With the large-scale construction of underground gas storage in salt deposit, much more efforts have been made to assess the fatigue properties of rock salt. The fatigue damage processes the primary, steady,and accele...With the large-scale construction of underground gas storage in salt deposit, much more efforts have been made to assess the fatigue properties of rock salt. The fatigue damage processes the primary, steady,and accelerated phases, which is similar to the axial irrecoverable deformation compiled from the loci of the loading cycles of rock salt. The cumulative fatigue damage increases with a decrease in the loading frequency and with an increase in the stress amplitude within the range tested. To take into account the effects of loading frequency and amplitude on the fatigue behavior of rock salt subjected to cyclic loading, a low cycle fatigue damage model was exclusively established combined with the Manson–Coffin formula. The proposed damage evolution equation was validated with experimental results and proved to be efficient in the prediction of fatigue damage tendency of rock salt under different loading frequencies and amplitudes.展开更多
The amplitude of frequency spectrum can he integrated with prohabilisfic data association (PDA) to distinguish the target with clutter echoes, especially in low SNR underwater environment. A new target-tracking algo...The amplitude of frequency spectrum can he integrated with prohabilisfic data association (PDA) to distinguish the target with clutter echoes, especially in low SNR underwater environment. A new target-tracking algorithm is presented which adopts the amplitude of frequency spectrum to improve target tracking in clutter. The prohabilisfic density distribution of frequency spectrum amplitude is analyzed. By simulation, the results show that the algorithm is superior to PDA. This approach enhances stability for the association probability and increases the performance of target tracking.展开更多
In the past century, there have been many attempts to treat cancer with low levels of electric and magnetic fields. We have developed noninvasive biofeedback examination devices and techniques and discovered that pati...In the past century, there have been many attempts to treat cancer with low levels of electric and magnetic fields. We have developed noninvasive biofeedback examination devices and techniques and discovered that patients with the same tumor type exhibit biofeedback responses to the same, precise frequencies. Intrabuccal administration of 27.12 MHz radiofrequency(RF) electromagnetic fields(EMF), which are amplitude-modulated at tumor-specific frequencies, results in long-term objective responses in patients with cancer and is not associated with any significant adverse effects. Intrabuccal administration allows for therapeutic delivery of very low and safe levels of EMF throughout the body as exemplified by responses observed in the femur, liver, adrenal glands, and lungs. In vitro studies have demonstrated that tumor-specific frequencies identified in patients with various forms of cancer are capable of blocking the growth of tumor cells in a tissue- and tumor-specific fashion. Current experimental evidence suggests that tumor-specific modulation frequencies regulate the expression of genes involved in migration and invasion and disrupt the mitotic spindle. This novel targeted treatment approach is emerging as an appealing therapeutic option for patients with advanced cancer given its excellent tolerability. Dissection of the molecular mechanisms accounting for the anti-cancer effects of tumor-specific modulation frequencies is likely to lead to the discovery of novel pathways in cancer.展开更多
It is now well known that amplitude modulated(AM) high frequency(HF) radio wave transmissions into the ionosphere can be used to generate very/extremely low frequency(VLF/ELF) radio waves using the so-called ‘electro...It is now well known that amplitude modulated(AM) high frequency(HF) radio wave transmissions into the ionosphere can be used to generate very/extremely low frequency(VLF/ELF) radio waves using the so-called ‘electrojet antenna’. Duty cycle and heating frequency are analyzed and discussed with the lower-ionosphere modulated heating model, so as to improve the radiation efficiency of VLF/ELF waves in AM ionospheric heating experiments. Based on numerical simulation, the ranges of parametric selectivity in optimal duty cycle and heating frequency( fHF) are derived. The International Reference Ionosphere 2015(IRI-2015) model and two-parameter model are used to predict background electron density profiles, and optimized ranges of duty cycle for different density profiles are analyzed and compared. The influences of wave polarizations on optimal duty cycle are also discussed. It is shown that intensity of the VLF/ELF equivalent radiation source(M) firstly rises and then falls with the increase of duty cycle. When using the IRI model, M peaks at a duty cycle of 50%, optimally ranging from 40%-70%. For the two-parameter model case, an optimal duty cycle is 40% and the optimized ranges vary from 30%-60%. Heating with an X-mode polarization is more efficient than with the O-mode case in VLF/ELF wave generation. Nevertheless, an optimal duty cycle is almost independent of HF wave polarizations. To obtain better VLF/ELF generation, optional fHFmay be 0.8-0.9 times of foE for the O-mode heating and 0.75-0.85 times for the X-mode polarization case. Finally, the variations of these two parameters in different latitudes are discussed.展开更多
Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately...Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately deriving quantitative information from sound pressure measured in the ear canal. In this study, a novel signal processing method for multicomponent analysis (MCA) was used to measure the amplitude and delay of the SFOAE. This report shows the delay-frequency distribution of the SFOAE measured from the human ear. A low level acoustical suppressor near the probe tone significantly suppressed the SFOAE, strongly indicating that the SFOAE was generated at characteristic frequency locations. Information derived from this method may reveal more details of cochlear mechanics in the human ear.展开更多
BACKGROUND Major depressive disorder(MDD)tends to have a high incidence and high suicide risk.Electroconvulsive therapy(ECT)is currently a relatively effective treatment for MDD.However,the mechanism of efficacy of EC...BACKGROUND Major depressive disorder(MDD)tends to have a high incidence and high suicide risk.Electroconvulsive therapy(ECT)is currently a relatively effective treatment for MDD.However,the mechanism of efficacy of ECT is still unclear.AIM To investigate the changes in the amplitude of low-frequency fluctuations in specific frequency bands in patients with MDD after ECT.METHODS Twenty-two MDD patients and fifteen healthy controls(HCs)were recruited to this study.MDD patients received 8 ECT sessions with bitemporal placement.Resting-state functional magnetic resonance imaging was adopted to examine regional cerebellar blood flow in both the MDD patients and HCs.The MDD patients were scanned twice(before the first ECT session and after the eighth ECT session)to acquire data.Then,the amplitude of low-frequency fluctuations(ALFF)was computed to characterize the intrinsic neural oscillations in different bands(typical frequency,slow-5,and slow-4 bands).RESULTS Compared to before ECT(pre-ECT),we found that MDD patients after the eighth ECT(post-ECT)session had a higher ALFF in the typical band in the right middle frontal gyrus,posterior cingulate,right supramarginal gyrus,left superior frontal gyrus,and left angular gyrus.There was a lower ALFF in the right superior temporal gyrus.Compared to pre-ECT values,the ALFF in the slow-5 band was significantly increased in the right limbic lobe,cerebellum posterior lobe,right middle orbitofrontal gyrus,and frontal lobe in post-ECT patients,whereas the ALFF in the slow-5 band in the left sublobar region,right angular gyrus,and right frontal lobe was lower.In contrast,significantly higher ALFF in the slow-4 band was observed in the frontal lobe,superior frontal gyrus,parietal lobe,right inferior parietal lobule,and left angular gyrus.CONCLUSION Our results suggest that the abnormal ALFF in pre-and post-ECT MDD patients may be associated with specific frequency bands.展开更多
Amplitude quantization is one of the main sources of spurious noise frequencies in Direct Digital Frequency Synthesizers (DDFSs), which affect their application to many wireless telecommu- nication systems. In this pa...Amplitude quantization is one of the main sources of spurious noise frequencies in Direct Digital Frequency Synthesizers (DDFSs), which affect their application to many wireless telecommu- nication systems. In this paper, two different kinds of spurious signals due to amplitude quantization in DDFSs are exactly formulated in the time domain and detailedly compared in the frequency do- main, and the effects of the DDFS parameter variations on the spurious performance are thoroughly studied. Then the spectral properties and power levels of the amplitude-quantization spurs in the absence of phase-accumulator truncation are emphatically analyzed by waveform estimation and computer simulation, and several important conclusions are derived which can provide theoretical support for parameter choice and spurious performance evaluation in the application of DDFSs.展开更多
The transports of the dynamic biochemical signals in the non-reversing pulsatile flows in the mixing microchannel of a Y-shaped microfluidic device are ana- lyzed. The results show that the mixing micro-channel acts a...The transports of the dynamic biochemical signals in the non-reversing pulsatile flows in the mixing microchannel of a Y-shaped microfluidic device are ana- lyzed. The results show that the mixing micro-channel acts as a low-pass filter, and the biochemical signals are nonlinearly modulated by the pulsatile flows, which depend on the biochemical signal frequency, the flow signal frequency, and the biochemical signal transporting distance. It is concluded that, the transfer characteristics of the dynamic biochemical signals, which are transported in the time-varying flows, should be carefully considered for better loading biochemical signals on the cells cultured on the bottom of the microfluidic channel.展开更多
Two types of elastomeric vibration isolators used for equipment vibration isolation in aerospace vehicles are considered for the present study. These isolators are constructed using elastomers mounted in steel encasin...Two types of elastomeric vibration isolators used for equipment vibration isolation in aerospace vehicles are considered for the present study. These isolators are constructed using elastomers mounted in steel encasings. These isolators are initially deformed statically and dynamic loads are applied on the deformed configuration. To capture the static deformation, equivalent static load corresponding to its load rating and specified displacements are created. Static deformation is computed using Finite Element methods with four node axi-symmetric element which include the geometric non-linear effect for steel and with standard Yeoh hyper-elastic material model for elastomers(Muhammed and Zu, 2012) [1]. Yeoh material constants are derived from uni-axial tension test data of the elastomer specimen. These isolators are subjected to harmonic and random excitations in the pre-deformed state. For numerical analysis, elastomeric constants at dynamic conditions are obtained as complex function of frequency using Dynamic Mechanical Analyzer(DMA) for a range of frequencies. The standard material model of Yeoh is modified incorporating frequency dependant material characteristics and damping in the range of frequencies of interest. A multiplicative non-separable variables law is derived for Yeoh material model to include the effect of static pre-stress, based on the methodology given in literature(Nashif et al.,1985;Beda et al., 2014) [2,3]. The modifications of Yeoh model suitable for frequency domain analysis is the novelty in the present study. In the analysis, while dynamic loads are applied, the configuration is updated considering initial static loading. The frequency response of the isolators is computed using material properties evaluated at progressive dynamic strains until a match in natural frequency is observed. Appropriate damping corrections are then incorporated to match the test observed transmissibility. Then updated material properties are used to compute the random response which showed good agreement with results of experiments, validating the approach taken for the development of this model.展开更多
A linear model of three layers plane wall exposed to oscillating temperatures with different amplitudes and frequencies was built by using a physical superposition. A physical superposition of two states was performed...A linear model of three layers plane wall exposed to oscillating temperatures with different amplitudes and frequencies was built by using a physical superposition. A physical superposition of two states was performed, one state is a wall which one surface is exposed to oscillating temperature and the other surface is exposed to zero relative temperature and a second state is a wall which one surface is exposed to relative zero temperature while the other surface is exposed to oscillating temperature with different amplitudes and frequencies. Temperature distributions were introduced for different amplitudes, frequencies and thermal conductivities. It was shown that increasing the frequency value decreases the temperature penetration length, high frequency value leads to extremum temperature values changes on the surface while low frequency value allows gradually temperature changes during the time period. Temperature distribution lines where there are at the same time heat flux entry and heat flux exit were not received for the same constraint frequencies.展开更多
In this paper, three existing source spectral models for stochastic finite-fault modeling of ground motion were reviewed. These three models were used to calculate the far-field received energy at a site from a vertic...In this paper, three existing source spectral models for stochastic finite-fault modeling of ground motion were reviewed. These three models were used to calculate the far-field received energy at a site from a vertical fault and the mean spectral ratio over 15 stations of the Northridge earthquake, and then compared. From the comparison, a necessary measure was observed to maintain the far-field received energy independent of subfault size and avoid overestimation of the long- period spectra/level. Two improvements were made to one of the three models (i.e., the model based on dynamic comer frequency) as follows: (i) a new method to compute the subfault comer frequency was proposed, where the subfault comer frequency is determined based on a basic value calculated from the total seismic moment of the entire fault and an increment depending on the seismic moment assigned to the subfault; and (ii) the difference of the radiation energy from each suhfault was considered into the scaling factor. The improved model was also compared with the unimproved model through the far-field received energy and the mean spectral ratio. The comparison proves that the improved model allows the received energy to be more independent of subfault size than the unimproved model, and decreases the overestimation degree of the long-period spectral amplitude.展开更多
We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s ave...We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s averaging time is achieved,and the frequency reproducibility has a relative uncertainty of 3.5×10^(-13),demonstrating the great stability of our setup.The systematic uncertainty of the iodine-stabilized laser frequency standard is evaluated,especially the contribution of the residual amplitude modulation(RAM).The contribution of the RAM in MTS cannot be evaluated directly.To solve this problem,we theoretically deduce the MTS signal with RAM under large modulation depth,and prove that the non-symmetric shape of the MTS signal is directly related to the MTS effect.The non-symmetric shape factor can be calibrated with a frequency comb,and in real experiments,this value can be obtained by least-squares fitting of the MTS signal,from which we can infer the RAMinduced frequency shift.The full frequency uncertainty is evaluated to be 5.3 kHz(corresponding to a relative frequency uncertainty of 9.4×10^(-12)).The corrected transition frequency has a difference from the BIPM-recommended value of 2 kHz,which is within 1σ uncertainty,proving the validity of our evaluation.展开更多
Resonance drilling is a new technology, still at the laboratory stage. It has great potential to improve rock fragmentation efficiency. We analyzed the amplitude-frequency characteristics of steady- state mechanical v...Resonance drilling is a new technology, still at the laboratory stage. It has great potential to improve rock fragmentation efficiency. We analyzed the amplitude-frequency characteristics of steady- state mechanical vibration excited by harmonic vibration in rocks and an apparatus was built to achieve high fi'equency vibration of rock. The influence of rock drillability, rotary speed, excitation frequency, and other parameters on the rate of penetration (ROP) in resonance drilling was analyzed. The results show that the rock drillability decreased with an increase in excitation frequency. When drilling with a large size drill bit, the ROP increased with excitation frequency. The ROP reached a maximum value at the resonant frequency of the rock. Tile ROP of the bit increased linearly with rotary speed when no vibration was applied on the rock and increased approximately exponentially when harmonic vibration was applied. In addition, the resonant frequency of the rock was changing during the process of rock fi'agmentation, so in order to achieve tile desired resonance of the rock, it is necessary to detemaine an appropriate hamlonic vibration excitation frequency.展开更多
We propose a nonlinear ultrasonic technique by using the mixed-frequency signals excited Lamb waves to conduct micro-crack detection in thin plate structures.Simulation models of three-dimensional(3D)aluminum plates a...We propose a nonlinear ultrasonic technique by using the mixed-frequency signals excited Lamb waves to conduct micro-crack detection in thin plate structures.Simulation models of three-dimensional(3D)aluminum plates and composite laminates are established by ABAQUS software,where the aluminum plate contains buried crack and composite laminates comprises cohesive element whose thickness is zero to simulate delamination damage.The interactions between the S0 mode Lamb wave and the buried micro-cracks of various dimensions are simulated by using the finite element method.Fourier frequency spectrum analysis is applied to the received time domain signal and fundamental frequency amplitudes,and sum and difference frequencies are extracted and simulated.Simulation results indicate that nonlinear Lamb waves have different sensitivities to various crack sizes.There is a positive correlation among crack length,height,and sum and difference frequency amplitudes for an aluminum plate,with both amplitudes decreasing as crack thickness increased,i.e.,nonlinear effect weakens as the micro-crack becomes thicker.The amplitudes of sum and difference frequency are positively correlated with the length and width of the zero-thickness cohesive element in the composite laminates.Furthermore,amplitude ratio change is investigated and it can be used as an effective tool to detect inner defects in thin 3D plates.展开更多
Spurious signals in direct digital frequency synthesizers (DDFSs) are partly caused by amplitude quantization and phase truncation, which affect their application to many wireless telecommunication systems. These si...Spurious signals in direct digital frequency synthesizers (DDFSs) are partly caused by amplitude quantization and phase truncation, which affect their application to many wireless telecommunication systems. These signals are deterministic and periodic in the time domain, so they appear as line spectra in the frequency domain. Two types of spurious signals due to amplitude quantization are exactly formulated and compared in the time and frequency domains respectively. Then the frequency spectra and power levels of the spurious signals due to amplitude quantization in the absence of phase-accumulator truncation are emphatically analyzed, and the effects of the DDFS parameter variations on the spurious signals are thoroughly studied by computer simulation. And several important conclusions are derived which can provide theoretical support for parameter choice and spurious performance evaluation in the application of DDFSs.展开更多
One of the most important parameters for oceanic internal waves (IWs) is their amplitude. We have developed a method to retrieve the IW amplitude from nautical X-Band radar images based on the KdV equation for continu...One of the most important parameters for oceanic internal waves (IWs) is their amplitude. We have developed a method to retrieve the IW amplitude from nautical X-Band radar images based on the KdV equation for continuous stratified finite depth system. We have also tested the method of measuring the amplitude of IWs from X-Band radar backscatter image sequences acquired on June 2009 in the northeastern South China Sea. The method was applied in several radar images. Experiments show that the retrieval amplitudes are consistent with the in-situ observational amplitudes of IWs by using the towed thermistor chain and conductivity-temperature-depth (CTD) profile. The uncertainty of the method is also discussed.展开更多
In order to search for the seismic wave characteristics of low frequency signals in the Alxa Left Banner region,Inner Mongolia,the low frequency signals of seismic wave data are extracted from the earthquakes of MS5. ...In order to search for the seismic wave characteristics of low frequency signals in the Alxa Left Banner region,Inner Mongolia,the low frequency signals of seismic wave data are extracted from the earthquakes of MS5. 8 in 2015 and MS5. 0 in 2016 in this area. The results show that:① Before the MS5. 8 earthquake,the seismic stations located near the epicenter in Wuhai,Dongshengmiao,and Shizuishan recorded seismic waves that showed the phenomenon of spectrum shift from high to low frequency.② The low frequency signals recorded by different stations have obvious difference.③ According to the data recorded by the station closest to the epicenter,low-frequency signals were recorded about120 hours before the earthquake and had obvious anomalies. This may reflect slow slip before the earthquake.展开更多
In the present communication, the hydrodynamic model is used to investigate the amplitude modulation as well as demodulation of an electromagnetic wave of high power helicon pump wave into another helicon wave in stra...In the present communication, the hydrodynamic model is used to investigate the amplitude modulation as well as demodulation of an electromagnetic wave of high power helicon pump wave into another helicon wave in strain dependent dielectric material incorporating carrier heating (CH) effects. The consideration of CH in modulation and demodulation is prime importance for the adding of new dimension in analysis of amplification of acoustic helicon wave. By using the dispersion relation, threshold pump electric filed and growth rate of unstable mode from the modulation and demodulation of the high power helicon wave well above from the threshold value will be discussed in the present analysis. The numerical analysis is applied to a strain dependent dielectric material, BaTiO3 at room temperature and irradiated with high power helicon wave of frequency 1.78 × 1014 Hz. This material is very sensitive to the pump intensities, therefore during studies, Gaussian shape of the helicon pump wave is considered during the propagation in stain dependent dielectric material and opto-acoustic wave in the form of Gaussian profile (ω0,κ0) is induced longitudinally along the crystallographic plane of BaTiO3. Its variation is caused by the available magnetic field (ωc), interaction length (z) and pulsed duration of interaction (τ). From the analysis of numerical results, the incorporation of CH effect can effectively modify the magnitude of modulation or demodulation of the amplitude of high power helicon laser wave through diffusion process. Not only the amplitude modulation and demodulation of the wave, the diffusion of the CH effectively modifies the growth rate of unstable mode of frequency in BaTiO3. The propagation of the threshold electric field shows the sinusoidal or complete Gaussian profile, whereas this profile is found to be completely lost in growth of unstable mode. It has also been seen that the growth rate is observed to be of the order of 108 - 1010 s-1 but from diffusion of carrier heating, and that its order is enhanced from 1010 - 1012 s-1 with the variation of the magnetized frequency from 1 to 2.5 × 1014 Hz.展开更多
An accurate frequency synchronization method using the zadoff-chu (ZC) constant envelop preamble is analyzed, and a new preamble weighted by pseudo-noise sequence is used for orthogonal frequency division multiplexing...An accurate frequency synchronization method using the zadoff-chu (ZC) constant envelop preamble is analyzed, and a new preamble weighted by pseudo-noise sequence is used for orthogonal frequency division multiplexing (OFDM) systems. Using this method, frequency offset estimator range is greatly enlarged with no loss in accuracy. The range of the frequency estimation is ±30 of subcarrier spacing using ZC sequence as preamble. Simulations in the MATLAB for an AWGN channel show that the proposed method achieves superior performance to existing techniques in terms of frequency accuracy and range.展开更多
基金fundings and supports of the National Basic Research Program of China (No. 2013CB036005)the National Natural Science Foundation of China (Nos. 51309234, 51527810, 51304219, and 51021001)+2 种基金the Natural Science Foundation of Jiangsu Province of China (No. BK20130065)the Open Foundation of State Key Laboratory for Geomechanics and Deep Underground Engineering of China (No. SKLGDUEK1403)the China Postdoctoral Science Foundation (No. 2015M570451)
文摘With the large-scale construction of underground gas storage in salt deposit, much more efforts have been made to assess the fatigue properties of rock salt. The fatigue damage processes the primary, steady,and accelerated phases, which is similar to the axial irrecoverable deformation compiled from the loci of the loading cycles of rock salt. The cumulative fatigue damage increases with a decrease in the loading frequency and with an increase in the stress amplitude within the range tested. To take into account the effects of loading frequency and amplitude on the fatigue behavior of rock salt subjected to cyclic loading, a low cycle fatigue damage model was exclusively established combined with the Manson–Coffin formula. The proposed damage evolution equation was validated with experimental results and proved to be efficient in the prediction of fatigue damage tendency of rock salt under different loading frequencies and amplitudes.
基金This project was supported by the Defense Pre-Research Project of the‘Tenth Five-Year-Plan’of China (40105010101)
文摘The amplitude of frequency spectrum can he integrated with prohabilisfic data association (PDA) to distinguish the target with clutter echoes, especially in low SNR underwater environment. A new target-tracking algorithm is presented which adopts the amplitude of frequency spectrum to improve target tracking in clutter. The prohabilisfic density distribution of frequency spectrum amplitude is analyzed. By simulation, the results show that the algorithm is superior to PDA. This approach enhances stability for the association probability and increases the performance of target tracking.
文摘In the past century, there have been many attempts to treat cancer with low levels of electric and magnetic fields. We have developed noninvasive biofeedback examination devices and techniques and discovered that patients with the same tumor type exhibit biofeedback responses to the same, precise frequencies. Intrabuccal administration of 27.12 MHz radiofrequency(RF) electromagnetic fields(EMF), which are amplitude-modulated at tumor-specific frequencies, results in long-term objective responses in patients with cancer and is not associated with any significant adverse effects. Intrabuccal administration allows for therapeutic delivery of very low and safe levels of EMF throughout the body as exemplified by responses observed in the femur, liver, adrenal glands, and lungs. In vitro studies have demonstrated that tumor-specific frequencies identified in patients with various forms of cancer are capable of blocking the growth of tumor cells in a tissue- and tumor-specific fashion. Current experimental evidence suggests that tumor-specific modulation frequencies regulate the expression of genes involved in migration and invasion and disrupt the mitotic spindle. This novel targeted treatment approach is emerging as an appealing therapeutic option for patients with advanced cancer given its excellent tolerability. Dissection of the molecular mechanisms accounting for the anti-cancer effects of tumor-specific modulation frequencies is likely to lead to the discovery of novel pathways in cancer.
基金supported by the Innovation Fund of China Electronics Technology Group Corporation (No. KJ1602004)
文摘It is now well known that amplitude modulated(AM) high frequency(HF) radio wave transmissions into the ionosphere can be used to generate very/extremely low frequency(VLF/ELF) radio waves using the so-called ‘electrojet antenna’. Duty cycle and heating frequency are analyzed and discussed with the lower-ionosphere modulated heating model, so as to improve the radiation efficiency of VLF/ELF waves in AM ionospheric heating experiments. Based on numerical simulation, the ranges of parametric selectivity in optimal duty cycle and heating frequency( fHF) are derived. The International Reference Ionosphere 2015(IRI-2015) model and two-parameter model are used to predict background electron density profiles, and optimized ranges of duty cycle for different density profiles are analyzed and compared. The influences of wave polarizations on optimal duty cycle are also discussed. It is shown that intensity of the VLF/ELF equivalent radiation source(M) firstly rises and then falls with the increase of duty cycle. When using the IRI model, M peaks at a duty cycle of 50%, optimally ranging from 40%-70%. For the two-parameter model case, an optimal duty cycle is 40% and the optimized ranges vary from 30%-60%. Heating with an X-mode polarization is more efficient than with the O-mode case in VLF/ELF wave generation. Nevertheless, an optimal duty cycle is almost independent of HF wave polarizations. To obtain better VLF/ELF generation, optional fHFmay be 0.8-0.9 times of foE for the O-mode heating and 0.75-0.85 times for the X-mode polarization case. Finally, the variations of these two parameters in different latitudes are discussed.
基金Supported in part by research grants from the National Institute of Deafness and Other Communication Disorders(R01 DC 00141 and R03 DC033642)the National Institutes of Health+2 种基金the Research Fund of the American Otological Societythe Medical Research Foundation of OregonVA RR&D Center Grant RCTR-597-0160,Portland,VAMC
文摘Although stimulus frequency otoacoustic emissions (SFOAEs) have been used as a non-invasive measure of cochlear mechanics, clinical and experimental application of SFOAEs has been limited by difficulties in accurately deriving quantitative information from sound pressure measured in the ear canal. In this study, a novel signal processing method for multicomponent analysis (MCA) was used to measure the amplitude and delay of the SFOAE. This report shows the delay-frequency distribution of the SFOAE measured from the human ear. A low level acoustical suppressor near the probe tone significantly suppressed the SFOAE, strongly indicating that the SFOAE was generated at characteristic frequency locations. Information derived from this method may reveal more details of cochlear mechanics in the human ear.
基金Supported by the Natural Science Foundation of China,No.81901373the Intelligent Medicine Research Project of Chongqing Medical University,No.ZHYX202126.
文摘BACKGROUND Major depressive disorder(MDD)tends to have a high incidence and high suicide risk.Electroconvulsive therapy(ECT)is currently a relatively effective treatment for MDD.However,the mechanism of efficacy of ECT is still unclear.AIM To investigate the changes in the amplitude of low-frequency fluctuations in specific frequency bands in patients with MDD after ECT.METHODS Twenty-two MDD patients and fifteen healthy controls(HCs)were recruited to this study.MDD patients received 8 ECT sessions with bitemporal placement.Resting-state functional magnetic resonance imaging was adopted to examine regional cerebellar blood flow in both the MDD patients and HCs.The MDD patients were scanned twice(before the first ECT session and after the eighth ECT session)to acquire data.Then,the amplitude of low-frequency fluctuations(ALFF)was computed to characterize the intrinsic neural oscillations in different bands(typical frequency,slow-5,and slow-4 bands).RESULTS Compared to before ECT(pre-ECT),we found that MDD patients after the eighth ECT(post-ECT)session had a higher ALFF in the typical band in the right middle frontal gyrus,posterior cingulate,right supramarginal gyrus,left superior frontal gyrus,and left angular gyrus.There was a lower ALFF in the right superior temporal gyrus.Compared to pre-ECT values,the ALFF in the slow-5 band was significantly increased in the right limbic lobe,cerebellum posterior lobe,right middle orbitofrontal gyrus,and frontal lobe in post-ECT patients,whereas the ALFF in the slow-5 band in the left sublobar region,right angular gyrus,and right frontal lobe was lower.In contrast,significantly higher ALFF in the slow-4 band was observed in the frontal lobe,superior frontal gyrus,parietal lobe,right inferior parietal lobule,and left angular gyrus.CONCLUSION Our results suggest that the abnormal ALFF in pre-and post-ECT MDD patients may be associated with specific frequency bands.
基金Supported by National High-Technology Research and Development Plan of China (Grant No.2006AA01Z452)
文摘Amplitude quantization is one of the main sources of spurious noise frequencies in Direct Digital Frequency Synthesizers (DDFSs), which affect their application to many wireless telecommu- nication systems. In this paper, two different kinds of spurious signals due to amplitude quantization in DDFSs are exactly formulated in the time domain and detailedly compared in the frequency do- main, and the effects of the DDFS parameter variations on the spurious performance are thoroughly studied. Then the spectral properties and power levels of the amplitude-quantization spurs in the absence of phase-accumulator truncation are emphatically analyzed by waveform estimation and computer simulation, and several important conclusions are derived which can provide theoretical support for parameter choice and spurious performance evaluation in the application of DDFSs.
基金Project supported by the National Natural Science Foundation of China(Nos.11172060 and11672065)
文摘The transports of the dynamic biochemical signals in the non-reversing pulsatile flows in the mixing microchannel of a Y-shaped microfluidic device are ana- lyzed. The results show that the mixing micro-channel acts as a low-pass filter, and the biochemical signals are nonlinearly modulated by the pulsatile flows, which depend on the biochemical signal frequency, the flow signal frequency, and the biochemical signal transporting distance. It is concluded that, the transfer characteristics of the dynamic biochemical signals, which are transported in the time-varying flows, should be carefully considered for better loading biochemical signals on the cells cultured on the bottom of the microfluidic channel.
文摘Two types of elastomeric vibration isolators used for equipment vibration isolation in aerospace vehicles are considered for the present study. These isolators are constructed using elastomers mounted in steel encasings. These isolators are initially deformed statically and dynamic loads are applied on the deformed configuration. To capture the static deformation, equivalent static load corresponding to its load rating and specified displacements are created. Static deformation is computed using Finite Element methods with four node axi-symmetric element which include the geometric non-linear effect for steel and with standard Yeoh hyper-elastic material model for elastomers(Muhammed and Zu, 2012) [1]. Yeoh material constants are derived from uni-axial tension test data of the elastomer specimen. These isolators are subjected to harmonic and random excitations in the pre-deformed state. For numerical analysis, elastomeric constants at dynamic conditions are obtained as complex function of frequency using Dynamic Mechanical Analyzer(DMA) for a range of frequencies. The standard material model of Yeoh is modified incorporating frequency dependant material characteristics and damping in the range of frequencies of interest. A multiplicative non-separable variables law is derived for Yeoh material model to include the effect of static pre-stress, based on the methodology given in literature(Nashif et al.,1985;Beda et al., 2014) [2,3]. The modifications of Yeoh model suitable for frequency domain analysis is the novelty in the present study. In the analysis, while dynamic loads are applied, the configuration is updated considering initial static loading. The frequency response of the isolators is computed using material properties evaluated at progressive dynamic strains until a match in natural frequency is observed. Appropriate damping corrections are then incorporated to match the test observed transmissibility. Then updated material properties are used to compute the random response which showed good agreement with results of experiments, validating the approach taken for the development of this model.
文摘A linear model of three layers plane wall exposed to oscillating temperatures with different amplitudes and frequencies was built by using a physical superposition. A physical superposition of two states was performed, one state is a wall which one surface is exposed to oscillating temperature and the other surface is exposed to zero relative temperature and a second state is a wall which one surface is exposed to relative zero temperature while the other surface is exposed to oscillating temperature with different amplitudes and frequencies. Temperature distributions were introduced for different amplitudes, frequencies and thermal conductivities. It was shown that increasing the frequency value decreases the temperature penetration length, high frequency value leads to extremum temperature values changes on the surface while low frequency value allows gradually temperature changes during the time period. Temperature distribution lines where there are at the same time heat flux entry and heat flux exit were not received for the same constraint frequencies.
基金National Natural Science Foundation of China Under Grant No. 50778058 and 90715038National Key Technology R&D Program Under Contract No. 2006BAC13B02
文摘In this paper, three existing source spectral models for stochastic finite-fault modeling of ground motion were reviewed. These three models were used to calculate the far-field received energy at a site from a vertical fault and the mean spectral ratio over 15 stations of the Northridge earthquake, and then compared. From the comparison, a necessary measure was observed to maintain the far-field received energy independent of subfault size and avoid overestimation of the long- period spectra/level. Two improvements were made to one of the three models (i.e., the model based on dynamic comer frequency) as follows: (i) a new method to compute the subfault comer frequency was proposed, where the subfault comer frequency is determined based on a basic value calculated from the total seismic moment of the entire fault and an increment depending on the seismic moment assigned to the subfault; and (ii) the difference of the radiation energy from each suhfault was considered into the scaling factor. The improved model was also compared with the unimproved model through the far-field received energy and the mean spectral ratio. The comparison proves that the improved model allows the received energy to be more independent of subfault size than the unimproved model, and decreases the overestimation degree of the long-period spectral amplitude.
基金the National Key Research and Development Program of China(Grant No.2017YFA0304401)Key-Area Research and Development Program of GuangDong Province,China(Grant No.2019B030330001)the National Natural Science Foundation of China(Grant Nos.11174095,61875065,91536116,and 11804108).
文摘We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s averaging time is achieved,and the frequency reproducibility has a relative uncertainty of 3.5×10^(-13),demonstrating the great stability of our setup.The systematic uncertainty of the iodine-stabilized laser frequency standard is evaluated,especially the contribution of the residual amplitude modulation(RAM).The contribution of the RAM in MTS cannot be evaluated directly.To solve this problem,we theoretically deduce the MTS signal with RAM under large modulation depth,and prove that the non-symmetric shape of the MTS signal is directly related to the MTS effect.The non-symmetric shape factor can be calibrated with a frequency comb,and in real experiments,this value can be obtained by least-squares fitting of the MTS signal,from which we can infer the RAMinduced frequency shift.The full frequency uncertainty is evaluated to be 5.3 kHz(corresponding to a relative frequency uncertainty of 9.4×10^(-12)).The corrected transition frequency has a difference from the BIPM-recommended value of 2 kHz,which is within 1σ uncertainty,proving the validity of our evaluation.
基金funded by National Natural Science Foundation of China(Grant No.51274072)Youth Science Foundation of Heilongjiang Province(Grant No.QC2012C022)
文摘Resonance drilling is a new technology, still at the laboratory stage. It has great potential to improve rock fragmentation efficiency. We analyzed the amplitude-frequency characteristics of steady- state mechanical vibration excited by harmonic vibration in rocks and an apparatus was built to achieve high fi'equency vibration of rock. The influence of rock drillability, rotary speed, excitation frequency, and other parameters on the rate of penetration (ROP) in resonance drilling was analyzed. The results show that the rock drillability decreased with an increase in excitation frequency. When drilling with a large size drill bit, the ROP increased with excitation frequency. The ROP reached a maximum value at the resonant frequency of the rock. Tile ROP of the bit increased linearly with rotary speed when no vibration was applied on the rock and increased approximately exponentially when harmonic vibration was applied. In addition, the resonant frequency of the rock was changing during the process of rock fi'agmentation, so in order to achieve tile desired resonance of the rock, it is necessary to detemaine an appropriate hamlonic vibration excitation frequency.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61571222,61602235,and 11474160)the Six Talent Peaks Project of Jiangsu Province,China
文摘We propose a nonlinear ultrasonic technique by using the mixed-frequency signals excited Lamb waves to conduct micro-crack detection in thin plate structures.Simulation models of three-dimensional(3D)aluminum plates and composite laminates are established by ABAQUS software,where the aluminum plate contains buried crack and composite laminates comprises cohesive element whose thickness is zero to simulate delamination damage.The interactions between the S0 mode Lamb wave and the buried micro-cracks of various dimensions are simulated by using the finite element method.Fourier frequency spectrum analysis is applied to the received time domain signal and fundamental frequency amplitudes,and sum and difference frequencies are extracted and simulated.Simulation results indicate that nonlinear Lamb waves have different sensitivities to various crack sizes.There is a positive correlation among crack length,height,and sum and difference frequency amplitudes for an aluminum plate,with both amplitudes decreasing as crack thickness increased,i.e.,nonlinear effect weakens as the micro-crack becomes thicker.The amplitudes of sum and difference frequency are positively correlated with the length and width of the zero-thickness cohesive element in the composite laminates.Furthermore,amplitude ratio change is investigated and it can be used as an effective tool to detect inner defects in thin 3D plates.
基金supported by the National Grand Fundamental Research 973 Program of China(2004CB318109)the National High Technology Research and Development Program of China(863 Program)(2006AA01Z452).
文摘Spurious signals in direct digital frequency synthesizers (DDFSs) are partly caused by amplitude quantization and phase truncation, which affect their application to many wireless telecommunication systems. These signals are deterministic and periodic in the time domain, so they appear as line spectra in the frequency domain. Two types of spurious signals due to amplitude quantization are exactly formulated and compared in the time and frequency domains respectively. Then the frequency spectra and power levels of the spurious signals due to amplitude quantization in the absence of phase-accumulator truncation are emphatically analyzed, and the effects of the DDFS parameter variations on the spurious signals are thoroughly studied by computer simulation. And several important conclusions are derived which can provide theoretical support for parameter choice and spurious performance evaluation in the application of DDFSs.
基金Supported by the Knowledge Innovation Program of Chinese Academy of Sciences (No. KZCX-YW-12-04)the National Natural Science Foundation of China (No. 41030855)+1 种基金the National High Technology Research and Development Program of China (863 Program) (No. 2008AA09A403)the Marine Public Welfare Project of China (No. 201105032)
文摘One of the most important parameters for oceanic internal waves (IWs) is their amplitude. We have developed a method to retrieve the IW amplitude from nautical X-Band radar images based on the KdV equation for continuous stratified finite depth system. We have also tested the method of measuring the amplitude of IWs from X-Band radar backscatter image sequences acquired on June 2009 in the northeastern South China Sea. The method was applied in several radar images. Experiments show that the retrieval amplitudes are consistent with the in-situ observational amplitudes of IWs by using the towed thermistor chain and conductivity-temperature-depth (CTD) profile. The uncertainty of the method is also discussed.
基金the Major Scientific andTechnical Project of Department of Science and Technology,Inner Mongolia in 2016(Strong Earthquake Track in the Short Stage and Integration Innovation of Stereoscopic Observation Technology in Space and Ground)
文摘In order to search for the seismic wave characteristics of low frequency signals in the Alxa Left Banner region,Inner Mongolia,the low frequency signals of seismic wave data are extracted from the earthquakes of MS5. 8 in 2015 and MS5. 0 in 2016 in this area. The results show that:① Before the MS5. 8 earthquake,the seismic stations located near the epicenter in Wuhai,Dongshengmiao,and Shizuishan recorded seismic waves that showed the phenomenon of spectrum shift from high to low frequency.② The low frequency signals recorded by different stations have obvious difference.③ According to the data recorded by the station closest to the epicenter,low-frequency signals were recorded about120 hours before the earthquake and had obvious anomalies. This may reflect slow slip before the earthquake.
文摘In the present communication, the hydrodynamic model is used to investigate the amplitude modulation as well as demodulation of an electromagnetic wave of high power helicon pump wave into another helicon wave in strain dependent dielectric material incorporating carrier heating (CH) effects. The consideration of CH in modulation and demodulation is prime importance for the adding of new dimension in analysis of amplification of acoustic helicon wave. By using the dispersion relation, threshold pump electric filed and growth rate of unstable mode from the modulation and demodulation of the high power helicon wave well above from the threshold value will be discussed in the present analysis. The numerical analysis is applied to a strain dependent dielectric material, BaTiO3 at room temperature and irradiated with high power helicon wave of frequency 1.78 × 1014 Hz. This material is very sensitive to the pump intensities, therefore during studies, Gaussian shape of the helicon pump wave is considered during the propagation in stain dependent dielectric material and opto-acoustic wave in the form of Gaussian profile (ω0,κ0) is induced longitudinally along the crystallographic plane of BaTiO3. Its variation is caused by the available magnetic field (ωc), interaction length (z) and pulsed duration of interaction (τ). From the analysis of numerical results, the incorporation of CH effect can effectively modify the magnitude of modulation or demodulation of the amplitude of high power helicon laser wave through diffusion process. Not only the amplitude modulation and demodulation of the wave, the diffusion of the CH effectively modifies the growth rate of unstable mode of frequency in BaTiO3. The propagation of the threshold electric field shows the sinusoidal or complete Gaussian profile, whereas this profile is found to be completely lost in growth of unstable mode. It has also been seen that the growth rate is observed to be of the order of 108 - 1010 s-1 but from diffusion of carrier heating, and that its order is enhanced from 1010 - 1012 s-1 with the variation of the magnetized frequency from 1 to 2.5 × 1014 Hz.
文摘An accurate frequency synchronization method using the zadoff-chu (ZC) constant envelop preamble is analyzed, and a new preamble weighted by pseudo-noise sequence is used for orthogonal frequency division multiplexing (OFDM) systems. Using this method, frequency offset estimator range is greatly enlarged with no loss in accuracy. The range of the frequency estimation is ±30 of subcarrier spacing using ZC sequence as preamble. Simulations in the MATLAB for an AWGN channel show that the proposed method achieves superior performance to existing techniques in terms of frequency accuracy and range.