Enantioselective analytical methods in chiral drug metabolism
1
作者 洪燕君 高凌波 曾苏 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第3期177-182,共6页
The chiral nature of biological systems enables their stereoselective interaction with chiral compounds. It has been well documented that the enantiomers ofa chiral drug may show differences in drug disposition especi... The chiral nature of biological systems enables their stereoselective interaction with chiral compounds. It has been well documented that the enantiomers ofa chiral drug may show differences in drug disposition especially in metabolic behavior. As a result, it is of vital importance to separate the enantiomers of a chiral drug in metabolic studies. This paper discusses enantioselective methods (include high-performance liquid chromatography, gas chromatography, capillary electrophoresis and high-performance liquid chromatography-mass spectrometry) that applied in chiral drug metabolism, using most recent examples where possible. 展开更多
关键词 Enantioselective analytical methods Chiral drug Drug metabolism
下载PDF
Development of analytical methods for polycyclic aromatic hydrocarbons (PAHs) in airborne particulates: A review 被引量:10
2
作者 LIU Li-bin LIU Yan +3 位作者 LIN Jin-ming TANG Ning HAYAKAWA Kazuichi MAEDA Tsuneaki 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第1期1-11,共11页
In the present work, the different sample collection, pretreatment and analytical methods for polycyclic aromatic hydrocarbons (PAHs) in airborne particulates is systematacially reviewed, and the applications of the... In the present work, the different sample collection, pretreatment and analytical methods for polycyclic aromatic hydrocarbons (PAHs) in airborne particulates is systematacially reviewed, and the applications of these pretreatment and analytical methods for PAHs are compared in detail. Some comments on the future expectation are also presented. 展开更多
关键词 polycyclic aromatic hydrocarbons (PAHs) airborne particulates analytical methods REVIEW
下载PDF
Analytical methods for investigating in vivo fate of nanoliposomes:A review 被引量:5
3
作者 Chong Su Yingze Liu +1 位作者 Yang He Jingkai Gu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2018年第4期219-225,共7页
Nanoliposomes are considered to be the most successful nanoparticle drug delivery system, but their fate in vivo has not been fully understood due to lack of reliable bioanalytical methods, which seriously limits the ... Nanoliposomes are considered to be the most successful nanoparticle drug delivery system, but their fate in vivo has not been fully understood due to lack of reliable bioanalytical methods, which seriously limits the development of liposomal drugs. Hence, an overview of currently used bioanalytical methods is imperative to lay the groundwork for the need of developing a bioanalytical method for liposome measurements in vivo. Currently, major analytical methods for nanoliposomes measurement in vivo include fluorescence labeling, radiolabeling, magnetic resonance imaging(MRI), mass spectrometry and computed tomography. In this review, these bioanalytical methods are summarized, and the advantages and disadvantages of each are discussed. We provide insights into the applicability and limitations of these analytical methods in the application of nanoliposomes measurement in vivo, and highlight the recent development of instrumental analysis techniques. The review is devoted to providing a comprehensive overview of the investigation of nanoliposomes design and associated fate in vivo, promoting the development of bioanalytical techniques for nanoliposomes measurement, and understanding the pharmacokinetic behavior, effectiveness and potential toxicity of nanoliposomes in vivo. 展开更多
关键词 Liposomes analytical methods In vivo fate Liposomal drug
下载PDF
Analytical Methods for Environmental Risk Assessment of Acid Sulfate Soils: A Review 被引量:5
4
作者 C. LIN School of Environmental Science and Management, Southern Cross University, Lismore, NSW (Australia) 《Pedosphere》 SCIE CAS CSCD 2001年第4期301-310,共10页
Assessment of acid sulfate soil risk is an important step for acid sulfate soil management and its reliability depends very much on the suitability and accuracy of various analytical methods for estimating sulfide-der... Assessment of acid sulfate soil risk is an important step for acid sulfate soil management and its reliability depends very much on the suitability and accuracy of various analytical methods for estimating sulfide-derived potential acidity, actual acidity and acid-neutralizing capacity in acid sulfate soils. This paper critically reviews various analytical methods that are currently used for determination of the above parameters, as well as their implications for environmental risk assessment of acid sulfate soi1s. 展开更多
关键词 acid risk assessment acid sulfate soils analytical methods
下载PDF
Analytical methods for determination of terbinafine hydrochloride in pharmaceuticals and biological materials 被引量:2
5
作者 Basavaiah Kanakapura Vamsi Krishna Penmatsa 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第3期137-149,共13页
Terbinafine is a new powerful antifungal agent indicated for both oral and topical treatment of myco- sessince. It is highly effective in the treatment of determatomycoses. The chemical and pharmaceutical analysis of ... Terbinafine is a new powerful antifungal agent indicated for both oral and topical treatment of myco- sessince. It is highly effective in the treatment of determatomycoses. The chemical and pharmaceutical analysis of the drug requires effective analytical methods for quality control and pharmacodynamic and pharmacokinetic studies. Ever since it was introduced as an effective antifungal agent, many methods have been developed and validated for its assay in pharmaceuticals and biological materials. This article reviews the various methods reported during the last 25 years. 展开更多
关键词 Terbinafine hydrochloride analytical methods Pharmaceuticals Biological materials
下载PDF
Pioglitazone:A review of analytical methods 被引量:2
6
作者 N.Satheeshkumar S.Shantikumar R.Srinivas 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第5期295-302,共8页
Pioglitazone is an oral anti-hyperglycemic agent. It is used for the treatment of diabetes mellitus type 2. It selectively stimulates nuclear receptor peroxisome proliferator-activated receptor gamma (PPAR-gamma). I... Pioglitazone is an oral anti-hyperglycemic agent. It is used for the treatment of diabetes mellitus type 2. It selectively stimulates nuclear receptor peroxisome proliferator-activated receptor gamma (PPAR-gamma). It was the tenth-best-selling drug in the U.S. in 2008. This article examines published analytical methods reported so far in the literature for the determination of pioglitazone in biological samples and pharmaceutical formulations. They include various techniques like electrochemical methods, spectrophotometry, capillary electrophoresis, high-performance liquid chromatography, liquid chromatography-electrospray ionization-tandem mass spectrometry and high-performance thin layer chromatography. 展开更多
关键词 PIOGLITAZONE analytical methods Diabetes mellitus type 2
下载PDF
Hydrodynamic Performance of a Newly-Designed Pelagic and Demersal Trawls Using Physical Modeling and Analytical Methods for Cameroonian Industrial Fisheries
7
作者 Tcham Leopold Vanlie Maurice Kontchou +2 位作者 Nyatchouba Nsangue Bruno Thierry Abdou Njifenjou Njomoue Pandong Achille 《Open Journal of Marine Science》 2023年第3期41-65,共25页
This study proposed the newly-designed Pelagic and demersal trawls for the fishing vessels operating in Cameroonian waters in pelagic and demersal fishing grounds. The engineering performances of both trawls were inve... This study proposed the newly-designed Pelagic and demersal trawls for the fishing vessels operating in Cameroonian waters in pelagic and demersal fishing grounds. The engineering performances of both trawls were investigated using physical modelling method and analytical method based on the predicted equations. In a flume tank, a series of physical model tests based on Tauti’s law were performed to investigate the hydrodynamic and geometrical performances of both trawls and to assess the applicability of the analytical methods based on predicted equations. The results showed that in model scale, the working towing speed and door spread for the pelagic trawl were 3.5 knots and 1.85 m, respectively, and for the bottom trawl net they were 4.0 knots and 1.8 m. At that speed and door spread, the drag force, net opening height, and wing-end spread of the pelagic model trawl were 36.73 N, 0.89 m, and 0.86 m, respectively, and the swept area was 0.76 m<sup>2</sup>. Bottom trawl speed and door spread were 30.43 N, 0.38 m, and 0.45 m, respectively, and the swept area was 0.25 m<sup>2</sup>. The maximum difference between the experimental and analytical results of hydrodynamic performances was less than 56.22% and 41.45%, respectively, for pelagic and bottom trawls, the results of the geometrical performances obtained using predicted equations were close to the experimental results in the flume tank with a maximum relative error less than 12.85%. The newly developed pelagic and bottom trawls had advanced engineering performance for high catch efficiency and selectivity and could be used in commercial fishing operations in Cameroonian waters. 展开更多
关键词 Cameroonian Waters Pelagic Trawl Bottom Trawl Engineering Performances Physical Model Test analytical methods Formatting
下载PDF
Analytical methods for nano-bio interface interactions 被引量:2
8
作者 Jing Wang Waseem Akthar Quershi +2 位作者 Yiye Li Jianxun Xu Guangjun Nie 《Science China Chemistry》 SCIE EI CAS CSCD 2016年第11期1467-1478,共12页
Knowledge on the interactions between engineered nanomaterials(ENMs) and biological systems is critical both for the assessment of biological effects of ENMs and for the rational design of ENM-based products. However,... Knowledge on the interactions between engineered nanomaterials(ENMs) and biological systems is critical both for the assessment of biological effects of ENMs and for the rational design of ENM-based products. However, probing the events that occur at the nano-bio interface remains extremely challenging due to their complex and dynamic nature. So far, the understanding of mechanisms underlying nano-bio interactions has been mainly limited by the lack of proper analytical techniques with sufficient sensitivity, selectivity and resolution for characterization of nano-bio interface events. Moreover, many classic bioanalytical methods are not suitable for direct measurement of nano-bio interface interactions. These have made establishing analytical methodologies for systematic and comprehensive study of nano-bio interface one of the most focused areas in nanobiology. In this review we have discussed some representative developments regarding analytical techniques for nano-bio interface characterization, including the improvements of traditional methods and the emergence of powerful new technologies. These developments have allowed ultrasensitive, real-time analysis of interactions between ENMs and biomolecules, transformations of ENMs in biological environment, and impacts of ENMs on living systems on molecular or cellular level. 展开更多
关键词 engineered nanomaterial nano-bio interface nano-bio interaction analytical methods protein corona synchrotron radiation
原文传递
Review of analytical methods for stress and deformation analysis of buried water pipes considering pipe-soil interaction
9
作者 Yingxu Huo Sherif Mohsen Mohamed Hassan Gomaa +1 位作者 Tarek Zayed Mohamed Meguid 《Underground Space》 SCIE EI CSCD 2023年第6期205-227,共23页
Buried water pipelines are vulnerable to fail or break due to excessive loading or ground displacements.Accurate evaluation of pipe performance and serviceability relies on the proper understanding of pipe-soil intera... Buried water pipelines are vulnerable to fail or break due to excessive loading or ground displacements.Accurate evaluation of pipe performance and serviceability relies on the proper understanding of pipe-soil interactions(PSI).Analytical methods are important approaches to studying PSI.However,a systematic and thorough literature review to analyze the existing research trends,technological achievements and future research opportunities is not available.This work investigates analytical methods that analyze the stress and deformation of pipes in terms of cross-sectional,transverse and longitudinal PSI problems.First,scientometric analysis is performed to acquire relevant research works from online databases and analyze the existing data of influential authors,productive research sources and frequent key word occurrence in the fields of interest.Second,a qualitative discussion is performed in the three categories of PSI:(1)cross-sectional,including ovalization and circumferential behaviours;(2)transverse,including seismic fault crossing,weak soil zones,ground settlement and pipe uplift;and(3)longitudinal.Third,six research opportunities are discussed,including the role of friction in cross-sectional deformation,combined effects of bending and compression,choice of soil reaction models and calibration of key parameters,effect of pipe flaws,soil spatial variability and behaviours of curved pipes.This study helps beginners familiarize themselves with PSI analytical methods and provides experienced researchers with ideas for future research directions. 展开更多
关键词 PIPELINE analytical methods Pipe-soil interactions Seismic fault SETTLEMENT UPLIFT BUCKLING TUNNELLING
原文传递
Review on analytical technologies and applications in metabolomics
10
作者 XIN MENG YAN LIU +2 位作者 SHUJUN XU LIANRONG YANG RUI YIN 《BIOCELL》 SCIE 2024年第1期65-78,共14页
Over the past decade,the swift advancement of metabolomics can be credited to significant progress in technologies such as mass spectrometry,nuclear magnetic resonance,and multivariate statistics.Currently,metabolomic... Over the past decade,the swift advancement of metabolomics can be credited to significant progress in technologies such as mass spectrometry,nuclear magnetic resonance,and multivariate statistics.Currently,metabolomics garners widespread application across diverse fields including drug research and development,early disease detection,toxicology,food and nutrition science,biology,prescription,and chinmedomics,among others.Metabolomics serves as an effective characterization technique,offering insights into physiological process alterations in vivo.These changes may result from various exogenous factors like environmental conditions,stress,medications,as well as endogenous elements including genetic and protein-based influences.The potential scientific outcomes gleaned from these insights have catalyzed the formulation of innovative methods,poised to further broaden the scope of this domain.Today,metabolomics has evolved into a valuable and widely accepted instrument in the life sciences.However,comprehensive reviews focusing on the sample preparation and analytical methodologies employed in metabolomics within the life sciences are surprisingly scant.This review aims to fill that gap,providing an overview of current trends and recent advancements in metabolomics.Particular emphasis is placed on sample preparation,sophisticated analytical techniques,and their applications in life science research. 展开更多
关键词 Metabolomics Sample preparation analytical methods Application of metabolomics
下载PDF
Green analytical chemistry metrics for evaluating the greenness of analytical procedures
11
作者 Lei Yin Luyao Yu +7 位作者 Yingxia Guo Chuya Wang Yuncheng Ge Xinyue Zheng Ning Zhang jiansong You Yong Zhang Meiyun Shi 《Journal of Pharmaceutical Analysis》 CSCD 2024年第11期1542-1555,共14页
Green analytical chemistry(GAC)focuses on mitigating the adverse effects of analytical activities on human safety,human health,and environment.In addition to the 12 principles of GAC,proper GAC tools should be develop... Green analytical chemistry(GAC)focuses on mitigating the adverse effects of analytical activities on human safety,human health,and environment.In addition to the 12 principles of GAC,proper GAC tools should be developed and employed to assess the greenness of different analytical assays.The 15 widely used GAC metrics,i.e.,national environmental methods index(NEMI),advanced NEMI,assessment of green profile(AGP),chloroform-oriented toxicity estimation scale(ChlorTox Scale),Analytical Eco-Scale,Green Certificate Modified Eco-Scale,analytical method greenness score(AMGS),green analytical procedure index(GAPI),ComplexGAPI,red-green-blue(RGB)additive color model,RGB 12 algorithm,analytical greenness calculator(AGREE),AGREE preparation(AGREEprep),HEXAGON,and blue applicability grade index(BAGI),are selected as the typical tools.This article comprehensively presents and elucidates the principles,characteristics,merits,and demerits of 15 widely used GAC tools.This review is helpful for researchers to use the current GAC metrics to assess the environmental sustainability of analytical assays. 展开更多
关键词 Greenness metric Green analytical chemistry analytical methods Environmental sustainability
下载PDF
Analysis profile of the fully grouted rock bolt in jointed rock using analytical and numerical methods 被引量:5
12
作者 Ghadimi Mostafa Shahriar Kourosh Jalalifar Hossein 《International Journal of Mining Science and Technology》 SCIE EI 2014年第5期609-615,共7页
The purpose of this study was to investigate the effect of bolt profile on load transfer mechanism of fully grouted bolts in jointed rocks using analytical and numerical methods. Based on the analytical method with de... The purpose of this study was to investigate the effect of bolt profile on load transfer mechanism of fully grouted bolts in jointed rocks using analytical and numerical methods. Based on the analytical method with development of methods, a new model is presented. To validate the analytical model, five different profiles modeled by ANSYS software. The profile of rock bolts T3 and T4with load transfer capacity,respectively 180 and 195 kN in the jointed rocks was selected as the optimum profiles. Finally, the selected profiles were examined in Tabas Coal Mine. FLAC analysis indicates that patterns 6+7 with2 NO flexi bolt 4 m better than other patterns within the faulted zone. 展开更多
关键词 Fully grouted bolt Load transfer mechanism Jointed rocks analytical and numerical methods
下载PDF
Overview of the Analytical Lifecycle of Supercritical Fluid Chromatography Methods
13
作者 Bertyl Andri Amandine Dispas +1 位作者 Roland Djang’eing’a Marini Philippe Hubert 《American Journal of Analytical Chemistry》 2016年第1期75-91,共17页
In recent times, the overall interest over Supercritical Fluid Chromatography (SFC) is truly growing within various domains but especially for pharmaceutical analysis. However, in the best of our knowledge modern SFC ... In recent times, the overall interest over Supercritical Fluid Chromatography (SFC) is truly growing within various domains but especially for pharmaceutical analysis. However, in the best of our knowledge modern SFC is not yet applied for drug quality control in the daily routine framework. Among the numerous reported SFC methods, none of them could be found to fully satisfy to all steps of the analytical method lifecycle. Thereby, the present contribution aims to provide an overview of the current and past achievements related to SFC techniques, with a targeted attention to this lifecycle and its successive steps. The included discussions were therefore structured accordingly and emphasizing the analytical method lifecycle in accord with the International Conference on Harmonisation (ICH). Recent and important scientific outputs in the field of analytical SFC, as well as instrumental evolution, qualification strategies, method development methodologies and discussions on the topic of method validation are reviewed. 展开更多
关键词 Supercritical Fluid Chromatography Ultra High Performance Supercritical Fluid Chromatography analytical Method Lifecycle Quality by Design
下载PDF
Analytical Method for the Wave Diffraction of Asymmetrically Arranged Breakwaters
14
作者 ZHOU Pei-xin ZHANG Hong-sheng 《China Ocean Engineering》 SCIE EI CSCD 2024年第5期797-808,共12页
The layout forms of several breakwater structures can be generalized as asymmetrical arrangements in actual engineering.However,the problem of wave diffraction around asymmetrically arranged breakwaters has not been a... The layout forms of several breakwater structures can be generalized as asymmetrical arrangements in actual engineering.However,the problem of wave diffraction around asymmetrically arranged breakwaters has not been adequately investigated.In this study,we propose an analytical method of wave diffraction for regular waves passing through asymmetrically arranged breakwaters,and we use the Nyström method to obtain the analytical solution numerically.We compared the results of this method with those of previous analytical solutions and with numerical results to demonstrate the validity of our approach.We also provided diffraction coefficient diagrams of breakwaters with different layout forms.Moreover,we described the analytical expression for the problem of diffraction through long-wave incident breakwaters and presented an analysis of the relationship between the diffraction coefficients and the widths of breakwater gates.The analytical method presented in this study contributes to the limited literature on the theory of wave diffraction through asymmetrically arranged breakwaters. 展开更多
关键词 regular waves BREAKWATERS analytical method wave diffraction
下载PDF
Utility and Application of a Versatile Analytical Method for MMF Calculation in AC Machines
15
作者 Ze-Zheng Wu Robert Nilssen Jian-Xin Shen 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第1期22-31,共10页
A versatile analytical method(VAM) for calculating the harmonic components of the magnetomotive force(MMF) generated by diverse armature windings in AC machines has been proposed, and the versatility of this method ha... A versatile analytical method(VAM) for calculating the harmonic components of the magnetomotive force(MMF) generated by diverse armature windings in AC machines has been proposed, and the versatility of this method has been established in early literature. However, its practical applications and significance in advancing the analysis of AC machines need further elaboration. This paper aims to complement VAM by augmenting its theory, offering additional insights into its conclusions, as well as demonstrating its utility in assessing armature windings and its application of calculating torque for permanent magnet synchronous machines(PMSM). This work contributes to advancing the analysis of AC machines and underscores the potential for improved design and performance optimization. 展开更多
关键词 AC machine analytical method Harmonic analysis MMF Magnetic field Torque calculation
下载PDF
THE ANALYTICAL SOLUTIONS BASED ON THE CONCEPT OF FINITE ELEMENT METHODS
16
作者 隋允康 郭田福 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1990年第4期321-331,共11页
On the basis of the concept of finite element methods, the rigorous analytical solutions of structural response in terms of the design variables are researched in this paper. The spatial trusses are taken as an exampl... On the basis of the concept of finite element methods, the rigorous analytical solutions of structural response in terms of the design variables are researched in this paper. The spatial trusses are taken as an example for the solution of the analytical expressions of the explicit displacements which are proved mathematically; then some conclusions are reached that are useful to structural sensitivity analysis and optimization. In the third part of the paper, a generalized geometric programming method is sugguested for the optimal model with the explicit displacement. Finally, the analytical solutions of the displacements of three trusses are given as examples. 展开更多
关键词 THE analytical SOLUTIONS BASED ON THE CONCEPT OF FINITE ELEMENT methods
下载PDF
A review on global spatial distribution,sources and toxicity of perfluoroalkyl acid and prospect in the cryosphere
17
作者 LI Bowen Du Wentao +5 位作者 KANG Shichang CHEN Jizu JIANG Youyan YIN Lichen LU Changsheng LIU Hongyi 《Journal of Mountain Science》 2025年第1期167-183,共17页
Perfluoroalkyl acid analogs(PFAAs)are a class of chemically stable environmentally persistent organic pollutants(POPs)that are difficult to degrade and have a strong capacity to accumulate in the human body.PFAAs have... Perfluoroalkyl acid analogs(PFAAs)are a class of chemically stable environmentally persistent organic pollutants(POPs)that are difficult to degrade and have a strong capacity to accumulate in the human body.PFAAs have been found to be biotoxic to humans and have been detected in various environmental media,especially in the cryosphere at trace concentrations.The cryosphere,sensitively responds to climate change,plays a crucial role in the global water,carbon and energy cycles.However,researches on cryosphere PFAAs especially in Tibetan Plateau(TP)is limited.Therefore,we summarize the physicochemical properties,physiological toxicity,spatiotemporal distribution,sources,diffusion and migration pathways,as well as analysis and removal methods of PFAAs in the cryosphere regions.The results show that PFAAs pollutants are mainly produced and distributed in the more economically developed countries in Europe and the United States,as well as in East Asia,and PFAAs can be transported by atmospheric circulation and water cycle to remote regions including cryosphere regions.The current detection methods for PFAAs in cryosphere need to be further refined for increased accuracy and convenience.There is also a need to develop more effective removal methods that will reduce the environmental and human threats posed by these PFAAs.Finally,we propose key scientific questions for future research in cryosphere including PFAAs redistribution influenced by cryosphere changes,human activities,and the interaction of other spheres. 展开更多
关键词 Perfluoroalkyl acid CRYOSPHERE Physiological toxicity analytical method Removal method
下载PDF
Upgraded Analytical Protocols in Bauxite Refining Industry Using Composite Sampling Approach to Minimize Laboratory Analysis Load
18
作者 Faisal Mubarak AlDossari 《Materials Sciences and Applications》 CAS 2023年第2期94-116,共23页
The laboratories in the bauxite processing industry are always under a heavy workload of sample collection, analysis, and compilation of the results. After size reduction from grinding mills, the samples of bauxite ar... The laboratories in the bauxite processing industry are always under a heavy workload of sample collection, analysis, and compilation of the results. After size reduction from grinding mills, the samples of bauxite are collected after intervals of 3 to 4 hours. Large bauxite processing industries producing 1 million tons of pure aluminium can have three grinding mills. Thus, the total number of samples to be tested in one day reaches a figure of 18 to 24. The sample of bauxite ore coming from the grinding mill is tested for its particle size and composition. For testing the composition, the bauxite ore sample is first prepared by fusing it with X-ray flux. Then the sample is sent for X-ray fluorescence analysis. Afterwards, the crucibles are washed in ultrasonic baths to be used for the next testing. The whole procedure takes about 2 - 3 hours. With a large number of samples reaching the laboratory, the chances of error in composition analysis increase. In this study, we have used a composite sampling methodology to reduce the number of samples reaching the laboratory without compromising their validity. The results of the average composition of fifteen samples were measured against composite samples. The mean of difference was calculated. The standard deviation and paired t-test values were evaluated against predetermined critical values obtained using a two-tailed test. It was found from the results that paired test-t values were much lower than the critical values thus validating the composition attained through composite sampling. The composite sampling approach not only reduced the number of samples but also the chemicals used in the laboratory. The objective of improved analytical protocol to reduce the number of samples reaching the laboratory was successfully achieved without compromising the quality of analytical results. 展开更多
关键词 Composite Sampling analytical methods Sampling Technique Bauxite Composite Sampling Sampling Protocols Aluminum Ore Sampling Technique Sampling methods
下载PDF
Development and Validation of Proximal Chemistry Analytical Procedure in Semi-automated Equipment
19
作者 Patricia Parra Cervantes M. Tonantzin Rios Rodríguez +2 位作者 Janet Edith Santamaría Víquez Ramón Soto Vázquez Joaquin Tlatempa López 《Journal of Pharmacy and Pharmacology》 2018年第8期782-789,共8页
The proximal chemical analysis (AQP) includes 5 fundamental tests, which are: determination of crude protein, determination of crude fiber, determination of humidity, determination of ashes and determination of fa... The proximal chemical analysis (AQP) includes 5 fundamental tests, which are: determination of crude protein, determination of crude fiber, determination of humidity, determination of ashes and determination of fat. This last determination can be made in two different ways, which will depend on the type of sample being treated, as well as the amount of fat expected to be obtained in the food to be analyzed. For foods with low amounts of fat the hydrolysis technique is used, which is divided into 3 phases. All the methods before being taken to the daily practice in a laboratory of food analysis either internal control, verification or third authorized must be validated, in order to obtain consistent, robust and reliable results. In those cases in which the method that will be tested differs with the method that is reported in the literature, a comparison of both methods should be made in order to ensure that both are compatible and the results will be equally reliable. In the validation, the acceptance parameters will be established for each one of the tests that are carried out in it, while at the end of it the acceptance criteria for the general method will be established. The objective of this work was to carry out the development of analytical methodology that was validatable in order to reduce analysis time by using semi-automated equipment. In the case of semi-automated equipment, this comparison of methods is carried out, as it was the case of the analysis of fat with hydrolysis, which used a hydrolysis unit and the extraction equipment using samples of finished food for animal consumption. The results obtained in the validation using the traditional method correspond to a CV less than 2%, while the results obtained using semi-automated equipment correspond to a CV less than 2% for the case of fat determination with hydrolysis. 展开更多
关键词 VALIDATION analytical methods semiautomatic animal feed.
下载PDF
Analytical solution for evaluating deformation response of existing metro tunnel due to excavation of adjacent foundation pit 被引量:9
20
作者 QIU Ju-tao JIANG Jie +2 位作者 ZHOU Xiao-jun ZHANG Yue-feng PAN Ying-dong 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第6期1888-1900,共13页
The excavation of foundation pit generates soil deformation around existing metro tunnel with shield driving method,which may lead to the deformation of tunnel lining.It is a challenge to evaluate the deformation of s... The excavation of foundation pit generates soil deformation around existing metro tunnel with shield driving method,which may lead to the deformation of tunnel lining.It is a challenge to evaluate the deformation of shield tunnel accurately and take measures to reduce the tunnel upward displacement as much as possible for geotechnical engineers.A new simplified analytical method is proposed to predict the longitudinal deformation of existing metro tunnel due to excavation unloading of adjacent foundation pit in this paper.Firstly,the additional stress of soils under vertical axisymmetric load in layered soil is obtained by using elastic multi-layer theory.Secondly,the metro tunnel is regarded as a Timoshenko beam supported by Winkler foundation so that the shear effect of tunnels can be taken into account.The additional stress acting on the tunnel due to excavation unloading in layered soil are compared with that in homogeneous soil.Additionally,the effectiveness of the analytical solution is verified via two actual cases.Moreover,parametric analysis is conducted to investigate the responses of the metro tunnel by considering such factors as the variation of subgrade coefficient,offset distance from the excavation center to tunnel longitudinal axis as well as equivalent shear stiffness.The proposed method can be used to provide theoretical basis for similar engineering project. 展开更多
关键词 metro tunnel simplified analytical method additional stress Timoshenko beam Winkler foundation
下载PDF