过系统不同工作模式的温升、恒温制热试验及带载试验,分析了温升速率、单位温升能耗、COP及除湿效率。研究结果表明:联合制热模式与太阳能单独制热相比,单位温升耗电量降低了86.2%,温升速... 以太阳能-空气源热泵牧草干燥系统为研究对象,通过系统不同工作模式的温升、恒温制热试验及带载试验,分析了温升速率、单位温升能耗、COP及除湿效率。研究结果表明:联合制热模式与太阳能单独制热相比,单位温升耗电量降低了86.2%,温升速率提高了99~112倍。联合制热模式与热泵单独制热试验相比,在温升过程中温升速率降低了7.7%~17.6%,单位温升耗电量降低8.0%;在恒温制热过程中,前者COP比后者提高了6.5%~11.1%,耗电量降低了5.8%~10.7%;在升温制热过程中前者COP比后者提高了6.0%~10.4%,耗电量降低了6.6%~11.1%。联合干燥模式比热泵单独干燥模式的SMER值高19.8%~36.2%。 展开更多
关键词 牧草 太阳能—空气源热泵 干燥系统 制热性能
下载PDF
严寒地区空气源热泵耦合电磁能系统模拟运行研究
12
作者 冯国会 贾敏 +2 位作者 张磊 李旭林 赫娜 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第2期322-329,共8页
目的 为了促进空气源热泵耦合电磁能供热系统在严寒地区住宅建筑中的应用,研究该系统的运行性能和稳定性。方法 以沈阳地区某住宅建筑为例,应用Trnsys软件建立了空气源热泵耦合电磁能供热系统仿真模型,并用实测值对模型进行了验证;深入... 目的 为了促进空气源热泵耦合电磁能供热系统在严寒地区住宅建筑中的应用,研究该系统的运行性能和稳定性。方法 以沈阳地区某住宅建筑为例,应用Trnsys软件建立了空气源热泵耦合电磁能供热系统仿真模型,并用实测值对模型进行了验证;深入探讨空气源热泵耦合电磁能供热系统在供热期的运行特点,并与空气源热泵和电磁能供热系统分别进行比较。结果 空气源热泵耦合电磁能供热系统模型可靠,相对误差可以控制在15%以内;在供热期,室内平均温度可保持在17.97~21.84℃;空气源热泵耦合电磁能供热系统比电磁能供热系统的COP提高了59.17%,空气源热泵耦合电磁能供热系统CO_(2)减排量比空气源热泵和电磁能供热系统分别提高1.47%和59.50%。结论 空气源热泵耦合电磁能供热系统运行和COP变化更为稳定,系统环境效益更佳,室内热舒适性更高。 展开更多
关键词 空气源热泵 电磁能系统 COP 严寒地区 耦合系统
下载PDF
太阳能光热光电技术在高校宿舍的对比研究
13
作者 张春枝 吴宇红 +2 位作者 李涛 雷赢昌 毛前军 《建筑节能(中英文)》 CAS 2024年第6期16-22,79,共8页
针对夏热冬冷地区某高校宿舍用能特征,基于太阳能的两种利用方式分别设计了太阳能光热供能系统和太阳能光电供能系统。利用TRNSYS仿真软件模拟两种供能系统的运行特性,对比了两种系统的组件性能、经济性及减排量。结果表明:除假期时间外... 针对夏热冬冷地区某高校宿舍用能特征,基于太阳能的两种利用方式分别设计了太阳能光热供能系统和太阳能光电供能系统。利用TRNSYS仿真软件模拟两种供能系统的运行特性,对比了两种系统的组件性能、经济性及减排量。结果表明:除假期时间外,太阳能集热单元的集热效率保持在40%左右,年太阳能保证率可达58%;并网光伏发电单元全年发电量为311 394 kW·h,发电量自用率达到70.5%。太阳能光电供能系统的年能耗费用较光热供能系统节省11万元,费用年值减少4.9万元,年碳排放量降低166 t。对光伏安装面积进行优化后可知,光伏安装面积每增加52 m^(2),光伏供能系统费用年值减少2111元。研究结果可为高校宿舍建筑选择适宜的太阳能利用形式提供参考和依据。 展开更多
关键词 高校宿舍 多能互补 太阳能 空气源热泵 节能经济性
下载PDF
具有防融霜装置的蒸发器结霜特性及性能仿真研究
14
作者 龚光彩 安劲霖 +1 位作者 张明发 胡文荃 《太阳能学报》 EI CAS CSCD 北大核心 2024年第4期442-449,共8页
以具有防融霜装置的蒸发器为研究对象,建立基于理想最小防融霜补热量和结霜量无量纲关联式的空气源热泵动态模型,并依据实验数据验证其精确性,通过数值模拟分析不同环境参数对具有防融霜装置的蒸发器性能的影响。结果表明:后置式与跨越... 以具有防融霜装置的蒸发器为研究对象,建立基于理想最小防融霜补热量和结霜量无量纲关联式的空气源热泵动态模型,并依据实验数据验证其精确性,通过数值模拟分析不同环境参数对具有防融霜装置的蒸发器性能的影响。结果表明:后置式与跨越式系统蒸发器换热系数要高于前置式与传统电辅热系统,霜层厚度更小,分布更均匀;当相对湿度一定时,蒸发器换热系数随温度升高而增大;当空气温度不变时,换热系数随相对湿度的下降而减小,霜层更均匀;温度对蒸发器换热系数的影响比相对湿度更大。 展开更多
关键词 空气源热泵 蒸发器 动态模型 仿真模拟 防融霜装置 结霜特性
下载PDF
基于正交试验法的太阳能复合热水系统优化
15
作者 王强 田佳琪 +2 位作者 尹梓壮 李鹏 陈安新 《山东建筑大学学报》 2024年第1期31-38,共8页
为降低生活热水能耗,实现空气源热泵辅助太阳能供热水系统的高效节能运行,选取济南市某高校学生宿舍空气源热泵辅助太阳能供热水系统作为研究对象,利用瞬时系统模拟软件搭建了系统仿真模型,并采用无交互作用的正交试验法,分别以全年系... 为降低生活热水能耗,实现空气源热泵辅助太阳能供热水系统的高效节能运行,选取济南市某高校学生宿舍空气源热泵辅助太阳能供热水系统作为研究对象,利用瞬时系统模拟软件搭建了系统仿真模型,并采用无交互作用的正交试验法,分别以全年系统性能系数和太阳能保证率为优化目标,优化了太阳能集热器面积、集热器倾角、热泵制热功率及水箱容积,并分析其结果的经济性和节能性。结果表明:当以系统性能系数为优化目标时,最优组合中集热器面积为390 m^(2)、集热器倾角为42°、热泵制热功率为50 kW、水箱容积为23.94 m3,而动态费用年值为7.38万元,较天然气系统年节省标煤为17.12 tce;当以太阳能保证率为优化目标时,最优组合中集热器面积为342 m^(2)、集热器倾角为44°、热泵制热功率为35.5 kW、水箱容积为20.58 m3,而动态费用年值为6.56万元,较天然气系统年节省标煤为16.63 tce。 展开更多
关键词 太阳能 空气源热泵 正交试验法 优化研究 动态费用年值
下载PDF
相变储热技术在空气源热泵供暖中的应用研究现状
16
作者 李阳 余萌 +2 位作者 金苏柯 李德锋 殷建新 《城市建筑》 2024年第9期164-168,共5页
空气源热泵技术因具有节能、环保、高效等优点,在我国建筑供暖领域得到了广泛应用。文章分析了空气源热泵系统在供暖过程中存在的问题,介绍了利用相变储热技术优化空气源热泵运行性能的基本方式及原理。通过分析相变材料自身热物性以及... 空气源热泵技术因具有节能、环保、高效等优点,在我国建筑供暖领域得到了广泛应用。文章分析了空气源热泵系统在供暖过程中存在的问题,介绍了利用相变储热技术优化空气源热泵运行性能的基本方式及原理。通过分析相变材料自身热物性以及相变储热单元在系统中的应用,从材料及系统两方面简述了相变储热技术在空气源热泵供暖中的研究现状及进展。最后,得出结论并针对相变储热技术在空气源热泵供暖中的应用难点,对未来发展进行了展望。 展开更多
关键词 空气源热泵 相变储热技术 相变材料 热导率 供暖
下载PDF
基于聚光光伏光热的太阳能供暖系统性能优化
17
作者 王娜 张衡 +2 位作者 楚尚玲 徐梓彭 陈海平 《节能》 2024年第2期1-5,共5页
以北京市某办公建筑为供暖对象,提出由聚光光伏光热单元、光伏单元以及空气源热泵(CPVT-PV-ASHP)耦合的清洁供暖系统。基于Trnsys和Grasshopper平台搭建系统的动态仿真模型和优化模型,以CPVT光伏电池板面积为决策变量,采用超体积计算法(... 以北京市某办公建筑为供暖对象,提出由聚光光伏光热单元、光伏单元以及空气源热泵(CPVT-PV-ASHP)耦合的清洁供暖系统。基于Trnsys和Grasshopper平台搭建系统的动态仿真模型和优化模型,以CPVT光伏电池板面积为决策变量,采用超体积计算法(HypE)求解,探究系统在节能性、经济性和改善热泵性能方面的平衡。结果显示,在空冷型CPVT和水冷型CPVT中光伏电池板面积分别为10.9 m^(2)和2.3 m^(2)时取得最优解。此时系统的一次能源消耗量为-1 016.1千克标准煤,热泵平均能效比(COP)为3.72,投资回报周期为2.95年。与其他系统相比,CPVT-PV-ASHP系统在节约能耗、改善热泵性能等方面优势显著。 展开更多
关键词 聚光光伏光热 空气源热泵 多目标优化
下载PDF
空气源热泵除霜技术研究进展
18
作者 徐鹏 赵靖怡 李朝阳 《制冷与空调》 2024年第4期97-104,共8页
综述国内外空气源热泵除霜技术的研究进展,针对目前对快速除霜和除霜兼顾制热能力等需求以及近些年相变蓄能技术的发展,介绍常规除霜方法的改进措施及目前研究热点,如补气除霜、不停机除霜、超声波除霜和智能除霜等技术。研究发现,研究... 综述国内外空气源热泵除霜技术的研究进展,针对目前对快速除霜和除霜兼顾制热能力等需求以及近些年相变蓄能技术的发展,介绍常规除霜方法的改进措施及目前研究热点,如补气除霜、不停机除霜、超声波除霜和智能除霜等技术。研究发现,研究人员对常规除霜技术的完善一直没有停止,目前在兼顾室内舒适度的同时,空气源热泵除霜效率的提高与系统复杂度、技术要求、成本以及能耗等方面增加的矛盾仍然有待解决。快速除霜和制热不停机除霜是空气源热泵未来除霜技术的发展方向。 展开更多
关键词 空气源热泵 除霜 制热 快速除霜 不停机除霜
下载PDF
超低温空气源热泵与太阳能供热系统在寒冷地区的优化应用
19
作者 李杰 《能源与节能》 2024年第1期37-40,共4页
为了加强对环境的保护,推动可持续发展社会的建设,超低温空气源热泵联合太阳能供热系统被研发出来。该联合系统的应用极大地缓解了当前能源紧张的问题,同时对降低环境污染、提高能源利用率、降低供暖成本也有着积极的作用。基于此,围绕... 为了加强对环境的保护,推动可持续发展社会的建设,超低温空气源热泵联合太阳能供热系统被研发出来。该联合系统的应用极大地缓解了当前能源紧张的问题,同时对降低环境污染、提高能源利用率、降低供暖成本也有着积极的作用。基于此,围绕超低温空气热源泵与太阳能供热系统展开论述,对当前超低温空气源热泵与太阳能联合供热系统结构进行分析,剖析其中所存在的问题,同时针对问题提出超低温空气源热泵与太阳能供热系统的优化方案,将其应用于北方寒冷地区的一建筑当中,并对应用效果进行分析。 展开更多
关键词 超低温 空气热源泵 太阳能 供热系统 优化方案
下载PDF
冷凝器面积对空气源热泵制热性能的影响研究
20
作者 库慧益 向德宁 +4 位作者 侯忠平 林蔚 张楚安 徐帅 吴学红 《包装工程》 CAS 北大核心 2024年第1期28-33,共6页
目的研究低温条件下空气源热泵的烘干性能。方法论文主要采用焓差法研究在换热面积和室外温度(温度为7、−12、−20℃,相对湿度为65%)不同时,空气源热泵的制热量、输入功率、能效等性能。结果在7℃环境中,增加室内侧换热器面积,热泵的制... 目的研究低温条件下空气源热泵的烘干性能。方法论文主要采用焓差法研究在换热面积和室外温度(温度为7、−12、−20℃,相对湿度为65%)不同时,空气源热泵的制热量、输入功率、能效等性能。结果在7℃环境中,增加室内侧换热器面积,热泵的制热量提高了19%,系统能效提升了14%,但输入功率增加了5%;在−12~−20℃环境中,增加室内侧换热器面积,热泵的制热量提升了5%,系统能效提升明显,最大可提升27%,输入功率最大降低为17%。结论增加室内侧换热器面积,系统焓差降低,但是能提高系统在低温下的循环风量,制热性能更加优异。 展开更多
关键词 热泵干燥 低温空气源热泵 换热器面积 制热效果 系统能效
下载PDF
上一页 1 2 131 下一页 到第
使用帮助 返回顶部