Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors tha...Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors that collectively cause the alpha spectrum to exhibit a well-known low-energy tail.Therefore,the estabUshment of an alpha spectrum detector response function from the perspective of a signaling system must consider the various factors mentioned above.The detector response function is the convolution of an alphaparticle pulse function,two exponential functions,and a Gaussian function,followed by calculation of the parameters of the detector response function using the weighted leastsquares fitting method as proposed in this paper.In our experiment,^(239)Pu alpha spectra were measured by a highresolution,passivated implanted planar silicon(PIPS)detector at 10 levels of vacuum and 10 source-detector distances.The spectrum-fitting results were excellent as evaluated by reduced Chi-square(x^2) and correlation coefficients.Finally,the variation of parameters with vacuum level and source-detector distance was studied.Results demonstrate that σ,τ_1,and τ_2 exhibit no obvious trend of variation with vacuum in the range 2000-20,000 mTorr,and at a confidence level of 95%,the values of τ_1 and τ_2 decline in a similar fashion with source-detector distance by the power exponential function,while the value of a declines linearly.展开更多
The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi m...The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples.展开更多
The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the ...The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program.展开更多
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ...In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.展开更多
Au/Ni/n-type 4H-SiC Schottky alpha particle detectors are fabricated and annealed at temperatures between 400℃ and 700 ℃ to investigate the effects of thermal stability of the Schottky contact on the structural and ...Au/Ni/n-type 4H-SiC Schottky alpha particle detectors are fabricated and annealed at temperatures between 400℃ and 700 ℃ to investigate the effects of thermal stability of the Schottky contact on the structural and electrical properties of the detectors. At the annealing temperature of 500 ℃, the two nickel silicides (i.e., Ni31Sil2 and Ni2Si) are formed at the interface and result in the formation of an inhomogeneous Schottky barrier. By increasing the annealing temperature, the Ni31Sil2 transforms into the more stable Ni2Si. The structural evolution of the Schottky contact directly affects the electrical properties and alpha particle energy resolutions of the detectors. A better energy resolution of 2.60% is obtained for 5.48-MeV alpha particles with the detector after being annealed at 600 ℃. As a result, the Au/Ni/n-type 4H-SiC Schottky detector shows a good performance after thermal treatment at temperatures up to 700℃.展开更多
In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(T...In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(THGEM)has several advantages,including fast response time and good spatial resolution.Based on new THGEMs,a two-dimensional imaging detector was developed for alpha detection,with a position resolution greater than 3 mm.The detector design and test results are described in this paper.Fast radiation imaging SCMs,with a 40mm×40 mm sensitive area,are currently under development.展开更多
基金supported by the National Natural Science Foundation of China(Nos.41374130 and 41604154)Opening Foundation of Sichuan Provincial Key Lab of Applied Nuclear Techniques in Geosciences(No.gnzds2014003)the Open Fund of Robot Technology Used for Special Environment Key Laboratory of Sichuan Province(13zxtk04)
文摘Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors that collectively cause the alpha spectrum to exhibit a well-known low-energy tail.Therefore,the estabUshment of an alpha spectrum detector response function from the perspective of a signaling system must consider the various factors mentioned above.The detector response function is the convolution of an alphaparticle pulse function,two exponential functions,and a Gaussian function,followed by calculation of the parameters of the detector response function using the weighted leastsquares fitting method as proposed in this paper.In our experiment,^(239)Pu alpha spectra were measured by a highresolution,passivated implanted planar silicon(PIPS)detector at 10 levels of vacuum and 10 source-detector distances.The spectrum-fitting results were excellent as evaluated by reduced Chi-square(x^2) and correlation coefficients.Finally,the variation of parameters with vacuum level and source-detector distance was studied.Results demonstrate that σ,τ_1,and τ_2 exhibit no obvious trend of variation with vacuum in the range 2000-20,000 mTorr,and at a confidence level of 95%,the values of τ_1 and τ_2 decline in a similar fashion with source-detector distance by the power exponential function,while the value of a declines linearly.
文摘The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples.
文摘The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program.
文摘In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11675198,61574026,and 11405017)the National Key Research and Development Program of China(Grant Nos.2016YFB0400600 and 2016YFB0400601)+1 种基金the Natural Science Foundation of Liaoning Province of China(Grant Nos.201602453 and 201602176)the China Postdoctoral Science Foundation(Grant No.2016M591434)
文摘Au/Ni/n-type 4H-SiC Schottky alpha particle detectors are fabricated and annealed at temperatures between 400℃ and 700 ℃ to investigate the effects of thermal stability of the Schottky contact on the structural and electrical properties of the detectors. At the annealing temperature of 500 ℃, the two nickel silicides (i.e., Ni31Sil2 and Ni2Si) are formed at the interface and result in the formation of an inhomogeneous Schottky barrier. By increasing the annealing temperature, the Ni31Sil2 transforms into the more stable Ni2Si. The structural evolution of the Schottky contact directly affects the electrical properties and alpha particle energy resolutions of the detectors. A better energy resolution of 2.60% is obtained for 5.48-MeV alpha particles with the detector after being annealed at 600 ℃. As a result, the Au/Ni/n-type 4H-SiC Schottky detector shows a good performance after thermal treatment at temperatures up to 700℃.
基金supported by the China Institute of Atomic Energy and University of Chinese Academy of SciencesNational Natural Science Foundation of China(Nos.11575193 and U1732266)+2 种基金Key Research Program of Frontier Sciences,CAS(No.QYZDB-SSWSLH039)the Youth Innovation Promotion Association of CAS(No.2016153)the Natural Science Key Foundation of Guangxi(No.2015GXNSFDA139002)
文摘In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(THGEM)has several advantages,including fast response time and good spatial resolution.Based on new THGEMs,a two-dimensional imaging detector was developed for alpha detection,with a position resolution greater than 3 mm.The detector design and test results are described in this paper.Fast radiation imaging SCMs,with a 40mm×40 mm sensitive area,are currently under development.