The main problem existing in Guangdong electric power sources is analyzed in this paper. Based on theanalysis on energy-supply features, power demand and the technical and economic performances of various powersource...The main problem existing in Guangdong electric power sources is analyzed in this paper. Based on theanalysis on energy-supply features, power demand and the technical and economic performances of various powersources in Guangdong, the power sources construction scale and its structure are studied and analyzed in detail byusing Generation Expansion Software Package (GESP). The future development of Guangdong electric power sourcesunder the new situation of "Power from West to East" is studied as well.[展开更多
Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to redu...Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam;whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.展开更多
宣城发射台中波前端系统标准化改造主要包括信号源线路改造、增设供电数据监测以及不间断电源(Uninterruptible Power Supply,UPS)旁路改造。通过优化信号源线路布局,使其更加安全、美观且合理。基于增设的供电数据监测功能,实时掌握供...宣城发射台中波前端系统标准化改造主要包括信号源线路改造、增设供电数据监测以及不间断电源(Uninterruptible Power Supply,UPS)旁路改造。通过优化信号源线路布局,使其更加安全、美观且合理。基于增设的供电数据监测功能,实时掌握供配电与UPS运行状况,在出现异常时及时发出告警。通过UPS旁路改造,确保在UPS系统出现故障或对设备进行检修时能够自动切换到UPS旁路,便于信号源系统故障排查。展开更多
文摘The main problem existing in Guangdong electric power sources is analyzed in this paper. Based on theanalysis on energy-supply features, power demand and the technical and economic performances of various powersources in Guangdong, the power sources construction scale and its structure are studied and analyzed in detail byusing Generation Expansion Software Package (GESP). The future development of Guangdong electric power sourcesunder the new situation of "Power from West to East" is studied as well.[
文摘Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam;whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.
文摘宣城发射台中波前端系统标准化改造主要包括信号源线路改造、增设供电数据监测以及不间断电源(Uninterruptible Power Supply,UPS)旁路改造。通过优化信号源线路布局,使其更加安全、美观且合理。基于增设的供电数据监测功能,实时掌握供配电与UPS运行状况,在出现异常时及时发出告警。通过UPS旁路改造,确保在UPS系统出现故障或对设备进行检修时能够自动切换到UPS旁路,便于信号源系统故障排查。