期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
1
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation Grounding current detection Zero sequence voltage detection
下载PDF
Intermittent Arc Fault Detection Based on Machine Learning in Resonant Grounding Distribution Systems
2
作者 Ye Tian Mou-Fa Guo Duan-Yu Chen 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第2期599-611,共13页
In resonant grounding systems,most single-phaseto-ground faults evolve from IAFs(Intermittent Arc Faults).Earlier detection of IAFs can facilitate fault avoidance.This work proposes a novel method based on machine lea... In resonant grounding systems,most single-phaseto-ground faults evolve from IAFs(Intermittent Arc Faults).Earlier detection of IAFs can facilitate fault avoidance.This work proposes a novel method based on machine learning for detecting IAFs in three steps.First,the feature of zero-sequence current is automatically extracted and selected by a newlydesigned FINET(“For IAFs,Neuron Elaboration Net”),instead of traditional feature selection based on time-frequency decomposition.Moreover,data of the zero-sequence current divided by different time windows are successively input into the trained FINET.A proposed PSF(principal-subordinate factor)analyses the results obtained from FINET to improve anti-interference in the mentioned IAF detection algorithm.Experiments using PSCAD/EMTDC software simulation data show the proposed method is feasible and highly adaptable.In addition,the detection result of on-site recorded data demonstrates the effectiveness of the proposed method in practical resonant grounding systems. 展开更多
关键词 Resonant grounding distribution systems intermittent arc faults(IAFs)detection “For IAFs Neuron Elaboration Net”(FINET) principal-subordinate factor(PSF)
原文传递
A fast arc fault detection method for AC solid state power controllers in MEA 被引量:5
3
作者 Weilin LI Kun HE +2 位作者 Wenjie LIU Xiaobin ZHANG Yanjun DONG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2018年第5期1119-1129,共11页
Arc fault detection is desperately required in Solid State Power Controllers(SSPC) in addition to their fundamental functions because arcs will provoke growing harm and threat to aircraft safety. Experimental study ... Arc fault detection is desperately required in Solid State Power Controllers(SSPC) in addition to their fundamental functions because arcs will provoke growing harm and threat to aircraft safety. Experimental study has been done to obtain the faulted current data. In order to improve the detection speed and accuracy, two fast arc fault detection methods have been proposed in this paper with the analysis of only half cycle data. Both Fast Fourier Transform(FFT) and Wavelet Packets Decomposition(WPD) have been adopted to distinguish arc fault currents from normal operation currents. Analysis results show that Alternating Current(AC) arcs can be effectively and accurately detected with the proposed half cycle data based methods. Moreover,experimental verification results have also been provided. 展开更多
关键词 Arc fault detection Experimental verification Half cycle data analysis More electric aircraft Solid state power controller
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部