Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
1
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault grounding protection Zero-sequence current ratio coefficient
下载PDF
An Improved Algorithm of Grounding Grids Corrosion Diagnosis Based on Total Least Square Method 被引量:3
2
作者 ZHANG Ying-jiao NIU Tao WANG Sen 《高压电器》 CAS CSCD 北大核心 2011年第5期22-29,共8页
A new model considering corrosion property for grounding grids diagnosis is proposed,which provides reference solutions of ambiguous branches.The constraint total least square method based on singular value decomposit... A new model considering corrosion property for grounding grids diagnosis is proposed,which provides reference solutions of ambiguous branches.The constraint total least square method based on singular value decomposition is adopted to improve the effectiveness of grounding grids' diagnosis algorithm.The improvement can weaken the influence of the model's error,which results from the differences between design paper and actual grid.Its influence on touch and step voltages caused by the interior resistance of conductors is taken into account.Simulation results show the validity of this approach. 展开更多
关键词 corrosion property grounding grids corrosion diagnosis AMBIGUOUS total least square touch and step voltages
下载PDF
Determination of grounding line on the Amery Ice Shelf using Sentinel-1 radar interferometry data 被引量:2
3
作者 LEI Haobo ZHOU Chunxia CHEN Yiming 《Advances in Polar Science》 2017年第3期204-213,共10页
Delineation of the grounding line(GL) is necessary for calculating the mass balance of Antarctica, but GL measurements for most of the continent remain at a relatively coarse level. We used Sentinel-1 constellation da... Delineation of the grounding line(GL) is necessary for calculating the mass balance of Antarctica, but GL measurements for most of the continent remain at a relatively coarse level. We used Sentinel-1 constellation data to map the GL of the Amery Ice Shelf(AIS) using double-differential synthetic aperture radar interferometry. The ice thickness anomaly deduced from hydrostatic equilibrium and existing Antarctic GL products is compared with our result. With this new and very accurate GL, we detected new ice rises in the north of the AIS. Our new measurement shows no major change of the AIS GL, particularly in the southernmost part. 展开更多
关键词 grounding line DDInSAR hydrostatic equilibrium Amery Ice Shelf
下载PDF
An Investigation into Substation Grounding and Its Implementation on Gaza Substation 被引量:1
4
作者 Ahmed Hammuda Hassan Nouri Mohammed Saleh Al-Ayoubi 《Energy and Power Engineering》 2011年第5期593-599,共7页
An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiven... An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiveness of the substation grid system has been performed and its results have been incorporated into the Gaza case study. Through modelling and simulating the power station in Gaza while considering some field data, an optimal substation grounding grid has been designed and has shown complete conformance to safety. It is thus considered that such a design will protect personnel in any area of the substation in addition to the installed machinery if the largest possible fault current was to traverse the earth. 展开更多
关键词 GAZA grounding Grid ground Resistance SUBSTATION STEP VOLTAGE TOUCH VOLTAGE
下载PDF
The Research on Grounding Protection for 110kV Resistance Grounding Distribution System 被引量:1
5
作者 Shan Sun Guo Zeng +2 位作者 Xiaozang He Yanping Lv Xinyi Li 《Energy and Power Engineering》 2013年第4期877-880,共4页
Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network str... Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated. 展开更多
关键词 NEUTRAL grounding System by Resistance One-phase grounding Fault ZERO SEQUENCE Voltage ZERO SEQUENCE Current PROTECTION Setting
下载PDF
Study on Decision Method of Neutral Point Grounding Mode for Medium-Voltage Distribution Network 被引量:2
6
作者 Hengyong Liu Xiaofu Xiong +3 位作者 Jinxin Ouyang Xiufen Gong Yinghua Xie Jing Li 《Journal of Power and Energy Engineering》 2014年第4期656-664,共9页
The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and e... The neutral grounding mode of medium-voltage distribution network decides the reliability, overvoltage, relay protection and electrical safety. Therefore, a comprehensive consideration of the reliability, safety and economy is particularly important for the decision of neutral grounding mode. This paper proposes a new decision method of neutral point grounding mode for mediumvoltage distribution network. The objective function is constructed for the decision according the life cycle cost. The reliability of the neutral point grounding mode is taken into account through treating the outage cost as an operating cost. The safety condition of the neutral point grounding mode is preserved as the constraint condition of decision models, so the decision method can generate the most economical and reliable scheme of neutral point grounding mode within a safe limit. The example is used to verify the feasibility and effectiveness of the decision method. 展开更多
关键词 Distribution Network NEUTRAL grounding MODE RELIABILITY DECISION Method Objective FUNCTION
下载PDF
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
7
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
下载PDF
Application of Atomic Sparse Decomposition to Feature Extraction of the Fault Signal in Small Current Grounding System 被引量:1
8
作者 Nanhua Yu Rui Li +1 位作者 Jun Yang Bei Dong 《Energy and Power Engineering》 2013年第4期603-607,共5页
Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occu... Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occurred. Based on dictionary of Gabor atoms and matching pursuit algorithm, the method extracts the atomic components iteratively from the feature signals and translated them to damped sinusoidal components. Then we can obtain the parametrical and analytical representation of atomic components. The termination condition of decomposing iteration is determined by the threshold of the initial residual energy with the purpose of extract the features more effectively. Accordingly, the proposed method can extract the starting and ending moment of disturbances precisely as well as their magnitudes, frequencies and other features. The numerical examples demonstrate its effectiveness. 展开更多
关键词 Small Current grounding System Fault Line Selection ATOMIC SPARSE Decomposition Matching PURSUIT DAMPED SINUSOIDS
下载PDF
Study on Earth Surface Potential and DC Current Distribution around DC Grounding Electrode 被引量:1
9
作者 Zhi-chao Ren Chun-yan Ye Hai-yan Wang 《Energy and Power Engineering》 2013年第4期792-796,共5页
DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researche... DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results. 展开更多
关键词 DC grounding ELECTRODE Magnetic BIASING Soil STRATIFICATION Earth Surface Potential DC Current DISTRIBUTION
下载PDF
The Research on Neutral Grounding Scheme of Fengxian 35kV and 10 kV Power Grid 被引量:1
10
作者 Siming Hua Hua Zhang +2 位作者 Feng Qian Chunjie Chen Meixia Zhang 《Energy and Power Engineering》 2013年第4期897-901,共5页
Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measur... Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current. 展开更多
关键词 NEUTRAL grounding Mode Different Frequency Injected Method Capacitive Current ARC SUPPRESSION COIL Low Resistance
下载PDF
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
11
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation grounding current detection Zero sequence voltage detection
下载PDF
Small-current grounding fault location method based on transient main resonance frequency analysis 被引量:2
12
作者 Yongjie Zhang Xiaojun Wang +2 位作者 Junjuan Li Yin Xu Guohong Wu 《Global Energy Interconnection》 2020年第4期324-334,共11页
The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we t... The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we take that the main resonant frequency and its corresponding component is related to the fault distance.Based on this,a fault location method based on double-end wavelet energy ratio at the scale corresponding to the main resonant frequency is proposed.And back propagation neural network(BPNN)is selected to fit the non-linear relationship between the wavelet energy ratio and fault distance.The performance of this proposed method has been verified in different scenarios of a simulation model in PSCAD/EMTDC. 展开更多
关键词 Small-current grounding fault location Main resonant frequency Double-end wavelet energy ratio Backpropagation neural network(BPNN)
下载PDF
Analysis of a Large Grounding System and Subsequent Field Test Validation Using the Fall of Potential Method
13
作者 Huan Huang Hualin Liu +6 位作者 Hong Luo Hao Du Yi Xing Yexu Li Farid P. Dawalibi Haijun Zhou Longhai Fu 《Energy and Power Engineering》 2013年第4期1266-1272,共7页
This paper examines various aspects of the design process and subsequent field test measurements of a large and complex substation grounding system. The study and measurements show that soil layering and lead interfer... This paper examines various aspects of the design process and subsequent field test measurements of a large and complex substation grounding system. The study and measurements show that soil layering and lead interference can have a significant impact on the appropriate test location that yields the exact substation ground impedance. Applying a specific percentage rule such as the 61.8% rule for uniform soils to obtain the true ground impedance may lead to unacceptable errors for large grounding systems. This poses significant problems when attempting to validate a design based on raw test data that are interpreted using approximate methods to evaluate substation ground impedance, and determine ground potential rise (GPR), touch and step voltages. Advanced measurement methodologies and modern software packages were used to obtain and effectively analyze fall of potential test data, compute fault current distribution, and evaluate touch and step voltages for this large substation. Fault current distribution between the grounding system and other metallic paths were computed to determine the portion of fault current discharged in the grounding system. The performance of the grounding system, including its GPR and touch and step voltages, has been accurately computed and measured, taking into account the impedance of the steel material used of the ground conductors and circulating currents within the substation grounding system. 展开更多
关键词 ground Resistance Fall-of-Potential ground Impedance Measurement ground POTENTIAL RISE ground POTENTIAL Difference Touch VOLTAGE Step VOLTAGE Steel CONDUCTORS
下载PDF
The Research of Voltage Sag and Power Frequency Overvoltage on 110kV Resistance Grounding System
14
作者 Guo Zeng Guangliang Feng +1 位作者 Yanping Lv Shan Sun 《Energy and Power Engineering》 2013年第4期873-876,共4页
This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence netwo... This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence network analysis of the -11 transformer, and concludes the scope of voltage sag and swell and the degree of power frequency overvoltage and their influencing factors in the 110 kV resistance grounding system. Accordingly this paper puts forward the resistance choosing principle: the resistance grounding coefficient must be equal to or greater than 10. So it can not only wipe out the voltage sag and voltage swell but also make sure the overvoltage is limited to electrical equipment allowing range. The method mentioned above is verified by simulation results of a 110 kV power system in ATP. 展开更多
关键词 NEUTRAL grounding System by RESISTANCE One-phase grounding FAULT Power Frequency OVERVOLTAGE
下载PDF
Effects of Transformer DC Bias and the Relationship Between UHVDC Grounding Current and Grounding Resistances 被引量:3
15
作者 JIANG Wei WU Guang-ning +3 位作者 XIAO Hua HUANG Zhen Saleh Yahya Muhammed GUAN Lan 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2530-2535,共6页
Recently years,UHVDC transmission system is paid more attention to in the field of China's power system.It takes key part in the China electrical power development stratagem.But,many problems are caused by UHVDC s... Recently years,UHVDC transmission system is paid more attention to in the field of China's power system.It takes key part in the China electrical power development stratagem.But,many problems are caused by UHVDC system,such as DC bias,corrosion of metal underground and so on.DC bias is harm to the transformers nearby UHVDC grounding polar.In this paper,the influences of DC grounding current on transformer are introduced and some suggestions of DC bias solution were provided.And,the relationship between UHVDC Grounding Current and grounding Resistance of Substation was analyzed.Firstly,two-part network circuit was used to equivalent the grounding circuit.Then,an analysis of rules was done between DC bias current and grounding resistance.Finally,the conclusion is given that DC bias current rises fast as DC grounding resistance or AC grounding resistance rises.It drops when resistance of AC transmission line or interaction resistance between DC grounding system and AC grounding system rises.Decreasing AC grounding resistance and DC grounding resistance is important to restrain DC bias current.Increasing resistance of AC transmission line such as adding resistance into transformer neutral-point grounding is a useful way to limit DC bias current. 展开更多
关键词 UHVDC 变压器 直流偏磁 接地电阻
下载PDF
Grounding Impedance Measurement of High Speed Railway Integrated Grounding System
16
作者 Zhang Yi Jianguo Wang +2 位作者 Yadong Fan Mi Zhou Li Cai 《Journal of Power and Energy Engineering》 2015年第4期194-199,共6页
The high-speed railway integrated grounding system is the basic guarantee for the safe and stable operation of the railway. It is the world’s largest long-distance horizontally elongated joint grounding system, which... The high-speed railway integrated grounding system is the basic guarantee for the safe and stable operation of the railway. It is the world’s largest long-distance horizontally elongated joint grounding system, which stretches the length of hundreds to thousands of kilometers, and its structure is not only different from power station and substation grounding system, but also different from the transmission line tower, lightning rod and other small grounding devices. There is little research information on the grounding impedance of high-speed railway integrated grounding system. This paper adopted 0.618 compensation method and reverse away method respectively, measured a section of high-speed railway integrated grounding system grounding impedance by JD16 and CA6425. Measurement results are in good agreement using those two type instrument. By using 0.618 compensation method, the measurement result will be gradually converged at 0.3 Ω with the increasing of current electrode distance, which is the real grounding impedance of integrated grounding system. By using reverse away method, the maximum measurement result difference is less than 0.024 Ω with the lead of current electrode distance increasing. The measurement results will be rapidly converged 0.25 Ω. The results showed that the reverse away method is helpful to shorten the length of current electrode wiring. The measurement error will be small when the current electrode wiring is longer. 展开更多
关键词 HIGH-SPEED RAILWAY INTEGRATED grounding System grounding IMPEDANCE
下载PDF
One-Hour Contact with the Earth’s Surface (Grounding) Improves Inflammation and Blood Flow—A Randomized, Double-Blind, Pilot Study
17
作者 Gaétan Chevalier Gregory Melvin Tiffany Barsotti 《Health》 2015年第8期1022-1059,共38页
Earthing (grounding) refers to the human body being in contact with the surface of the Earth by barefoot exposure outdoors or using special indoor systems connected to the Earth. Previous studies have showed multiple ... Earthing (grounding) refers to the human body being in contact with the surface of the Earth by barefoot exposure outdoors or using special indoor systems connected to the Earth. Previous studies have showed multiple beneficial effects as a result of such contact, including better sleep, normalization of cortisol, reduced inflammation, pain and stress, and better blood flow. To determine if Earthing for one hour improves facial blood circulation, forty middle-aged volunteers were divided into a grounded group and a sham-grounded group according to a double-blind procedure. They were asked to sit in a comfortable recliner chair equipped with a grounding mat, pillow and patches. The grounding systems were either grounded or sham-grounded via a wire to the ground port of a power outlet. An infrared imaging camera was used to measure changes in blood flow and temperature. Thermal imaging showed clearly improved circulation of fluids (including blood) throughout the torso, which in turn, translates into enhanced delivery of blood to the head and improved blood circulation in the face as well. The results of this innovative study demonstrate that even one-hour contact with the Earth appears to promote significantly autonomic nervous system control of body fluids and peripheral blood flow that may improve blood circulation in the torso and face, facial tissue repair, skin health and vitality and optimize facial appearance (face anterior view p = 0.002;face lateral views p = 0.017;full anterior torso view p = 0.002). Further study using larger comparison groups and following subjects for a longer period of time (longitudinal study) is warranted. 展开更多
关键词 EARTHING grounding Thermal Imaging THERMOGRAPHY Blood Flow
下载PDF
Grounding the Human Body during Yoga Exercise with a Grounded Yoga Mat Reduces Blood Viscosity
18
作者 Richard Brown Gaétan Chevalier 《Open Journal of Preventive Medicine》 2015年第4期159-168,共10页
Objective: Research continues to show that being connected to the earth can increase the potential of the body to scavenge free radicals. This study examined the effect of just one hour of grounding on blood viscosity... Objective: Research continues to show that being connected to the earth can increase the potential of the body to scavenge free radicals. This study examined the effect of just one hour of grounding on blood viscosity while subjects participated in gentle yoga exercises designed to initiate minor inflammation. Design: In this double blind model, twenty-eight (28) subjects met at the Bowerman Sports Medicine Clinic on the campus of the University of Oregon and were grounded to the earth via contact with a grounded yoga mat or were sham-grounded. Ten yoga exercises were repeated five times over a one-hour period. Blood was taken pre and post exercise and analyzed for blood viscosity using a scanning capillary viscometer. Results: Subjects connected to the earth significantly reduced their post exercise systolic blood viscosity (p = 0.03) and diastolic blood viscosity (p = 0.03). Conclusion: Grounding has the ability to affect exercise induced inflammation, thereby reducing blood viscosity. 展开更多
关键词 EARTHING grounding YOGA YOGA MATS Blood Viscosity
下载PDF
Pulses in ground motions identified through surface partial matching and their impact on seismic rocking consequence 被引量:1
19
作者 Tang Yuchuan Wang Jiankang Wu Gang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期35-50,共16页
In seismology and earthquake engineering,it is fundamental to identify and characterize the pulse-like features in pulse-type ground motions.To capture the pulses that dominate structural responses,this study establis... In seismology and earthquake engineering,it is fundamental to identify and characterize the pulse-like features in pulse-type ground motions.To capture the pulses that dominate structural responses,this study establishes congruence and shift relationships between response spectrum surfaces.A similarity search between spectrum surfaces,supplemented with a similarity search in time series,has been applied to characterize the pulse-like features in pulse-type ground motions.The identified pulses are tested in predicting the rocking consequences of slender rectangular blocks under the original ground motions.Generally,the prediction is promising for the majority of the ground motions where the dominant pulse is correctly identified. 展开更多
关键词 velocity pulse ground motion surface similarity ROCKING OVERTURNING
下载PDF
The Love Metaphor of Plant in Chinese and Its Cognitive Grounding 被引量:1
20
作者 韩涛 彭语心 《海外英语》 2021年第22期113-114,共2页
Based on the corpus,the metaphorical structure of Love Are Plants in Chinese includes six stages:(1)sowing/rooting/ger-minating,(2)growing,(3)flowering,(4)flower fading,(5)fruiting,and(6)withering.The stages of plant ... Based on the corpus,the metaphorical structure of Love Are Plants in Chinese includes six stages:(1)sowing/rooting/ger-minating,(2)growing,(3)flowering,(4)flower fading,(5)fruiting,and(6)withering.The stages of plant growth and the developmentstages of love basically show a one-to-one correspondence,and its cognitive grounding is the psychological similarity between thesource domain PLANTS and the target domain LOVE,which is not an objective existence,but a subjective judgment of the addresser. 展开更多
关键词 cognitive metaphor LOVE PLANTS grounding
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部