期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Application of water loop variable refrigerant flow air-conditioning system in large-scale buildings in northern China
1
作者 孙婷婷 倪龙 +1 位作者 姚杨 马最良 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期197-200,共4页
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va... A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system. 展开更多
关键词 variable refrigerant flow air-conditioning system water loop large-scale building
下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
2
作者 TANG Wen-wu1,2,WANG Han-qing1,2(1.School of Energy Science and Engineering,Central South University,Changsha,Hunan 410083,China 2.School of Civil Engineering,Hunan University of Technology,Zhuzhou,Hunan 412008,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-conditionING refrigerating MACHINE condense HEAT ENTROPY evaluation LS-SVM
下载PDF
Experimental Study of Air Conditioning Unit of Evaporative Cooling Assisted Mechanical Refrigeration 被引量:3
3
作者 HUANG Xiang,XU Fang-cheng,WU Jun-mei(Xi’an polytechnic University,Xi’an,Shaanxi 710048,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期106-110,共5页
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy... The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent. 展开更多
关键词 EVAPORATIVE COOLING mechanical refrigeration air-conditionING unit EER
下载PDF
制冷空调试验装置中传感器的标定 被引量:4
4
作者 郑传经 郑庆伟 +4 位作者 黄承宏 高启明 樊海彬 邱亚林 夏玲 《流体机械》 CSCD 北大核心 2006年第1期77-79,共3页
分析了传感器定期标定的必要性,介绍了制冷空调试验装置中常用的各种类型传感器的标定方法。
关键词 制冷空调试验装置 标定 铂电阻 热电偶补偿导线 压力传感器
下载PDF
Evaluation of non-azeotropic mixtures containing HFOs as potential refrigerants in refrigeration and high-temperature heat pump systems 被引量:3
5
作者 ZHANG ShengJun, WANG HuaiXin & GUO Tao Department of Thermal Energy and Refrigeration Engineering, Tianjin University, Tianjin 300072, China 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第7期1855-1861,共7页
With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed o... With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed of HFOs (HFO-1234yf, HFO-1234ze(z), HFO-1234ze(e) and HFO-1234zf) are developed to substitute for HFC-134a and CFC-114 in air-conditioning and high-temperature heat pump systems, respectively. The cycle performances were evaluated by an improved theoretical cy-cle evaluation methodology. The results showed that all the mixtures proposed herein were favorable refrigerants with excel-lent thermodynamic cycle performances. M1A presented lower discharge temperature and pressure ratio and higher COPc than that of HFC-134a. The volumetric cooling capacity was similar to HFC-134a. It can be served as a good environmentally friendly alternative to replace HFC-134a. M3H delivered similar discharge temperature as CFC-114 did. And the COPh was 3% higher. It exhibits excellent cycle performance in high-temperature heat pump and is a promising refrigerant to substitute for CFC-114. And the gliding temperature differences enable them to exhibit better coefficient of performance by matching the sink/source temperature in practice. Because the toxicity, flammability and other properties are not investigated in detail, ex-tensive toxicity and flammability testing needs to be conducted before they are used in a particular application. 展开更多
关键词 hydrofluoro-olefin NON-AZEOTROPIC mixtures refrigerANT air-conditionING system high-temperature heat pump
原文传递
一种冷冻冷藏行业用制冷压缩机组COP测试仪
6
作者 房玉明 姜典举 +2 位作者 王吉帅 韩强 王晓杰 《冷藏技术》 2018年第1期55-59,共5页
本文介绍了一种新型压缩机组COP测试仪,用于冷冻冷藏现场不稳定工况下的压缩机COP测试。在实验室稳定工况下对新型压缩机组COP测试仪进行了测量验证,结果表明其测量结果准确。对两家使用年限不同的超市制冷压缩机组进行现场测量,测试结... 本文介绍了一种新型压缩机组COP测试仪,用于冷冻冷藏现场不稳定工况下的压缩机COP测试。在实验室稳定工况下对新型压缩机组COP测试仪进行了测量验证,结果表明其测量结果准确。对两家使用年限不同的超市制冷压缩机组进行现场测量,测试结果符合压缩机组使用和性能衰减规律。 展开更多
关键词 冷冻冷藏 制冷压缩机组 不稳定工况 COP测试仪
下载PDF
Finite time thermodynamic analysis and optimization of water cooled multi-spilit heat pipe system(MSHPS)
7
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Energy and Built Environment》 2022年第3期373-383,共11页
This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data cen... This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems. 展开更多
关键词 Thermodynamic simulation Finite time thermodynamic analysis Exergy method IDC room Heat pipe air-conditioning system SIMULINK software refrigerant flow distribute characteristic Energy saving potential
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部