期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Sensor design and implementation for a downhole NMR fluid analysis laboratory 被引量:10
1
作者 Wu Baosong Xiao Lizhi +2 位作者 Li Xin Yu Huijun An Tianlin 《Petroleum Science》 SCIE CAS CSCD 2012年第1期38-45,共8页
This paper tries to build a multi-functional downhole nuclear magnetic resonance (NMR) fluid analysis laboratory that can evaluate fluid information in real time at reservoir conditions at a depth of several thousan... This paper tries to build a multi-functional downhole nuclear magnetic resonance (NMR) fluid analysis laboratory that can evaluate fluid information in real time at reservoir conditions at a depth of several thousand meters. The aim is to monitor the pollution of the formation fluids and quantitatively evaluate NMR characteristics of the fluids. It focuses on the design of the structure and parameters of a sensor with zero stray fields. Two separate coils are designed to measure NMR characteristics of flowing or static fluids. A method is proposed to use the Bloch equation, to guide the optimization of the NMR sensor. Finally, the measured results confirm that the design is reasonable. There is a homogeneous static field (perpendicular to the axial direction) in the center of the sensor, and there are no stray external fields. The novel design of pre-polarization magnet improves the signal to noise ratio, while shortening the sensor length. 展开更多
关键词 NMR fluid analysis laboratory MAGNET Bloch equation
下载PDF
Gait Analysis of a Subject with Tarsometatarsal Prosthesis
2
作者 Carlos Diaz Novo Walter Mar Haller +3 位作者 Emiliano Alvarez Ruiz Micaela González Castillo Manuel Bárbaro Cuadra Mateo Olivera García 《Journal of Biosciences and Medicines》 2023年第10期284-297,共14页
Introduction: Gait analysis of an adult man after trans-metatarsal unilateral amputation is described. Objective: Instrumental gait analysis of a subject 15 years after trans-metatarsal unilateral amputation in two fo... Introduction: Gait analysis of an adult man after trans-metatarsal unilateral amputation is described. Objective: Instrumental gait analysis of a subject 15 years after trans-metatarsal unilateral amputation in two footwear conditions: while walking barefoot and with prosthesis. Materials and Methods: In a movement analysis laboratory, locomotion studies were carried out at freely chosen walking speed by a 65-year-old subject, obtaining kinematic, kinetic and surface electromyographic data in time and space. Gait analysis was performed using instrumental technologies from a digital eco-system applying walking protocols. Results: When the patient wore the prosthesis, several positive improvements were observed in various aspects of gait. These included enhancements in the base of support, gait speed, and joint range of movements. Additionally, there was a slight improvement in the vertical ground reaction forces pattern, indicating a positive effect of the assistive technology. Furthermore, the use of the prosthesis led to a more organized pattern of muscle activity, which further supports its beneficial impact. However, it is worth noting that some challenges still persisted, particularly regarding stabilizing the body during the double support phase. Despite this difficulty, the overall findings suggest that the use of the prosthesis offers valuable improvements to the patient’s gait dynamics. Conclusions: After conducting a thorough analysis of the parameters related to the gait of a subject who underwent a trans-metatarsal unilateral amputation fifteen years ago, it was found that the use of prosthesis had a positive impact. This study demonstrated important improvements in some kinematic and kinetic parameters, including muscle activation patterns, indicating an increase in comfort and confidence while utilizing the prosthetic device. 展开更多
关键词 Tarsometatarsal Amputation PROSTHESIS GAIT Motion analysis laboratory
下载PDF
Detection and Analysis of Ebola Virus in Sierra Leone-China Friendship Biosafety Laboratory from March 11 to April 20, 2015 被引量:2
3
作者 WANG Qin ZHANG Yong +13 位作者 WANG Huan Yu DU Hai Jun NIE Kai SONG Jing Dong XIAO Kang LEI Wen Wen GUO Jian Qiang WEI He Jiang CAI Kun WANG Yan Hai WU Jiang Gerald BANGURA Idrissa Laybohr KAMARA DONG Xiao Ping 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2016年第6期443-447,共5页
Ebola virus disease reemerged in Western Africa in 2014.Chinese Center for Disease Control and Prevention dispatched the first Ebola virus(EBOV)detection team to run newly established Sierra Leone-China Friendship B... Ebola virus disease reemerged in Western Africa in 2014.Chinese Center for Disease Control and Prevention dispatched the first Ebola virus(EBOV)detection team to run newly established Sierra Leone-China Friendship Biological Safety Laboratory.The aims of study were to understand epidemiology,clinical manifestations and survival time of EBOV in patient's blood.A total of 913specimens were tested between March 11 and April20, 2015. EBOV positivity occurred in 7.37% of the blood and 0.53% in throat swabs. 展开更多
关键词 Detection and analysis of Ebola Virus in Sierra Leone-China Friendship Biosafety laboratory from March 11 to April 20 2015 EVD
下载PDF
Gait Analysis of a Subject with Total Hip Arthroplasty
4
作者 Carlos Díaz Novo Micaela González Castillo +3 位作者 Juan Bentos Dupuy Maximiliano Vespa Correa Martín Machado López Felipe Gorla Gargano 《Journal of Biosciences and Medicines》 CAS 2022年第10期135-143,共9页
Introduction: gait analysis of a subject with total hip replacement is described. Objective: instrumental gait analysis of a subject 12 years after the total hip arthroplasty. Materials and Methods: in a movement anal... Introduction: gait analysis of a subject with total hip replacement is described. Objective: instrumental gait analysis of a subject 12 years after the total hip arthroplasty. Materials and Methods: in a movement analysis laboratory, locomotion studies were carried out at freely chosen walking speed by a 64-year-old subject, obtaining kinematic, kinetic and surface electromyographic data in time and space. All measurements were assessments by applying walking protocols on a straight surface of 8 m long. Results: abnormal slight activations of semitendinosus and tibialis anterior muscles, of the left limb, were observed throughout the gait cycle, no spatiotemporal parameters far from normal values were detected. Conclusions: it was possible to obtain an exhaustive analysis of the parameters associated with the gait of a subject after 12 years of total hip arthroplasty. 展开更多
关键词 Total Hip Arthroplasty KINETICS KINEMATICS Surface Electromyography Motion analysis laboratory PATHOLOGICAL
下载PDF
Feasibility of Gas Drive in Fang-48 Fault Block Oil Reservoir 被引量:3
5
作者 Cui Lining Hou Jirui Yin Xiangwen 《Petroleum Science》 SCIE CAS CSCD 2007年第3期51-56,共6页
The Fang-48 fault block oil reservoir is an extremely low permeability reservoir, and it is difficult to produce such a reservoir by waterflooding. Laboratory analysis of reservoir oil shows that the minimum miscibili... The Fang-48 fault block oil reservoir is an extremely low permeability reservoir, and it is difficult to produce such a reservoir by waterflooding. Laboratory analysis of reservoir oil shows that the minimum miscibility pressure for CO2 drive in Fang-48 fault block oil reservoir is 29 MPa, lower than the formation fracture pressure of 34 MPa, so the displacement mechanism is miscible drive. The threshold pressure gradient for gas injection is less than that for waterflooding, and the recovery by gas drive is higher than waterflooding. Furthermore, the threshold pressure gradient for carbon dioxide injection is smaller than that for hydrocarbon gas, and the oil recovery by carbon dioxide drive is higher than that by hydrocarbon gas displacement, so carbon dioxide drive is recommended for the development of the Fang-48 fault block oil reservoir. 展开更多
关键词 Low permeability reservoir gas drive FEASIBILITY laboratory analysis numerical simulation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部