期刊文献+
共找到13,896篇文章
< 1 2 250 >
每页显示 20 50 100
Performance analysis of heat pump based on a new solar air-source heat pump heating system 被引量:2
1
作者 梁彩华 张小松 +1 位作者 朱霞 李秀伟 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期227-231,共5页
To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and p... To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season. 展开更多
关键词 solar energy air-source heat pump heating mode PERFORMANCE SIMULATION
下载PDF
Developing Operational Model for Heat Pumps as Space Heating and Domestic Hot Water Provider
2
作者 Rilwan Olaolu Oliyide Jose B. Hernandez 《Open Journal of Applied Sciences》 2024年第10期2880-2900,共21页
In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is o... In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking. 展开更多
关键词 heat pumps Greenhouse Gases Space heating Domestic Hot Water TRANSFORMER MATLAB
下载PDF
Clogging caused by coupled grain migration and compaction effect during groundwater recharge for unconsolidated sandstone reservoir in groundwater-source heat pump
3
作者 Fujian Yang Jing Luo +3 位作者 Guiling Wang Hejuan Liu Dawei Hu Hui Zhou 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第8期2947-2959,共13页
In unconsolidated sandstone reservoirs,presence of numerous movable grains and a complex grain size composition necessitates a clear understanding of the physical clogging process for effective groundwater recharge in... In unconsolidated sandstone reservoirs,presence of numerous movable grains and a complex grain size composition necessitates a clear understanding of the physical clogging process for effective groundwater recharge in groundwater-source heat pump systems.To investigate this,a series of seepage experiments was conducted under in situ stress conditions using unconsolidated sandstone samples with varying grain compositions.The clogging phenomenon arises from the combined effects of grain migration and compaction,wherein the migration of both original and secondary crushed fine-grain particles blocks the seepage channels.Notably,grain composition influences the migration and transport properties of the grains.For samples composed of smaller grains,the apparent permeability demonstrates a transition from stability to decrease.In contrast,samples with larger grains experience a skip at the stability stage and directly enter the decrease stage,with a minor exception of a slight increase observed.Furthermore,a unique failure mode characterized by diameter shrinkage in the upper part of the sample is observed due to the combined effects of grain migration and in situ stress-induced compaction.These testing results contribute to a better understanding of the clogging mechanism caused by the coupled effects of grain migration and compaction during groundwater recharge in unconsolidated sandstone reservoirs used in groundwater-source heat pump systems. 展开更多
关键词 Groundwater-source heat pump CLOGGING Grain migration Compaction effect Groundwater recharge Unconsolidated sandstone
下载PDF
Performance analysis of deep borehole heat exchangers for decarbonization of heating systems
4
作者 Andreas E.D.Lund 《Deep Underground Science and Engineering》 2024年第3期349-357,共9页
Meeting the climate change mitigation targets will require a substantial shift from fossil to clean fuels in the heating sector.Heat pumps with deep borehole exchangers are a promising solution to reduce emissions.Her... Meeting the climate change mitigation targets will require a substantial shift from fossil to clean fuels in the heating sector.Heat pumps with deep borehole exchangers are a promising solution to reduce emissions.Here the thermal behavior of deep borehole exchangers(DBHEs)ranging from 1 to 2 km was analyzed for various heat flow profiles.A strong correlation between thermal energy extraction and power output from DBHEs was found,also influenced by the heating profile employed.Longer operating time over the year typically resulted in higher energy production,while shorter one yielded higher average thermal power output,highlighting the importance of the choice of heating strategy and system design for optimal performance of DBHEs.Short breaks in operation for regenerating the borehole,for example,with waste heat,proved to be favorable for the performance yielding an overall heat output close to the same as with continuous extraction of heat.The results demonstrate the usefulness of deep boreholes for dense urban areas with less available space.As the heat production from a single DBHE in Finnish conditions ranges from half up to even a few GWh a year,the technology is best suitable for larger heat loads. 展开更多
关键词 clean energy deep borehole exchangers energy transition geothermal heat ground-coupled heat pump
下载PDF
Novel Radiation-Adjustable Heating Terminal Based on Flat Heat Pipe Combined with Air Source Heat Pump
5
作者 Yifan Wu Hongli Sun +3 位作者 Mengfan Duan Borong Lin Hengxin Zhao Chaohung Liu 《Engineering》 SCIE EI CAS CSCD 2023年第1期192-207,共16页
The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking c... The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. However, as a major component of space heating, heating terminals might not fit well with ASHP in order to achieve both intermittency and comfort. Therefore, this study proposes a novel radiation-adjustable heating terminal combined with an ASHP to achieve electrification, intermittency, and better thermal comfort. Radiant terminals currently suffer from three major problems: limited maximum heating capacity, inability to freely adapt, and difficulty with combining them with ASHPs. These problems were solved by improving the structural design of the novel terminal (Improvement A–E). Results showed that the maximum heating capacity increased by 23.6% and radiation heat transfer ratio from 10.1% to 30.9% was provided for users with the novel terminal. Further, new flat heat pipe (FHP) design improved stability (compressor oil return), intermittency (refrigerant thermal inertia), and safety (refrigerant leakage risk) by reducing the length of exposed refrigerant pipes. Furthermore, a new phased operation strategy was proposed for the novel terminal, and the adjustability of the terminal was improved. The results can be used as reference information for decarbonizing buildings by electrifying heating terminals. 展开更多
关键词 Novel heating terminal air-source heat pump Structural impr ovement design Maximum heating capacity Rapid adjustability Room temperature distribution
下载PDF
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
6
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
7
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Analysis of Power Quality Problems in Large-Scale Application of Air-Source Heat Pump
8
作者 Zhihao Zheng Yanbo Che +2 位作者 Hailian Bi Dan Wu Wei He 《Energy Engineering》 EI 2022年第2期637-651,共15页
With the implementation of electric energy alternatives,the large-scale application of electric energy substitution represented by air-source heat pumps has replaced traditional coal-fired heating,which is beneficial ... With the implementation of electric energy alternatives,the large-scale application of electric energy substitution represented by air-source heat pumps has replaced traditional coal-fired heating,which is beneficial for the environment and alleviates air pollution.However,the large-scale application of airsource heat pumps has brought power quality problems such as voltage sags,harmonic pollution,and three-phase imbalance to the distribution network.This paper studies the fixed-frequency and variablefrequency air-source heat pump,introduces its working principle,analyzes the mechanism of its power quality problem.Moreover,the paper establishes a simulation model for the fixed-frequency heat pump and variable-frequency heat pump to connect to the distribution network.This research mainly studies the impact of large-scale fixed-frequency heat pumps on the depth of voltage sags in the distribution network and the impact of large-scale variable-frequency heat pumps on the harmonic content of the distribution network under different penetration rates and uses measured data to verify the reliability of the simulation results.This paper uses experimental data for the first time to verify the real power quality problems of large-scale heat pumps,which can provide a reference for determining the power quality standards for heat pumps connected to the power grid.At the same time,it can also provide a reference for the power quality management of the distribution network that is actually connected to electric heating. 展开更多
关键词 air-source heat pump voltage sag HARMONIC penetration rate
下载PDF
Thermal comfort assessment and energy consumption analysis of ground-source heat pump system combined with radiant heating/cooling 被引量:1
9
作者 路诗奎 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2012年第1期52-57,共6页
A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building... A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system. 展开更多
关键词 ground-source heat pump radiant heating/cooling thermal comfort energy consumption
下载PDF
Assessment of Low Global Warming Potential Refrigerants for Waste Heat Recovery in Data Center with On-Chip Two-Phase Cooling Loop
10
作者 Yuming Zhao Jing Wang +3 位作者 Bin Sun Zhenshang Wang Huashan Li Jiongcong Chen 《Frontiers in Heat and Mass Transfer》 EI 2024年第4期1171-1188,共18页
Data centers(DCs)are highly energy-intensive facilities,where about 30%–50%of the power consumed is attributable to the cooling of information technology equipment.This makes liquid cooling,especially in twophase mod... Data centers(DCs)are highly energy-intensive facilities,where about 30%–50%of the power consumed is attributable to the cooling of information technology equipment.This makes liquid cooling,especially in twophase mode,as an alternative to air cooling for the microprocessors in servers of interest.The need to meet the increased power density of server racks in high-performance DCs,along with the push towards lower global warming potential(GWP)refrigerants due to environmental concerns,has motivated research on the selection of two-phase heat transfer fluids for cooling servers while simultaneously recovering waste heat.With this regard,a heat pump-assisted absorption chiller(HPAAC)system for recovering waste heat in DCs with an on-chip twophase cooling loop driven by the compressor is proposed in the present paper and the low GWP hydrofluoroolefin refrigerants,including R1224yd(Z),R1233zd(E),R1234yf,R1234ze(E),R1234ze(Z),R1243zf and R1336mzz(Z),are evaluated and compared against R245fa as server coolant.For theHPAAC system,beginning with the development of energy and economic models,the performance is analyzed through both a parametric study and optimization using the coefficient of performance(COP),energy saving ratio(ESR),payback period(PBP)and net present value(NPV)as thermo-economic indicators.Using a standard vapor compression cooling system as a benchmark,the results indicate that with the evaporation temperature between 50℃and 70℃and the subcooling degree ranging from5℃to 15°C,R1233zd(E)with moderate compressor suction pressure and pressure ratio is the best refrigerant for the HPAAC systemwhile R1234yf performs the worst.More importantly,R1233zd(E)is also superior to R245fa based on thermo-economic performance,especially under work conditions with relatively lower evaporation temperature as well as subcooling degree.Under the given working conditions,the overall COP,ESR,NPV,and PBP of R1233zd(E)HPAAC with optimum subcooling degree range from4.99 to 11.27,25.53 to 64.59,1.13 to 4.10×10^(7) CNY and 5.77 to 2.22 years,respectively.Besides,the thermo-economic performance of R1233zd(E)HPAAC under optimum working conditions in terms of subcooling degree varying with the evaporation temperature is also investigated. 展开更多
关键词 heat pump absorption chiller waste heat recovery two-phase cooling loop
下载PDF
Investigation of energy-efficient heat pump assisted heterogeneous azeotropic distillation for separating of acetonitrile/ethyl acetate/n-hexane mixture 被引量:1
11
作者 Xinhao Li Qing Ye +4 位作者 Jinlong Li Lingqiang Yan Xue Jian Licheng Xie Jianyu Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第3期20-33,共14页
The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ... The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ternary mixture. The proposed scheme is optimized via the simulated annealing algorithm and minimum total annual cost(TAC) is used as objective functions. To minimize energy consumption,heat pump is added on the basis of optimal heterogeneous azeotropic distillation and heat integration technology is used to further improve the energy recovery. The TAC, gas emission, energy consumption and exergy destruction are used to discuss the economy and environmental protection of processes.Among all the processes, the heat pump with higher preheating temperature(HPT) assisted HAD process by combining with heat integration(HAD-HPT-HI) has best performances on economic, environment,energy and exergy. Compared with conventional HAD process, the HAD-HPT-HI achieves the reductions of 52.17%, 68.86%, 65.87% and 65.46% on TAC, total energy consumption, gas emissions and exergy destruction, respectively. 展开更多
关键词 Heterogeneous azeotropic distillation ENERGY-SAVING SA algorithm heat pump
下载PDF
Synthesis and Design of Distillation Columns for Wide-Boiling Binary Mixtures with Vapor Recompression Heat Pumps
12
作者 Shi Li 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2023年第4期127-138,共12页
The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column... The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column. However, the separation of wide-boiling binary mixtures leads to substantial temperature differences between the top and bottom of the column. This limits the applicability of conventional VRHP due to high capital costs and strict performance requirements of the compressor. To overcome these challenges and to accommodate compressor operating conditions, a novel synthesis and design method is introduced to integrate VRHPs with wide-boiling binary mixture distillation columns(WBMDCs). This method enables quick determination of an initial configuration for the integrated WBMDC-VRHP system and helps identify the optimum configuration with the minimum total annual cost. Two examples, namely the separation of benzene/toluene and isopropanol/chlorobenzene, are employed to derive optimum configurations of the WBMDC-VRHP and compare them with the WBMDC. A systematic comparison between the WBMDC-VRHP and WBMDC demonstrates the superior steady-state performance and economic efficiency of the WBMDC-VRHP. 展开更多
关键词 vapor recompression heat pump wide-boiling binary mixtures distillation column energy saving synthesis and design
下载PDF
Exergo-Environmental Study of a Recent Organic Solar Hybrid Heat Pump
13
作者 Rabeb Toujani Nahla Bouaziz 《Fluid Dynamics & Materials Processing》 EI 2023年第4期991-1001,共11页
A hybrid heat pump(compression/absorption)with an integrated thermal photovoltaic unit is studied.The considered working fluids are organic mixtures:R245fa/DMAC and R236fa/DMAC,chosen for their low Global Warming Pote... A hybrid heat pump(compression/absorption)with an integrated thermal photovoltaic unit is studied.The considered working fluids are organic mixtures:R245fa/DMAC and R236fa/DMAC,chosen for their low Global Warming Potential.The main objective is the optimization of energy efficiency in order to minimize the environmental impact through the implementation of a sustainable strategy.It is shown that Exergy Analysis itself is a valuable tool in energy integration.Within the imposed framework of minimizing total annual costs,entropy analysis can be instrumental in determining the optimal plant concept,optimizing energy conversion and use,and improving profitability.The present results are discussed under the optimistic hope that they may help to define new energy and environmental policies. 展开更多
关键词 Impact environmental exergy analysis CO_(2)emissions solar hybrid heat pump
下载PDF
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
14
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang Lingbao Wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Simulation Study of the Control Strategy of a DC Inverter Heat Pump Using a DC Distribution Network
15
作者 Siwei Han Xianglong Li +3 位作者 Wei Zhao Linyu Wang Anqi Liang Shuang Zeng 《Energy Engineering》 EI 2023年第6期1421-1444,共24页
Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public... Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public buildings,play a key role in adapting to PDEF systems.This research studied the basic principles and operational control strategies of a DC inverter heat pump using a DC distribution network with the aim of contributing to the development and application of small DC distribution systems.Along with the characteristics of a DC distribution network and different operating conditions,a DC inverter heat pump has the ability to adapt to changes in the DC bus voltage and adds flexibility to the system.Theoretical models of the DC inverter heat pump integrated with an ice storage unit were developed.The control strategies of the DC inverter heat pump system considered the influence of both room temperature and varied bus voltage.A simulation study was conducted using MATLAB&Simulink software with simulation results validated by experimental data.The results showed that:(1)The bus fluctuation under the rated working voltage had little effect on the operation of the unit;(2)When the bus voltage was fluctuating from 80%-90%or 105%-107%,the heat pump could still operate normally by reducing the frequency;(3)When the bus voltage was less than 80%or more than 107%,the unit needed to be shut down for the sake of equipment safety,so that the energy storage device could adjust to the sharp decrease or rise of voltage. 展开更多
关键词 Photovoltaics energy storage direct current and flexibility DC inverter heat pump MATLAB&Simulink control strategy
下载PDF
Impact of the Heat Pump on the Environment
16
作者 Jovan Mitrović 《Journal of Power and Energy Engineering》 2023年第6期26-33,共8页
The paper deals with the impact of a mechanical compression heat pump, operated by electrical energy, on the environment. Irrespective of its origin and the history of its production, this energy pollutes the environm... The paper deals with the impact of a mechanical compression heat pump, operated by electrical energy, on the environment. Irrespective of its origin and the history of its production, this energy pollutes the environment as waste heat. The operational energy, obtained from the so-called alternative energy sources (wind, water energy), also burdens the environment as waste heat. This is not the case with the solar energy. A direct conversion of the Sun’s rays into electricity does not additionally affect the environment, compared to their direct conversion into heat without our intervention. 展开更多
关键词 heat pump ENVIRONMENT
下载PDF
Exploring heating performance of gas engine heat pump with heat recovery 被引量:3
17
作者 董付江 刘凤国 +2 位作者 李先庭 尤学一 赵冬芳 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期1931-1936,共6页
In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1... In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature. 展开更多
关键词 gas engine heat pump coefficient of performance primary energy ratio heating mode heat recovery
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
18
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 air source heat pump system(ASHPS) space heating defrosting parameter COP
下载PDF
Performance analysis on solar-water compound source heat pump for radiant floor heating system
19
作者 曲世林 马飞 仇安兵 《Journal of Central South University》 SCIE EI CAS 2009年第S1期249-254,共6页
A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water t... A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system. 展开更多
关键词 heat pump SOLAR COMPOUND SOURCE COEFFICIENT of performance
下载PDF
Simulation of Air Source Heat Pump with Refrigerant Injection for Heating Operation
20
作者 Liu Haibo Shao Shuangquan +1 位作者 Ma Guoyuan Fan Boyuan 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第5期739-748,共10页
An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The... An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs. 展开更多
关键词 heat pump REFRIGERANT INJECTION air CONDITIONING SIMULATION electric vehicle(EV)
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部