期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Simultaneous determination of metronidazole and tinidazole in plasma by using HPLC-DAD coupled with second-order calibration 被引量:4
1
作者 Li Qun Ouyang Hai Long Wu +4 位作者 Ya Juan Liu Jian Yue Wang Yong Jie Yu Hong Yan Zou Ru Qin Yu 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第10期1223-1226,共4页
A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD ... A method using HPLC-DAD coupled with second-order calibration was developed to simultaneously determine metronidazole and tinidazole in plasma samples in this paper. The second-order calibration method based on APTLD (alternating penalty trilinear decomposition) algorithm was proposed to analyze the three-way HPLC-DAD data from both standard and prediction samples, which makes it possible that calibration can be performed even in the presence of unknown interferences with a simple and green chromatographic condition and short analysis time. The results showed that good recoveries were obtained although the chromatographic and spectral profiles of the analytes of interest as well as background were partially overlapped with each other in plasma samples. 展开更多
关键词 HPLC-DAD Second-order calibration alternating penalty trilinear decomposition (APTLD) METRONIDAZOLE TINIDAZOLE PLASMA
下载PDF
Rapid Determination of Costunolide and Dehydrocostuslactone in Human Plasma Sample and Chinese Patent Medicine Xiang Sha Yang Wei Capsule Using HPLC-DAD Coupled with Second-order Calibration 被引量:2
2
作者 刘亚娟 吴海龙 +5 位作者 朱绍华 康超 许慧 苏志义 谷惠文 俞汝勤 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2012年第5期1137-1143,共7页
A novel methodology that combines high performance liquid chromatography with photodiode-array detector (HPLC-DAD) coupled with second-order calibration method based on alternating trilinear decomposition (ATLD) a... A novel methodology that combines high performance liquid chromatography with photodiode-array detector (HPLC-DAD) coupled with second-order calibration method based on alternating trilinear decomposition (ATLD) algorithm was used in determination of the effective constituents such as costunolide and dehydrocostuslactone, in plasma sample and Chinese patent medicine Xiang Sha Yang Wei (XSYW) capsule. Complicated systems such as plasma and Chinese patent medicine which have intricate components are tedious to isolate and purify. The problem that chromatographic peaks are heavily overlapped among the analytes and interferents from the background matrices can be resolved, and the satisfactory quantification results have been gained with the help of the ATLD algorithm which utilized "mathematical separation" instead of partial "physical or chemical separation". Meanwhile, HPLC-MS/MS method was used to validate the accuracy of the proposed determination method. 展开更多
关键词 COSTUNOLIDE dehydrocostuslactone HPLC-DAD second-order calibration alternating trilinear decomposition
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部