In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wa...In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises.展开更多
The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures...The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures is an important factor that ensures stability of buildings subjected to dynamic loads from earthquakes, vehicles, and machineries. However, structural engineers still lack knowledge on the proper connection and detailed joints o fiBS structure construction. Therefore, this study proposes a special precast concrete wall-to-wall connection system for dynamic loads that resists multidirectional imposed loads and reduces vibration effects (PI2014701723). This system is designed to connect two adjacent precast wall panels by using two steel U-shaped channels (i.e., male and female joints). During casting, each joint is adapted for incorporation into a respective wall panel after considering the following conditions: one side of the steel channel opens into the thickness face of the panel; a U-shaped rubber is implemented between the two channels to dissipate the vibration effect; and bolts and nuts are used to create an extension between the two U-shaped male and female steel channels. The developed finite element model of the precast wall is subjected to cyclic loads to evaluate the performance of the proposed connection during an imposed dynamic load. Connection performance is then compared with conventional connections based on the energy dissipation, stress, deformation, and concrete damage in the plastic range. The proposed precast connection is capable of exceeding the energy absorption of precast walls subjected to dynamic load, thereby improving its resistance behavior in all principal directions.展开更多
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera...Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall.展开更多
结合钢筋混凝土结构和钢结构的优势,设计一种型钢-螺栓-后浇混凝土装配式剪力墙型钢混合连接。基于ABAQUS有限元软件建立混合连接的剪力墙模型,探究低周往复荷载作用下该混合连接预制剪力墙的受力性能,主要分析模型的破坏形态、受力机...结合钢筋混凝土结构和钢结构的优势,设计一种型钢-螺栓-后浇混凝土装配式剪力墙型钢混合连接。基于ABAQUS有限元软件建立混合连接的剪力墙模型,探究低周往复荷载作用下该混合连接预制剪力墙的受力性能,主要分析模型的破坏形态、受力机制、变形曲线、特征承载力等,并扩展分析了材料强度、轴压比、连接件数量、型钢截面高度等参数对模型受力性能影响。结果表明:装配式剪力墙破坏形态为压弯破坏,破坏时钢连接件仍保持完整,符合“强连接,弱墙肢”的基本设计理念;装配式剪力墙具有较好的承载力、延性和刚度;轴压比对结构承载力影响显著,型钢混合连接间距的增大能有效提升剪力墙延性。建立了型钢混合连接抗剪需求承载力计算模型和公式,并与国内外规范计算值对比分析,公式计算值和BS EN 1992欧洲规范计算值分别与模拟值的误差在15%和20%以内,均可用于型钢混合连接剪力墙竖缝受剪承载力设计参考。展开更多
在装配整体式剪力墙结构中,由于套筒灌浆连接的质量具有一定的随机性,势必影响结构的竖向连接性能和结构抗震性能。根据不同缺陷程度的套筒灌浆拉拔试验,建立了一套等效套筒灌浆缺陷连接承载力模型,并基于某实际工程结构,建立了装配整...在装配整体式剪力墙结构中,由于套筒灌浆连接的质量具有一定的随机性,势必影响结构的竖向连接性能和结构抗震性能。根据不同缺陷程度的套筒灌浆拉拔试验,建立了一套等效套筒灌浆缺陷连接承载力模型,并基于某实际工程结构,建立了装配整体式剪力墙结构有限元模型。通过考虑灌浆缺陷的随机性,赋予连接接头相应缺陷程度的力学连接性能,来反映套筒灌浆中可能存在的缺陷。通过非线性有限元分析并结合概率密度演化方法(probability density evolution method,PDEM)进行了结构随机非线性反应分析和可靠度评估。结果表明:在动力作用下,结构非线性与随机性具有明显的耦合效应;缺陷的随机性会随着时间的推移,逐渐放大对结构响应的影响;在不同的安全域内,结构的整体可靠度将存在较大的差异。展开更多
文摘In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises.
基金financial support from the Housing Research Center of UPMNAEIM Company
文摘The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures is an important factor that ensures stability of buildings subjected to dynamic loads from earthquakes, vehicles, and machineries. However, structural engineers still lack knowledge on the proper connection and detailed joints o fiBS structure construction. Therefore, this study proposes a special precast concrete wall-to-wall connection system for dynamic loads that resists multidirectional imposed loads and reduces vibration effects (PI2014701723). This system is designed to connect two adjacent precast wall panels by using two steel U-shaped channels (i.e., male and female joints). During casting, each joint is adapted for incorporation into a respective wall panel after considering the following conditions: one side of the steel channel opens into the thickness face of the panel; a U-shaped rubber is implemented between the two channels to dissipate the vibration effect; and bolts and nuts are used to create an extension between the two U-shaped male and female steel channels. The developed finite element model of the precast wall is subjected to cyclic loads to evaluate the performance of the proposed connection during an imposed dynamic load. Connection performance is then compared with conventional connections based on the energy dissipation, stress, deformation, and concrete damage in the plastic range. The proposed precast connection is capable of exceeding the energy absorption of precast walls subjected to dynamic load, thereby improving its resistance behavior in all principal directions.
文摘Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall.
文摘结合钢筋混凝土结构和钢结构的优势,设计一种型钢-螺栓-后浇混凝土装配式剪力墙型钢混合连接。基于ABAQUS有限元软件建立混合连接的剪力墙模型,探究低周往复荷载作用下该混合连接预制剪力墙的受力性能,主要分析模型的破坏形态、受力机制、变形曲线、特征承载力等,并扩展分析了材料强度、轴压比、连接件数量、型钢截面高度等参数对模型受力性能影响。结果表明:装配式剪力墙破坏形态为压弯破坏,破坏时钢连接件仍保持完整,符合“强连接,弱墙肢”的基本设计理念;装配式剪力墙具有较好的承载力、延性和刚度;轴压比对结构承载力影响显著,型钢混合连接间距的增大能有效提升剪力墙延性。建立了型钢混合连接抗剪需求承载力计算模型和公式,并与国内外规范计算值对比分析,公式计算值和BS EN 1992欧洲规范计算值分别与模拟值的误差在15%和20%以内,均可用于型钢混合连接剪力墙竖缝受剪承载力设计参考。
文摘在装配整体式剪力墙结构中,由于套筒灌浆连接的质量具有一定的随机性,势必影响结构的竖向连接性能和结构抗震性能。根据不同缺陷程度的套筒灌浆拉拔试验,建立了一套等效套筒灌浆缺陷连接承载力模型,并基于某实际工程结构,建立了装配整体式剪力墙结构有限元模型。通过考虑灌浆缺陷的随机性,赋予连接接头相应缺陷程度的力学连接性能,来反映套筒灌浆中可能存在的缺陷。通过非线性有限元分析并结合概率密度演化方法(probability density evolution method,PDEM)进行了结构随机非线性反应分析和可靠度评估。结果表明:在动力作用下,结构非线性与随机性具有明显的耦合效应;缺陷的随机性会随着时间的推移,逐渐放大对结构响应的影响;在不同的安全域内,结构的整体可靠度将存在较大的差异。