期刊文献+
共找到20,208篇文章
< 1 2 250 >
每页显示 20 50 100
PTW Detector7293种剂量验证方法在调强放射治疗中的对比研究
1
作者 吴晓辉 姚祖文 +4 位作者 徐珊珊 罗桃红 胡小容 姚阳 王晓华 《医疗卫生装备》 CAS 2024年第5期56-59,共4页
目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使... 目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使用PTW Detector729二维电离室矩阵配合PTW RW3固体水与PTW Ocavius 4D旋转模体对50例患者的IMRT计划分别进行归零机架角2D剂量验证、实际机架角2D剂量验证和实际机架角3D剂量验证。将剂量评估阈值设为10%,统计3种验证方法在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种评估标准下的γ通过率。采用SPSS 22.0统计学软件进行数据分析。结果:在10%剂量评估阈值标准下,归零机架角2D剂量验证的γ通过率最高,差异有统计学意义(P<0.05);实际机架角2D剂量验证的γ通过率高于实际机架角3D剂量验证,差异有统计学意义(P<0.05)。3种验证方法的γ通过率在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种标准下逐渐升高,且在3%/2 mm标准下均超过90%,结果满足临床放射治疗要求。结论:3种验证方法的验证结果均能达到IMRT剂量验证实践指南要求,根据IMRT开展情况选择合适的验证方法,对确保治疗方案安全、有效实施具有重要意义。 展开更多
关键词 PTW detector729 二维电离室矩阵 剂量验证 γ通过率 调强放射治疗
下载PDF
Low-noise and low-power pixel sensor chip for gas pixel detectors
2
作者 Zhuo Zhou Shi-Qiang Zhou +8 位作者 Dong Wang Xiang-Ming Sun Chao-Song Gao Peng-Zhen Zhu Wei-Ping Ren Jun Liu Mu-Xian Li Chen Lian Chun-Lai Dong 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期142-152,共11页
Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm... Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm.The array is divided into 16 subarrays,with pixels of 400 rows×32 columns per subarray.Each pixel incorporates two charge sensors:a diode sensor and a Topmetal sensor.The in-pixel circuit primarily consists of a charge-sensitive amplifier for energy measurements,a discriminator with a peak-holding circuit,and a time-to-amplitude converter for time-of-arrival measurements.The pixel of Topmetal-M2 has a charge input range of~0-3 k e-,a voltage output range of~0-180 mV,and a charge-voltage conversion gain of~59.56μV∕e-.The average equivalent noise charge of Topmetal-M2,which includes the readout electronic system noise,is~43.45 e-.In the scanning mode,the time resolution of Topmetal-M2 is 1 LSB=1.25μs,and the precision is^()7.41μs.At an operating voltage of 1.5 V,Topmetal-M2 has a power consumption of~49 mW∕cm~2.In this article,we provide a comprehensive overview of the chip architecture,pixel working principles,and functional behavior of Topmetal-M2.Furthermore,we present the results of preliminary tests conducted on Topmetal-M2,namely,alpha-particle and soft X-ray tests. 展开更多
关键词 Charge collection Gas detectors Semiconductor detectors X-ray detectors
下载PDF
CVTD: A Robust Car-Mounted Video Text Detector
3
作者 Di Zhou Jianxun Zhang +2 位作者 Chao Li Yifan Guo Bowen Li 《Computers, Materials & Continua》 SCIE EI 2024年第2期1821-1842,共22页
Text perception is crucial for understanding the semantics of outdoor scenes,making it a key requirement for building intelligent systems for driver assistance or autonomous driving.Text information in car-mounted vid... Text perception is crucial for understanding the semantics of outdoor scenes,making it a key requirement for building intelligent systems for driver assistance or autonomous driving.Text information in car-mounted videos can assist drivers in making decisions.However,Car-mounted video text images pose challenges such as complex backgrounds,small fonts,and the need for real-time detection.We proposed a robust Car-mounted Video Text Detector(CVTD).It is a lightweight text detection model based on ResNet18 for feature extraction,capable of detecting text in arbitrary shapes.Our model efficiently extracted global text positions through the Coordinate Attention Threshold Activation(CATA)and enhanced the representation capability through stacking two Feature Pyramid Enhancement Fusion Modules(FPEFM),strengthening feature representation,and integrating text local features and global position information,reinforcing the representation capability of the CVTD model.The enhanced feature maps,when acted upon by Text Activation Maps(TAM),effectively distinguished text foreground from non-text regions.Additionally,we collected and annotated a dataset containing 2200 images of Car-mounted Video Text(CVT)under various road conditions for training and evaluating our model’s performance.We further tested our model on four other challenging public natural scene text detection benchmark datasets,demonstrating its strong generalization ability and real-time detection speed.This model holds potential for practical applications in real-world scenarios. 展开更多
关键词 Deep learning text detection Car-mounted video text detector intelligent driving assistance arbitrary shape text detector
下载PDF
Flexibility potential of Cs_(2)BX_(6)(B=Hf,Sn,Pt,Zr,Ti;X=I,Br,Cl)with application in photovoltaic devices and radiation detectors
4
作者 Songya Wang Changcheng Chen +11 位作者 Shaohang Shi Ziyi Zhang Yan Cai Shuli Gao Wen Chen Shuangna Guo Elyas Abduryim Chao Dong Xiaoning Guan Ying Liu Gang Liu Pengfei Lu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第8期271-287,I0006,共18页
As interest in double perovskites is growing,especially in applications like photovoltaic devices,understanding their mechanical properties is vital for device durability.Despite extensive exploration of structure and... As interest in double perovskites is growing,especially in applications like photovoltaic devices,understanding their mechanical properties is vital for device durability.Despite extensive exploration of structure and optical properties,research on mechanical aspects is limited.This article builds a vacancyordered double perovskite model,employing first-principles calculations to analyze mechanical,bonding,electronic,and optical properties.Results show Cs_(2)Hfl_(6),Cs_(2)SnBr_(6),Cs_(2)SnI_(6),and Cs_(2)PtBr_(6)have Young's moduli below 13 GPa,indicating flexibility.Geometric parameters explain flexibility variations with the changes of B and X site composition.Bonding characteristic exploration reveals the influence of B and X site electronegativity on mechanical strength.Cs_(2)SnBr_(6)and Cs_(2)PtBr_(6)are suitable for solar cells,while Cs_(2)HfI_(6)and Cs_(2)TiCl_(6)show potential for semi-transparent solar cells.Optical property calculations highlight the high light absorption coefficients of up to 3.5×10^(5) cm^(-1)for Cs_(2)HfI_(6)and Cs_(2)TiCl_(6).Solar cell simulation shows Cs_(2)PtBr_(6)achieves 22.4%of conversion effciency.Cs_(2)ZrCl_(6)holds promise for ionizing radiation detection with its 3.68 eV bandgap and high absorption coefficient.Vacancy-ordered double perovskites offer superior flexibility,providing valuable insights for designing stable and flexible devices.This understanding enhances the development of functional devices based on these perovskites,especially for applications requiring high stability and flexibility. 展开更多
关键词 Double perovskite Mechanical properties Flexible PHOTOVOLTAIC Radiation detectors
下载PDF
Design and performance evaluation of a large field-of-view dual-particle time-encoded imager based on a depth-of-interaction detector
5
作者 Dong Zhao Xu-Wen Liang +6 位作者 Ping-Kun Cai Wei Cheng Wen-Bao Jia Da-Qian Hei Qing Shan Yong-Sheng Ling Chao Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期1-14,共14页
Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and ne... Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and neutron source hotspot imaging based on a depth-of-interaction(DOI)detector.The imager primarily consists of a DOI detector system and a rotary dual-layer cylindrical coded mask.An EJ276 plastic scintillator coupled with two SiPMs was designed as the DOI detector to increase the field of view and improve the imager performance.The difference in signal time at both ends and the log of the signal amplitude ratio were used to calculate the interaction position resolution.The position resolution of the DOI detector was calibrated using a collimated Cs-137 source,and the full width at half maximum of the reconstruction position of the Gaussian fitting curve was approximately 4.4 cm.The DOI detector can be arbitrarily divided into several units to independently reconstruct the source distribution images.The unit length was optimized via Am-Be source-location experiments.A multidetector filtering method is proposed for image denoising.This method can effectively reduce image noise caused by poor DOI detector position resolution.The vertical field of view of the imager was(-55°,55°)when the detector was placed in the center of the coded mask.A DT neutron source at 20 m standoff could be located within 2400 s with an angular resolution of 3.5°. 展开更多
关键词 Time-encoded imager Depth-of-interaction detector Dual-particle imaging Hotspot imaging
下载PDF
Gas microchannel plate-pixel detector for X-ray polarimetry
6
作者 Huan-Bo Feng Hong-Bang Liu +16 位作者 Dong Wang Zi-Li Li Shu-Lin Liu Qian Liu Hang-Zhou Li Bin-Long Wang Yan-Jun Xie Zong-Wang Fan Hui Wang Ran Chen Di-Fan Yi Rui-Ting Ma Fei Xie Bo Peng Xiang-Ming Sun Jin Li En-Wei Liang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期60-73,共14页
POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polar... POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polarimeter that is sensitive to soft X-rays(2-10 keV),called low-energy polarization detector.We have developed a new soft X-ray polari-zation detector prototype based on gas microchannel plates(GMCPs)and pixel chips(Topmetal).The GMCPs have bulk resistance,which prevents charging-up effects and ensures gain stability during operation.The detector is composed of low outgassing materials and is gas-sealed using a laser welding technique,ensuring long-term stability.A modulation factor of 41.28%±0.64% is obtained for a 4.5 keV polarized X-ray beam.A residual modulation of 1.96%±0.58% at 5.9 keV is observed for the entire sensitive area. 展开更多
关键词 X-ray polarimetry Gas microchannel plate-pixel detector Gamma-ray bursts
下载PDF
Probability-Enhanced Anchor-Free Detector for Remote-Sensing Object Detection
7
作者 Chengcheng Fan Zhiruo Fang 《Computers, Materials & Continua》 SCIE EI 2024年第6期4925-4943,共19页
Anchor-free object-detection methods achieve a significant advancement in field of computer vision,particularly in the realm of real-time inferences.However,in remote sensing object detection,anchor-free methods often... Anchor-free object-detection methods achieve a significant advancement in field of computer vision,particularly in the realm of real-time inferences.However,in remote sensing object detection,anchor-free methods often lack of capability in separating the foreground and background.This paper proposes an anchor-free method named probability-enhanced anchor-free detector(ProEnDet)for remote sensing object detection.First,a weighted bidirectional feature pyramid is used for feature extraction.Second,we introduce probability enhancement to strengthen the classification of the object’s foreground and background.The detector uses the logarithm likelihood as the final score to improve the classification of the foreground and background of the object.ProEnDet is verified using the DIOR and NWPU-VHR-10 datasets.The experiment achieved mean average precisions of 61.4 and 69.0 on the DIOR dataset and NWPU-VHR-10 dataset,respectively.ProEnDet achieves a speed of 32.4 FPS on the DIOR dataset,which satisfies the real-time requirements for remote-sensing object detection. 展开更多
关键词 Object detection anchor-free detector PROBABILISTIC fully convolutional neural network remote sensing
下载PDF
Effect of multiple coulomb scattering on the beam tests of silicon pixel detectors
8
作者 Lan-Kun Li Ming-Yi Dong +2 位作者 Ze Gao Liang-Cheng-Long Jin Shu-Jun Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期200-207,共8页
In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and perfo... In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and performance evaluation.When the beam energy is low,the effect of multiple Coulomb scattering on the measured resolution of the Device Under Test(DUT)must be considered to accurately evaluate the performance of the pixel chips and detectors.This study aimed to investigate the effect of multiple Coulomb scattering on the measured resolution,particularly at low beam energies.Simulations were conducted using Allpix^(2) to study the effects of multiple Coulomb scattering under different beam energies,material budgets,and telescope layouts.The simulations also provided the minimum energy at which the effect of multiple Coulomb scattering could be ignored.Compared with the results of a five-layer detector system tested with an electron beam at DESY,the simulation results were consistent with the beam test results,confirming the reliability of the simulations. 展开更多
关键词 Silicon Pixel detectors Beam Telescope Multiple Coulomb Scattering Spatial Resolution
下载PDF
Study on the Performance of the GRANDProto300 Particle Detector Array by Simulation
9
作者 Fu-Lin Dai Quan-Bu Gou +1 位作者 Xiaoyuan Huang Yi-Qing Guo 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2024年第1期173-177,共5页
The Giant Radio Array for Neutrino Detection(GRAND)is a proposed large-scale observatory designed to detect cosmic rays,gamma-rays,and neutrinos with energies exceeding 100 Pe V.The GRANDProto300 experiment is propose... The Giant Radio Array for Neutrino Detection(GRAND)is a proposed large-scale observatory designed to detect cosmic rays,gamma-rays,and neutrinos with energies exceeding 100 Pe V.The GRANDProto300 experiment is proposed as the early stage of the GRAND project,consisting of a hybrid array of radio antennas and scintillator detectors.The latter,as a mature and traditional detector,is used to cross-check the nature of the candidate events selected from radio observations.In this study,we developed a simulation software called G4GRANDProto300,based on the Geant4 software package,to optimize the spacing of the scintillator detector array and to investigate its effective area.The analysis was conducted at various zenith angles under different detector spacings,including 300,500,600,700,and 900 m.Our results indicate that,for large zenith angles used to search for cosmic-ray in the GRAND project,the optimized effective area is with a detector spacing of 500 m.The G4GRANDProto300 software that we developed could be used to further optimize the layout of the particle detector array in future work. 展开更多
关键词 astroparticle physics instrumentation:detectors (ISM:)cosmic rays
下载PDF
Metal-Halide Perovskite Submicrometer-Thick Films for Ultra-Stable Self-Powered Direct X-Ray Detectors
10
作者 Marco Girolami Fabio Matteocci +7 位作者 Sara Pettinato Valerio Serpente Eleonora Bolli Barbara Paci Amanda Generosi Stefano Salvatori Aldo Di Carlo Daniele M.Trucchi 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第9期410-431,共22页
Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has a... Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced. 展开更多
关键词 Metal-halide perovskite thin films Direct X-ray detectors Self-powered devices Operational stability Medical linear accelerator
下载PDF
Countermeasure against blinding attack for single-photon detectors in quantum key distribution
11
作者 Lianjun Jiang Dongdong Li +12 位作者 Yuqiang Fang Meisheng Zhao Ming Liu Zhilin Xie Yukang Zhao Yanlin Tang Wei Jiang Houlin Fang Rui Ma Lei Cheng Weifeng Yang Songtao Han Shibiao Tang 《Journal of Semiconductors》 EI CAS CSCD 2024年第4期76-81,共6页
Quantum key distribution(QKD),rooted in quantum mechanics,offers information-theoretic security.However,practi-cal systems open security threats due to imperfections,notably bright-light blinding attacks targeting sin... Quantum key distribution(QKD),rooted in quantum mechanics,offers information-theoretic security.However,practi-cal systems open security threats due to imperfections,notably bright-light blinding attacks targeting single-photon detectors.Here,we propose a concise,robust defense strategy for protecting single-photon detectors in QKD systems against blinding attacks.Our strategy uses a dual approach:detecting the bias current of the avalanche photodiode(APD)to defend against con-tinuous-wave blinding attacks,and monitoring the avalanche amplitude to protect against pulsed blinding attacks.By integrat-ing these two branches,the proposed solution effectively identifies and mitigates a wide range of bright light injection attempts,significantly enhancing the resilience of QKD systems against various bright-light blinding attacks.This method forti-fies the safeguards of quantum communications and offers a crucial contribution to the field of quantum information security. 展开更多
关键词 quantum key distribution single photon detector blinding attack pulsed blinding attack COUNTERMEASURE quan-tum communication
下载PDF
High-speed performance self-powered short wave ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)
12
作者 Aleksei Almaev Alexander Tsymbalov +5 位作者 Bogdan Kushnarev Vladimir Nikolaev Alexei Pechnikov Mikhail Scheglov Andrei Chikiryaka Petr Korusenko 《Journal of Semiconductors》 EI CAS CSCD 2024年第4期56-62,共7页
High-speed solar-blind short wavelength ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)layers with Pt contacts were demonstrated and their properties were studied in detail.Theκ(ε)-Ga_(2)O_(3)layers were ... High-speed solar-blind short wavelength ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)layers with Pt contacts were demonstrated and their properties were studied in detail.Theκ(ε)-Ga_(2)O_(3)layers were deposited by the halide vapor phase epitaxy on patterned GaN templates with sapphire substrates.The spectral dependencies of the photoelectric properties of struc-tures were analyzed in the wavelength interval 200-370 nm.The maximum photo to dark current ratio,responsivity,detectiv-ity and external quantum efficiency of structures were determined as:180.86 arb.un.,3.57 A/W,1.78×10^(12) Hz^(0.5)∙cm·W^(-1) and 2193.6%,respectively,at a wavelength of 200 nm and an applied voltage of 1 V.The enhancement of the photoresponse was caused by the decrease in the Schottky barrier at the Pt/κ(ε)-Ga_(2)O_(3)interface under ultraviolet exposure.The detectors demon-strated could functionalize in self-powered mode due to built-in electric field at the Pt/κ(ε)-Ga_(2)O_(3)interface.The responsivity and external quantum efficiency of the structures at a wavelength of 254 nm and zero applied voltage were 0.9 mA/W and 0.46%,respectively.The rise and decay times in self-powered mode did not exceed 100 ms. 展开更多
关键词 κ(ε)-gallium oxide solar-blind shortwave ultraviolet radiation detectors self-powered operation mode
下载PDF
基于InVEST和Geodetector模型的合肥生境质量时空演变及影响因素分析
13
作者 智菲 周振宏 +2 位作者 赵铭 杨宗霖 高超群 《河北环境工程学院学报》 CAS 2024年第3期49-54,共6页
依据2000年、2010年和2020年3期土地利用数据,运用耦合模型探究合肥2000—2020年间生境质量时空变化特征并对影响因子进行分析。结果表明:2000—2020年合肥生境质量指数平均值分别为0.185、0.181、0.178,呈逐年下降趋势,较低质量区域向... 依据2000年、2010年和2020年3期土地利用数据,运用耦合模型探究合肥2000—2020年间生境质量时空变化特征并对影响因子进行分析。结果表明:2000—2020年合肥生境质量指数平均值分别为0.185、0.181、0.178,呈逐年下降趋势,较低质量区域向低质量区域的转移面积最大。合肥生境质量退化度在2000—2020年逐年下降,呈现出“环状增长”的空间分布特征。高退化度区域主要分布在低值区域外围,呈现非连续性扩张。区域生产总值、坡度以及高程是主要影响因子,双因子增强效应显著,年末总人口和人口密度为主导单因子。 展开更多
关键词 合肥市 InVEST模型 地理探测器 生境质量 驱动因子
下载PDF
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
14
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE High performance liquid chromatography Fluorescence detector
下载PDF
基于InVEST&GEO-detectors模型的会仙湿地生境质量变化及影响因素研究
15
作者 谢玲 陈展图 +2 位作者 蒋瑜 肖小慧 贾艳红 《广西师范大学学报(自然科学版)》 CAS 北大核心 2023年第5期180-190,共11页
喀斯特湿地是广泛分布在喀斯特地区的一种特殊的湿地类型,其生态地位举足轻重,探索喀斯特湿地生境质量变化的影响因素对喀斯特地区生态建设具有重要的意义。本文基于会仙湿地保护区2000和2020年的土地利用数据,通过InVEST模型评估会仙... 喀斯特湿地是广泛分布在喀斯特地区的一种特殊的湿地类型,其生态地位举足轻重,探索喀斯特湿地生境质量变化的影响因素对喀斯特地区生态建设具有重要的意义。本文基于会仙湿地保护区2000和2020年的土地利用数据,通过InVEST模型评估会仙湿地保护区的生境质量,利用地理探测器探测影响会仙湿地保护区生境质量变化的自然和人为因素。研究结果表明:1)研究区2000至2020年建设用地明显扩张,草地和水体显著减少;2)会仙湿地保护区生境质量总体呈现下降的趋势,生境退化度有所上升,生境质量较差的区域主要集中在研究区的北部、中部和东北部;3)地理探测器识别出会仙湿地保护区生境质量空间变化受自然和人为因子的综合作用,主导影响因子是GDP(q为0.135),其次为夜间灯光指数(DMSP)(q为0.053);交互作用探测结果表明,各因子对生境质量影响呈现出双因子增强效果。研究结果有助于揭示会仙湿地保护区生境质量的时空演变过程,可针对会仙湿地生态建设的问题提出可行的应对策略。 展开更多
关键词 生境质量 InVEST模型 地理探测器 时空变化 影响因素 会仙湿地
下载PDF
Electronics system for the cosmic X-ray polarization detector 被引量:1
16
作者 Hui Wang Dong Wang +13 位作者 Ran Chen Yan-Wei Kui Hong-Bang Liu Zong-Wang Fan Huan-Bo Feng Jin Li Jun Liu Qian Liu Shi Chen Yuan-Kang Yang Zhuo Zhou Zi-Li Li Shi-Qiang Zhou Ni Fang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第5期1-12,共12页
This study presents an electronics system for cosmic X-ray polarization detection(CXPD).The CXPD was designed as a high-sensitivity soft X-ray polarimeter with a measurement energy range of 2-10 keV carried by a CubeS... This study presents an electronics system for cosmic X-ray polarization detection(CXPD).The CXPD was designed as a high-sensitivity soft X-ray polarimeter with a measurement energy range of 2-10 keV carried by a CubeSat.A stable and functionally complete electronics system under power and space constraints is a key challenge.The complete CXPD electronics system(CXPDES)comprises hardware and firmware.CXPDES adopts a three-layer electronic board structure based on functionality and available space.Two gas pixel detectors(GPDs)were placed on the top layer board,and CXPDES provided the GPDs with voltages up to-4000 V.Each GPD signal was digitized,compressed,encoded,and stored before being transmitted to the ground.The CXPDES provided stable and high-speed communication based on a scheme that separated command and data transmission,and it supports the CXPDES in-orbit upgrade.In addition,environmental monitors,silicon photomultiplier(SiPM)triggers,power management,GPDs configuration,and mode switches were included in the overall operating logic of the CXPDES.The results obtained by testing the CXPDES showed that it satisfied all the requirements of CXPD.The CXPDES provides design experience and technological readiness for future large-area X-ray polarimetry missions. 展开更多
关键词 X-ray polarimeter ELECTRONICS CUBESAT Gas pixel detector FPGA
下载PDF
Study on the gamma rays and neutrons energy response optimization of a scintillating fiber detector for EAST with Geant4 被引量:2
17
作者 Wei-Kun Chen Li-Qun Hu +4 位作者 Guo-Qiang Zhong Rui-Jie Zhou Bing Hong Qiang Li Li Yang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第9期40-49,共10页
A new scintillating fiber detector inside magnetic shielding tube was designed and assembled for use in the next round of fusion experiments in the experimental advanced superconducting tokamak to provide D–T neutron... A new scintillating fiber detector inside magnetic shielding tube was designed and assembled for use in the next round of fusion experiments in the experimental advanced superconducting tokamak to provide D–T neutron yield with time resolution.In this study,Geant4 simulations were used to obtain the pulse height spectra for ideal signals produced when detecting neutrons and gamma rays of multiple energies.One of the main sources of interference was found to be low-energy neutrons below 10–5 MeV,which can generate numerous secondary particles in the detector components,such as the magnetic shielding tube,leading to high-amplitude output signals.To address this issue,a compact thermal neutron shield containing a 1-mm Cd layer outside the magnetic shielding tube and a 5-mm inner Pb layer was specifically designed.Adverse effects on the measurement of fast neutrons and the shielding effect on gamma rays were considered.This can suppress the height of the signals caused by thermal neutrons to a level below the height corresponding to neutrons above 4 MeV because the yield of the latter is used for detector calibration.In addition,the detector has relatively flat sensitivity curves in the fast neutron region,with the intrinsic detection efficiencies(IDEs)of approximately 40%.For gamma rays with energies that are not too high(<8 MeV),the IDEs of the detector are only approximately 20%,whereas for gamma rays below 1 MeV,the response curve cuts off earlier in the low-energy region,which is beneficial for avoiding counting saturation and signal accumulation. 展开更多
关键词 Sci-Fi detector D–T fusion neutron Thermal neutron shield Energy response GEANT4
下载PDF
CsI-bowl:an ancillary detector for exit channel selection inγ-ray spectroscopy experiments 被引量:1
18
作者 Xing-Chi Han Shuo Wang +5 位作者 Hong-Yi Wu Zhi-Huan Li Guo-Zhu Shi Ruo-Fu Chen Yue-Zhao Zhang Shou-Yu Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第9期32-39,共8页
A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors,... A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels. 展开更多
关键词 Light charged particle detector array Particle identification Charge comparison method
下载PDF
Feasibility of measuring moisture content of green sand by a low frequency multiprobe detector based on dielectric characteristics 被引量:1
19
作者 De-quan Shi Gui-li Gao +1 位作者 Ming Sun Ya-xin Huang 《China Foundry》 SCIE CAS CSCD 2023年第3期197-206,共10页
Green sand is a mixture of silica sand,bentonite,water and coal powder,and other additives.Moisture content is an important index to characterize the properties of green sand.Based on the dielectric characteristics of... Green sand is a mixture of silica sand,bentonite,water and coal powder,and other additives.Moisture content is an important index to characterize the properties of green sand.Based on the dielectric characteristics of green sand and transmission line theory,a method for rapidly measuring the moisture content of green sand by means of a low frequency multiprobe detector was proposed.A system was constructed,where six detectors with different arrangements and probes were designed.The experimental results showed that the voltage difference of transmission line increases with the increasing frequency before 29 MHz while decreases after 35 MHz.A voltage difference platform occurs in the range of 29-35 MHz,which is suitable for measuring the moisture content due to its insensitivity to frequency.The electric field intensity gradually decreases with the increase of the probe depth,and the intensity of central probe is always greater than that of the edge probe.When the distance of the probe away from the sand sample surface is 80 mm,the electric field intensity of the edge probe is found to be very weak.The optimal excitation frequency for measuring the moisture content of green sand is 29-33 MHz.The optimal detector is the one with one center probe and three edge probes,and their lengths are 80 mm and 60 mm,respectively.The distance between the center and edge probes is 25 mm,and the diameter of probes is 5 mm.Taking the voltage difference of transmission line,bentonite content,coal powder content and compactability as parameters of the input layer,and the moisture content as a parameter of the output layer,a three-layer BP artificial neural network model for predicting the moisture content of green sand was constructed according to the experimental results at 33 MHz.The prediction error of the model is not higher than 3.3% when the moisture content of green sand is within the range of 3wt.%-7wt.%. 展开更多
关键词 green sand dielectric property moisture content multiprobe detector BP artificial neural network model
下载PDF
Design of the solar X-ray detector for the Macao Science Satellite-1B 被引量:1
20
作者 YongQiang Shi LianSheng Li +5 位作者 JianWu Chen FuChang Zuo XiaoPing Zhang ZhiWu Mei Li Wang Keke Zhang 《Earth and Planetary Physics》 EI CSCD 2023年第1期125-130,共6页
The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection ... The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection unit and a hard X-ray detection unit.Both the soft X-ray detection unit and the hard X-ray detection unit include two collimators,two X-ray detectors(a silicon drift detector and a cadmium-zinc-telluride detector),and a processing circuit.Compared with similar instruments,the energy range of the SXD is wider(1–600 ke V)and the energy resolution is better(150 e V at 5.9 ke V,12%at 59.5 ke V,and 3%at 662 keV). 展开更多
关键词 Macao Science Satellite-1B(MSS-1B) solar X-ray detector solar X-ray SPECTROMETER
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部