Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer ...Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer cover electrode atomic emission spectrometry, and thedetermination conditions were studied systematically. The results show that the concentrations ofelements, which are beneficial to human health, are higher, and the elements harmful to peoplehealth such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy werealso discussed.展开更多
Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG ...Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG laser pulse. The ultra-short pulse serves as an igniter of the gas jet, and the subsequent ns-laser pulse significantly enhances the atomic emission. Analysis shows that the contributions to the enhancement effect are made mainly by the bremsstrahlung radiation and cascade ionization.展开更多
The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensa...The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensated by internal reference element. It is also showed that the stability of plasma caused by perhydrol matrix was effectively improved. The replicate experiment and recovery experiment revealed perfect precision and accuracy. Results got by two methods were just the same.展开更多
An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0....An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0.5mol/L)to a small residue of which Ga was then removed by extraction with 1 ml isopropyl ether.The concentrated impurities were determined by AES procedure.The recoveries for the ele- ments at the range of 0.02~0.2 μg are 95~103%;the relative standard deviations for determined impurities overa rangeofn.10^(-7)~n·10^(-8)% are 4.3~12%;the detection limit of most elements can reach n·10^(-7)~ n·10^(-8)% level with the exception of Hg and Pt.This method has been successfully used to analyze many sam- ples sent by factories and institutes.展开更多
The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon wa...The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon was 0. 047μg/mL.The method was applied to the analysis for tap water and results were satisfactory.展开更多
In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the res...In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the resonance lines of most nonmetals lie in the vacuum ultraviolet spectral region and the ionic lines of these elements are difficult to be used because the ionization potentials of the elements are very high. And furthermore only He plasma can efficiently excit those ionic resonance lines. The practical application of HeICP-AES to determining the nonmetals is also difficult because its operating and perchace costs are very high. In contrast to HeICPAES, the costs of He microwave induced plasma (MIP)-AES are relatively low, HeMIP has a high excitation capability which can excite ionic lines of various nonmetals and the nonmetals can be determined by HeMIP-AES with a high sensitivity.展开更多
Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma syst...Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma systems. Gehlausen et al. determined aqueous fluorine by coupling flow injection analysis (FIA) with HeMIP展开更多
The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol in...The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol into the MIP. The desolvation system consisted of a condenser associated with a concentrated H2SO4 absorption cell. Various experimental conditions and interferences from easily ionised elements (EIEs) were also studied and some practical samples were analyzed.展开更多
The determination of the elements of groups ⅢA and ⅣA by means of microwave plasma torch atomic emission spectrometry(MPT AES) was studied systematically. Sample solutions were introduced into the plasma with a pn...The determination of the elements of groups ⅢA and ⅣA by means of microwave plasma torch atomic emission spectrometry(MPT AES) was studied systematically. Sample solutions were introduced into the plasma with a pneumatic nebulizer in continuous sampling mode and flow injection (FI) mode. The emission characteristics of these elements were investigated in details, and the basic data obtained are very important to the development of MPT AES. The analytical performances were examined. For most elements, the detection limits obtained by this method were principally the same as those obtained by inductively coupled plasma atomic emission spectrometry (ICP AES).展开更多
A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and...A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit.展开更多
The aim of the work was the assessment of capability for the change control in the structure of a compact material of pelletized heatproof nickel alloy grade EP741NP using the atomic emission method. The proposed meth...The aim of the work was the assessment of capability for the change control in the structure of a compact material of pelletized heatproof nickel alloy grade EP741NP using the atomic emission method. The proposed method of evaluation is based on the statistical significance of the analytical response differences during atomic emission spectroscopy of solid specimens taken from one sample before and after heat treatment using the instruments AtomComp 81 and ARL 4460 with a high-voltage spark excitation. For calculations, the ratio of the line intensity of the analyzed element to the line intensity of the main sample component (in our case Ni<sub>2254</sub>) was used. The difference confidence estimation was made by the averages comparison method in a variance analysis. The study results are presented on the effect of material structure on analytical response during atomic emission spectroscopy of solid specimens. It was proved that the samples before and after heat treatment give statistically differing results while analyzed.展开更多
Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based...Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.展开更多
The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inducti...The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inductively coupled plasma atomic emission spectroscopy, and the analytical procedures were carefully controlled and validated. In general, the results show that the mean levels of K, Ca, Mg, Fe and Cu in brown rice for 789 accessions of rice landraces was distinctly lower than that of improved cultivars. They further demonstrate that Ca plays an important role in the differentiation of subspecies indica-japonica, especially to enhance adaptation of cold stress, and that five mineral elements in brown rice enhance the eurytopicity from landrace to improved cultivar. Hierarchical cluster analysis, using average linkage from SPSS software based on eight mineral elements in brown rice, showed that Yunnan rice could be grouped into rice landrace and improved cultivar, with the rice landrace being further clustered into five subgroups, and that, interestingly, purple rice does not cluster with either of the groups. Our present data confirm that indica is the closest relative of late rice and white rice, and that they constitute rice landraces together, whereas japonica is the closest relatives of non-nuda, early-mid and glutinous rice. It is further shown that japonica, non-nuda, early-mid, glutinous, white and red rice might be more primitive than indica, nuda, late, non-glutinous and purple rice, respectively.展开更多
A novel method for the cation analysis was investigated. The analysis is based on the sparking of the salts of metals in a microwave oven after placing in a graphite cell. The graphite cell absorbs microwaves and prod...A novel method for the cation analysis was investigated. The analysis is based on the sparking of the salts of metals in a microwave oven after placing in a graphite cell. The graphite cell absorbs microwaves and produces high temperature which converts the salt into light emitting species. The colour of light was found to dependent on the nature of cation, however, the intensity of the emitted light was found to be depending upon the form and shape of the graphite assembly in addition to the concentration of the salt. This communication presents explanation for all these observations and for the systematic and quantitative analysis using microwave spark emission technique.展开更多
An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the me...An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the mercury vapor generated by the HG was transmitted to the SAGD through the miniature hollow tungsten tube for excitation and detected by a miniaturized spectrograph.A thorough parametric evaluation of the HG and SAGD system was performed,including the type and concentration of ca rrier acid,He flow rate,concentrations of NaBH4,discha rge current and discharge gap.Under optimal operating conditions,the detection limit for Hg^(2+) achieved 0.03 μg/L,with a relative standard deviation of 1.1% at the Hg^(2+) concentration of 5 μg/L.Moreover,the correlation coefficient of the calibration curve was 0.9996 in the range between 0.1 and 10 μg/L.The accuracy and practicability of HG-SAGD-AES were verified by measuring GBW09101 b(human hair),GBW10029(fish),soil and rice samples.The results showed good agreement with the certified values and values from direct mercury analyzer(DMA).展开更多
Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or...Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or not. Subjecting the water sample to 0.3 Tesla magnetic field for 14 hours led to instantaneous effects on the examined water properties, where a reduction in the values of pH (7%) and interfacial tension (0.2%) was observed, whereas an increase (8%) in water electrical conductivity was recorded. Similar behaviours with slight changes in trend were observed after storing the samples for six days, which indicates a creation of permanent effects. Other experiments were conducted to explore the impact of magnetizing water sample containing inorganic mercury prior to detection by emission spectroscopy. Samples were prepared with different mercury concentrations and derivatized by using tin chloride (SnCI2). The generated mercury vapour species were transported with aid of carrier gas into a dielectric barrier discharge plasma atomizer, in which the mercury signal at 253.65 nm was recorded. The results have shown 3.5%-7.5% increase in the signal intensities recorded for the magnetized samples, mostly attributed to a reduction in the sample surface tension and other reasons, which facilitates analyte derivatization.展开更多
The analysis of trace elements in human tooth for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostic and forensic science. This study investiga...The analysis of trace elements in human tooth for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostic and forensic science. This study investigated concentrations of essential and toxic elements (Zn, Cu, Pb, Ni, Co and Cd) using flame atomic absorption spectroscopy (FAAS) and (Na and K) flame atomic emission spectroscopy (FAES) in human tooth obtained from Misan province, Iraq. The influence of smoking habits and born children on the levels of trace elements in additional to dental erosion by some beverages in the tooth samples were investigated. The overall of mean concentrations of (Zn 185.2 ppm, Cu 36.11 ppm, Pb 18.63 ppm, Ni 13.44 ppm, Co 3.45 ppm, and Cd 0.58 ppm, Na 11.683 ppm and K 115.27 ppm), (Zn 178.243 ppm, Cu 35.877 ppm, Pb 15.64 ppm, Ni 12.89 ppm, Co 3.421 ppm, Cd 0.455 ppm, Na 11,558.04 ppm and K 114.04 ppm) in smokers and non-smokers tooth groups respectively, (Zn 81.12 ppm, Cu 24.37 ppm, Pb 11.18 ppm, Ni 13.68 ppm, Co 3.32 ppm, Cd 0.44 ppm, Na 8227 ppm and K 76.42 ppm), (Zn 80.58 ppm, Cu 24.30 ppm, Pb 10.86 ppm, Ni 12.74 ppm, Co 2.71 ppm, Cd 0.23 ppm, Na 8165 ppm and K 72.80 ppm) in mothers and wives tooth groups respectively. However the w/w% loss of tooth immersed in following order of beverages (green tea, black tea, cinnamon, hibiscus, vinegar and citrus aurantifolia (9.09, 9.68, 12.36, 15.01, 16.77 and 17.38), (8.19, 8.25, 9.76, 13.37, 14.02 and 15.33) in smokers and non-smokers groups respectively, (11.25, 11.47, 13.30, 15.75, 19.58, and 20.91), (8.31, 7.96, 11.39, 13.49, 17.40, and 17.67) in mothers and wives groups respectively. However, there is a statistically significant variance found Zn (t<sub>cal</sub> 5.029, t<sub>tab</sub> 2.131), Pb (t<sub>cal</sub> 4.8538, t<sub>tab</sub> 2.131), Ni (t<sub>ca</sub><sub>l</sub> 5.243, t<sub>tab</sub> 2.131), Cd (t<sub>cal</sub> 3.9062, t<sub>tab</sub> 2.131) and Na (t<sub>cal</sub> 3.0832, t<sub>tab</sub> 2.131) between smokers and non-smokers tooth groups. However, the Co (t<sub>cal</sub> 2.7403, t<sub>tab</sub> 2.131) also shows statistically significant variance between mothers and wives groups. There is no statistically significant variance in w/w% loss after immersed the tooth in some beverages but in general it was higher in smokers than non-smokers and in mothers higher than wives.展开更多
Quantum aspects of the Joule-Lenz law for the transmission of energy allowed us to calculate the time rate of energy transitions between the quantum states of the hydrogen atom in a fully non-probabilistic way. The ca...Quantum aspects of the Joule-Lenz law for the transmission of energy allowed us to calculate the time rate of energy transitions between the quantum states of the hydrogen atom in a fully non-probabilistic way. The calculation has been extended to all transitions between p and s states having main quantum numbers not exceeding 6. An evident similarity between the intensity pattern obtained from the Joule-Lenz law and the corresponding quantum-mechanical transition pro-babilities has been shown.展开更多
文摘Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer cover electrode atomic emission spectrometry, and thedetermination conditions were studied systematically. The results show that the concentrations ofelements, which are beneficial to human health, are higher, and the elements harmful to peoplehealth such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy werealso discussed.
基金Project supported by the National Natural Science Foundation of China (Grant No 10474081).
文摘Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG laser pulse. The ultra-short pulse serves as an igniter of the gas jet, and the subsequent ns-laser pulse significantly enhances the atomic emission. Analysis shows that the contributions to the enhancement effect are made mainly by the bremsstrahlung radiation and cascade ionization.
文摘The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensated by internal reference element. It is also showed that the stability of plasma caused by perhydrol matrix was effectively improved. The replicate experiment and recovery experiment revealed perfect precision and accuracy. Results got by two methods were just the same.
文摘An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0.5mol/L)to a small residue of which Ga was then removed by extraction with 1 ml isopropyl ether.The concentrated impurities were determined by AES procedure.The recoveries for the ele- ments at the range of 0.02~0.2 μg are 95~103%;the relative standard deviations for determined impurities overa rangeofn.10^(-7)~n·10^(-8)% are 4.3~12%;the detection limit of most elements can reach n·10^(-7)~ n·10^(-8)% level with the exception of Hg and Pt.This method has been successfully used to analyze many sam- ples sent by factories and institutes.
文摘The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon was 0. 047μg/mL.The method was applied to the analysis for tap water and results were satisfactory.
文摘In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the resonance lines of most nonmetals lie in the vacuum ultraviolet spectral region and the ionic lines of these elements are difficult to be used because the ionization potentials of the elements are very high. And furthermore only He plasma can efficiently excit those ionic resonance lines. The practical application of HeICP-AES to determining the nonmetals is also difficult because its operating and perchace costs are very high. In contrast to HeICPAES, the costs of He microwave induced plasma (MIP)-AES are relatively low, HeMIP has a high excitation capability which can excite ionic lines of various nonmetals and the nonmetals can be determined by HeMIP-AES with a high sensitivity.
基金Supported by the National Natural Science Founddation of China
文摘Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma systems. Gehlausen et al. determined aqueous fluorine by coupling flow injection analysis (FIA) with HeMIP
基金Supported by the Natinoal Natural Science Foundation of China.
文摘The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol into the MIP. The desolvation system consisted of a condenser associated with a concentrated H2SO4 absorption cell. Various experimental conditions and interferences from easily ionised elements (EIEs) were also studied and some practical samples were analyzed.
文摘The determination of the elements of groups ⅢA and ⅣA by means of microwave plasma torch atomic emission spectrometry(MPT AES) was studied systematically. Sample solutions were introduced into the plasma with a pneumatic nebulizer in continuous sampling mode and flow injection (FI) mode. The emission characteristics of these elements were investigated in details, and the basic data obtained are very important to the development of MPT AES. The analytical performances were examined. For most elements, the detection limits obtained by this method were principally the same as those obtained by inductively coupled plasma atomic emission spectrometry (ICP AES).
文摘A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit.
文摘The aim of the work was the assessment of capability for the change control in the structure of a compact material of pelletized heatproof nickel alloy grade EP741NP using the atomic emission method. The proposed method of evaluation is based on the statistical significance of the analytical response differences during atomic emission spectroscopy of solid specimens taken from one sample before and after heat treatment using the instruments AtomComp 81 and ARL 4460 with a high-voltage spark excitation. For calculations, the ratio of the line intensity of the analyzed element to the line intensity of the main sample component (in our case Ni<sub>2254</sub>) was used. The difference confidence estimation was made by the averages comparison method in a variance analysis. The study results are presented on the effect of material structure on analytical response during atomic emission spectroscopy of solid specimens. It was proved that the samples before and after heat treatment give statistically differing results while analyzed.
基金funded by the Ministry of Education,Science and Technological Development of the Republic of Serbia(Nos.451-03-68/2022-14/200017 and 451-03-68/2022-14/200146)the financial support of the State Committee on Science and Technology of the Republic of Belarusthe Belarusian Republican Foundation for Fundamental Research(No.F20SRBG-001)。
文摘Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.
基金Supported by the National Natural Science Foundation of China (30660092)the Cooperation Program between Province and Zhejiang University from Yunnan Provincial Scientific and Technology Department (2006YX12)the Yunnan Introduction and Foster Talent Program (2005PY01-14)
文摘The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inductively coupled plasma atomic emission spectroscopy, and the analytical procedures were carefully controlled and validated. In general, the results show that the mean levels of K, Ca, Mg, Fe and Cu in brown rice for 789 accessions of rice landraces was distinctly lower than that of improved cultivars. They further demonstrate that Ca plays an important role in the differentiation of subspecies indica-japonica, especially to enhance adaptation of cold stress, and that five mineral elements in brown rice enhance the eurytopicity from landrace to improved cultivar. Hierarchical cluster analysis, using average linkage from SPSS software based on eight mineral elements in brown rice, showed that Yunnan rice could be grouped into rice landrace and improved cultivar, with the rice landrace being further clustered into five subgroups, and that, interestingly, purple rice does not cluster with either of the groups. Our present data confirm that indica is the closest relative of late rice and white rice, and that they constitute rice landraces together, whereas japonica is the closest relatives of non-nuda, early-mid and glutinous rice. It is further shown that japonica, non-nuda, early-mid, glutinous, white and red rice might be more primitive than indica, nuda, late, non-glutinous and purple rice, respectively.
文摘A novel method for the cation analysis was investigated. The analysis is based on the sparking of the salts of metals in a microwave oven after placing in a graphite cell. The graphite cell absorbs microwaves and produces high temperature which converts the salt into light emitting species. The colour of light was found to dependent on the nature of cation, however, the intensity of the emitted light was found to be depending upon the form and shape of the graphite assembly in addition to the concentration of the salt. This communication presents explanation for all these observations and for the systematic and quantitative analysis using microwave spark emission technique.
基金the Instrument Development Project of the Chinese Academy of Sciences(No.YZ201539)the National Natural Science Foundation of China(No.21175145)Shanghai Technical Platform for Testing on Inorganic Materials(No.19DZ2290700)。
文摘An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the mercury vapor generated by the HG was transmitted to the SAGD through the miniature hollow tungsten tube for excitation and detected by a miniaturized spectrograph.A thorough parametric evaluation of the HG and SAGD system was performed,including the type and concentration of ca rrier acid,He flow rate,concentrations of NaBH4,discha rge current and discharge gap.Under optimal operating conditions,the detection limit for Hg^(2+) achieved 0.03 μg/L,with a relative standard deviation of 1.1% at the Hg^(2+) concentration of 5 μg/L.Moreover,the correlation coefficient of the calibration curve was 0.9996 in the range between 0.1 and 10 μg/L.The accuracy and practicability of HG-SAGD-AES were verified by measuring GBW09101 b(human hair),GBW10029(fish),soil and rice samples.The results showed good agreement with the certified values and values from direct mercury analyzer(DMA).
文摘Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or not. Subjecting the water sample to 0.3 Tesla magnetic field for 14 hours led to instantaneous effects on the examined water properties, where a reduction in the values of pH (7%) and interfacial tension (0.2%) was observed, whereas an increase (8%) in water electrical conductivity was recorded. Similar behaviours with slight changes in trend were observed after storing the samples for six days, which indicates a creation of permanent effects. Other experiments were conducted to explore the impact of magnetizing water sample containing inorganic mercury prior to detection by emission spectroscopy. Samples were prepared with different mercury concentrations and derivatized by using tin chloride (SnCI2). The generated mercury vapour species were transported with aid of carrier gas into a dielectric barrier discharge plasma atomizer, in which the mercury signal at 253.65 nm was recorded. The results have shown 3.5%-7.5% increase in the signal intensities recorded for the magnetized samples, mostly attributed to a reduction in the sample surface tension and other reasons, which facilitates analyte derivatization.
文摘The analysis of trace elements in human tooth for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostic and forensic science. This study investigated concentrations of essential and toxic elements (Zn, Cu, Pb, Ni, Co and Cd) using flame atomic absorption spectroscopy (FAAS) and (Na and K) flame atomic emission spectroscopy (FAES) in human tooth obtained from Misan province, Iraq. The influence of smoking habits and born children on the levels of trace elements in additional to dental erosion by some beverages in the tooth samples were investigated. The overall of mean concentrations of (Zn 185.2 ppm, Cu 36.11 ppm, Pb 18.63 ppm, Ni 13.44 ppm, Co 3.45 ppm, and Cd 0.58 ppm, Na 11.683 ppm and K 115.27 ppm), (Zn 178.243 ppm, Cu 35.877 ppm, Pb 15.64 ppm, Ni 12.89 ppm, Co 3.421 ppm, Cd 0.455 ppm, Na 11,558.04 ppm and K 114.04 ppm) in smokers and non-smokers tooth groups respectively, (Zn 81.12 ppm, Cu 24.37 ppm, Pb 11.18 ppm, Ni 13.68 ppm, Co 3.32 ppm, Cd 0.44 ppm, Na 8227 ppm and K 76.42 ppm), (Zn 80.58 ppm, Cu 24.30 ppm, Pb 10.86 ppm, Ni 12.74 ppm, Co 2.71 ppm, Cd 0.23 ppm, Na 8165 ppm and K 72.80 ppm) in mothers and wives tooth groups respectively. However the w/w% loss of tooth immersed in following order of beverages (green tea, black tea, cinnamon, hibiscus, vinegar and citrus aurantifolia (9.09, 9.68, 12.36, 15.01, 16.77 and 17.38), (8.19, 8.25, 9.76, 13.37, 14.02 and 15.33) in smokers and non-smokers groups respectively, (11.25, 11.47, 13.30, 15.75, 19.58, and 20.91), (8.31, 7.96, 11.39, 13.49, 17.40, and 17.67) in mothers and wives groups respectively. However, there is a statistically significant variance found Zn (t<sub>cal</sub> 5.029, t<sub>tab</sub> 2.131), Pb (t<sub>cal</sub> 4.8538, t<sub>tab</sub> 2.131), Ni (t<sub>ca</sub><sub>l</sub> 5.243, t<sub>tab</sub> 2.131), Cd (t<sub>cal</sub> 3.9062, t<sub>tab</sub> 2.131) and Na (t<sub>cal</sub> 3.0832, t<sub>tab</sub> 2.131) between smokers and non-smokers tooth groups. However, the Co (t<sub>cal</sub> 2.7403, t<sub>tab</sub> 2.131) also shows statistically significant variance between mothers and wives groups. There is no statistically significant variance in w/w% loss after immersed the tooth in some beverages but in general it was higher in smokers than non-smokers and in mothers higher than wives.
文摘Quantum aspects of the Joule-Lenz law for the transmission of energy allowed us to calculate the time rate of energy transitions between the quantum states of the hydrogen atom in a fully non-probabilistic way. The calculation has been extended to all transitions between p and s states having main quantum numbers not exceeding 6. An evident similarity between the intensity pattern obtained from the Joule-Lenz law and the corresponding quantum-mechanical transition pro-babilities has been shown.