We study the approximate conserved quantity of the weakly nonholonomic mechanical-electrical system. By means of the Lagrange-Maxwell equation, the Noether equality of the weakly nonholonomic mechanical-electrical sys...We study the approximate conserved quantity of the weakly nonholonomic mechanical-electrical system. By means of the Lagrange-Maxwell equation, the Noether equality of the weakly nonholonomic mechanical-electrical system is obtained. The multiple powers-series expansion of the parameter of the generators of infinitesimal transformations and the gauge function is put into a generalized Noether identity. Using the Noether theorem, we obtain an approximate conserved quantity. An example is provided to prove the existence of the approximate conserved quantity.展开更多
In this work we slwly linear polynomial operators preserving some consecutive i-convexities and leaving in-verant the polynomtals up to a certain degree. First we study the existence of an incompatibility between the ...In this work we slwly linear polynomial operators preserving some consecutive i-convexities and leaving in-verant the polynomtals up to a certain degree. First we study the existence of an incompatibility between the conservation of cenain i-cotivexities and the invariance of a space of polynomials. Interpolation properties are obtained and a theorem by Berens and DcVore about the Bernstein's operator ts extended. Finally, from these results a genera'ized Bernstein's operator is obtained.展开更多
In this paper, quartz crystal microbalance(QCM) gas sensors coated with polyehtyleneimine(PEI)was utilized for carbon dioxide(CO2) detection. The sensing mechanism is based on the availability of reversible acid...In this paper, quartz crystal microbalance(QCM) gas sensors coated with polyehtyleneimine(PEI)was utilized for carbon dioxide(CO2) detection. The sensing mechanism is based on the availability of reversible acid-base reactions between CO2 molecules and PEI at room temperature. The experimental results revealed that the PEI/starch sensor exhibited much higher sensitivity than that of pure PEI, and showed approximate linearity over a concentration region ranging from 500 ppm to 8000 ppm. The influence of humidity had also been investigated. Furthermore, the response and recovery time deceased as the operation temperatures increased. Finally, sensitivity loss after conservation for several days and reversibility of the sensors had been discussed.展开更多
文摘We study the approximate conserved quantity of the weakly nonholonomic mechanical-electrical system. By means of the Lagrange-Maxwell equation, the Noether equality of the weakly nonholonomic mechanical-electrical system is obtained. The multiple powers-series expansion of the parameter of the generators of infinitesimal transformations and the gauge function is put into a generalized Noether identity. Using the Noether theorem, we obtain an approximate conserved quantity. An example is provided to prove the existence of the approximate conserved quantity.
基金This work was supported by Junta de Andalucia. Grupo de investigacion Matematica Aplioada. Codao 1107
文摘In this work we slwly linear polynomial operators preserving some consecutive i-convexities and leaving in-verant the polynomtals up to a certain degree. First we study the existence of an incompatibility between the conservation of cenain i-cotivexities and the invariance of a space of polynomials. Interpolation properties are obtained and a theorem by Berens and DcVore about the Bernstein's operator ts extended. Finally, from these results a genera'ized Bernstein's operator is obtained.
基金supported by the National Natural Science Foundation of China under Grant No.61176006 and No.61006036the Specialized Research Fund for the Doctoral Program of Higher Education under Grant No.20120185110012
文摘In this paper, quartz crystal microbalance(QCM) gas sensors coated with polyehtyleneimine(PEI)was utilized for carbon dioxide(CO2) detection. The sensing mechanism is based on the availability of reversible acid-base reactions between CO2 molecules and PEI at room temperature. The experimental results revealed that the PEI/starch sensor exhibited much higher sensitivity than that of pure PEI, and showed approximate linearity over a concentration region ranging from 500 ppm to 8000 ppm. The influence of humidity had also been investigated. Furthermore, the response and recovery time deceased as the operation temperatures increased. Finally, sensitivity loss after conservation for several days and reversibility of the sensors had been discussed.