期刊文献+
共找到19,608篇文章
< 1 2 250 >
每页显示 20 50 100
Construction and realization of the knowledge base and inference engine of an IDSS model for air-conditioning cooling/heating sources selection
1
作者 刘颖 王如竹 +1 位作者 李云飞 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2003年第2期136-141,共6页
The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowle... The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building. 展开更多
关键词 air-conditioning cooling/heating sources intelligent decision support system knowledge base inference engine
下载PDF
Application of water loop variable refrigerant flow air-conditioning system in large-scale buildings in northern China
2
作者 孙婷婷 倪龙 +1 位作者 姚杨 马最良 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期197-200,共4页
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va... A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system. 展开更多
关键词 variable refrigerant flow air-conditioning system water loop large-scale building
下载PDF
Laves phase hydrogen storage alloys for super-high-pressure metal hydride hydrogen compressors 被引量:4
3
作者 GUO Xiumei WANG Shumao LIU Xiaopeng LI Zhinian LU Fang MI Jing HAO Lei JIANG Lijun 《Rare Metals》 SCIE EI CAS CSCD 2011年第3期227-231,共5页
Ti-Cr- and Ti-Mn-based alloys were prepared to be low- and high-pressure stage metals for a double-stage super-high-pressure metal hydride hydrogen compressor. Their crystallographic characteristics and hydrogen stora... Ti-Cr- and Ti-Mn-based alloys were prepared to be low- and high-pressure stage metals for a double-stage super-high-pressure metal hydride hydrogen compressor. Their crystallographic characteristics and hydrogen storage properties were investigated. The alloy pair Ti0.9Zr0.1Mn1.4- Cr0.35V0.2Fe0.05/TiCr1.55Mn0.2Fe0.2 was optimized based on the comprehensive performance of the studied alloys. The product hydrogen with a pressure of 100 MPa could be produced from 4 MPa feed gas when hot oil was used as a heat reservoir. 展开更多
关键词 hydrogen storage alloys hydrides Laves phase compressors HYDROGEN
下载PDF
Study on effect analysis and parameter optimizing of stepless capacity control system on reciprocating compressors 被引量:2
4
作者 王瑶 Zhang Jinjie +1 位作者 Zhou Chao Liu Wenhua 《High Technology Letters》 EI CAS 2018年第1期1-9,共9页
An improved model of reciprocating compressor operation cycle with a stepless capacity control system is presented and influence of the key parameters of the system is evaluated. In the stepless capacity control syste... An improved model of reciprocating compressor operation cycle with a stepless capacity control system is presented and influence of the key parameters of the system is evaluated. In the stepless capacity control system of a reciprocating compressor,mechanical unloaders are used to partially hold suction valves open for a certain time during the compression stroke. The typical working process of the reciprocating compressor is changed by capacity regulation apparatus. However,some critical parameters like the hydraulic force acting at the unloader have not been rigorously studied in previous researches. Here an improved numerical model of a double acting reciprocating compressor under the control stepless capacity is proposed and verified by experimental trials. Numerical simulations are carried out to select and evaluate the acting force which definitely has an influence on indicator diagrams of compressors. It is observed that the optimized range of 350 N to 380 N is preferable for the unloader force such that the intensity of opening and closing impacts are minimized. 展开更多
关键词 reciprocating compressor STEPLESS capacity CONTROL NUMERICAL MODEL parametersoptimization
下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
5
作者 TANG Wen-wu1,2,WANG Han-qing1,2(1.School of Energy Science and Engineering,Central South University,Changsha,Hunan 410083,China 2.School of Civil Engineering,Hunan University of Technology,Zhuzhou,Hunan 412008,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-conditioning refrigerating MACHINE condense HEAT ENTROPY evaluation LS-SVM
下载PDF
Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort 被引量:3
6
作者 刘红 马小磊 高亚峰 《Journal of Central South University》 SCIE EI CAS 2009年第S1期6-11,共6页
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three... To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes. 展开更多
关键词 air-conditioning TEMPERATURE thermal COMFORT air-conditIONER energy consumption NEUTRAL TEMPERATURE acceptable TEMPERATURE
下载PDF
Genetic Optimization Algorithm of PID Decoupling Control for VAV Air-Conditioning System 被引量:3
7
作者 王江江 安大伟 +1 位作者 张春发 荆有印 《Transactions of Tianjin University》 EI CAS 2009年第4期308-314,共7页
Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multiv... Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multivariable decoupling PID controller is designed for VAV air-conditioning system. Diagonal matrix decoupling method is employed to eliminate the coupling between the loop of supply air temperature and that of thermal-space air temperature. The PID controller parameters are optimized by means of an improved genetic algorithm in floating point representations to obtain better performance. The population in the improved genetic algorithm mutates before crossover, which is helpful for the convergence. Additionally the micro mutation algorithm is proposed and applied to improve the convergence during the later evolution. To search the best parameters, the optimized parameters ranges should be amplified 10 times the initial ideal parameters. The simulation and experiment results show that the decoupling control system is effective and feasible. The method can overcome the strong coupling feature of the system and has shorter governing time and less over-shoot than non-optimization PID control. 展开更多
关键词 genetic algorithm decoupling control PID control variable air volume air-conditioning system
下载PDF
Experimental Analysis of the Performances of Unit Refrigeration Systems Based on Parallel Compressors with Consideration of the Volumetric and Isentropic Efficiency 被引量:8
8
作者 Daoming Shen Chao Gui +1 位作者 Jinhong Xia Songtao Xue 《Fluid Dynamics & Materials Processing》 EI 2020年第3期489-500,共12页
The performances of a refrigeration unit relying on compressors working in parallel have been investigated considering the influence of the compressor volumetric efficiency and isentropic efficiency on the compression... The performances of a refrigeration unit relying on compressors working in parallel have been investigated considering the influence of the compressor volumetric efficiency and isentropic efficiency on the compression ratio.Moreover,the following influential factors have been taken into account:evaporation temperature,condensation temperature and compressor suction-exhaust pressure ratio for different opening conditions of the compressor.The following quantities have been selected as the unit performance measurement indicators:refrigeration capacity,energy efficiency ratio(COP),compressor power consumption,and refrigerant flow rate.The experimental results indicate that the system refrigeration capacity and COP decrease with a decrease in evaporation temperature,increase of condensation temperature,and increase in pressure ratio.The refrigerant flow rate increases with the increase in evaporation temperature,decrease in condensing temperature and increase in pressure ratio.The compressor power consumption increases with the increase in condensing temperature and increase in pressure ratio,but is not significantly affected by the evaporation temperature. 展开更多
关键词 Parallel compressor unit evaporation temperature condensation temperature pressure ratio refrigeration capacity energy efficiency ratio(COP)
下载PDF
Selection of Weather Parameters for Air-Conditioning System Design for Buildings with Long Thermal Lag 被引量:1
9
作者 GE Lian-feng1,2,LEI Ming3,CHEN You-ming1,2(1.College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China 2.Key Laboratory of Building Safety and Energy Efficiency,MOE,China (3.Aviation Theory Department,Aviation University of Air Force,Changchun,Jilin 130022,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期79-82,共4页
Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling lo... Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant. 展开更多
关键词 building construction THERMAL LAG system capacity design WEATHER data air-conditioning
下载PDF
Effects of process parameters on semi-solid squeeze casting performance of aluminum alloy scrolls for scroll compressors 被引量:3
10
作者 Yong-fei Wang Sheng-dun Zhao +1 位作者 Yi Guo Jun-ling Yang 《China Foundry》 SCIE 2020年第5期347-356,共10页
The aluminum alloy scroll is one of the key parts of the scroll compressors widely used in the air-conditioning,refrigeration,and heat pump systems.In this work,the semi-solid squeeze casting(SSSC)process was used to ... The aluminum alloy scroll is one of the key parts of the scroll compressors widely used in the air-conditioning,refrigeration,and heat pump systems.In this work,the semi-solid squeeze casting(SSSC)process was used to fabricate the aluminum alloy scroll.The effects of process parameters including the pouring temperature,mold temperature,and squeezing velocity on the filling and solidification behaviors of the alloys were investigated through simulations based on the power law cut-off(PLCO)material model.Results show that there is a significant increase in the flow velocity of the slurry,and the area of the high-speed region enlarges with the increase of the pouring temperature.The homogeneity of the temperature and velocity fields in the slurry is improved with an increase in mold temperature.Both the filling time and its variation rate decrease with an increase in squeezing velocity.The maximum solidification time exhibits a linear variation with the increase in pouring temperature.The shrinkage area is decreased by increasing the mold temperature.The optimal process parameters of the SSSC process were obtained from simulation analysis,which are the pouring temperature of 595°C,mold temperature of 350°C,and squeezing velocity of 0.3 m·s-1.Moreover,the qualified scroll casting was fabricated using the SSSC process under the optimal process parameters. 展开更多
关键词 semi-solid squeeze casting aluminum alloy scroll compressor numerical simulation experimental verification
下载PDF
Computer-Aided Solution to the Vibrational Effect of Instabilities in Gas Turbine Compressors 被引量:1
11
作者 Ezenwa Alfred Ogbonnaya Hyginus Ubabuike Ugwu Charles Agbeju Nimibofa Johnson 《Engineering(科研)》 2010年第8期658-664,共7页
Surge and stall are the two main types of instabilities that often occur on the compressor system of gas turbines. The effect of this instability often leads to excessive vibration due to the back pressure imposed to ... Surge and stall are the two main types of instabilities that often occur on the compressor system of gas turbines. The effect of this instability often leads to excessive vibration due to the back pressure imposed to the system by this phenomenon. In this work, fouling was observed as the major cause of the compressor instability. A step to analyze how this phenomenon can be controlled with the continuous examination of the vibration amplitude using a computer approach led to the execution of this work. The forces resulting to vibration in the system is usually external to it. This external force is aerodynamic and the effect was modeled using force damped vibration analysis. A gas turbine plant on industrial duty for electricity generation was used to actualize this research. The data for amplitude of vibration varied between -15 and 15 mm/s while the given mass flow rate and pressure ratio were determined as falling between 6.1 to 6.8 kg/s and 9.3 to 9.6 respectively. A computer program named VICOMS written in C++ programming language was developed. The results show that the machine should not be run beyond 14.0 mm vibration amplitude in order to avoid surge, stall and other flow-induced catastrophic breakdown. 展开更多
关键词 COMPUTERIZED Solution INSTABILITIES VIBRATION Gas TURBINE compressors OPERATIONAL Limits
下载PDF
Study of Failure Diagnostic Methods and Intelligent Diagnostic System for Reciprocating Compressors 被引量:5
12
作者 LIU Wei hua, ANG Hai song Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P.R.China 《International Journal of Plant Engineering and Management》 2002年第3期126-132,共7页
Three categories of failure diagnostic methods for reciprocating compressors are classified according to the signals adopted by the diagnosis. They are parameter method, vibration method, and oil analysis method. In t... Three categories of failure diagnostic methods for reciprocating compressors are classified according to the signals adopted by the diagnosis. They are parameter method, vibration method, and oil analysis method. In this paper, the applicable range and operational difficulties of these methods are discussed on the basis of analysis and induction upon normal failure. It is proposed that a compressor's normal failure can be divided into thermodynamical property failure and mechanical function failure. As to the former, the parameter method that takes a cylinder pressure signal as the main diagnostic signal may be applied; and as to the latter, the vibration signal frequency spectrum can be used to diagnose. At the same time, the structure of an intelligent diagnostic system based on neural networks is introduced, and its schematic is given. 展开更多
关键词 failure diagnostic method intellingent diagnostic system reciprocating compressor
下载PDF
The Experiment and Simulation of Solid Desiccant Dehumidification for Air-Conditioning System in a Tropical Humid Climate 被引量:1
13
作者 Juntakan Taweekun Visit Akvanich 《Engineering(科研)》 2013年第1期146-153,共8页
The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different ... The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD). 展开更多
关键词 SOLID DESICCANT DEHUMIDIFICATION air-conditioning System TROPICAL Humid CLIMATE
下载PDF
An Energy-Saving Control Strategy on Central Air-Conditioning System 被引量:1
14
作者 Sheng Xing 1 , Yin Juan 2 , Shang Jingfu 3 , Yu Yang 4 , Wu Zhangxian 5 1. State Grid Information & Telecommunication Co., Ltd. 2. China Huadian Finance Corporation Limited 3. State Grid AC Engineering Construction Company 4. Northeast China Electric Power Dispatching & Communication Center 5. North China Electric Power University 《Electricity》 2011年第4期62-66,共5页
An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con... An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy. 展开更多
关键词 central air-conditioning predictive control energy saving time-delay system simulated annealing
下载PDF
Fault Diagnosis of Reciprocating Compressors Valve Based on Cyclostationary Method 被引量:1
15
作者 王雷 王奉涛 +1 位作者 赵俊龙 马孝江 《Journal of Donghua University(English Edition)》 EI CAS 2011年第4期349-352,共4页
The relationship between second-order cyclostationary method and time-frequency distribution is studied, and cyclic autocorrelation(CA) function is indicated to be one sort of special time-frequency distribution met... The relationship between second-order cyclostationary method and time-frequency distribution is studied, and cyclic autocorrelation(CA) function is indicated to be one sort of special time-frequency distribution method. Furthermore, a fault diagnosis method for reciprocating compressors based on empirical mode decomposition (EMD) and CA function is proposed, and then it is applied to the fault diagnosis of reciprocating compressor valve. Firstly, the vibration signal of reciprocating compressor valve is decomposed by using ENID method, and several intrinsic mode functions (IMFs) are obtained. Secondly, the IMFs are evaluated by some denoising criterions to remove the noise and interfering ones. Finally, the CA functions of the remained IMFs are calculated, which will be used to reconstruct the CA function of the original vibration signal. Engineering application indicates that this method can sufficiently inhibit the cross-interference items of CA function. Therefore, more explicit working conditions of reciprocating compressor components can be achieved. 展开更多
关键词 reciprocating compressor VALVE fault diagnosis cyclic autocorrelation (CA) function empirical mode decomposition (EMD)
下载PDF
Investigation on Surge in Centrifugal Compressors
16
作者 朱智富 马朝臣 陈山 《Journal of Beijing Institute of Technology》 EI CAS 2009年第4期422-427,共6页
A test bench for conducting compressor surge experiments is set up, and different system configurations formed by changing the length of compressor outlet pipeline are tested for surge. Dynamic pressure signals relati... A test bench for conducting compressor surge experiments is set up, and different system configurations formed by changing the length of compressor outlet pipeline are tested for surge. Dynamic pressure signals relating to surges are acquired at different locations of the configurations using unsteady measurement & data acquisition system. The sliding window method is adopted to set up quantitative criterion on the surge. Parameters included in the criterion, such as location of data collection, size and step of sliding window, a mathematical quantity surge-judging and its threshold, etc., are given. Flow chart of surge evaluation is shown, and surge frequency was evaluated based on system configurations. With all these, the problem of judging the existence of surge by human experiences in compressor performance experiments can be solved. Hence this new approach may help to achieve intelligent operations on automatic compressor performance testrig. 展开更多
关键词 centrifugal compressor surge detection turboeharger sliding window
下载PDF
Application of Fuzzy Comprehensive Evaluation to Air-conditioning Competitive Power Analysis
17
作者 LU Congda LIU Gaojin JIANG Shaofei LV Chaoqun (The MOE Key Laboratory of Mechanical Manufacture and Automation,Zhejiang University of Technology,Hangzhou 310032,China 《武汉理工大学学报》 CAS CSCD 北大核心 2006年第S2期463-467,共5页
As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD),cus- tomer requirements should be understood and the product competitive power be analyzed as exactly as possi... As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD),cus- tomer requirements should be understood and the product competitive power be analyzed as exactly as possible for new product de- signing.Lots of information in the process of this research is fuzzy and uncertain,but traditional QFD can not deal with it well. Fuzzy theory can solve the problem.So a fuzzy model for analyzing product competitive power is formulated in this paper to im- prove traditional QFD,after that it is applied to analyze air-conditioning competitive power.When air-conditioning competitive power is analyzed using this model,firstly the importance weight of the customer requirements o fair-conditioning is determined us- ing the Analytic Hierarchy Process (AHP) weighting process,then air-conditloning competitive power is evaluated using fuzzy comprehensive evaluation.It is proved that the model is feasible and has good applicability. 展开更多
关键词 air-conditioning COMPETITIVE power QFD AHP FUZZY COMPREHENSIVE evaluation
下载PDF
Application of Dual Throttling Air-Conditioning System to Explosion-Proof Frequency Converter
18
作者 张于峰 高岩 盛颖 《Transactions of Tianjin University》 EI CAS 2015年第2期95-103,共9页
An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study inv... An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study investigated the feasibility and benefits of explosion-proof dual throttling cooling and dehumidification air-conditioning system applied to the explosion-proof frequency converter. The physical model of dual throttling air-conditioning system was established and its performance parameter was described by mathematical method. The design calculation of the system has also been done. The experimental result showed that the system reached the steady state at the refrigeration mode after running 45 min, and the maximum internal temperature of the flame-proof cavity was 31.0 ℃. The system reached the steady state at the dehumidification mode after running 37 min. The maximum internal relative humidity and temperature of the flame-proof cavity were 33.4% and 36.3 ℃, respectively. Therefore, the proposed system had excellent ability of heat dissipation and avoided internal dewing. Compared with water cooling system, it was more energy-saving and economical. The airflow field of dual throttling air-conditioning system was also studied by CFD simulation. It was found that the result of CFD numerical simulation was highly consistent with the experimental data. 展开更多
关键词 EXPLOSION-PROOF CONVERTER DUAL throttling air-conditioning CFD energy SAVING heat DISSIPATION dewing
下载PDF
Simulation of Artificial Intelligence for Automotive Air-conditioning System
19
作者 袁晓梅 陈佑华 陈芝久 《Journal of Donghua University(English Edition)》 EI CAS 2002年第1期40-43,共4页
The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Differen... The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Different control methods of AACS are discussed through simulation based on this model. The result shows that the neural- fuzzy control is the best one compared with the on-off control and conventional fuzzy control method.It can make the compartment's temperature descend rapidly to the designed temperature and the fluctuation is small. 展开更多
关键词 NEURAL network AUTOMOTIVE air-conditioning system(AACS) Simulation Modeling.
下载PDF
Energy performance assessment on central air-conditioning system of commercial building: A case study in China
20
作者 周璇 练斯甄 +1 位作者 闫军威 康英姿 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第8期3168-3179,共12页
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen... Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system. 展开更多
关键词 energy performance assessment thermal comfort indoor air quality central air-conditioning system energy saving
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部