期刊文献+
共找到4,552篇文章
< 1 2 228 >
每页显示 20 50 100
Estimating the Input Power of a Power Plant Using the Efficiency of the Inverter
1
作者 Toussaint Tilado Guingane Sosthène Tassembedo +3 位作者 Eric Korsaga Dominique Bonkoungou Zacharie Koalaga François Zougmore 《Smart Grid and Renewable Energy》 2024年第3期99-106,共8页
The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation... The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation systems and proposes an approach based on the efficiency formula widely documented in the literature. In the absence of input data, this method makes it possible to estimate the plant’s input power using data extracted from the site, in particular that provided by the Ministry of the Environment. The importance of this study lies in the need to accurately determine the input power in order to assess the overall performance of the energy system. 展开更多
关键词 ESTIMATION Data MISSING INPUT power EFFICIENCY inverter
下载PDF
An Algorithm for Short-Circuit Current Interval in Distribution Networks with Inverter Type Distributed Generation Based on Affine Arithmetic
2
作者 Yan Zhang Bowen Du +3 位作者 Benren Pan GuannanWang Guoqiang Xie Tong Jiang 《Energy Engineering》 EI 2024年第7期1903-1920,共18页
During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in unc... During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in uncertainties in the calculation of the short-circuit current at the time of a fault.Additionally,the impacts of such uncertainties around short-circuit currents will increase with the increase of distributed power sources.Thus,it is very important to develop a method for calculating the short-circuit current while considering the uncertainties in a distribution network.In this study,an affine arithmetic algorithm for calculating short-circuit current intervals in distribution networks with distributed power sources while considering power fluctuations is presented.The proposed algorithm includes two stages.In the first stage,normal operations are considered to establish a conservative interval affine optimization model of injection currents in distributed power sources.Constrained by the fluctuation range of distributed generation power at the moment of fault occurrence,the model can then be used to solve for the fluctuation range of injected current amplitudes in distributed power sources.The second stage is implemented after a malfunction occurs.In this stage,an affine optimization model is first established.This model is developed to characterizes the short-circuit current interval of a transmission line,and is constrained by the fluctuation range of the injected current amplitude of DG during normal operations.Finally,the range of the short-circuit current amplitudes of distribution network lines after a short-circuit fault occurs is predicted.The algorithm proposed in this article obtains an interval range containing accurate results through interval operation.Compared with traditional point value calculation methods,interval calculation methods can provide more reliable analysis and calculation results.The range of short-circuit current amplitude obtained by this algorithm is slightly larger than those obtained using the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Therefore,the proposed algorithm has good suitability and does not require iterative calculations,resulting in a significant improvement in computational speed compared to the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Furthermore,the proposed algorithm can provide more reliable analysis and calculation results,improving the safety and stability of power systems. 展开更多
关键词 Short circuit calculation inverter type distributed power supplies affine arithmetic distribution network
下载PDF
Micro-arc Oxidation Inverter Power Supply Based on the Limited Bipolar Soft-switch Control Method 被引量:2
3
作者 ZENG Min CHEN Xiaohong CAO Biao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2009年第3期390-394,共5页
In order to overcome many limitations of the conventional power supplies, such as ponderosity, big wastage, and simplex output characteristic, a dual-inverter power supply is designed to meet the different requirement... In order to overcome many limitations of the conventional power supplies, such as ponderosity, big wastage, and simplex output characteristic, a dual-inverter power supply is designed to meet the different requirements of micro-arc oxidation. The main circuit structure and principle of the dual-inverter power supply for micro-arc oxidation is described, the control system and the control adjustment method are also introduced. The dual-inverter technology is adopted in micro-arc oxidation power supply. The limited bipolar control mode is applied in the power inverter circuit for adjusting the voltage, and various voltage waveform can be obtained by controlling the chopper circuit. Meanwhile, the control accuracy and response speed are improved greatly because of the higher inverter frequency. The power supply can output direct current(DC) waveform, DC pulse waveform, symmetry alternating current(AC) waveform, asymmetry AC waveform, and so on. Besides, the parameters such as pulse width, range, frequency, duty cycle can be adjusted. The experimental result shows that the power supply has many advantages, such as stable output, wonderful waveform consistency and obvious advantage in technique, and it can meet the requirements of micro-arc oxidation process fully. 展开更多
关键词 micro-arc oxidation power supply inverter CHOPPER limited bipolar
下载PDF
Optimized design of high power plasma inverter based on bionics 被引量:3
4
作者 王振民 张芩 吴祥淼 《China Welding》 EI CAS 2011年第3期37-41,共5页
Through the inspiration of the reliability mechanism of human body, it is obvious that the bionic methods can be used as a reference for the optimized design of high power plasma inverter. On this basis, the high powe... Through the inspiration of the reliability mechanism of human body, it is obvious that the bionic methods can be used as a reference for the optimized design of high power plasma inverter. On this basis, the high power plasma inverter can be composed of several high power density intelligent power electric building blocks ( IPEBB ) , which are controlled by intelligent controller with the capability of self-management and can be regarded as the cell of the inverter. All of these IPEBB can be controllable and cooperative through distributed communication structure with digital control. This structure can be regarded as the nerve of the inverter. In each IPEBB, the advance mechanical feedback mechanism is adopted to suppress the magnetic bins, over-current protection and gate driving for the high power switches. A 75 kW Prototype constructed by IPEBBs was built to test the performance. Experimental results verify the feasibility of the proposed approach, and the bionic design methods can benefit the optimized design of high power plasma inverter. 展开更多
关键词 PLASMA plasma inverter BIONICS advance mechanical feedback power electronic building block
下载PDF
A novel arc welding inverter with unit power factor based on DSP control 被引量:3
5
作者 陈树君 曾华 +2 位作者 杜利 殷树言 陈永刚 《China Welding》 EI CAS 2006年第1期53-56,共4页
A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stag... A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stage inverter bridge of the arc welding inverter. The fore-stage adopts double closed loop proportion and integration (PI) rectifier technique and the back- stage adopts digital pulse width modulation ( PWM) technique. Simulated waves can be obtained in Matlab/Simulink and validated by experiments. Experiments of the prototype showed that the total harmonic distortion (THD) can be controlled within 10% and the power factor is approximate to 1. 展开更多
关键词 arc welding inverter power factor correction (PFC) digital signal processor (DSP) HARMONIC
下载PDF
Contribution to the Optimization of the Transient Stability of an Electric Power Transmission Network Using a Universal Power Flow Compensator Controlled by a Three-Stage Inverter 被引量:2
6
作者 Koko Koko Joseph Nneme Nneme Léandre Ndjakomo Essiane Salomé 《World Journal of Engineering and Technology》 2020年第4期675-688,共14页
The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of... The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of voltage and speed regulation but also by FACTS (Flexible AC Transmission Systems) devices, which are increasingly used in power networks. In this work, optimal control coordination between a hybrid power flow controller and a three-level inverter was used to improve the transient stability of a transmission line. The UPFC is a combination of a serial compensator (SSSC) and a parallel compensator (STATCOM) both connected to a DC-LINK DC bus. The SSSC acts as a voltage source for the network and injects a voltage that can be adjusted in phase and amplitude in addition to the network voltage;the STATCOM acts as a current source. The approach used is tested in the Matlab Simulink environment on a single machine network. Optimal controller tuning gives a better transient stability improvement by reducing the transport angle oscillations from 248.17% to 9.85%. 展开更多
关键词 FACTS UPFC Three-Stage inverter PI power Transit Transient Stability
下载PDF
Online Learning Control for Harmonics Reduction Based on Current Controlled Voltage Source Power Inverters 被引量:2
7
作者 Naresh Malla Ujjwol Tamrakar +2 位作者 Dipesh Shrestha Zhen Ni Reinaldo Tonkoski 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期447-457,共11页
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t... Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients. 展开更多
关键词 Adaptive dynamic programming(ADP) current controlled voltage source power inverter(CCVSI) online learning based controller neural networks shunt active filter(SAF) total harmonic distortion(THD)
下载PDF
Reducing the minimum output power of soft-switching inverter arc welding power supplies 被引量:1
8
作者 傅强 薛松柏 《China Welding》 EI CAS 2010年第3期45-49,共5页
The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topolo... The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topology of soft-switching inverter arc welding power supplies. However, the output power still remains a certain value when the duty-cycle of leading arm decreases to zero. The working-mode of soft-switching inverter and the waveforms of major parameters with the condition of duty-cycle of leading arm being zero are studied in this paper. U-1 characteristic experiments prove that the minimum output power of soft-switching circuit, which depends on the charged voltage of capacitors in parallel with leading arm, can be decreased by reducing the duty-cycle of lagging arm. By switching working-modes between half-bridge and full-bridge, the output power can swing from zero to the power rating. 展开更多
关键词 SOFT-SWITCHING inverter arc welding power supplies minimum output power
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
9
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
Research on the Transient Power Characteristics of the Inverter for Yun-Guang UHVDC 被引量:1
10
作者 Chengjun Xia Haiwen Lan +1 位作者 Kun Men Guokai Liang 《Journal of Power and Energy Engineering》 2014年第9期176-181,共6页
During the transient period of large-disturbance of the received power grid, the power features of the inverter are of great important for the security and stability of the system. The research before is defective in ... During the transient period of large-disturbance of the received power grid, the power features of the inverter are of great important for the security and stability of the system. The research before is defective in that the constant control mode assumption and the rough HVDC simulation model. The paper establishes the PSCAD/EMTDC model for Yun-Guang EHVDC system, and analysis the transient real power and the reactive power of the inverter. With the analysis of logic for control mode, the author also introduces the physical processes of the peak of the reactive power. At last, the paper puts forward several strategies for suppressing the peak of the dynamic reactive power and real power recovery acceleration. 展开更多
关键词 UHVDC inverter TRANSIENT power FEATURES
下载PDF
Flexible Power Regulation and Limitation of Voltage Source Inverters under Unbalanced Grid Faults 被引量:2
11
作者 Peng Cheng Kongyuan Li +2 位作者 Chao Wu Jing Ma Limin Jia 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第2期153-161,共9页
This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci... This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests. 展开更多
关键词 Flexible power regulation power limiter Voltage source inverter Unbalanced faults
下载PDF
Control of mutiple Power Inverters for More Electronics Power Systems:A Review 被引量:4
12
作者 Xiaoqiang Guo Weijian Chen 《CES Transactions on Electrical Machines and Systems》 2018年第3期255-263,共9页
With the development and utilization of renewable energy,the scaling of microgrid composed of distributed generation systems and energy storing devices,e.g,photovoltaic(PV),wind power,micro gas turbine,fuel cell,are b... With the development and utilization of renewable energy,the scaling of microgrid composed of distributed generation systems and energy storing devices,e.g,photovoltaic(PV),wind power,micro gas turbine,fuel cell,are becoming much lager.Research on control of multi-inverter parallel is the focus as the key technique,which can improve the reliability of microgrids.The inverters in the microgrid operate in parallel,which not only facilitates the expansion of the microgrid but also improves the reliability of the operation of the microgrid system in off-grid mode.The key to the parallel operation of the inverter is to achieve even distribution of the load current.In this paper,a comprehensive review on the control strategies of parallel-operated inverters is presented.Also,the detailed analysis,comparison,and discussion on the existing parallel control strategies are investigated. 展开更多
关键词 Parallel inverters MICROGRID distributed power system
下载PDF
Impact of Latest Power Devices for PV Inverters
13
作者 T Fujihira MIEEE A Otsuki +3 位作者 Y Takahashi MIEEJ T Ide M Kawano N Eguchi SMIEEJ 《电力电子技术》 CSCD 北大核心 2013年第3期8-10,共3页
Excellent electrical properties and the impact of latest power devices for improving the efficiency of photovohaic(PV) inverters are presented.Power modules using SiC-MOSFET and SBD exhibit the possibility to realiz... Excellent electrical properties and the impact of latest power devices for improving the efficiency of photovohaic(PV) inverters are presented.Power modules using SiC-MOSFET and SBD exhibit the possibility to realize PV inverters with peak efficiency beyond 99%.Si-IGBT modules using reverse-blocking(RB)-IGBT have enabled to massproduce PV inverters with peak efficiency of 98.4%.Si superjunction(SJ)-MOSFET and discrete IGBT have enabled to improve the efficiency of small power PV inverters by 0.5 point. 展开更多
关键词 power DEVICE SUPERJUNCTION PHOTOVOLTAIC inverter efficiency
下载PDF
Inverter power supply system for high-power twin-wire pulsed GMAW
14
作者 Wu Kaiyuan He Zuwei Liang Zhuoyong 《China Welding》 EI CAS 2016年第2期69-75,共7页
A type of novel inverter power supply system for high-power twin-wire pulsed gas metal arc welding (GMAW) is presented mainly for dealing with the disadvantages of the conventional power supply for twin-wire pulsed ... A type of novel inverter power supply system for high-power twin-wire pulsed gas metal arc welding (GMAW) is presented mainly for dealing with the disadvantages of the conventional power supply for twin-wire pulsed GMA W of which the output power is generally difficult to increase due to limitations of the power of semiconductors and the power density of magnetic devices. In the power supplies for the master and slave arcs, the digital signal processor (DSP) TMS320F28335 is used to form the DSP- based synergic control system for parallel high-power pulsed GMA W, which achieves high-power output of two parallel inverters controlled by a single DSP ; master-slave communication is achieved by using e controller area network (eCAN)module of DSP, thas realizing anti-phase pulse output of high-power twin-wire pulsed GMA W and reducing the interference between twin arcs. The experiment results demonstrate that the designed inverter power supply system for high-power twin-wire pulsed GMAW can bring about high-power efficiency of welding, stable welding process and proper formation of welds. 展开更多
关键词 twin-wire pulsed GMAW HIGH-power parallel inverter power supply synergic control
下载PDF
Controlling the output power of soft switching arc welding inverter by two-stage continuous PWM method
15
作者 傅强 赵善麒 范新南 《China Welding》 EI CAS 2016年第1期64-70,共7页
The full bridge zero voltage zero current switching ( FB-ZVZCS ) , which could adjust the output power by keeping the duty ratio of lagging leg constant and changing the duty ratio of leading leg, was a common circu... The full bridge zero voltage zero current switching ( FB-ZVZCS ) , which could adjust the output power by keeping the duty ratio of lagging leg constant and changing the duty ratio of leading leg, was a common circuit of soft switching arc welding inverter power source. However, when the duty ratio of leading leg was reduced to zero, the output power stayed the constant value instead of becoming zero. The working status and waveforms of some major parameters were studied in this paper while the duty ratio of leading leg was zero. It was concluded that the minimum output power of soft switching inverter was related to the charging voltage of paraUel capacitors, and the output power also could be reduced by reducing the duty ratio of lagging leg. A novel two-stage continuous PWM control method that could switch working-mode between full bridge and half bridge was put forward in this paper. This kind of control method could further reduce the output power of soft switching inverter in order to meet the requirement of low heat input of sheet metal welding. 展开更多
关键词 soft switching inverter arc welding power source minimum output power two stage continuous PWM control
下载PDF
Design and Evaluation of Solar Inverter for Different Power Factor Loads
16
作者 Mohammad Ahmad B. H. Khan 《Energy and Power Engineering》 2012年第5期324-329,共6页
This paper analyzes and compares the performance of a new inverter topology with two types of input sources: 1) Solar PV source and 2) Ideal dc source (battery). The simulation is done in SIMULINK/MATLAB Software. It ... This paper analyzes and compares the performance of a new inverter topology with two types of input sources: 1) Solar PV source and 2) Ideal dc source (battery). The simulation is done in SIMULINK/MATLAB Software. It is shown that when the solar panel is connected, spikes are obtained in output voltage waveforms. These spikes are eliminated by inserting a capacitor. The capacitor is chosen for a particular power factor which is optimum with respect to cost, size and power quality. Total Harmonic Distortion, Active Power, Reactive Power, RMS Voltage and RMS Current are measured for different load power factor. Finally these results are compared with those obtained using battery with same input voltage magnitude. This Paper shows that for Solar Panel Circuit, THD, P and Q are less for 0.8 and above power factor, however below 0.8 PF, the THD, active and reactive power transfer are more. This means that the performance of Solar Panel in the proposed circuit topology is seen to be better as compared to the same circuit with battery within a range of power factor. 展开更多
关键词 H-BRIDGE inverter Level Module (LM) power Quality power Factor Total Harmonic DISTORTION (THD)
下载PDF
Data Logging and Control of a Remote Inverter Using LoRa and Power Line Communication
17
作者 K. A. Terashmila Lasagani Tariq Iqbal George K. Mann 《Energy and Power Engineering》 2018年第8期351-365,共15页
For decades, the power system was highly centralized. With the growing integration of distributed generations into the system, there is a necessity for bi-directional communication methods to monitor and control the r... For decades, the power system was highly centralized. With the growing integration of distributed generations into the system, there is a necessity for bi-directional communication methods to monitor and control the remote assets. The primary objective of this paper is to develop a communication link for monitoring and controlling a grid-connected inverter in a remote location. Furthermore, the paper presents developments that have been incorporated to improve the communication link. The literature survey indicates that LoRa is superior compared to other technologies, but has some security and reliability issues. This paper also presents an encryption algorithm to improve the security of the LoRa link. Local data storage added to the system before transmitting data increases the system reliability. A display at the transmission end is added to improve the user-friendliness of the communication link. A Powerline Communication link is parallelly added to the LoRa link to improve the reliability. Finally, tests are conducted with an actual inverter and the results are presented. The tests show that the developed communication link has improved security and reliability, while its open nature makes it highly scalable and adaptable for employment in other smart grid applications. 展开更多
关键词 LoRa Application Supervisory CONTROL and Data ACQUISITION System inverter REMOTE CONTROL power LINE COMMUNICATION
下载PDF
Efficient Choice of a Multilevel Inverter for Integration on a Hybrid Wind-Solar Power Station
18
作者 Tajeddine Khalili Abdelhadi Raihani +2 位作者 Hassan Ouajji Omar Bouattane Fouad Amri 《Journal of Power and Energy Engineering》 2015年第9期44-58,共15页
DC/AC converters are very important components that have to be chosen efficiently for each type of power station. In this article, we present in details, a comparison between three different architectures of multileve... DC/AC converters are very important components that have to be chosen efficiently for each type of power station. In this article, we present in details, a comparison between three different architectures of multilevel inverters, the flying capacitor multilevel inverter (FCMLI), the diode clamped multilevel inverter (DCMLI), and the cascaded H-bridge multilevel inverter (CHMLI). Thus the comparison is focused on the output voltage quality, the complexity of the power circuits, the cost of implementation, and the influence on a power bank inside the renewable power station. We also investigate trough simulation the efficient number of levels and suitable characteristics for the CHMLI that showed the most promising performance. The study uses Matlab Simulink platform as a tool of simulation, and aim to choose the most qualified inverter, for a potential insertion on a hybrid renewable energy platform (wind-solar). In all the simulations we use the same PWM control type (SPWM). 展开更多
关键词 MULTILEVEL inverterS FCMLI DCMLI CHMLI HYBRID power Station SPWM power BANK
下载PDF
Comparison between SiC- and Si-Based Inverters for Photovoltaic Power Generation Systems
19
作者 Yuji Ando Yasuhiro Shirahata +6 位作者 Takeo Oku Taisuke Matsumoto Yuya Ohishi Masashi Yasuda Akio Shimono Yoshikazu Takeda Mikio Murozono 《Journal of Power and Energy Engineering》 2017年第1期30-40,共11页
100-W class power storage systems were developed, which comprised spherical Si solar cells, a maximum power point tracking charge control-ler, a lithium-ion battery, and one of two different types of direct current (D... 100-W class power storage systems were developed, which comprised spherical Si solar cells, a maximum power point tracking charge control-ler, a lithium-ion battery, and one of two different types of direct current (DC)-alter- nating current (AC) converters. One inverter used SiC met-al-oxide-semicon-ductor field-effect transistors (MOSFETs) as switching devices while the other used Si MOSFETs. In these 100-W class inverters, the ON resistance was considered to have little influence on the efficiency. Nevertheless, the SiC-based inverter exhibited an approximately 3% higher DC-AC conversion efficiency than the Si-based inverter. Power loss analysis indicated that the higher efficiency resulted predominantly from lower switching and reverse recovery losses in the SiC MOSFETs compared with in the Si MOSFETs. 展开更多
关键词 Silicon CARBIDE Solar Cell inverter PHOTOVOLTAIC Device MAXIMUM power Point Tracking LITHIUM-ION Battery
下载PDF
A type of inverter power supply based on harmonic elimination PWM control
20
作者 张开如 邢呈呈 刘相楠 《Journal of Measurement Science and Instrumentation》 CAS 2013年第1期68-73,共6页
In order to output sine wave with small degree of distortion and improve stability,a type of inverter power supply is designed based on harmonic elimination pulse-width modulation(PWM)control.The rectifier and filter ... In order to output sine wave with small degree of distortion and improve stability,a type of inverter power supply is designed based on harmonic elimination pulse-width modulation(PWM)control.The rectifier and filter are added to input circuit of the inverter.Single-phrase full-bridge inverter performs the function of converting direct current into alternating current(DC/AC).In the control circuit,single chip micyoco(SCM)AT89C2051 is used for main control chip to accomplish the hardware design of the control system.A given value of output frequency of the inverter is input in the way of coding.According to the output frequency code which is read,SCM AT89C2051 defined harmonic elimination PWM control data which will be selected.Through internal timing control,the switches are switched under this provision of PWM control data.Then the driving signals of the switches in the inverter are output from I/O of SCM AT89C2051 to realize harmonic elimination PWM control.The results show that adding Newton homotopic algorithm of harmonic elimination PWM control to corresponding software of the control system can make the quality of output voltage of the inverter higher and it will have broad application prospects. 展开更多
关键词 inverter power supply pulse-width modulation(PWM) harmonic elimination PWM control Newton homotopic continuation method
下载PDF
上一页 1 2 228 下一页 到第
使用帮助 返回顶部