A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered...A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered story isolated system model is established using SAP2000. The dynamic nonlinear dynamic alternate method is used to analyze the structure against progressive collapse. Results show that the structure has good resistance to progressive collapse, and there is no progressive collapse under each working condition. The progressive collapse does not occur for the case of removing only one vertical structural member of the new staggered of isolated system. The side column has big influence on this isolated structures’ progressive collapse;the removal of vertical structural member of the isolation layer has less impact on the structure than the removal of the bottom vertical structural member. After the removing of the member, the internal force of the structure will be redistributed, and the axial force of the adjacent columns will change obviously, showing a trend of “near large and far small”.展开更多
Progressive collapse is a relatively rare event which happens due to unusual loading on a structure that lacks adequate continuity,ductility and indeterminacy which causes local collapse in that structure and then ext...Progressive collapse is a relatively rare event which happens due to unusual loading on a structure that lacks adequate continuity,ductility and indeterminacy which causes local collapse in that structure and then extends it to other structural parts.The US department of defense published UFC4-023-03 regulation regarding the building design against progressive collapse.This regulation,based on the ASCE 7-05 standard,introduces two general approaches to building design against progressive collapse,including direct design and indirect design approaches.In this study,a variety of structural design methods for progressive collapse have been investigated.Moreover,their strengths and weaknesses have been mentioned.In general,the results of this study show that design based on alternative path(AP)method is more economical than other methods.Moreover,application of AP method is much more commonly accepted by researchers and designers.展开更多
A 9-story concrete-filled steel tubular frame model is used to analyze the response of joints due to sudden column loss. Three different models are developed and compared to study the efficiency and feasibility of sim...A 9-story concrete-filled steel tubular frame model is used to analyze the response of joints due to sudden column loss. Three different models are developed and compared to study the efficiency and feasibility of simulation, which include substructure model, beam element model and solid element model. The comparison results show that the substructure model has a satisfying capability, calculation efficiency and accuracy to predict the concerned joints as well as the overall framework. Based on the substructure model and a kind of semi-rigid connection for concretefilled square hollow section steel column proposed in this paper, the nonlinear dynamic analyses are conducted by the alternate path method. It is found that the removal of the ground inner column brings high-level joint moments and comparatively low-level axial tension forces. The initial stiffness and transmitted ultimate moment of the semi-rigid connection are the main factors that influence the frame behavior, and their lower limit should be guaranteed to resist collapse. Reduced ultimate moment results in drastic displacement and axial force development, which may bring progressive collapse. The higher initial stiffness ensures that the structure has a stronger capacity to resist progressive collapse.展开更多
文摘A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered story isolated system model is established using SAP2000. The dynamic nonlinear dynamic alternate method is used to analyze the structure against progressive collapse. Results show that the structure has good resistance to progressive collapse, and there is no progressive collapse under each working condition. The progressive collapse does not occur for the case of removing only one vertical structural member of the new staggered of isolated system. The side column has big influence on this isolated structures’ progressive collapse;the removal of vertical structural member of the isolation layer has less impact on the structure than the removal of the bottom vertical structural member. After the removing of the member, the internal force of the structure will be redistributed, and the axial force of the adjacent columns will change obviously, showing a trend of “near large and far small”.
文摘Progressive collapse is a relatively rare event which happens due to unusual loading on a structure that lacks adequate continuity,ductility and indeterminacy which causes local collapse in that structure and then extends it to other structural parts.The US department of defense published UFC4-023-03 regulation regarding the building design against progressive collapse.This regulation,based on the ASCE 7-05 standard,introduces two general approaches to building design against progressive collapse,including direct design and indirect design approaches.In this study,a variety of structural design methods for progressive collapse have been investigated.Moreover,their strengths and weaknesses have been mentioned.In general,the results of this study show that design based on alternative path(AP)method is more economical than other methods.Moreover,application of AP method is much more commonly accepted by researchers and designers.
基金Supported by National Natural Science Foundation of China (No.50878066)Natural Science Foundation of Heilongjiang Province (No.ZJG0701)Heilongjiang Postdoctoral Science Foundation
文摘A 9-story concrete-filled steel tubular frame model is used to analyze the response of joints due to sudden column loss. Three different models are developed and compared to study the efficiency and feasibility of simulation, which include substructure model, beam element model and solid element model. The comparison results show that the substructure model has a satisfying capability, calculation efficiency and accuracy to predict the concerned joints as well as the overall framework. Based on the substructure model and a kind of semi-rigid connection for concretefilled square hollow section steel column proposed in this paper, the nonlinear dynamic analyses are conducted by the alternate path method. It is found that the removal of the ground inner column brings high-level joint moments and comparatively low-level axial tension forces. The initial stiffness and transmitted ultimate moment of the semi-rigid connection are the main factors that influence the frame behavior, and their lower limit should be guaranteed to resist collapse. Reduced ultimate moment results in drastic displacement and axial force development, which may bring progressive collapse. The higher initial stiffness ensures that the structure has a stronger capacity to resist progressive collapse.