期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
An active coronagraph using a liquid crystal array for exoplanet imaging:principle and testing 被引量:1
1
作者 Xi Zhang De-Qing Ren +1 位作者 Yong-Tian Zhu Jiang-Pei Dou 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2012年第5期591-600,共10页
High-contrast imaging coronagraphs, used for the detection of exoplanets, have always adopted passive coronagraph optical components. It is therefore impossible to actively optimize the coronagraphs to achieve their b... High-contrast imaging coronagraphs, used for the detection of exoplanets, have always adopted passive coronagraph optical components. It is therefore impossible to actively optimize the coronagraphs to achieve their best performance. To solve this problem, we propose a novel high-contrast imaging coronagraph which combines a liquid crystal array (LCA) for active pupil apodization and a deformable mirror (DM) for phase correction. The LCA we use is an amplitude-only spatial light mod- ulator. The LCA is well calibrated and compensates for its amplitude non-uniformity and nonlinear intensity responsivity. We measured the imaging contrasts of the coron- agraph system with the LCA only and without the DM deployed. Imaging contrasts of 10-4 and 10-5 can be reached at an inner working angular distance of 2.5 and 5A/D, respectively. A simulation shows that the phase errors on the coronagraph pupil limit the contrast performance. The contrast could be further improved if a DM is deployed to correct the phase errors induced by the LCA and coronagraph optics. 展开更多
关键词 instrumentation: coronagraph liquid crystal array - techniques high-contrast imaging exoplanet detection
下载PDF
Depth extraction method with high accuracy in integral imaging based on moving array lenslet technique
2
作者 王尧尧 张娟 +3 位作者 赵雪微 宋丽培 张勃 赵星 《Optoelectronics Letters》 EI 2018年第2期148-151,共4页
In order to improve depth extraction accuracy, a method using moving array lenslet technique(MALT) in pickup stage is proposed, which can decrease the depth interval caused by pixelation. In this method, the lenslet a... In order to improve depth extraction accuracy, a method using moving array lenslet technique(MALT) in pickup stage is proposed, which can decrease the depth interval caused by pixelation. In this method, the lenslet array is moved along the horizontal and vertical directions simultaneously for N times in a pitch to get N sets of elemental images. Computational integral imaging reconstruction method for MALT is taken to obtain the slice images of the 3 D scene, and the sum modulus(SMD) blur metric is taken on these slice images to achieve the depth information of the 3 D scene. Simulation and optical experiments are carried out to verify the feasibility of this method. 展开更多
关键词 Depth extraction method with high accuracy in integral imaging based on moving array lenslet technique
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部