A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be dir...A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be directly used in the system without modifying the original system or changing lubricant.By replacing R22 with TJR02,cooling rate gets faster and at least 20% of energy is saved.The actual detection in the standard test-bed verifies the experimental results and indicates that the adoption of TJR02 leads to greater efficiency and wider application.And the lower the refrigeratory temperature is,the more obvious the energy saving effects will be.展开更多
To solve the problems of single heat source heat pump systems in severe cold regions,a dual-source hybrid heat pump unit(DSHHPU)is proposed.The mathematical models of the DSHHPU when charging R134a or its alternative ...To solve the problems of single heat source heat pump systems in severe cold regions,a dual-source hybrid heat pump unit(DSHHPU)is proposed.The mathematical models of the DSHHPU when charging R134a or its alternative refrigerants R32,R290 and R600a were established respectively,and the performance was simulated and analysed.The results showed that the four refrigerants have different performance characteristics in different aspects.In heat pipe mode,the heating capacity and evaporating pressure of R32 are 36.94%and 59.94%higher than those of R134a.The heating capacity and evaporating pressure of R290 are 5.73%and 22.99%lower than those of R134a.The heating capacity and evaporating pressure of R600a are 43.29%and 68.08%lower than those of R134a.In vapour compression heating mode,the discharge temperature of R32,R290 and R600a are 184.88,72.98 and 66.44%of that of R134a.The coefficient of performance(COP)of R32,R290 and R600a are 72.65,111.59 and 117.94%of that of R134a.Finally,the effects of radiation intensity and ambient temperature on key performance parameters of the different refrigerants were analysed.The research results provide a reference for research on refrigerant replacements for multi-heat source composite heat pump systems.展开更多
In this paper,the entrainment ratio,pump work,heat loads of heat exchangers and COPthermal were theoretically evaluated for a solar-driven ejector-vapor compression hybrid refrigeration system with R1233zd(E)and R1336...In this paper,the entrainment ratio,pump work,heat loads of heat exchangers and COPthermal were theoretically evaluated for a solar-driven ejector-vapor compression hybrid refrigeration system with R1233zd(E)and R1336mzz(Z)as the working fluids.The evaluation of the utilization potentials of R1233zd(E)and R1336mzz(Z)was presented by comparing the system performance with that of R245fa,a commonly used refrigerant in the ejector system.The results indicated that the systems with R1233zd(E)and R1336mzz(Z)had a higher entrainment ratio and lower pump work.The pump works when using R1233zd(E)and R1336mzz(Z)can be up to 14.59%and 38.05%lower than those of R245fa,respectively.Meanwhile,the system showed the highest COPthermal utilizing R1233zd(E)followed by that of R245fa,with the R1336mzz(Z)system having the lowest value.The differences between R1233zd(E)and R1336mzz(Z)systems,R1233zd(E)and R245fa systems were 4.33%and 2.0%,respectively.This paper was expected to provide a good reference for the utilizing prospect of R1233zd(E)and R1336mzz(Z)in ejector refrigeration systems.展开更多
基金Supported by the Key Technology R&D Program of Tianjin,China(No.11ZCKFGX21100)Tianjin New Coastal District "Ten Campaign" Major Science and Technology Project(No.2010-BK140009 and 2010-BK140002)+1 种基金National Basic Research Program of China("973" Program,No.2009CB219900)the Program for Changjiang Scholars and Innovative Research Team in University(No.IRT0936)
文摘A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be directly used in the system without modifying the original system or changing lubricant.By replacing R22 with TJR02,cooling rate gets faster and at least 20% of energy is saved.The actual detection in the standard test-bed verifies the experimental results and indicates that the adoption of TJR02 leads to greater efficiency and wider application.And the lower the refrigeratory temperature is,the more obvious the energy saving effects will be.
基金The authors gratefully acknowledge the support from the Natural Science Foundation of China(grant No.51778115)the Fundamen-tal Research Funds for the Central Universities(grant No.N182502043).
文摘To solve the problems of single heat source heat pump systems in severe cold regions,a dual-source hybrid heat pump unit(DSHHPU)is proposed.The mathematical models of the DSHHPU when charging R134a or its alternative refrigerants R32,R290 and R600a were established respectively,and the performance was simulated and analysed.The results showed that the four refrigerants have different performance characteristics in different aspects.In heat pipe mode,the heating capacity and evaporating pressure of R32 are 36.94%and 59.94%higher than those of R134a.The heating capacity and evaporating pressure of R290 are 5.73%and 22.99%lower than those of R134a.The heating capacity and evaporating pressure of R600a are 43.29%and 68.08%lower than those of R134a.In vapour compression heating mode,the discharge temperature of R32,R290 and R600a are 184.88,72.98 and 66.44%of that of R134a.The coefficient of performance(COP)of R32,R290 and R600a are 72.65,111.59 and 117.94%of that of R134a.Finally,the effects of radiation intensity and ambient temperature on key performance parameters of the different refrigerants were analysed.The research results provide a reference for research on refrigerant replacements for multi-heat source composite heat pump systems.
基金This work was financially sponsored by National Natural Science Foundation of China(No.51906216)Zhejiang Provincial Natural Science Foundation of China(No.LQ18E060001)European Union project H2020-MSCA-RISE 778104.
文摘In this paper,the entrainment ratio,pump work,heat loads of heat exchangers and COPthermal were theoretically evaluated for a solar-driven ejector-vapor compression hybrid refrigeration system with R1233zd(E)and R1336mzz(Z)as the working fluids.The evaluation of the utilization potentials of R1233zd(E)and R1336mzz(Z)was presented by comparing the system performance with that of R245fa,a commonly used refrigerant in the ejector system.The results indicated that the systems with R1233zd(E)and R1336mzz(Z)had a higher entrainment ratio and lower pump work.The pump works when using R1233zd(E)and R1336mzz(Z)can be up to 14.59%and 38.05%lower than those of R245fa,respectively.Meanwhile,the system showed the highest COPthermal utilizing R1233zd(E)followed by that of R245fa,with the R1336mzz(Z)system having the lowest value.The differences between R1233zd(E)and R1336mzz(Z)systems,R1233zd(E)and R245fa systems were 4.33%and 2.0%,respectively.This paper was expected to provide a good reference for the utilizing prospect of R1233zd(E)and R1336mzz(Z)in ejector refrigeration systems.