The exfoliation corrosion susceptibility and electrochemical impedance spectrosc opy(EIS) of rolled and peak-aged 8090 Al-Li alloys in EXCO solution were studi ed,and the EIS after exfoliation was simulated. Once exfo...The exfoliation corrosion susceptibility and electrochemical impedance spectrosc opy(EIS) of rolled and peak-aged 8090 Al-Li alloys in EXCO solution were studi ed,and the EIS after exfoliation was simulated. Once exfoliation occurs,two ca pacitive arcs appear in the EIS at high-mediate frequency and mediate-low freq uency respectively. The exfoliation-attacked alloy surface consists of two part s,an original flat alloy surface and a new inter-face exposed to EXCO solution due to the exfoliation. The capacitance corresponding to the new exfoliation in ter-face increases approximately linearly with time at early exfoliation stage,due to the enlargement of the new inter-face. Then it maintains stable,due to the corrosion product covering on the new inter-face. The exfoliation suscepti bility can be judged through the average slope of the capacitance vs time curve of the early exfoliation stage. This average slope of the rolled 8090 alloy is m uch higher than that of the peak-aged 8090 alloy,accordingly the rolled 8090 a lloy is more susceptible to exfoliation than the peak-aged 8090 alloy.展开更多
The corrosion resistance of the micro-arc oxidation(MAO) ceramic coating on a cast Al-13Si-5Cu alloy was investigated using various electrochemical methods including electrochemical impedance spectroscopy(EIS) and pol...The corrosion resistance of the micro-arc oxidation(MAO) ceramic coating on a cast Al-13Si-5Cu alloy was investigated using various electrochemical methods including electrochemical impedance spectroscopy(EIS) and polarization curves.Microstructures of MAO ceramic coating were studied by SEM,and the influence of microscopic patterns on corrosion resistance was analyzed.The corrosion resistance of the aluminum alloy can be improved significantly by MAO process owing to increasing impedance and corrosion potential and decreasing corrosion current,and the ceramic coatings are composed of loose layer,compact layer and transition layer,which improve the corrosion resistance.The corrosin resistance is determined by the thickness of the compact layer and is not proportional to the total thickness of MAO,though the latter is one of the important factors influencing the corrosin resistance.展开更多
The through-thickness corrosion inhomogeneity of 7050-T7451 Al alloy thick plate was studied using immersion tests, potentiodynamic polarization, electrochemical impedance spectroscopy(EIS), slow strain rate testing(S...The through-thickness corrosion inhomogeneity of 7050-T7451 Al alloy thick plate was studied using immersion tests, potentiodynamic polarization, electrochemical impedance spectroscopy(EIS), slow strain rate testing(SSRT) technique combined with optical microscopy(OM), scanning electron microscopy(SEM) and transmission electron microscopy(TEM). The results show that the through-thickness corrosion resistance is ranked in the order of T/2>surface>T/4. And the 75 mm-thick 7050 alloy plate presents better corrosion resistance than the 35 mm-thick plate. The results are discussed in terms of the combined effect of recrystallization and cooling rate in quenching. Alloy with lower volume fraction of recrystallization and smaller grain aspect ratio displays better corrosion resistance. The lower corrosion resistance caused by the slower cooling rate results from the higher coverage rate of grain boundary precipitates and larger width of precipitate free zone.展开更多
文摘The exfoliation corrosion susceptibility and electrochemical impedance spectrosc opy(EIS) of rolled and peak-aged 8090 Al-Li alloys in EXCO solution were studi ed,and the EIS after exfoliation was simulated. Once exfoliation occurs,two ca pacitive arcs appear in the EIS at high-mediate frequency and mediate-low freq uency respectively. The exfoliation-attacked alloy surface consists of two part s,an original flat alloy surface and a new inter-face exposed to EXCO solution due to the exfoliation. The capacitance corresponding to the new exfoliation in ter-face increases approximately linearly with time at early exfoliation stage,due to the enlargement of the new inter-face. Then it maintains stable,due to the corrosion product covering on the new inter-face. The exfoliation suscepti bility can be judged through the average slope of the capacitance vs time curve of the early exfoliation stage. This average slope of the rolled 8090 alloy is m uch higher than that of the peak-aged 8090 alloy,accordingly the rolled 8090 a lloy is more susceptible to exfoliation than the peak-aged 8090 alloy.
基金Project(09JK481) supported by the Special Research Plan Project of the Education Department of Shaanxi Provincethe Open Fund Item of Thin-film Technology and Optical Detection Key Laboratory of Shaanxi Province,China
文摘The corrosion resistance of the micro-arc oxidation(MAO) ceramic coating on a cast Al-13Si-5Cu alloy was investigated using various electrochemical methods including electrochemical impedance spectroscopy(EIS) and polarization curves.Microstructures of MAO ceramic coating were studied by SEM,and the influence of microscopic patterns on corrosion resistance was analyzed.The corrosion resistance of the aluminum alloy can be improved significantly by MAO process owing to increasing impedance and corrosion potential and decreasing corrosion current,and the ceramic coatings are composed of loose layer,compact layer and transition layer,which improve the corrosion resistance.The corrosin resistance is determined by the thickness of the compact layer and is not proportional to the total thickness of MAO,though the latter is one of the important factors influencing the corrosin resistance.
基金Project(2012CB619503)supported by the National Basic Research Program of ChinaProject(2013AH100055)supported by the Foshan Civic Technological Innovation Foundation,China
文摘The through-thickness corrosion inhomogeneity of 7050-T7451 Al alloy thick plate was studied using immersion tests, potentiodynamic polarization, electrochemical impedance spectroscopy(EIS), slow strain rate testing(SSRT) technique combined with optical microscopy(OM), scanning electron microscopy(SEM) and transmission electron microscopy(TEM). The results show that the through-thickness corrosion resistance is ranked in the order of T/2>surface>T/4. And the 75 mm-thick 7050 alloy plate presents better corrosion resistance than the 35 mm-thick plate. The results are discussed in terms of the combined effect of recrystallization and cooling rate in quenching. Alloy with lower volume fraction of recrystallization and smaller grain aspect ratio displays better corrosion resistance. The lower corrosion resistance caused by the slower cooling rate results from the higher coverage rate of grain boundary precipitates and larger width of precipitate free zone.