A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentra...A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentration in a microcolumn containing a chelating resin (Chelite Che with iminodiacetic acid groups) and determination by flame atomic absorption spectrometry. For the determination of the dissolved labile nickel fraction, microcolumns packed with the chelating resin were loaded in-situ with the sample without sample pH modification, and once in the laboratory were inserted in the flow injection device where nickel elution-detection was carried out. The performance of the chelating resin was investigated in order to elucidate its behavior in the presence of dissolved nickel species. The results obtained reveal that the resin, at the experimental employed conditions, retained only dissolved free nickel ions and nickel bound to weak complexes (labile fraction). The figures of merit for determinations in both nickel fractions are given and the obtained values are discussed. The speciation scheme is applied to the analysis of nickel in river and seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Ni are mainly in the dissolved labile fraction in river water, while in seawater samples analyzed was mainly present in the organic fraction.展开更多
As a component of near-field scanning optical microscope (NSOM), optical fiber probe is an important factor influncing the equipment resolution. Electroless nickel plating is introduced to metallize the optical fibe...As a component of near-field scanning optical microscope (NSOM), optical fiber probe is an important factor influncing the equipment resolution. Electroless nickel plating is introduced to metallize the optical fiber probe. The optical fibers are etched by 40% HF with Turner etching method. Through pretreatment, the optical fiber probe is coated with Ni-P film by electroless plating in a constant temperature water tank. Atomic absorption spectrometry (AAS), scanning electron microscopy (SEM), and energy dispersive X-ray spectrometry (EDXS) are carried out to characterize the deposition on fiber probe. We have reproducibly fabricated two kinds of fiber probes with a Ni-P film: aperture probe and apertureless probe. In addition, reductive particle transportation on the surface of fiber probe is proposed to explain the cause of these probes.展开更多
以吡咯烷二硫代氨基甲酸铵(APDC)氧化物作为共沉淀剂,建立了无载体离子有机共沉淀分离、石墨炉原子吸收光谱法测定海水中铜、铅、铬、镍的方法。考察了海水样品pH、共沉淀剂APDC和氧化剂H_2O_2的用量、陈化时间等因素对共沉淀分离效果...以吡咯烷二硫代氨基甲酸铵(APDC)氧化物作为共沉淀剂,建立了无载体离子有机共沉淀分离、石墨炉原子吸收光谱法测定海水中铜、铅、铬、镍的方法。考察了海水样品pH、共沉淀剂APDC和氧化剂H_2O_2的用量、陈化时间等因素对共沉淀分离效果的影响,优化了实验条件。结果证明,在p H4~5的海水样品中,加入4 m L 30 g/L APDC,1 m L H_2O_2,静置60 min,待测元素能与海水基体很好的分离。铜和铬含量在0~20μg/L范围内呈良好的线性关系,线性相关系数R>0.999;镍含量在0~30μg/L,铅含量在0~40μg/L范围内呈良好的线性关系,线性相关系数R>0.998;检出限分别为0.31,0.30,0.20,0.25μg/L,方法精密度好,加标回收率为88.8%~101.4%。方法可用于海水样品中铅、铜、镍、铬的常规检测。展开更多
文摘A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentration in a microcolumn containing a chelating resin (Chelite Che with iminodiacetic acid groups) and determination by flame atomic absorption spectrometry. For the determination of the dissolved labile nickel fraction, microcolumns packed with the chelating resin were loaded in-situ with the sample without sample pH modification, and once in the laboratory were inserted in the flow injection device where nickel elution-detection was carried out. The performance of the chelating resin was investigated in order to elucidate its behavior in the presence of dissolved nickel species. The results obtained reveal that the resin, at the experimental employed conditions, retained only dissolved free nickel ions and nickel bound to weak complexes (labile fraction). The figures of merit for determinations in both nickel fractions are given and the obtained values are discussed. The speciation scheme is applied to the analysis of nickel in river and seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Ni are mainly in the dissolved labile fraction in river water, while in seawater samples analyzed was mainly present in the organic fraction.
基金supported by the National "973" Program of China (No.2009CB930604)the Natural Science Foundation of Guangdong Province,China (No.8151064101000111)
文摘As a component of near-field scanning optical microscope (NSOM), optical fiber probe is an important factor influncing the equipment resolution. Electroless nickel plating is introduced to metallize the optical fiber probe. The optical fibers are etched by 40% HF with Turner etching method. Through pretreatment, the optical fiber probe is coated with Ni-P film by electroless plating in a constant temperature water tank. Atomic absorption spectrometry (AAS), scanning electron microscopy (SEM), and energy dispersive X-ray spectrometry (EDXS) are carried out to characterize the deposition on fiber probe. We have reproducibly fabricated two kinds of fiber probes with a Ni-P film: aperture probe and apertureless probe. In addition, reductive particle transportation on the surface of fiber probe is proposed to explain the cause of these probes.
文摘以吡咯烷二硫代氨基甲酸铵(APDC)氧化物作为共沉淀剂,建立了无载体离子有机共沉淀分离、石墨炉原子吸收光谱法测定海水中铜、铅、铬、镍的方法。考察了海水样品pH、共沉淀剂APDC和氧化剂H_2O_2的用量、陈化时间等因素对共沉淀分离效果的影响,优化了实验条件。结果证明,在p H4~5的海水样品中,加入4 m L 30 g/L APDC,1 m L H_2O_2,静置60 min,待测元素能与海水基体很好的分离。铜和铬含量在0~20μg/L范围内呈良好的线性关系,线性相关系数R>0.999;镍含量在0~30μg/L,铅含量在0~40μg/L范围内呈良好的线性关系,线性相关系数R>0.998;检出限分别为0.31,0.30,0.20,0.25μg/L,方法精密度好,加标回收率为88.8%~101.4%。方法可用于海水样品中铅、铜、镍、铬的常规检测。