A simple and rapid liquid chromatography-tandem mass spectrometry(LC-MS/MS)method was developed and validated for the quantitative determination of glycyrrhetic acid(GA),metabolite of glycyrrhizin and glycyrrhetat...A simple and rapid liquid chromatography-tandem mass spectrometry(LC-MS/MS)method was developed and validated for the quantitative determination of glycyrrhetic acid(GA),metabolite of glycyrrhizin and glycyrrhetate,in human plasma.GA and internal standard(IS,thiamphenicol)were separated on a C_(18)column by elution with acetonitrile-ammonium acetate solution(5 mmol/L)(70:30,v/v)after a simple liquid-liquid extraction with ethyl acetate.The flow rate was 0.8 mL/min. They were detected by tandem mass spectrometry in the negative ion multiple reaction monitoring(MRM)mode with ion transitions of m/z 469.3→355.3 for GA and m/z 354.1→185.0 for IS.The calibration curve was linear over GA concentration range of 0.5-500 ng/mL(r^20.99),with intra-and inter-day precisions(RSD)of less than 7.1%,and mean extraction recovery of 74.3%. The method was used for the pharmacokinetic study of ammonium glycyrrhetate after its oral administration of a single dose of 75 mg ammonium glycyrrhetate tablet in humans.The main pharmacokinetic parameters of GA were as follows:AUC_(0-t) (3457.26±1999.01)ng·h/mL;AUC_(0-∞)(3708.85±2428.36)ng·h/mL;MRT_(0-t)(19.69±4.03)h;MRT_(0-∞)(22.83±8.45)h;t_(1/2)Z (11.71±7.77)h;T_(max)(13.40±4.84)h;CLz/F(29.17±19.82)L/h;Vz/F(487.38±518.07)L;C_(max)(215.85±99.88)ng/mL.展开更多
文摘A simple and rapid liquid chromatography-tandem mass spectrometry(LC-MS/MS)method was developed and validated for the quantitative determination of glycyrrhetic acid(GA),metabolite of glycyrrhizin and glycyrrhetate,in human plasma.GA and internal standard(IS,thiamphenicol)were separated on a C_(18)column by elution with acetonitrile-ammonium acetate solution(5 mmol/L)(70:30,v/v)after a simple liquid-liquid extraction with ethyl acetate.The flow rate was 0.8 mL/min. They were detected by tandem mass spectrometry in the negative ion multiple reaction monitoring(MRM)mode with ion transitions of m/z 469.3→355.3 for GA and m/z 354.1→185.0 for IS.The calibration curve was linear over GA concentration range of 0.5-500 ng/mL(r^20.99),with intra-and inter-day precisions(RSD)of less than 7.1%,and mean extraction recovery of 74.3%. The method was used for the pharmacokinetic study of ammonium glycyrrhetate after its oral administration of a single dose of 75 mg ammonium glycyrrhetate tablet in humans.The main pharmacokinetic parameters of GA were as follows:AUC_(0-t) (3457.26±1999.01)ng·h/mL;AUC_(0-∞)(3708.85±2428.36)ng·h/mL;MRT_(0-t)(19.69±4.03)h;MRT_(0-∞)(22.83±8.45)h;t_(1/2)Z (11.71±7.77)h;T_(max)(13.40±4.84)h;CLz/F(29.17±19.82)L/h;Vz/F(487.38±518.07)L;C_(max)(215.85±99.88)ng/mL.