An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of ...An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.展开更多
AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutiv...AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutive measurements and subsequent analysis of interferometry,TMH,and MBG were recorded by two examiners using the LacryDiag.To assess intra-and interobserver reliability,we used Cohen’s kappa for categorical variables(interferometry),or intraclass correlation coefficient for continuous variables(TMH,MBG).RESULTS:Thirty eyes of 30 examinees were included.For both observers,there was excellent intraobserver reliability for MBG(0.955 and 0.970 for observer 1 and 2,respectively).Intraobserver reliability for observer 1 was substantial for interferometry(0.799),and excellent for TMH(0.863).Reliability for observer 2 was moderate for interferometry(0.535)and fair to good for TMH(0.431).Interobserver reliability was poor for interferometry(0.074)and fair to good for TMH(0.680)and MBG(0.414).CONCLUSION:LacryDiag ocular surface analyzer in our study proves to be a reliable noninvasive tool for the evaluation of TMH and MBG.As for interferometry,poor interobserver reliability,fair to good intraobserver reliability for observer 1,and moderate for observer 2,leave room for improvement.展开更多
基于半导体的光电化学(PEC)水分解技术,利用可再生能源制氢,能够实现氢能全产业链的绿色无碳化,是极具潜力的氢能发展路径之一。氧化钨(WO_(3))作为一种可见光响应的n型半导体,是PEC水分解制氢最有前途的材料之一。然而,可见光利用率低...基于半导体的光电化学(PEC)水分解技术,利用可再生能源制氢,能够实现氢能全产业链的绿色无碳化,是极具潜力的氢能发展路径之一。氧化钨(WO_(3))作为一种可见光响应的n型半导体,是PEC水分解制氢最有前途的材料之一。然而,可见光利用率低以及光生载流子复合率高等问题严重影响着WO_(3)光电极的实际应用。将有机半导体聚多巴胺(PDA)与无机半导体WO_(3)结合,成功构筑了WO_(3)/PDA复合电极,其光电流密度在1.23 V vs.RHE偏压下达到0.67 mA/cm^(2),是单一WO_(3)光电极(0.30 mA/cm^(2)1.23 V vs.RHE)的2.23倍。研究表明,在WO_(3)/PDA复合电极中,有机组分PDA展现出了优异的可见光吸收能力,无机组分WO_(3)提供了高载流子迁移率和快速的电荷传输通道,同时WO_(3)与PDA之间形成的异质结显著提高了载流子的分离效率,从而实现了载流子的有效分离与传输,因此光电催化性能得到了显著的提升。提出了一种通过构筑有机-无机复合结构来增强光电极光电性能的新策略。展开更多
To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected...To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.展开更多
Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidime...Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidimetric assay forβ2-MG as the research object,β2-MG levels were detected by different concentration gradients ofβ2-microglobulin samples in Liedemann,Mack,and Myriad reagents of three manufacturers on two automatic biochemical analyzers,and the difference of the hook effect was comparatively analyzed.Results:Leadman reagent showed the hook effect on the Beckman AU5800 automated biochemistry analyzer,while both Maccura and Mindray reagents did not show the hook effect.After the experiments,we found the limit value of the pre-zone check of Leadman reagent,and changed the parameters of the instrument,when the limit value of the pre-zone check was reached,the instrument automatically diluted the specimen five times and then detected it again.After changing the parameters of the instrument,the correlation between the three methods of detecting samples of different concentrations was r>0.99.Conclusion:Before selecting the application of immunoturbidimetric reagents,we have to carry out the risk assessment of the hook effect and selectively set the parameters of the pre-zone check based on the highest concentration that may occur in the clinic;for the items that may have the hook effect,we have to selectively set the parameters of the pre-zone check when the ratio of average reaction rate and the immediate reaction rate is at the limit value,and the phenomenon of antigen excess may occur,the instrument will carry out automatic dilution before detection,so as to avoid the issuance of erroneous results of high-value samples due to the hook effect.展开更多
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China(No.2018YFE0310200)National Natural Science Foundation of China(Nos.11705242,11805138 and 12175156)the Fundamental Research Funds for the Central Universities in China(Nos.YJ201820 and YJ201954)。
文摘An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.
文摘AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutive measurements and subsequent analysis of interferometry,TMH,and MBG were recorded by two examiners using the LacryDiag.To assess intra-and interobserver reliability,we used Cohen’s kappa for categorical variables(interferometry),or intraclass correlation coefficient for continuous variables(TMH,MBG).RESULTS:Thirty eyes of 30 examinees were included.For both observers,there was excellent intraobserver reliability for MBG(0.955 and 0.970 for observer 1 and 2,respectively).Intraobserver reliability for observer 1 was substantial for interferometry(0.799),and excellent for TMH(0.863).Reliability for observer 2 was moderate for interferometry(0.535)and fair to good for TMH(0.431).Interobserver reliability was poor for interferometry(0.074)and fair to good for TMH(0.680)and MBG(0.414).CONCLUSION:LacryDiag ocular surface analyzer in our study proves to be a reliable noninvasive tool for the evaluation of TMH and MBG.As for interferometry,poor interobserver reliability,fair to good intraobserver reliability for observer 1,and moderate for observer 2,leave room for improvement.
文摘基于半导体的光电化学(PEC)水分解技术,利用可再生能源制氢,能够实现氢能全产业链的绿色无碳化,是极具潜力的氢能发展路径之一。氧化钨(WO_(3))作为一种可见光响应的n型半导体,是PEC水分解制氢最有前途的材料之一。然而,可见光利用率低以及光生载流子复合率高等问题严重影响着WO_(3)光电极的实际应用。将有机半导体聚多巴胺(PDA)与无机半导体WO_(3)结合,成功构筑了WO_(3)/PDA复合电极,其光电流密度在1.23 V vs.RHE偏压下达到0.67 mA/cm^(2),是单一WO_(3)光电极(0.30 mA/cm^(2)1.23 V vs.RHE)的2.23倍。研究表明,在WO_(3)/PDA复合电极中,有机组分PDA展现出了优异的可见光吸收能力,无机组分WO_(3)提供了高载流子迁移率和快速的电荷传输通道,同时WO_(3)与PDA之间形成的异质结显著提高了载流子的分离效率,从而实现了载流子的有效分离与传输,因此光电催化性能得到了显著的提升。提出了一种通过构筑有机-无机复合结构来增强光电极光电性能的新策略。
文摘To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.
基金Baoding Science and Technology Bureau(2141ZF313)。
文摘Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidimetric assay forβ2-MG as the research object,β2-MG levels were detected by different concentration gradients ofβ2-microglobulin samples in Liedemann,Mack,and Myriad reagents of three manufacturers on two automatic biochemical analyzers,and the difference of the hook effect was comparatively analyzed.Results:Leadman reagent showed the hook effect on the Beckman AU5800 automated biochemistry analyzer,while both Maccura and Mindray reagents did not show the hook effect.After the experiments,we found the limit value of the pre-zone check of Leadman reagent,and changed the parameters of the instrument,when the limit value of the pre-zone check was reached,the instrument automatically diluted the specimen five times and then detected it again.After changing the parameters of the instrument,the correlation between the three methods of detecting samples of different concentrations was r>0.99.Conclusion:Before selecting the application of immunoturbidimetric reagents,we have to carry out the risk assessment of the hook effect and selectively set the parameters of the pre-zone check based on the highest concentration that may occur in the clinic;for the items that may have the hook effect,we have to selectively set the parameters of the pre-zone check when the ratio of average reaction rate and the immediate reaction rate is at the limit value,and the phenomenon of antigen excess may occur,the instrument will carry out automatic dilution before detection,so as to avoid the issuance of erroneous results of high-value samples due to the hook effect.