We propose a fast,adaptive multiscale resolution spectral measurement method based on compressed sensing.The method can apply variable measurement resolution over the entire spectral range to reduce the measurement ti...We propose a fast,adaptive multiscale resolution spectral measurement method based on compressed sensing.The method can apply variable measurement resolution over the entire spectral range to reduce the measurement time by over 75%compared to a global high-resolution measurement.Mimicking the characteristics of the human retina system,the resolution distribution follows the principle of gradually decreasing.The system allows the spectral peaks of interest to be captured dynamically or to be specified a priori by a user.The system was tested by measuring single and dual spectral peaks,and the results of spectral peaks are consistent with those of global high-resolution measurements.展开更多
Recent progress in nuclear data measurement for ADS at Institute of Modern Physics is reviewed briefly.Based on the cooler storage ring of the Heavy Ion Research Facility in Lanzhou, nuclear data terminal was establis...Recent progress in nuclear data measurement for ADS at Institute of Modern Physics is reviewed briefly.Based on the cooler storage ring of the Heavy Ion Research Facility in Lanzhou, nuclear data terminal was established.The nuclear data measurement facility for the ADS spallation target has been constructed, which provides a very important platform for the experimental measurements of spallation reactions. A number of experiments have been conducted in the nuclear data terminal. A Neutron Time-of-Flight(NTOF)spectrometer was developed for the study of neutron production from spallation reactions related to the ADS project.The experiments of 400 MeV/u ^(16)O bombarded on a tungsten target were presented using a NTOF spectrometer.Neutron yields for 250 MeV protons incident on a thick grain-made tungsten target and a thick solid lead target have been measured using the water-bath neutron activation method. Spallation residual productions were studied by bombarding W and Pb targets with a 250 MeV proton beam using the neutron activation method. Benchmarking of evaluated nuclear data libraries was performed for D-T neutrons on ADS relevant materials by using the benchmark experimental facility at the China Institute of Atomic Energy.展开更多
This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in...This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in natural water are provided by natural and artificial radionuclides such as ^(40) K,^(137)Cs,and radionuclides belonging to ^(238)U and ^(232)Th series.The main a emitters related to gamma emissions in natural water are ^(224)Ra(240.98 keV)and ^(226)Ra(186.21 keV),and the β^(-) emitters are ^(40) K(1460.85 keV),^(214)Bi(609.31 keV),^(208)Tl(583.19 keV),and ^(214)Pb(351.93 keV).The formula for gross α and β^(-) activity concentration is based on these radionuclides,and the short half-life decay products are considered in the calculation.The detection efficiency of the device across energy region(0–3 MeV)is obtained through Monte Carlo simulation,and a calibration experiment is conducted to verify the simulation results.Gamma radioactivity is measured continuously for 114 d in Pixian County and Dongfeng Canal located in the Zouma River,Chengdu,Sichuan Province,China.A comparison of the calculation results and monitoring data from the Sichuan Management and Monitoring Center Station of Radioactive Environment indicates that the percentage and absolute error of a activity concentration is lower than 53%and 0.02 Bq/L,respectively,and that of β-activity concentration is lower than 33.2%and 0.016 Bq/L,respectively.The method can rapidly determine gross α and β^(-) activity concentrations in natural water online.展开更多
Landslides are one of the most disastrous geological hazards in southwestern China.Once a landslide becomes unstable,it threatens the lives and safety of local residents.However,empirical studies on landslides have pr...Landslides are one of the most disastrous geological hazards in southwestern China.Once a landslide becomes unstable,it threatens the lives and safety of local residents.However,empirical studies on landslides have predominantly focused on landslides that occur on land.To this end,we aim to investigate ashore and underwater landslide data synchronously.This study proposes an optimized mosaicking method for ashore and underwater landslide data.This method fuses an airborne laser point cloud with multi-beam depth sounder images.Owing to their relatively high efficiency and large coverage area,airborne laser measurement systems are suitable for emergency investigations of landslides.Based on the airborne laser point cloud,the traversal of the point with the lowest elevation value in the point set can be used to perform rapid extraction of the crude channel boundaries.Further meticulous extraction of the channel boundaries is then implemented using the probability mean value optimization method.In addition,synthesis of the integrated ashore and underwater landslide data angle is realized using the spatial guide line between the channel boundaries and the underwater multibeam sonar images.A landslide located on the right bank of the middle reaches of the Yalong River is selected as a case study to demonstrate that the proposed method has higher precision thantraditional methods.The experimental results show that the mosaicking method in this study can meet the basic needs of landslide modeling and provide a basis for qualitative and quantitative analysis and stability prediction of landslides.展开更多
GPS kinematic carrier phase measurements can be used to determine seven di- mension state and three attitude parameters of a motional carrier,such as an aircraft or a low- earth-orbit spacecraft,on which an antenna is...GPS kinematic carrier phase measurements can be used to determine seven di- mension state and three attitude parameters of a motional carrier,such as an aircraft or a low- earth-orbit spacecraft,on which an antenna is installed to receive GPS signals. It is known from airborne GPS test results for photogrammetry in China since 1994 that GPS carrier phase measurements in a motional environment have acquired external accuracies of ± 7. 9cm for two dimensional positions and ± 18. 1cm for point heights. This paper describes airborne GPS carrier phase -measurements with multireference stations and discusses how to evaluate the confidence of GPS kinematic data.展开更多
A BaF2 time differential perturbed angular distribution spectrometer has been established at the HI-13 tandem accelerator in CIAE. The time resolution of the spectrometer is 195 ps and the nonlinearity is less than 2 ...A BaF2 time differential perturbed angular distribution spectrometer has been established at the HI-13 tandem accelerator in CIAE. The time resolution of the spectrometer is 195 ps and the nonlinearity is less than 2 %. The spectrometer works very stably and no time drift is found over a period of experimelltal ruffs. This spectrometer has been successfully used in the g-factor measurement of 43 Sc (19/2-,3.1232 MeV).展开更多
Objective:More health workers die from infectious diseases such as tuberculosis(TB)than from any other infectious agent,so the current study is designed to assess TB treatment and preventive measures as they relate to...Objective:More health workers die from infectious diseases such as tuberculosis(TB)than from any other infectious agent,so the current study is designed to assess TB treatment and preventive measures as they relate to nursing care practice.Materials and Methods:A cross-sectional study was conducted among 82 nurses from December 2022 to January 2023.The data were collected through a self-developed questionnaire and analyzed by frequency table and analysis of variance(ANOVA)statistics.Results:The researchers found that nurses have sufficient knowledge on Infection Prevention and Control(IPC)policy,but not all nurses follow this management protocol,and the reason for their action is addressed in this study.The management and preventive measures used by the participants were identified as:proper cough etiquette/hygiene,working in a well-ventilated area,use of mask,appropriate disposal of used items and so on was reported.Moreover,this study also discovered that there is a positive correlation between nurses who had received training in IPC policy and their use of airborne preventive measures for TB patients(F=1.87,P=0.002)as well as a positive correlation between the availability of resources and their adherence to the proper use of airborne preventive measures when caring for TB patients(F=1.96,P˂0.001).Conclusion:We proposed infection and control training for nurses and adequate equipment supplies to the TB ward which are required in quick TB diagnosis,and must be carried out on a regular basis by health-care personnel,for efficient nursing practice.Ensuring proper safety equipment and isolation units should be available and assessable for nurses or other health workers showing sign or symptoms of TB.Similarly,it is necessary for government to put in place the control and regulations that will safeguard nurses and mandate them to adopt TB prevention protocols,which will aid in lowering the prevalence of TB among nurses.展开更多
The design of a lead slowing down spectrometer is being developed at KAERI (Korea Atomic Energy Research Institute) for an analysis of isotopic fissile content in spent and recycled fuel. The lead spectrometer has a...The design of a lead slowing down spectrometer is being developed at KAERI (Korea Atomic Energy Research Institute) for an analysis of isotopic fissile content in spent and recycled fuel. The lead spectrometer has an advantage to assay fissile content directly from spent fuel. Accurate fissile material data must be fed back to the spent fuel design and management. For reutilization of PWR spent fuel, an isotopic fissile content analysis is required to obtain safety and economics in the fuel cycle. The LSDS (lead slowing down spectrometer) uses the different fission signatures of each fissile with respect to the interrogation neutron energy. Several simulations were done and parameter was obtained for the system working. Energy between 1 keV to 0.1 eV is very sensitive to isotopic fissile material fission with good energy resolution. An external source neutron is necessary to induce enough fissile fission. A neutron production methodology is being developed for cost effectiveness, easy maintenance and high neutron yield rate. The threshold fission detector screens the prompt fast fission neutrons from an intense radiation background. The detection of a fission signature has a direct relationship with the isotopic fissile content.展开更多
A BaF2 time differential perturbed angular distribution spectrometer has been established at the HI-13 tandem accelerator in CIAE. The time resolution of the spectrometer is 195 ps and the nonlinearity is less than 2 ...A BaF2 time differential perturbed angular distribution spectrometer has been established at the HI-13 tandem accelerator in CIAE. The time resolution of the spectrometer is 195 ps and the nonlinearity is less than 2 %. The spectrometer works very stably and no time drift is found over a period of experimelltal ruffs. This spectrometer has been successfully used in the g-factor measurement of 43 Sc (19/2-,3.1232 MeV).展开更多
The Aircraft Integrated Meteorological Measuring System 20 Hz(AIMMS-20) has been used by the Hong Kong Observatory(HKO),China in data collection for tropical cyclone situations over the South China Sea and windshear a...The Aircraft Integrated Meteorological Measuring System 20 Hz(AIMMS-20) has been used by the Hong Kong Observatory(HKO),China in data collection for tropical cyclone situations over the South China Sea and windshear and turbulence measurement at the Hong Kong International Airport(HKIA).This paper discusses possible methods for further enhancing the quality of the wind and temperature measurements from the system.For wind measurement,the enhancement methods include:error modelling of the accelerometer(e.g.,bias offset and cross-axis rate sensitivity),global positioning system(GPS) phase lag consideration,better representation of the inertial measurement unit(IMU) velocity based on the GPS velocities and considering their location differences,consideration of the slower update of GPS velocity,and wing flexure.For temperature measurement,the methods include the consideration of the temperature sensor response and the sensor housing response.The results of typical flights using AIMMS-20 show that the accuracy of the wind and temperature data could be improved by 20%-30%.Though the discussion in the present paper is related mainly to a specific meteorological measuring system on a particular aircraft,the techniques so employed should be a useful reference for similar systems installed on other aircraft.展开更多
A new digital logarithmic airborne gamma ray spectrometer is designed in this study. The spectrometer adopts a high-speed and high-accuracy logarithmic amplifier (LOGll4) to amplify the pulse signal logarithmically ...A new digital logarithmic airborne gamma ray spectrometer is designed in this study. The spectrometer adopts a high-speed and high-accuracy logarithmic amplifier (LOGll4) to amplify the pulse signal logarithmically and to improve the utilization of the ADC dynamic range because the low-energy pulse signal has a larger gain than the high-energy pulse signal. After energy calibration, the spectrometer can clearly distinguish photopeaks at 239, 352, 583 and 609 keV in the low-energy spectral sections. The photopeak energy resolution of 137Cs improves to 6.75% from the original 7.8%. Furthermore, the energy resolution of three photopeaks, namely, K, U, and Th, is maintained, and the overall stability of the energy spectrum is increased through potassium peak spectrum stabilization. Thus, it is possible to effectively measure energy from 20 keV to 10 MeV.展开更多
The measurement of impurity distribution in the divertor region of tokamaks is key to studying edge impurity transport.Therefore,a space-resolved vacuum-ultraviolet(VUV)spectrometer is designed to measure impurity emi...The measurement of impurity distribution in the divertor region of tokamaks is key to studying edge impurity transport.Therefore,a space-resolved vacuum-ultraviolet(VUV)spectrometer is designed to measure impurity emission in the divertor region on EAST.For good spectral resolution,an eagle-type VUV spectrometer with 1 m long focal length with spherical holograph grating is used in the system.For light collection,a collimating mirror is installed between the EAST plasma and the VUV spectrometer to extend the observing range to cover the upper divertor region.Two types of detectors,i.e.a back-illuminated charge-coupled device detector and a photomultiplier-tube detector,are adopted for the spectral measurement and high-frequency intensity measurement for feedback control,respectively.The angle between the entrance and exit optical axis is fixed at 15°.The detector can be moved along the exit axis to maintain a good focusing position when the wavelength is scanned by rotating the grating.The profile of impurity emissions is projected through the space-resolved slit,which is set horizontally.The spectrometer is equipped with two gratings with 2400 grooves/mm and2160 grooves/mm,respectively.The overall aberration of the system is reduced by accurate detector positioning.As a result,the total spectral broadening can be reduced to about 0.013 nm.The simulated performance of the system is found to satisfy the requirement of measurement of impurity emissions from the divertor area of the EAST tokamak.展开更多
Iodine-131 is a highly toxic and volatile artificial radionuclide that is easily inhaled or ingested by the human body and selectively accumulates in thyroid tissue.With the development of nuclear medicine and nuclear...Iodine-131 is a highly toxic and volatile artificial radionuclide that is easily inhaled or ingested by the human body and selectively accumulates in thyroid tissue.With the development of nuclear medicine and nuclear power plants,the unintended release of ^(131)I has been widely studied,and the in vivo measurement of ^(131)I in the thyroid has become a research hotspot in the field of radiation protection.In recent decades,several methods and devices have been developed for in vivo measurements with respect to different measurement purposes and requirements.In this work,for more accurate determinations of individual ^(131)I in the thyroid in the field,the uncertainties of measurements by using portable gamma spectrometers were reviewed and analyzed,and monitoring strategies for improving the accuracy were proposed and prospected.展开更多
A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light s...A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light source is applied to measure the nonlinearity of the spectrometer at different wavelengths, respectively. An high-end CCD array spectrometer is tested. For colorful LED light sources, the nonlinearity factors of the CCD array spectrometer(absolute value) are as follows: k<0.8% for white light, k <1.1% for red light, k <2.2% for green light and k<4.7% for blue light. By using those quasi-monochromatic light sources, it is shown that the nonlinearity depends on the wavelength. It is important to be wariness about the spectral nonlinearity and related uncertainty evaluation when the narrow-band light source is tested.展开更多
Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. ...Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. With the integration time of 10 ms, flow phantom measurements, a liquid blood phantom test, and an arm cuff occlusion paradigm were performed to validate the feasibility of the system. We expect this proof-of-concept study would be widely adopted by other researchers for acquiring both blood flow and oxygenation changes due to its straightforward configuration and the possibility of multimodal measurement.展开更多
基金Project supported by the Natural Science Foundation of Shandong Province,China(Grant Nos.ZR2020MF119 and ZR2020MA082)the National Natural Science Foundation of China(Grant No.62002208)the National Key Research and Development Program of China(Grant No.2018YFB0504302).
文摘We propose a fast,adaptive multiscale resolution spectral measurement method based on compressed sensing.The method can apply variable measurement resolution over the entire spectral range to reduce the measurement time by over 75%compared to a global high-resolution measurement.Mimicking the characteristics of the human retina system,the resolution distribution follows the principle of gradually decreasing.The system allows the spectral peaks of interest to be captured dynamically or to be specified a priori by a user.The system was tested by measuring single and dual spectral peaks,and the results of spectral peaks are consistent with those of global high-resolution measurements.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences ADS Project(No.XDA03030200)the National Natural Science Foundation of China(No.91426301)
文摘Recent progress in nuclear data measurement for ADS at Institute of Modern Physics is reviewed briefly.Based on the cooler storage ring of the Heavy Ion Research Facility in Lanzhou, nuclear data terminal was established.The nuclear data measurement facility for the ADS spallation target has been constructed, which provides a very important platform for the experimental measurements of spallation reactions. A number of experiments have been conducted in the nuclear data terminal. A Neutron Time-of-Flight(NTOF)spectrometer was developed for the study of neutron production from spallation reactions related to the ADS project.The experiments of 400 MeV/u ^(16)O bombarded on a tungsten target were presented using a NTOF spectrometer.Neutron yields for 250 MeV protons incident on a thick grain-made tungsten target and a thick solid lead target have been measured using the water-bath neutron activation method. Spallation residual productions were studied by bombarding W and Pb targets with a 250 MeV proton beam using the neutron activation method. Benchmarking of evaluated nuclear data libraries was performed for D-T neutrons on ADS relevant materials by using the benchmark experimental facility at the China Institute of Atomic Energy.
基金the National Science Foundation of China(No.41774147)the National Key R&D Program of China(No.2017YFC0602105)+1 种基金the Science–Technology Support Plan Projects of Sichuan Province(No.2020YJ0334)the Sichuan Science and Technology Program(No.2020JDRC0108).
文摘This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in natural water are provided by natural and artificial radionuclides such as ^(40) K,^(137)Cs,and radionuclides belonging to ^(238)U and ^(232)Th series.The main a emitters related to gamma emissions in natural water are ^(224)Ra(240.98 keV)and ^(226)Ra(186.21 keV),and the β^(-) emitters are ^(40) K(1460.85 keV),^(214)Bi(609.31 keV),^(208)Tl(583.19 keV),and ^(214)Pb(351.93 keV).The formula for gross α and β^(-) activity concentration is based on these radionuclides,and the short half-life decay products are considered in the calculation.The detection efficiency of the device across energy region(0–3 MeV)is obtained through Monte Carlo simulation,and a calibration experiment is conducted to verify the simulation results.Gamma radioactivity is measured continuously for 114 d in Pixian County and Dongfeng Canal located in the Zouma River,Chengdu,Sichuan Province,China.A comparison of the calculation results and monitoring data from the Sichuan Management and Monitoring Center Station of Radioactive Environment indicates that the percentage and absolute error of a activity concentration is lower than 53%and 0.02 Bq/L,respectively,and that of β-activity concentration is lower than 33.2%and 0.016 Bq/L,respectively.The method can rapidly determine gross α and β^(-) activity concentrations in natural water online.
基金supported in part by the National Key R&D Program of China(Grant no.2016YFC0401908)。
文摘Landslides are one of the most disastrous geological hazards in southwestern China.Once a landslide becomes unstable,it threatens the lives and safety of local residents.However,empirical studies on landslides have predominantly focused on landslides that occur on land.To this end,we aim to investigate ashore and underwater landslide data synchronously.This study proposes an optimized mosaicking method for ashore and underwater landslide data.This method fuses an airborne laser point cloud with multi-beam depth sounder images.Owing to their relatively high efficiency and large coverage area,airborne laser measurement systems are suitable for emergency investigations of landslides.Based on the airborne laser point cloud,the traversal of the point with the lowest elevation value in the point set can be used to perform rapid extraction of the crude channel boundaries.Further meticulous extraction of the channel boundaries is then implemented using the probability mean value optimization method.In addition,synthesis of the integrated ashore and underwater landslide data angle is realized using the spatial guide line between the channel boundaries and the underwater multibeam sonar images.A landslide located on the right bank of the middle reaches of the Yalong River is selected as a case study to demonstrate that the proposed method has higher precision thantraditional methods.The experimental results show that the mosaicking method in this study can meet the basic needs of landslide modeling and provide a basis for qualitative and quantitative analysis and stability prediction of landslides.
文摘GPS kinematic carrier phase measurements can be used to determine seven di- mension state and three attitude parameters of a motional carrier,such as an aircraft or a low- earth-orbit spacecraft,on which an antenna is installed to receive GPS signals. It is known from airborne GPS test results for photogrammetry in China since 1994 that GPS carrier phase measurements in a motional environment have acquired external accuracies of ± 7. 9cm for two dimensional positions and ± 18. 1cm for point heights. This paper describes airborne GPS carrier phase -measurements with multireference stations and discusses how to evaluate the confidence of GPS kinematic data.
文摘A BaF2 time differential perturbed angular distribution spectrometer has been established at the HI-13 tandem accelerator in CIAE. The time resolution of the spectrometer is 195 ps and the nonlinearity is less than 2 %. The spectrometer works very stably and no time drift is found over a period of experimelltal ruffs. This spectrometer has been successfully used in the g-factor measurement of 43 Sc (19/2-,3.1232 MeV).
文摘Objective:More health workers die from infectious diseases such as tuberculosis(TB)than from any other infectious agent,so the current study is designed to assess TB treatment and preventive measures as they relate to nursing care practice.Materials and Methods:A cross-sectional study was conducted among 82 nurses from December 2022 to January 2023.The data were collected through a self-developed questionnaire and analyzed by frequency table and analysis of variance(ANOVA)statistics.Results:The researchers found that nurses have sufficient knowledge on Infection Prevention and Control(IPC)policy,but not all nurses follow this management protocol,and the reason for their action is addressed in this study.The management and preventive measures used by the participants were identified as:proper cough etiquette/hygiene,working in a well-ventilated area,use of mask,appropriate disposal of used items and so on was reported.Moreover,this study also discovered that there is a positive correlation between nurses who had received training in IPC policy and their use of airborne preventive measures for TB patients(F=1.87,P=0.002)as well as a positive correlation between the availability of resources and their adherence to the proper use of airborne preventive measures when caring for TB patients(F=1.96,P˂0.001).Conclusion:We proposed infection and control training for nurses and adequate equipment supplies to the TB ward which are required in quick TB diagnosis,and must be carried out on a regular basis by health-care personnel,for efficient nursing practice.Ensuring proper safety equipment and isolation units should be available and assessable for nurses or other health workers showing sign or symptoms of TB.Similarly,it is necessary for government to put in place the control and regulations that will safeguard nurses and mandate them to adopt TB prevention protocols,which will aid in lowering the prevalence of TB among nurses.
文摘The design of a lead slowing down spectrometer is being developed at KAERI (Korea Atomic Energy Research Institute) for an analysis of isotopic fissile content in spent and recycled fuel. The lead spectrometer has an advantage to assay fissile content directly from spent fuel. Accurate fissile material data must be fed back to the spent fuel design and management. For reutilization of PWR spent fuel, an isotopic fissile content analysis is required to obtain safety and economics in the fuel cycle. The LSDS (lead slowing down spectrometer) uses the different fission signatures of each fissile with respect to the interrogation neutron energy. Several simulations were done and parameter was obtained for the system working. Energy between 1 keV to 0.1 eV is very sensitive to isotopic fissile material fission with good energy resolution. An external source neutron is necessary to induce enough fissile fission. A neutron production methodology is being developed for cost effectiveness, easy maintenance and high neutron yield rate. The threshold fission detector screens the prompt fast fission neutrons from an intense radiation background. The detection of a fission signature has a direct relationship with the isotopic fissile content.
文摘A BaF2 time differential perturbed angular distribution spectrometer has been established at the HI-13 tandem accelerator in CIAE. The time resolution of the spectrometer is 195 ps and the nonlinearity is less than 2 %. The spectrometer works very stably and no time drift is found over a period of experimelltal ruffs. This spectrometer has been successfully used in the g-factor measurement of 43 Sc (19/2-,3.1232 MeV).
文摘The Aircraft Integrated Meteorological Measuring System 20 Hz(AIMMS-20) has been used by the Hong Kong Observatory(HKO),China in data collection for tropical cyclone situations over the South China Sea and windshear and turbulence measurement at the Hong Kong International Airport(HKIA).This paper discusses possible methods for further enhancing the quality of the wind and temperature measurements from the system.For wind measurement,the enhancement methods include:error modelling of the accelerometer(e.g.,bias offset and cross-axis rate sensitivity),global positioning system(GPS) phase lag consideration,better representation of the inertial measurement unit(IMU) velocity based on the GPS velocities and considering their location differences,consideration of the slower update of GPS velocity,and wing flexure.For temperature measurement,the methods include the consideration of the temperature sensor response and the sensor housing response.The results of typical flights using AIMMS-20 show that the accuracy of the wind and temperature data could be improved by 20%-30%.Though the discussion in the present paper is related mainly to a specific meteorological measuring system on a particular aircraft,the techniques so employed should be a useful reference for similar systems installed on other aircraft.
基金Supported by National Natural Science Foundation of China(40904054)National High Technology Research and Development Program 863(2012AA061803)
文摘A new digital logarithmic airborne gamma ray spectrometer is designed in this study. The spectrometer adopts a high-speed and high-accuracy logarithmic amplifier (LOGll4) to amplify the pulse signal logarithmically and to improve the utilization of the ADC dynamic range because the low-energy pulse signal has a larger gain than the high-energy pulse signal. After energy calibration, the spectrometer can clearly distinguish photopeaks at 239, 352, 583 and 609 keV in the low-energy spectral sections. The photopeak energy resolution of 137Cs improves to 6.75% from the original 7.8%. Furthermore, the energy resolution of three photopeaks, namely, K, U, and Th, is maintained, and the overall stability of the energy spectrum is increased through potassium peak spectrum stabilization. Thus, it is possible to effectively measure energy from 20 keV to 10 MeV.
基金the National Magnetic Confinement Fusion Science Program of China(Nos.2017YFE0301300,2019YFE03030002 and 2018YFE0303103)National Natural Science Foundation of China(No.12175278)+7 种基金Anhui Province Key Research and Development Program(No.202104a06020021)ASIPP Science and Research Grant(No.DSJJ-2020-02)Anhui Provincial Natural Science Foundation(No.1908085J01)Distinguished Young Scholar of Anhui Provincial Natural Science Foundation(No.2008085QA39)Instrument Developing Project of the Chinese Academy of Sciences(No.YJKYYQ20180013)the Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-73-01-001228)the University Synergy Innovation Program of Anhui Province(No.GXXT-2021-029)CAS President’s International Fellowship Initiative(No.2022VMB0007)。
文摘The measurement of impurity distribution in the divertor region of tokamaks is key to studying edge impurity transport.Therefore,a space-resolved vacuum-ultraviolet(VUV)spectrometer is designed to measure impurity emission in the divertor region on EAST.For good spectral resolution,an eagle-type VUV spectrometer with 1 m long focal length with spherical holograph grating is used in the system.For light collection,a collimating mirror is installed between the EAST plasma and the VUV spectrometer to extend the observing range to cover the upper divertor region.Two types of detectors,i.e.a back-illuminated charge-coupled device detector and a photomultiplier-tube detector,are adopted for the spectral measurement and high-frequency intensity measurement for feedback control,respectively.The angle between the entrance and exit optical axis is fixed at 15°.The detector can be moved along the exit axis to maintain a good focusing position when the wavelength is scanned by rotating the grating.The profile of impurity emissions is projected through the space-resolved slit,which is set horizontally.The spectrometer is equipped with two gratings with 2400 grooves/mm and2160 grooves/mm,respectively.The overall aberration of the system is reduced by accurate detector positioning.As a result,the total spectral broadening can be reduced to about 0.013 nm.The simulated performance of the system is found to satisfy the requirement of measurement of impurity emissions from the divertor area of the EAST tokamak.
基金partially supported by the National Natural Science Foundation of China(No.11775053).
文摘Iodine-131 is a highly toxic and volatile artificial radionuclide that is easily inhaled or ingested by the human body and selectively accumulates in thyroid tissue.With the development of nuclear medicine and nuclear power plants,the unintended release of ^(131)I has been widely studied,and the in vivo measurement of ^(131)I in the thyroid has become a research hotspot in the field of radiation protection.In recent decades,several methods and devices have been developed for in vivo measurements with respect to different measurement purposes and requirements.In this work,for more accurate determinations of individual ^(131)I in the thyroid in the field,the uncertainties of measurements by using portable gamma spectrometers were reviewed and analyzed,and monitoring strategies for improving the accuracy were proposed and prospected.
基金supported by the National Natural Science Foundation of China(No.61505191)
文摘A nonlinearity measurement of the charge-coupled device(CCD) array spectrometer using flux addition and comparison method is described. The light with various colors from the colorful light emitting diode(LED) light source is applied to measure the nonlinearity of the spectrometer at different wavelengths, respectively. An high-end CCD array spectrometer is tested. For colorful LED light sources, the nonlinearity factors of the CCD array spectrometer(absolute value) are as follows: k<0.8% for white light, k <1.1% for red light, k <2.2% for green light and k<4.7% for blue light. By using those quasi-monochromatic light sources, it is shown that the nonlinearity depends on the wavelength. It is important to be wariness about the spectral nonlinearity and related uncertainty evaluation when the narrow-band light source is tested.
基金partially supported by the SGER grant NRF-2015R1D1A1A02062382(J.G.Kim)Global Ph.D.Fellowship Program NRF-2015H1A2A1032268(M.Seong)through the National Research Foundation of Korea(NRF) funded by the Ministry of EducationGIST Research Institute in 2018
文摘Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. With the integration time of 10 ms, flow phantom measurements, a liquid blood phantom test, and an arm cuff occlusion paradigm were performed to validate the feasibility of the system. We expect this proof-of-concept study would be widely adopted by other researchers for acquiring both blood flow and oxygenation changes due to its straightforward configuration and the possibility of multimodal measurement.