Experimental Study on the Cyclic Ampacity and Its Factor of 10 kV XLPE Cable 被引量:1
1
作者 Xiaoliang Zhuang Haiqing Niu +2 位作者 Junfeng Wang Yong You Guanghui Sun 《Energy and Power Engineering》 2013年第4期1221-1225,共5页
The load varies periodically, but the peak current of power cable is controlled by its continuous ampacity in China, resulting in the highest conductor temperature is much lower than90℃, the permitted long-term worki... The load varies periodically, but the peak current of power cable is controlled by its continuous ampacity in China, resulting in the highest conductor temperature is much lower than90℃, the permitted long-term working temperature of XLPE. If the cable load is controlled by its cyclic ampacity, the cable transmission capacity could be used sufficiently. To study the 10 kV XLPE cable cyclic ampacity and its factor, a three-core cable cyclic ampacity calculation software is developed and the cyclic ampacity experiments of direct buried cable are undertaken in this paper. Experiments and research shows that the software calculation is correct and the circuit numbers and daily load factor have an important impact on the cyclic ampacity factor. The cyclic ampacity factor of 0.7 daily load factor is 1.20, which means the peak current is the 1.2 times of continuous ampacity. If the continuous ampacity is instead by the cyclic ampacity to control the cable load, the transmission capacity of the cable can be improved greatly without additional investment. 展开更多
关键词 XLPE CABLE EXPERIMENT CYCLIC ampacity Software
下载PDF
Configuration Optimization of Cables in Ductbank Based on Their Ampacity
2
作者 Bin Sun Elham Makram 《Journal of Power and Energy Engineering》 2018年第4期1-15,共15页
Electrical power companies are using more underground cables rather than overhead lines to distribute power to their customers. In practice, cables are generally installed in some compact ductbanks. Since the cost of ... Electrical power companies are using more underground cables rather than overhead lines to distribute power to their customers. In practice, cables are generally installed in some compact ductbanks. Since the cost of underground cables is very expensive, using the entire space of a ductbank is extremely important. But such usage is limited due to the overheating of cables. Overheating is generally caused by overload, which means the carrying current exceeds the ampacity of a cable. The ampacity of a cable depends on not only the material and design of a cable but also the distance between different cables. Thus the configuration of cables determines the total ampacity value and the potential use of a ductbank. In this paper, the best configuration based on ampacity is achieved for a three-row, five-column ductbank that is buried at a depth of one meter below the earth’s surface. Both balanced and unbalanced scenarios are considered, and all cables have two available types to be selected. 展开更多
关键词 CONFIGURATION OPTIMIZATION UNDERGROUND Cables ampacity BALANCED Unbalanced
下载PDF
采用AMPAC方法关于饱和胺的基态和第一电子激发态分子构型理论计算
3
作者 邢波 《现代科学仪器》 2009年第1期90-91,共2页
采用AMPAC计算机化学软件进行三级饱和胺的基态和第一电子激发态的分子构型计算。得到了饱和胺的氮原子键角度(L)及其键角度和(∑A_(C-N-CH_3)),说明处于第一电子激发态时,胺分子几何构型与基态时相比呈平面化趋势。激发态单胺几乎呈平... 采用AMPAC计算机化学软件进行三级饱和胺的基态和第一电子激发态的分子构型计算。得到了饱和胺的氮原子键角度(L)及其键角度和(∑A_(C-N-CH_3)),说明处于第一电子激发态时,胺分子几何构型与基态时相比呈平面化趋势。激发态单胺几乎呈平面状;对于双胺和三胺,一个氮原子键角度呈直线型,其它氮原子键角度几乎没有变化。 展开更多
关键词 AMPAC 键角 几何构型
下载PDF
Implementation of Dynamic Line Rating in a Sub-Transmission System for Wind Power Integration
4
作者 Saifal Talpur Carl Johan Wallnerstrom +1 位作者 Patrik Hilber Christer Flood 《Smart Grid and Renewable Energy》 2015年第8期233-249,共17页
Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with n... Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with new line constructions, the overhead lines are therefore required to be rated based on a method that should establish their real-time capability in terms of electricity transmission. The method used to determine the real-time ampacity of overhead conductors not only can enhance their transmission capacity but can also help in allowing excessive renewable generation in the electricity network. In this research work, the issues related to analyzing an impact of wind power on periodical loading of overhead line as well as finding its static and dynamic ampacities with line current are investigated in detail. Moreover, the investigation related to finding a suitable location for the construction of a 60 MW wind farm is taken on board. Thereafter, the wind park is integrated with a regional grid, owned by Fortum Distribution AB. In addition to that, the electricity generated from the wind park is also calculated in this project. Later on, the work is devoted to finding the static and dynamic line ratings for “VL3” overhead conductor by using IEEE-738-2006 standard. Furthermore, the project also deals with finding the line current and making its comparison with maximum capacity of overhead conductor (VL3) for loading it in such a way that no any violation of safe ground clearance requirements is observed at all. Besides, the line current, knowing the conductor temperature when it transmits the required electricity in the presence of wind power generation is also an important factor to be taken into consideration. Therefore, based on real-time ambient conditions with actual line loading and with the help of IEEE-738-2006 standard, the conductor temperature is also calculated in this project. At the end, an economic analysis is performed to evaluate the financial advantages related to applying the dynamic line ratings approach in place of traditional static line ratings technique across an overhead conductor (VL3) and to know how much beneficial it is to temporarily postpone the rebuilding and/or construction of a new transmission line. Furthermore, an economic analysis related to wind power system is taken into consideration as well to get familiar with the costs related to building and connecting a 60 MW wind farm with the regional grid. 展开更多
关键词 Overhead Conductor STATIC and DYNAMIC Ampacities Real-Time Weather Conditions STATIC and DYNAMIC LINE RATING Techniques WIND Power Integration Regional Grid LINE Current. Conductor Temperature WIND Power ECONOMICS DYNAMIC LINE RATING ECONOMICS
下载PDF
反应机制的理论研究及AMPAC程序包简介 被引量:1
5
作者 揭草仙 《化学通报》 CAS CSCD 北大核心 1990年第3期9-14,共6页
化学最基本的问题之一是要知道化学反应是怎样发生的。遗憾的是它不能完全由实验来解决。
关键词 反应机制 AMPAC程序包
原文传递
Formulations and Approximations of Branch Flow Model for General Power Networks
6
作者 Zhao Yuan 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1110-1126,共17页
The formulations and approximations of the branch flow model for general(radial and mesh) power networks(General-BranchFlow) are given in this paper. Using different sets of the power flow equations, six formats of th... The formulations and approximations of the branch flow model for general(radial and mesh) power networks(General-BranchFlow) are given in this paper. Using different sets of the power flow equations, six formats of the exact General-BranchFlow model are listed. The six formats are mathematically equivalent with each other. Linear approximation and second-order cone programming(SOCP) are then used to derive the six formats of the convex General-BranchFlow model. The branch ampacity constraints considering the shunt conductance and capacitance of the transmission line Π-model are derived. The key foundation of deriving the ampacity constraints is the correct interpretation of the physical meaning of the transmission line Π-model. An exact linear expression of the ampacity constraints of the power loss variable is derived. The applications of the General-BranchFlow model in deriving twelve formats of the exact optimal power flow(OPF) model and twelve formats of the approximate OPF model are formulated and analyzed. Using the Julia programming language, the extensive numerical investigations of all formats of the OPF models show the accuracy and computational efficiency of the General-BranchFlow model. A penalty function based approximation gap reduction method is finally proposed and numerically validated to improve the AC-feasibility of the approximate General-BranchFlow model. 展开更多
关键词 Branch flow linear approximation second-order cone programming ampacity constraint optimal power flow radial network mesh network
原文传递