Evaluation of the systematic set-up errors using electronic portal image device in the radiotherapy procedures
1
作者 Ehab M. Attalla Rizk Abd El Moneam +2 位作者 Aida R. Tolba Maha H.Mokhtar Medhat W. Ismail 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第9期439-442,共4页
Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using ... Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using electronic portal. Methods: This study was carried out on 12 patients, treated for pelvis tumor; and total of 240 images obtained by electronic portal image device (EPID) were analyzed. The EPIs acquire using EPID attached to the Siemens linear accelerator. The anatomy match- ing software (Theraview) was used and displacement in two dimensions were noted for each treatment field to study patient setup errors. Results: The percentages of mean deviations less than 5 mm in X direction were 65% & 92%, from 5-10 mm were 31% & 19% and more than 10 mm were 11% & 9% forNP and lateral direction respectively. The percentages of mean deviations less than 5 mm in Y direction were 65% & 63%, from 5-10 mm were 33% & 28% and more than 10 mm were 22% & 29%. The mean deviations in 2D-vector errors were 〈 5 mm in 47% and 46%, 5-10 mm in 36% and 37% and 〉 10 mm in 37% and 37% of images in the NP and lateral direction respectively. Conclusion: The results revealed that the ranges of set up errors are immobilization method to improve reproducibility. The observed variations were not within the limits.. 展开更多
关键词 electronic portal imaging device (EPID) setup errors tumor control probability
下载PDF
基于电子射野影像系统的光栅位置和剂量验证研究
2
作者 眭建锋 孙佳伟 +3 位作者 谢凯 髙留刚 林涛 倪昕晔 《中国医疗器械杂志》 2024年第2期150-155,共6页
目的 使用基于电子射野影像系统(electronic portal imaging device,EPID)的质控系统,在Primus和VenusX加速器上实现光栅位置及剂量验证。方法 通过灰度值最大梯度方法计算光栅位置,评估偏差。使用剂量标定和剂量计算相结合的算法对EPI... 目的 使用基于电子射野影像系统(electronic portal imaging device,EPID)的质控系统,在Primus和VenusX加速器上实现光栅位置及剂量验证。方法 通过灰度值最大梯度方法计算光栅位置,评估偏差。使用剂量标定和剂量计算相结合的算法对EPID采集的图像进行剂量重建,将EPID和MapCheck/PTW得到的数据,分别与计划系统剂量进行γ通过率分析。结果 VenusX加速器光栅误差小于1 mm,Primus重新标定后误差明显减小。重建的剂量,在3%/3 mm,阈值10%和2%/2 mm,阈值10%的2种标准下,Primus加速器γ平均通过率分别为98.86%和91.39%;VenusX加速器γ平均通过率分别为98.49%和91.11%。结论 基于EPID的质控系统,可提高加速器质控效率,减轻物理师工作负担。 展开更多
关键词 电子射野影像系统 质控 光栅 剂量验证
下载PDF
EPID在加速器光射野一致性检测中的应用
3
作者 梅国建 尹楚欧 +3 位作者 邓娟 何迎盈 叶程伟 刘江 《中国医疗设备》 2024年第10期58-61,78,共5页
目的比较慢感光胶片和电子射野影像装置(Electronic Portal Imaging Device,EPID)在检测加速器光射野一致性中的差异,以探索出一种准确、高效、经济的加速器光射野一致性检测方法。方法在每周的加速器质控过程中,分别使用慢感光胶片和E... 目的比较慢感光胶片和电子射野影像装置(Electronic Portal Imaging Device,EPID)在检测加速器光射野一致性中的差异,以探索出一种准确、高效、经济的加速器光射野一致性检测方法。方法在每周的加速器质控过程中,分别使用慢感光胶片和EPID来检测Synergy医用电子直线加速器的6 MV X射线在射野为10 cm×10 cm时的光射野一致性;连续检测20周后,统计分析2种工具在检测加速器光射野一致性中的差异。结果Synergy加速器的6MV X射线在射野为10 cm×10cm时,采用慢感光胶片和EPID在X1、X2、Y1和Y2共4个方向上检测光射野一致性的结果均符合NCC/T-RT001-2019《医用电子直线加速器质量控制指南》所规定的性能要求。其中,在X1方向上,慢感光胶片和EPID2种工具检测的光射野一致性差异分别为(0.29±0.40)、(0.16±0.41)mm;在X2方向上,慢感光胶片和EPID2种工具检测的光射野一致性差异分别为(-0.04±0.30)、(-0.14±0.38)mm;在Y1方向上,慢感光胶片和EPID2种工具检测的光射野一致性差异分别为(0.13±0.32)、(0.26±0.35)mm;在Y2方向上,慢感光胶片和EPID2种工具检测的光射野一致性差异分别为(-0.20±0.33)、(-0.18±0.34)mm。在X1、X2、Y1和Y2共4个方向上,慢感光胶片和EPID之间检测的光射野一致性差异均无统计学差异(P>0.05)。结论与慢感光胶片相比,EPID在加速器的光射野一致性检测中具有较好的一致性,且具有准确、高效、经济的特点,可用于加速器光射野一致性的检测。 展开更多
关键词 加速器 电子射野影像装置 光野一致性 慢感光胶片 质量控制
下载PDF
基于EPID的长靶区计划验证测量方法研究
4
作者 曾海滨 郭建 《生物医学工程与临床》 CAS 2024年第3期317-323,共7页
目的探讨电子射野影像装置(EPID)板移动之后的数据结果是否存在误差;若存在误差,则进一步探索产生误差的方法,并且探究提出的长靶区计划验证测量方法是否可行。方法选择2021年9月至2022年11月在苏州大学附属第四医院放疗科接受放射治疗... 目的探讨电子射野影像装置(EPID)板移动之后的数据结果是否存在误差;若存在误差,则进一步探索产生误差的方法,并且探究提出的长靶区计划验证测量方法是否可行。方法选择2021年9月至2022年11月在苏州大学附属第四医院放疗科接受放射治疗(简称放疗)的患者20例,其中男性7例,女性13例;年龄39~79岁,平均年龄57岁;直肠癌11例,宫颈癌9例;冠状位靶区长度17.96~31.86 cm,冠状位靶区平均长度为22.6 cm;靶区体积898.8~2139.2 cm^(3),平均靶区体积1299.5 cm^(3);11例采用容积旋转调强放疗计划,9例采用调强放疗计划;均使用6 MV射线,600 MU/min剂量率;均采用各向异性分析算法和射野剂量(PD)影像预测算法分别计算体剂量和预测图像。设计并开展移动EPID板位置的开放野试验与归零、不归零准直器角度的准直器试验,同步应用MatriXX对计划进行验证,以作为标准验证归零准直器角度对计划通过率的影响,对数据及计划Gamma通过率进行分析。结果研究结果表明,EPID板移位后数据存在较大误差,其修正过程与预测的Profile并不完全一致,但是在曲线趋势上具有一定程度的相似性,并且在关键数据曲线交点上具有高度一致性。针对准直器归零与不归零,执行PD计划验证时二者Gamma通过率具有强相关性(Corr=0.994,P<0.05),差异无统计学意义(t=-1.63,P=0.119)。同时,Bland-Altman一致性分析结果表明无论准直器是否归零,PD计划验证与MatriXX计划验证的计划通过率均具有良好的一致性。结论长靶区计划应用EPID执行计划验证测量时应确保EPID板处于校准零位,若执行计划验证时EPID板移动,得到的结果存在较大误差。在确定执行该计划验证并不会辐照损坏EPID的电路板时,可固定EPID板位置;存在辐照损坏EPID的电路板风险时,可归零准直器角度以执行PD计划验证,所得到的计划通过率可以近似替代不归零准直器角度得到的计划通过率结果。 展开更多
关键词 电子射野影像系统 计划验证 长靶区 准直器角度
下载PDF
Machine Performance Check束流均匀性改变对Portal Dosimetry计划剂量验证的影响 被引量:1
5
作者 姚凯宁 王若曦 +5 位作者 吴昊 弓健 刘卓伦 张健 冯仲苏 杜乙 《中国医学物理学杂志》 CSCD 2022年第4期397-403,共7页
目的:探究Machine Performance Check(MPC)系统束流均匀性变化对Portal Dosimetry(PD)计划验证的影响,为临床MPC均匀性的阈值设定和电子影像系统(EPID)的校准频率提供参考。方法:选取本中心EDGE加速器上首次治疗患者26例和10 cm×10... 目的:探究Machine Performance Check(MPC)系统束流均匀性变化对Portal Dosimetry(PD)计划验证的影响,为临床MPC均匀性的阈值设定和电子影像系统(EPID)的校准频率提供参考。方法:选取本中心EDGE加速器上首次治疗患者26例和10 cm×10 cm方野1例,制定治疗计划和验证计划。在MPC束流均匀性偏差增大的情况下,分别在EPID校准前和校准后执行验证计划,并在计划系统PD模块中分析,统计对比图像剂量和γ通过率。本研究还列出EDGE加速器一年间MPC束流均匀性的结果。结果:MPC 1年的统计结果显示束流均匀性偏差的升高趋势明显并且速度加快,表明EPID存在设备老化现象。EPID校准前后验证计划的图像剂量和γ通过率的对比结果表明不同能量方野计划在影像板中心附近的剂量差异为1%~2%,临床射野计划由于复杂性提高,剂量差异最大可以达到10%。EPID校准后的γ通过率高于校准前。结论:EPID探测器的一致性改变对PD计划剂量验证有一定影响,提示临床MPC均匀性阈值为2%时能够对PD计划剂量验证起到预警作用,EPID应在MPC重新采集基线之前校准,以保证验证计划的质量,保证患者放疗的安全性。 展开更多
关键词 计划剂量验证 束流均匀性 Machine Performance Check 电子射野影像系统 portal Dosimetry
下载PDF
Varian 23EX加速器固定剂量率旋转调强技术的Portal Dosimetry验证 被引量:3
6
作者 王杰 邵凯南 +4 位作者 陈鹏 曾嵘 姜琦 郑士明 闵旭红 《中国医学物理学杂志》 CSCD 2019年第10期1134-1138,共5页
目的:应用Varian公司的Portal Dosimetry系统和ScandiDos公司的Delta4三维半导体阵列对Varian 23EX加速器固定剂量率旋转调强(CDR-VMAT)计划进行验证并对比分析。方法:随机选取10例头颈部肿瘤患者、10例胸部肿瘤患者和10例腹部肿瘤患者... 目的:应用Varian公司的Portal Dosimetry系统和ScandiDos公司的Delta4三维半导体阵列对Varian 23EX加速器固定剂量率旋转调强(CDR-VMAT)计划进行验证并对比分析。方法:随机选取10例头颈部肿瘤患者、10例胸部肿瘤患者和10例腹部肿瘤患者,采用Ray Station计划系统在Varian 23EX加速器上设计CDR-VMAT。照射野根据肿瘤部位合理设计,射线能量为6MVX线,每个弧的剂量率和机架转速恒定并由计划系统优化给出。据此分别生成适用23EX自带EPID的Portal Dosimetry验证计划和适用Delta4的验证计划,按照3mmDTA、3%Dose标准分析其Gamma通过率,并进行配对t检验。结果:10例头颈部肿瘤CDR-VMAT计划Portal Dosimetry验证和Delta4验证的Gamma通过率分别为(97.9±1.1)%和(99.9±0.2)%,P<0.05。10例胸部肿瘤CDR-VMAT计划的Gamma通过率分别为(99.5±0.7)%和(99.7±0.4)%,P=0.09。10例腹部肿瘤CDR-VMAT计划的Gamma通过率分别为(99.5±0.3)%和(99.7±0.4)%,P=0.19。结论:CDR-VMAT技术作为Varian23EX加速器一种可选的放射治疗技术能够有效提高机器的计划执行效率,配合Varian Portal Dosimetry系统可以方便地对23EX加速器上的CDR-VMAT计划进行验证。通过与Delta4进行比较,对胸部和腹部肿瘤计划,其Gamma通过率均大于95%且无显著差异,对于头颈部肿瘤计划Gamma通过率有差异,但均满足大于95%的要求。 展开更多
关键词 加速器 固定剂量率 旋转调强 电子射野影像系统 剂量验证
下载PDF
CT模拟定位机在调强放疗位置验证中的应用 被引量:1
7
作者 齐洪志 杨玉刚 +2 位作者 郝洁 许林 尚革 《中国医疗设备》 2023年第9期53-58,共6页
目的 探讨CT模拟定位机在调强放疗位置验证中的应用。方法 选取新疆医科大学第一附属医院准备实施调强放射治疗患者60例,使用CT模拟定位机对其放疗位置进行验证,并将患者随机分配至瓦里安和医科达加速器,分别使用电子射野影像系统(Elect... 目的 探讨CT模拟定位机在调强放疗位置验证中的应用。方法 选取新疆医科大学第一附属医院准备实施调强放射治疗患者60例,使用CT模拟定位机对其放疗位置进行验证,并将患者随机分配至瓦里安和医科达加速器,分别使用电子射野影像系统(Electronic Portal Imaging Device,EPID)和锥形束CT(Cone Beam Computed Tomography,CBCT)重新进行位置验证,分析位置验证结果。结果 使用CT模拟定位机位置验证在左右(Lateral,Lat)、前后(Vertical,Vrt)和头脚(Longitudinal,Lng)3个方向的位置偏差分别为(1.5333±0.6456)、(1.2600±0.5063)、(1.0333±0.3676)mm。在Lat方向和Vrt方向上,EPID和CBCT位置验证结果与CT模拟机位置验证比较,差异均无统计学意义(P>0.05)。在Lng方向,CT模拟定位机平均位移显著小于EPID和CBCT(P<0.05)。结论 使用CT模拟定位机可以获取软组织分辨率更好的位置验证影像,方便医生观察靶区和危及器官的相对关系,可以很好地完成放疗前位置验证。 展开更多
关键词 电子射野影像系统 锥形束CT CT模拟定位机 位置验证
下载PDF
The Journey of SRS: An Initial Experience of Starting Sterotactic Radiosurgery Facility at Purbanchal Cancer Hospital—First in Nepal
8
作者 Birendra Kumar Yadav Karthik Nagamuthu +11 位作者 Alok Thakur Kushal Rizal Umesh Kumar Sharma Ujwal Rai Dinesh Thapa Shishir Thapa Kumar Chinnappan Amit Kumar Dubey Suraj Gurung Aman Yadav Utpalkant Kumar Ranjay Kumar 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2023年第2期37-50,共14页
Introduction: Radiotherapy (RT) is a vital cancer treatment modality for both curative and palliative purposes. Nepal is a developing country with a population of around 30 million people. Cancer affects 100 - 120 peo... Introduction: Radiotherapy (RT) is a vital cancer treatment modality for both curative and palliative purposes. Nepal is a developing country with a population of around 30 million people. Cancer affects 100 - 120 people out of every 100,000, and the figure is increasing. The number of radiation facility machines in the country is still countable in fingers. Purbanchal Cancer Hospital, Nepal is the first comprehensive cancer facility capable of performing stereotactic radiosurgery (SRS). Our facility has cutting-edge Varian Truebeam Linear Accelerators with millennium MLC, which makes SRS and SRT’S for intracranial lesions such as small benign and malignant tumors much easier. In addition to SRS, we are the pioneers of SBRT for lung using 4DCT, interstitial & intraluminal brachytherapy, RPM Gated & DIBH modalities in Nepal. Methods & Materials: The purpose of this study is to share our experience in establishing an SRS facility in the country, which includes training the RT team on the importance of process accuracy, patient selection, patient assessment, mould preparation, and describing image data acquisition, target, and organ at risk delineation on CT and MRI images, treatment planning process, and quality assurance. Results & Discussion: The plans for all SRS and SRT cases are based on target coverage, OAR sparing, hotspot inside the target, conformity index, heterogeneity index, and dose fall off. To select the final plan, we used strict passing criteria such as a conformity index Paddick (CIPaddick) more than 0.85, a falloff between 100% and 50% of less than 5.5 mm (maximum 6 mm in irregular targets), and a hotspot inside the target between 115 to 140 percent, as per clinical standards. In addition, we determined the CILomax and CIRTOG for each case. Passing criteria for verification plans are set as minimum of 95% for a 2% percentage dose difference (% DD) and a 2-mm distance to an agreement (DTA). We also gathered demographic data from patients treated in the first year, such as diagnosis, lesion size, dose fraction, heterogeneity index (HI), conformity index (CI) and gamma index. SRS/SRT treatment was successfully implemented, and over 40 patients were treated with positive clinical outcomes. Conclusion: SRS now has a wider range of alternatives, thanks to technology advancements in recent years. SRS’s dosimetric advantages have steadily been extended to extracranial locations. Purbanchal Cancer Hospital, Birtamode, Nepal established a comprehensive cancer facility with qualified workforce with the goal of providing high-quality treatment to the people of Nepal. 展开更多
关键词 Conformity Index Double Shell Positioning System electronic portal imaging device Linear Accelerator Millennium MLC Octavius Detector 1500 Setup Field
下载PDF
基于电子射野影像装置的肺部肿瘤立体定向体部放射治疗在体三维剂量验证模体研究及临床应用
9
作者 王鹏飞 刘晓 +6 位作者 毛荣虎 李兵 郭伟 王保胜 葛红 雷宏昌 王祥 《郑州大学学报(医学版)》 CAS 北大核心 2023年第6期841-847,共7页
目的:探讨基于电子射野影像装置的肺部肿瘤立体定向体部放射治疗在体三维剂量验证模体研究及临床应用。方法:通过电子射野影像装置在体三维剂量验证系统,在静态和动态模体上测试不同立体定向体部放射治疗照射技术计划(静态调强、滑窗调... 目的:探讨基于电子射野影像装置的肺部肿瘤立体定向体部放射治疗在体三维剂量验证模体研究及临床应用。方法:通过电子射野影像装置在体三维剂量验证系统,在静态和动态模体上测试不同立体定向体部放射治疗照射技术计划(静态调强、滑窗调强、旋转调强及适形、动态适形旋转治疗),比较在体三维剂量分布5种剂量/距离一致性标准(5%/2 mm、3%/3 mm、3%/2 mm、3%/1 mm、2%/2 mm)的γ通过率,检测计划照射精度,并对临床肺立体定向体部放射治疗病例进行在体三维剂量验证靶区和危及器官剂量体积分析。结果:模体研究结果显示,在静态模体中静态调强、滑窗调强、旋转调强照射方式γ通过率差异无统计学意义(P均>0.05),在动态模体中静态调强计划γ通过率偏低,其他照射方式计划之间相近。临床应用结果显示,临床病例在体三维剂量验证3%/3 mm标准明显低于治疗前剂量验证结果,剂量体积直方图分析中体积变化大的危及器官存在较大剂量偏差。结论:基于电子射野影像装置的肺部肿瘤立体定向体部放射治疗在体三维剂量验证,能为肺部肿瘤立体定向体部放射治疗治疗期间剂量投照的准确性提供有效安全性检查,可应用于临床,为自适应治疗提供基础。 展开更多
关键词 肺部肿瘤 电子射野影像装置 立体定向体部放射治疗 在体三维剂量验证 γ通过率
下载PDF
非晶硅平板电子射野影像用于放射治疗剂量学质量控制检验的应用 被引量:12
10
作者 陈明伟 邓小武 +2 位作者 黄劭敏 陈利 康德华 《癌症》 SCIE CAS CSCD 北大核心 2007年第11期1272-1275,共4页
背景与目的:非晶硅平板型电子射野影像系统(amorphous silicon electronic portal imaging device,a-SiEPID)具有良好的剂量学品质,作为一种快速的二维剂量测量系统,在常规质量控制、调强照射野验证及实时患者剂量监测等方面具有广阔的... 背景与目的:非晶硅平板型电子射野影像系统(amorphous silicon electronic portal imaging device,a-SiEPID)具有良好的剂量学品质,作为一种快速的二维剂量测量系统,在常规质量控制、调强照射野验证及实时患者剂量监测等方面具有广阔的应用前景。为将非晶硅平板电子射野影像用于放射治疗的剂量学检验,本研究针对其射野影像建立了修正模型,并应用于加速器照射野的常规质量保证工作。方法:对a-SiEPID常用的图像刻度模式进行剂量刻度改进以用于照射剂量测量:通过一种由若干个小野组合形成"泛野"的方式来克服传统的泛野获取方式的缺陷,从而较准确地修正a-Si EPID各像素单元之间的灵敏度差异;并建立离轴剂量的响应曲线和修正数学模型。以修正后的a-SiEPID射野影像测量照射野的剂量分布并与三维水箱中电离室扫描的结果进行比较验证。结果:经所建立的模型进行剂量刻度和修正后,高剂量区,a-Si EPID与电离室测量结果偏差<2%,在半影区,a-Si EPID测量的剂量分布曲线比电离室测量结果略为陡峭。结论:非晶硅平板型电子射野影像(a-Si EPID)系统具有良好的物理剂量学品质,可以用作照射野常规质控检验和调强放射治疗射野剂量能量分布的快速工具。 展开更多
关键词 非晶硅平板 EPID 射野剂量 质量控制
下载PDF
应用CBCT、EPID研究鼻咽癌2种体位固定方式摆位误差的比较分析 被引量:54
11
作者 陆维 许婷婷 +2 位作者 许青 应红梅 胡超苏 《中国癌症杂志》 CAS CSCD 北大核心 2014年第7期535-539,共5页
背景与目的:随着放疗技术和设备的不断发展,鼻咽癌放射治疗已经进入了精确放疗时代,摆位误差成为影响放疗效果的非常重要的因素。本研究在千伏级锥形束CT(cone beam computed tomography,CBCT)与兆伏级电子射野影像系统(electronic port... 背景与目的:随着放疗技术和设备的不断发展,鼻咽癌放射治疗已经进入了精确放疗时代,摆位误差成为影响放疗效果的非常重要的因素。本研究在千伏级锥形束CT(cone beam computed tomography,CBCT)与兆伏级电子射野影像系统(electronic portal imaging device,EPID)2种影像模式引导下治疗鼻咽癌,在头枕+头颈肩面膜、真空气垫+头颈肩面膜固定2种方式下的摆位误差分析比较。方法:随机选取40例鼻咽癌患者分成2组(头枕+头颈肩面膜组,真空气垫+头颈肩面膜固定组),每组组内再分成CBCT扫描组和EPID验证组。将CBCT扫描图像与计划CT图像进行自动骨性配准、将EPID拍摄的正侧位片采用突出性骨性标志进行手动配准,分别得出x、y、z共3个线性方向上的摆位误差值,对获得的2组数据进行组内组间两两比较,采用t检验比较数据差异有无统计学意义。结果:头枕+头颈肩面膜组摆位后行CBCT扫描,在x、y、z方向上进行配准所得的平均误差分别为:x方向(0.67±2.01)mm、y方向(0.51±1.71)mm、z方向(0.57±2.04)mm;拍摄EPID验证片配准所得误差均值:x方向(0.69±2.19)mm、y方向(0.54±2.03)mm、z方向(0.61±2.11)mm。真空气垫+头颈肩面膜固定组摆位后行CBCT扫描,在x、y、z方向上进行配准所得的平均误差分别为:x方向(0.42±1.81)mm、y方向(0.33±1.55)mm、z方向(0.50±1.75)mm;拍摄EPID验证片配准误差均值:x方向(0.44±1.87)mm、y方向(0.43±1.70)mm、z方向(0.54±1.77)mm。采用头枕+头颈肩面膜组、真空气垫+头颈肩面膜固定组的误差数据差异均有统计学意义(P<0.05)。结论:2种不同的影像模式(CBCT与EPID)进行摆位误差的比对未见明显统计学差异,2种固定方式下头颈部真空气垫+头颈肩面膜固定的患者体位重复性更好。 展开更多
关键词 千伏级锥形束CT 兆伏级电子射野影像系统 头颈部肿瘤 摆位误差
下载PDF
非晶硅电子射野影像系统与ArcCHECK在直肠癌容积旋转调强剂量验证中的应用 被引量:9
12
作者 黎旦 宾石珍 +3 位作者 程品晶 单冬勇 成树林 张俊俊 《中国医学物理学杂志》 CSCD 2016年第7期674-677,共4页
目的:比较非晶硅电子射野影像系统(a-Si EPID)与旋转照射剂量验证仪器(Arc CHECK)在直肠癌容积旋转调强(VMAT)剂量验证中的应用。方法:随机选取20例直肠癌VMAT病例,分别设计a-Si EPID与Arc CHECK的验证计划,并在UNIQUE加速器上进行验证... 目的:比较非晶硅电子射野影像系统(a-Si EPID)与旋转照射剂量验证仪器(Arc CHECK)在直肠癌容积旋转调强(VMAT)剂量验证中的应用。方法:随机选取20例直肠癌VMAT病例,分别设计a-Si EPID与Arc CHECK的验证计划,并在UNIQUE加速器上进行验证。采用γ分析方法(3 mm,3%)比较两种不同验证工具的相对剂量与绝对剂量通过率、X和Y方向的profile。结果:Arc CHECK的绝对剂量通过率为(97.73±1.98)%,相对剂量通过率为(96.96±2.34)%;aSi EPID的绝对剂量通过率为(97.58±1.88)%,相对剂量通过率为(98.13±1.47)%。X、Y方向的profile理论值与实测值很相近,理论剂量分布图与实测计算剂量分布图在高低剂量点分布上重合度较高。结论:Arc CHECK和a-Si EPID的验证结果在剂量学上没有明显差异,两者在直肠癌VMAT剂量验证中都是可行的,但a-Si EPID操作简单、使用方便、显示剂量即时,可以更便捷地进行VMAT剂量验证。 展开更多
关键词 直肠癌 非晶硅电子射野影像系统 ARC CHECK 容积旋转调强 剂量验证
下载PDF
非晶硅电子射野影像装置在宫颈癌剂量验证中的应用 被引量:11
13
作者 黎旦 宾石珍 +3 位作者 程品晶 单冬勇 成树林 张俊俊 《中国医学物理学杂志》 CSCD 2017年第3期230-234,共5页
目的:非晶硅电子射野影像装置(a-Si EPID)分别与Arc CHECK和二维电离室矩阵(PTW729)两种验证技术在宫颈癌剂量验证中的应用比较。方法:随机选取40例宫颈癌容积旋转调强技术(VMAT)和调强放射治疗技术(IMRT)病例。在相应的模体上分别设计... 目的:非晶硅电子射野影像装置(a-Si EPID)分别与Arc CHECK和二维电离室矩阵(PTW729)两种验证技术在宫颈癌剂量验证中的应用比较。方法:随机选取40例宫颈癌容积旋转调强技术(VMAT)和调强放射治疗技术(IMRT)病例。在相应的模体上分别设计出验证计划,将验证计划分为VMAT和IMRT两组,利用a-Si EPID和Arc CHECK验证VMAT计划,a-Si EPID和PTW729验证IMRT计划,在UNIQUE加速器上进行验证。采用γ分析方法(3%,3 mm,10%标准),比较两组验证计划的相对剂量与绝对剂量通过率和X、Y方向的profile。结果:VMAT组:Arc CHECK的绝对剂量通过率为(97.73±1.98)%,相对剂量通过率为(96.96±2.34)%;a-Si EPID的绝对剂量通过率为(97.58±1.88)%,相对剂量通过率为(98.13±1.47)%。IMRT组:PTW729的绝对剂量通过率为(98.48±1.89)%,相对剂量通过率为(97.32±1.56)%;a-Si EPID的绝对剂量通过率为(98.74±1.77)%,相对剂量通过率为(97.98±1.65)%。同时两组X、Y方向的profile理论与实测很相近,理论剂量分布图与实测计算剂量分布图在高低剂量点分布上重合度较高。结论:3种验证技术的结果在剂量学上没有明显差异,但a-Si EPID具有成像分辨率高、图像处理快捷、使用方便等优点。 展开更多
关键词 非晶硅电子射野影像系统 宫颈癌 容积旋转调强 调强放射治疗 剂量验证
下载PDF
乳腺癌放射治疗真空垫固定摆位误差分析及优势 被引量:19
14
作者 曹鸿斌 任伟 +3 位作者 于靓杰 高美梅 吴旭东 白永瑞 《中国癌症杂志》 CAS CSCD 北大核心 2012年第4期283-286,共4页
背景与目的:目前国内乳腺癌放射治疗使用乳腺托架固定摆位的精度较高,但许多单位没有大孔径CT,因此乳腺托架无法使用。该研究旨在探讨在没有大孔径CT时,乳腺癌术后患者在放射治疗时使用真空垫固定的摆位误差和产生原因。方法:选取2011... 背景与目的:目前国内乳腺癌放射治疗使用乳腺托架固定摆位的精度较高,但许多单位没有大孔径CT,因此乳腺托架无法使用。该研究旨在探讨在没有大孔径CT时,乳腺癌术后患者在放射治疗时使用真空垫固定的摆位误差和产生原因。方法:选取2011年11月—2012年2月期间上海交通大学医学院仁济医院放疗科收治的30例乳腺癌术后患者,接受放射治疗并用真空垫固定进行CT定位,使用医科达Precise型加速器上兆伏级电子射野影像系统(electron portal imaging device,EPID)对患者实施锁骨上野和胸壁切线野拍片,并与治疗计划中的射野位置对比验证,统计出X、Y、Z轴3个方向的平均误差及最大误差。结果:X、Y、Z轴平均误差分别为(1.61±1.12)、(1.56±1.12)和(1.50±0.9)mm。结论:乳腺癌术后患者使用真空负压成型垫固定,能保证摆位的精度,在没有固定架条件下实用性高。 展开更多
关键词 乳腺癌 真空垫 电子射野影象系统 摆位误差
下载PDF
电子射野影像装置用于监控放射治疗中初次摆位误差的研究 被引量:12
15
作者 沈海英 沈琰琦 +3 位作者 李永春 陈剑 夏怡 李云海 《生物医学工程与临床》 CAS 2010年第4期303-305,共3页
目的利用电子射野影像装置(EPID)对不同部位肿瘤放射治疗中的初次摆位误差进行量化分析,了解不同部位的摆位误差,了解不同医生对摆位误差的接受程度有无差异。方法 2006年1月~2007年12月接受放射治疗的患者中按头颈、胸部、腹盆腔不... 目的利用电子射野影像装置(EPID)对不同部位肿瘤放射治疗中的初次摆位误差进行量化分析,了解不同部位的摆位误差,了解不同医生对摆位误差的接受程度有无差异。方法 2006年1月~2007年12月接受放射治疗的患者中按头颈、胸部、腹盆腔不同部位,按不同医生治疗组随机选取58例,其中男性30例,女性28例;年龄23~86岁,平均年龄56.9岁。按部位分别为头及头颈部20例,胸部19例,腹盆部19例。采用双曝光法拍摄照射野验证片。参考图像为CT定位后的数字重建图像(DRR)或X射线模拟机定位图像,图像比较采用骨性结构为标志,勾画出参考图像上的骨性结构,与EPID进行最大程度重合后得出在水平、垂直方向上的摆位误差数据并进行分析。结果摆位误差水平方向为(1.02±1.15)mm(0~5mm),垂直方向为(1.11±1.20)mm(0~6mm)。90%以上摆位误差小于3mm。头部或头颈部固定摆位误差最小,水平方向和垂直方向分别为(0.64±0.65)mm和(0.91±0.98)mm。不同医生组之间摆位误差无明显统计学意义。在不同部位治疗中,在垂直方向摆位误差上,头及头颈部固定明显小于胸部和腹盆部固定,差异有统计学意义(P=0.02)。结论绝大多数摆位误差在容许范围。实施治疗前,先行X射线模拟机摆位不失为一种缩小摆位误差的有效办法。 展开更多
关键词 电子射野影像装置 摆位误差 体位固定 放射疗法
下载PDF
基于非晶硅电子射野影像装置的剂量响应研究 被引量:10
16
作者 徐寿平 王石 +2 位作者 吴朝霞 解传滨 戴相昆 《中国医学物理学杂志》 CSCD 2012年第3期3380-3385,共6页
目的:临床条件下研究探讨非晶硅电子射野影像装置(a-Si EPID)的剂量响应特性。方法 :本实验在Elekta Precise直线加速器上X射线能量分别为6 MV和10 MV,采用PTW电离室、等效固体水和不同厚度铜板条件下实施测量。首先,通过EPID信号和模... 目的:临床条件下研究探讨非晶硅电子射野影像装置(a-Si EPID)的剂量响应特性。方法 :本实验在Elekta Precise直线加速器上X射线能量分别为6 MV和10 MV,采用PTW电离室、等效固体水和不同厚度铜板条件下实施测量。首先,通过EPID信号和模体中电离室的测量比较,确定出EPID剂量响应的建成厚度。其次,临床条件下利用模体的不同厚度测量分析有关剂量、每脉冲剂量和脉冲重复频率(PRF)函数的EPID信号响应情况。结果:在不增加建成材料、10 cm~60cm空气间隙条件下EPID显示了最大11.6%的过响应信号变化。临床上额外将3 mm铜建成区置于EPID上方,空气间隙大于40 cm条件下EPID响应变化将会降至1%以内。在测量范围内随MU数、PRF和每脉冲剂量变化的EPID信号响应是非线性的,最大信号变化接近于3%。因假峰和图像滞后效应等影响,短时间照射EPID会明显地产生出低剂量响应。结论:采用合适的建成层和实施对每脉冲剂量、PRF等校正,非晶硅EPID剂量响应变化可控制在1%以内,从而建立起较为理想的剂量响应曲线。 展开更多
关键词 非晶硅电子射野影像装置(a-Si EPID) 剂量响应 入射剂量
下载PDF
电子射野影像系统(EPID)在头颈部肿瘤放射治疗中的摆位误差分析及质量控制 被引量:16
17
作者 于长华 韩济华 +3 位作者 朱振亚 张晓晔 朱卫国 李涛 《中国医学物理学杂志》 CSCD 2009年第3期1154-1155,1183,共3页
目的:通过电子射野影像系统(Electron PortalImaging Device,EPID)测定和分析三维适形及调强放疗中的摆位误差,并依此计算CTV外扩PTV边界的大小,定期分析误差原因,不断提高科室的质量控制水平。方法:对2007年10月份开始连续四个月月份... 目的:通过电子射野影像系统(Electron PortalImaging Device,EPID)测定和分析三维适形及调强放疗中的摆位误差,并依此计算CTV外扩PTV边界的大小,定期分析误差原因,不断提高科室的质量控制水平。方法:对2007年10月份开始连续四个月月份各12、11、17、16例头颈部肿实行适形或调强放疗的肿瘤患者进行摆位误差测定,体位固定采用头颈肩膜固定,每例患者每周一次于治疗前在加速器上拍摄正、侧位等中心验证片各一张,与治疗计划系统中的DRR(Digital Reconstructed Radiograph)片比较,计算出摆位误差。CTV到PTV外扩边界的大小由公式2.0Σ+0.7σ计算得出,其中Σ为系统误差,σ为随机误差,于每月底计算本月度的CTV到PTV外扩边界数值,分析误差原因,并提出具体质控措施。结果:由公式得出我科头颈部肿瘤外扩PTV的理论边界前1、2、3月份数值呈不断下降,自4月份开始,数值呈稳定状态。结论:通过对摆位误差的分析为我科外扩CTV边界提供了理论依据,确定了CTV到PTV外扩边界的大小,通过不断的改进,使边界外扩数值不断减少,减少患者照射区域,提高治疗水平。 展开更多
关键词 放射治疗 摆位误差 边界 电子射野影像系统 质量保证
下载PDF
头颈部肿瘤调强放疗中摆位偏差的测量与分析 被引量:24
18
作者 沈君姝 王健琪 +2 位作者 张宜勤 翟振宇 荆西京 《第四军医大学学报》 北大核心 2006年第12期1147-1149,共3页
目的:测定头颈部肿瘤在调强放射治疗中的摆位偏差,分析计划设计中从临床靶区(CTV)到计划靶区(PTV)的外扩边界.方法:随机抽取76名头颈部肿瘤患者,在治疗时用电子射野影像装置(EPID)拍摄射野片,将射野片和计划系统中的数字重建射野(DRR)... 目的:测定头颈部肿瘤在调强放射治疗中的摆位偏差,分析计划设计中从临床靶区(CTV)到计划靶区(PTV)的外扩边界.方法:随机抽取76名头颈部肿瘤患者,在治疗时用电子射野影像装置(EPID)拍摄射野片,将射野片和计划系统中的数字重建射野(DRR)图像片进行误差比较.结果:在左右、头脚、腹背方向的摆位误差分别是(-0.62±1.46)mm,(-0.41±1.54)mm,(-0.31±1.67)mm,外扩边界分别是2.27mm,1.87mm,1.98mm.结论:对于头颈部调强治疗的患者,CTV到PTV的外放边界在左右方向需要2.5mm,头脚方向和腹背方向需要2mm.并且随着治疗时间的递进,摆位误差没有规律性的变化. 展开更多
关键词 头颈部肿瘤 摆位误差 电子射野影像装置 数字重建图像
下载PDF
基于射线追踪的数字重建影像增强技术 被引量:6
19
作者 汪俊 吴章文 +1 位作者 张从华 侯氢 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2005年第1期125-128,142,共5页
数字重建影像是放射治疗虚拟模拟过程中的一项关键技术 ,对于放疗过程中的质量控制具有非常重要的意义。本研究基于物理的角度将射线追踪法运用于数字影像重建。在处理过程中 ,采用了一种新的数字重建影像增强算法 ,即对密度进行指数变... 数字重建影像是放射治疗虚拟模拟过程中的一项关键技术 ,对于放疗过程中的质量控制具有非常重要的意义。本研究基于物理的角度将射线追踪法运用于数字影像重建。在处理过程中 ,采用了一种新的数字重建影像增强算法 ,即对密度进行指数变换 ,通过调整衰减系数和密度指数来实现高密度组织与低密度组织间对比度的提高 ,实验结果表明该算法能明显改善图像质量。为了节省内存开销 ,在追踪过程中采用了逐层插值追踪的办法。 展开更多
关键词 射线追踪 数字重建影像增强技术 放射治疗 质量控制 图像质量
下载PDF
基于EPID的容积旋转调强放疗绝对剂量验证探讨 被引量:4
20
作者 孟慧鹏 董化江 +5 位作者 丁红军 孙小喆 郑爱青 梁克明 张艳龙 王鹏 《医疗卫生装备》 CAS 2016年第8期98-100,108,共4页
目的:探讨电子射野影像装置(electronic portal imaging device,EPID)用于容积旋转调强放疗(volumetric modulated arc therapy,VMAT)绝对剂量验证的可行性与在临床应用中的意义。方法 :随机选取100例患者的VMAT治疗计划,用Eclipse软件... 目的:探讨电子射野影像装置(electronic portal imaging device,EPID)用于容积旋转调强放疗(volumetric modulated arc therapy,VMAT)绝对剂量验证的可行性与在临床应用中的意义。方法 :随机选取100例患者的VMAT治疗计划,用Eclipse软件导出EPID计划和水模体验证计划等中心平面的通量图。在2幅通量图中对应位置处,各随机选取30个待测量绝对剂量点(靶区内6个,靶区外扩5、10、20、30、50 mm的区域内和有效探测范围内各4个点),按照选取位置的不同将这些剂量点分成7组,每个点均测量EPID和指形电离室实测值,用单因素F检验比较2种方法7组数据的计划值与实测值准确率的差异。结果 :7组剂量点的绝对剂量验证结果准确率基本均在98%以上,2种方法测量的7组数据的准确率均无统计学差异(F=0.032-3.189,P>0.05)。结论:EPID具有在线实时剂量验证的潜力和明显优势,能够大大提高多点绝对剂量验证的效率,可以用于VMAT治疗绝对剂量的验证。 展开更多
关键词 电子射野影像装置 容积调强 剂量验证
下载PDF