The power supply and distribution systems for Antarctic research stations have special characteristics.In light of a worldwide trend toward a gradual increase in the application of renewable energy,an analysis was per...The power supply and distribution systems for Antarctic research stations have special characteristics.In light of a worldwide trend toward a gradual increase in the application of renewable energy,an analysis was performed to assess the feasibility of achieving a direct current power supply and distribution at Antarctic research stations by comparing the characteristics of direct current and alternating current electricity.Research was also performed on the status quo and future trends in direct current power supply and distribution systems in Antarctica research stations in combination with case studies.展开更多
Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a ...Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.展开更多
This paper partitions the arm current of MMC into uncontrollable current and controllable current. The former is determined by the load that can’t be controlled by taking any control strategy. The later caused by the...This paper partitions the arm current of MMC into uncontrollable current and controllable current. The former is determined by the load that can’t be controlled by taking any control strategy. The later caused by the unbalanced total inserted voltage of three arms can be controlled by some improved algorithms. The conclusion based on the researching the essence of circulating current is reached that change the number of the inserted sub-modules in each phase can suppress the circulating current. Combined with the improved ladder wave modulation, a novel circulating current suppression strategy particularly for the inverter station is developed. The improved strategy can adapt to load changes and reduce the circulating current and output voltage THD of MMC ac terminals greatly without increasing any peripheral circuits. Finally, the simulation model of 100 submodules in each phase is constructed in MATLAB and the simulation results verify the correctness and effectiveness of the modified control algorithm.展开更多
Due to the decrease in the number of switches for the four-switch three-phase alternating current-direct current(FSTP AC-DC)converter,it can easily lead to DC-link capacitor voltage imbalance and the system stability ...Due to the decrease in the number of switches for the four-switch three-phase alternating current-direct current(FSTP AC-DC)converter,it can easily lead to DC-link capacitor voltage imbalance and the system stability reduction.In order to solve these problems,a finite control set model predictive control(FCS-MPC)for FSTP AC-DC converters with DC-link capacitor voltage balancing is proposed.In this strategy,in order to facilitate calculation,theαβcoordinate system model is established and all voltage vectors are evaluated by establishing a cost function.During the whole process,phase locked loop(PLL)and complex modulation strategy are not required.In the new established cost function,the additional objective term of suppressing capacitor voltage fluctuation is to eliminate effectively the capacitor voltages oscillations and deviations and improve the system reliability.The simulation results show that the proposed strategy can keep the capacitor voltage balancing and has good dynamic and static performance.展开更多
This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The sche...This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.展开更多
基于模块化多电平换流器MMC(modular multilevel converter)的高压直流输电HVDC(high voltage direct current transmission)因具有无源网络支撑等优势而被广泛应用于大容量新能源外送消纳。受电力电子设备交互作用等因素影响,送端系统...基于模块化多电平换流器MMC(modular multilevel converter)的高压直流输电HVDC(high voltage direct current transmission)因具有无源网络支撑等优势而被广泛应用于大容量新能源外送消纳。受电力电子设备交互作用等因素影响,送端系统易发生振荡失稳现象。首先,建立了直驱风电场经MMC-HVDC并网送端系统的小扰动线性化模型,分析了风场有功输出对系统稳定性的影响。然后,建立了MMC及风机并网变流器交流侧dq阻抗模型,从阻抗角度揭示了送端系统振荡失稳机理。进一步,提出了基于MMC交流电压控制外环q轴附加阻尼的振荡抑制策略,可满足系统满功率范围内的运行稳定性要求。最后,基于全比例模型的仿真结果验证了所提振荡抑制策略的有效性。展开更多
随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,...随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。展开更多
文摘The power supply and distribution systems for Antarctic research stations have special characteristics.In light of a worldwide trend toward a gradual increase in the application of renewable energy,an analysis was performed to assess the feasibility of achieving a direct current power supply and distribution at Antarctic research stations by comparing the characteristics of direct current and alternating current electricity.Research was also performed on the status quo and future trends in direct current power supply and distribution systems in Antarctica research stations in combination with case studies.
基金supported by the State Key Laboratory of Advanced Power Transmission Technology(GEIRI-SKL-2020-011)。
文摘Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.
文摘This paper partitions the arm current of MMC into uncontrollable current and controllable current. The former is determined by the load that can’t be controlled by taking any control strategy. The later caused by the unbalanced total inserted voltage of three arms can be controlled by some improved algorithms. The conclusion based on the researching the essence of circulating current is reached that change the number of the inserted sub-modules in each phase can suppress the circulating current. Combined with the improved ladder wave modulation, a novel circulating current suppression strategy particularly for the inverter station is developed. The improved strategy can adapt to load changes and reduce the circulating current and output voltage THD of MMC ac terminals greatly without increasing any peripheral circuits. Finally, the simulation model of 100 submodules in each phase is constructed in MATLAB and the simulation results verify the correctness and effectiveness of the modified control algorithm.
基金National Natural Science Foundation of China(No.61741508)
文摘Due to the decrease in the number of switches for the four-switch three-phase alternating current-direct current(FSTP AC-DC)converter,it can easily lead to DC-link capacitor voltage imbalance and the system stability reduction.In order to solve these problems,a finite control set model predictive control(FCS-MPC)for FSTP AC-DC converters with DC-link capacitor voltage balancing is proposed.In this strategy,in order to facilitate calculation,theαβcoordinate system model is established and all voltage vectors are evaluated by establishing a cost function.During the whole process,phase locked loop(PLL)and complex modulation strategy are not required.In the new established cost function,the additional objective term of suppressing capacitor voltage fluctuation is to eliminate effectively the capacitor voltages oscillations and deviations and improve the system reliability.The simulation results show that the proposed strategy can keep the capacitor voltage balancing and has good dynamic and static performance.
文摘This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.
文摘基于模块化多电平换流器MMC(modular multilevel converter)的高压直流输电HVDC(high voltage direct current transmission)因具有无源网络支撑等优势而被广泛应用于大容量新能源外送消纳。受电力电子设备交互作用等因素影响,送端系统易发生振荡失稳现象。首先,建立了直驱风电场经MMC-HVDC并网送端系统的小扰动线性化模型,分析了风场有功输出对系统稳定性的影响。然后,建立了MMC及风机并网变流器交流侧dq阻抗模型,从阻抗角度揭示了送端系统振荡失稳机理。进一步,提出了基于MMC交流电压控制外环q轴附加阻尼的振荡抑制策略,可满足系统满功率范围内的运行稳定性要求。最后,基于全比例模型的仿真结果验证了所提振荡抑制策略的有效性。
文摘随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。