期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Determination of trace elements in maifanite by outer cover electrode atomic emission spectrometry 被引量:1
1
作者 LIJianqiang LUYiqiang JIANGWei 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期161-165,共5页
Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer ... Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer cover electrode atomic emission spectrometry, and thedetermination conditions were studied systematically. The results show that the concentrations ofelements, which are beneficial to human health, are higher, and the elements harmful to peoplehealth such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy werealso discussed. 展开更多
关键词 atomic emission spectrometry outer cover electrode DETERMINATION TRACEELEMENTS maifanite
下载PDF
Determination of Carbon by Means of Microwave Plasma Torch Atomic Emission Spectrometry
2
作者 ZHANG Han-qi YUAN Xiang-lin +1 位作者 YE Dong-mei ZHAO Xiao-jun and JIN Qin-han (Department Of Chemistry, Jilin University, Changchun, 130023)ZHU Zhi-ping(Department of Chemistry, Northeast Normal University, Changchun, 130024) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1996年第1期32-36,共5页
The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon wa... The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon was 0. 047μg/mL.The method was applied to the analysis for tap water and results were satisfactory. 展开更多
关键词 Microwave plasma torch atomic emission spectrometry CARBON
下载PDF
A Study on Determination of Some Trace Nonmetals by Microwave Induced Plasma Atomic Emission Spectrometry
3
作者 Zhang Jinsheng, Ye Dongmei, Zhang Hanqi and Jin Qinhan (Department of Chemistry, Jilin University, Changchun) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1992年第1期29-30,共2页
In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the res... In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the resonance lines of most nonmetals lie in the vacuum ultraviolet spectral region and the ionic lines of these elements are difficult to be used because the ionization potentials of the elements are very high. And furthermore only He plasma can efficiently excit those ionic resonance lines. The practical application of HeICP-AES to determining the nonmetals is also difficult because its operating and perchace costs are very high. In contrast to HeICPAES, the costs of He microwave induced plasma (MIP)-AES are relatively low, HeMIP has a high excitation capability which can excite ionic lines of various nonmetals and the nonmetals can be determined by HeMIP-AES with a high sensitivity. 展开更多
关键词 Microwave induced plasma atomic emission spectrometry NONMETALS
下载PDF
Studies on Combination of Flow Injection and Microwave Plasma Torch-Atomic Emission Spectrometry
4
作者 YE Dong-mei, ZHAO Jing-hong, ZHANG Han-qi and JIN Qin-han (Department of Chemistry, Jilin University, Changchun, 130023)DONG De-fan (Hebei College of Geology, Shijiazhuang, 050031) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第3期246-247,共2页
Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma syst... Although the flow injection(FI) as a sample introduction technique has been extensively applied to atomic spectrometry, such as ICP-AES and AAS, very little has been done so far on coupling FI to microwave plasma systems. Gehlausen et al. determined aqueous fluorine by coupling flow injection analysis (FIA) with HeMIP 展开更多
关键词 Microwave plasma torch Flow injection atomic emission spectrometry
下载PDF
On Line Anion Exchange Preconcentration in Microwave Plasma Torch Atomic Emission Spectrometry
5
《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1994年第1期43-44,共2页
OnLineAnionExchangePreconcentrationinMicrowavePlasmaTorchAtomicEmissionSpectrometryLIANGFeng;ZHANGHan-qiandJ... OnLineAnionExchangePreconcentrationinMicrowavePlasmaTorchAtomicEmissionSpectrometryLIANGFeng;ZHANGHan-qiandJINQin-han(Departm... 展开更多
关键词 Microwave plasma torch atomic emission spectrometry Preconcen-tration
下载PDF
DeterminationofNi,Ca,Mg,CuandPbinWolframbyInductivelyCoupledPlasmaAtomicEmisionSpectrometry
6
作者 王春梅 张淑珍 《Rare Metals》 SCIE EI CAS CSCD 1997年第1期28-31,共4页
The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensa... The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensated by internal reference element. It is also showed that the stability of plasma caused by perhydrol matrix was effectively improved. The replicate experiment and recovery experiment revealed perfect precision and accuracy. Results got by two methods were just the same. 展开更多
关键词 WOLFRAM Trace elements atomic emission spectrometry
下载PDF
Determination of Cd,Pb and Sr by Microwave Plasma Torch Atomic Emision Spectrometry Using an Electrothermal Vaporization Sample Introduction System
7
作者 ZHAO Li-wei ZHANG Han-qí +4 位作者 CAO Yan-bo YANG Wen-jun JIN Qun JIN Qin-han FU Yao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1998年第4期22-26,共5页
A method for the determination of Cd,Pb and Sr by microwave plasma torch(MPT)atomic emission spectrometry(AES)was developed.Th e samples were introduced into the MPT with an elec trothermal vaporization(ETV)device.The... A method for the determination of Cd,Pb and Sr by microwave plasma torch(MPT)atomic emission spectrometry(AES)was developed.Th e samples were introduced into the MPT with an elec trothermal vaporization(ETV)device.The effects of some experimental conditions on the de-termination of Cd,Pb and Sr were examined.The effects of easily ionized elements on the emis-sion intensity of Cd,Pb and Sr were studied in detail.The detection limits for Cd,Pb and Sr are 2.4,4.0 and 1.3 ng/mL,respectively. 展开更多
关键词 atomic emission spectrometry Microwave plasma torch Electrothermal vaporization
下载PDF
Determination of wholesome elements and heavy metals in safflower(Carthamus tinctorius L.)from Xinjiang and Henan by ICP-MS/ICP-AES 被引量:9
8
作者 Ling-Han Jia Yi Liu Yu-Zhen Li 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第2期100-103,共4页
An inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma atomic emission spectrometry (ICP-AES) was developed to determine 19 elements in safflower, a traditional Chinese medicinal he... An inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma atomic emission spectrometry (ICP-AES) was developed to determine 19 elements in safflower, a traditional Chinese medicinal herb from Xinjiang Autonomous Region and Henan Province of China. Totally 19 elements in safflower included heavy metals, i.e. As, Cd, Cu, Hg and Pb, and wholesome elements, i.e. Al, Ca, Co, Cr, Fe, Mg, Mn, Mo, Ni, P, Se, Sr, V and Zn. The results showed that the concentrations of heavy metals in safflower samples were both low, all of which met the national hygiene standards except for Pb in Xinjiang sample. Meanwhile, the distribution tendency of elements in the two samples was similar, which indicated that the plant might absorb given elements in a proportional way. The method can be used for the quality control of elements in safflower, and it provides a way for the determination of the contents of safflower from Xinjiang and Henan. 展开更多
关键词 inductively coupled plasma mass spectrometry inductively coupled plasma atomic emission spectrometry wholesome elements heavy metals SAFFLOWER
下载PDF
Enrichment of Trace Scandium with Microcrystalline Naphthalene and Subsequent ICP-AES Determination
9
作者 Xiong Hongchun, Liao Zhenhuan, Peng Tianyou, Deng Zhonghua, Jiang Zucheng(College of Chemistry, Wuhan University, Wuhan 430072,China) 《Wuhan University Journal of Natural Sciences》 EI CAS 1998年第2期205-208,共4页
A new method is proposed to preconcentrate and separate trace scandium from a large volume of aqueous solution by solid liquid extraction with microcrystalline naphthalene. Scandium oxinate can be adsorbed onto microc... A new method is proposed to preconcentrate and separate trace scandium from a large volume of aqueous solution by solid liquid extraction with microcrystalline naphthalene. Scandium oxinate can be adsorbed onto microcrystalline naphthalene quantitatively under certain conditions. The effects of various experimental parameters have been optimized. The influence of additive of cobalt (II) on recovery of scandium (III) is studied in detail. The proposed method has been used for determination of Sc in Certified Reference Material of “Vehicle Exhaust Particulates”. 展开更多
关键词 Key words scandium COBALT microcrystalline naphthalene inductively coupled plasma atomic emission spectrometry (ICP AES) solid liquid extraction
下载PDF
Experimental Study on Plasma Temperature of Semiconductor Bridge
10
作者 吴蓉 朱顺官 +2 位作者 张琳 李燕 冯红艳 《Defence Technology(防务技术)》 SCIE EI CAS 2012年第1期35-40,共6页
The plasma temperature of the semiconductor bridge (SCB) was measured in real-time according to relative intensity ratio of dual lines of atomic emission spectrum.The plasma temperature under different discharge pulse... The plasma temperature of the semiconductor bridge (SCB) was measured in real-time according to relative intensity ratio of dual lines of atomic emission spectrum.The plasma temperature under different discharge pulses and the influence of discharge pulse energy on it were studied.The results show that the plasma peak temperature rises gradually with the increase of initial discharging voltage and charging capacitance.For the capacitance of 22 μF,if the initial discharging voltage increases from 21 V to 63 V,the plasma peak temperature rises from 2 000 K to 6 200 K.For the discharging voltage of 39 V,the peak temperature rises from 2 200 K to 3 800 K when the capacitance increases from 6.8 μF to 100 μF.The change of pulse discharge has a very small effect on the plasma temperature at the late time discharge (LTD).In view of the change of plasma temperature with the pulse energy,the discharging voltage has a greater effect on the plasma temperature than the capacitance.The results provide some experimental basis for the further research on SCB ignition and detonation mechanisms. 展开更多
关键词 plasma physics semiconductor bridge plasma temperature atomic emission spectrometry discharge pulse
下载PDF
Determination of Boron in Refractories
11
作者 WANG Yanni HAN Dan +1 位作者 LEI Xiaoyu ZHANG Yajing 《China's Refractories》 CAS 2020年第2期37-41,共5页
Refractory materials have been widely used in high-temperature industries,in which the boron content has a great influence on the performance.To control the detection quality and satisfy the requirement of production ... Refractory materials have been widely used in high-temperature industries,in which the boron content has a great influence on the performance.To control the detection quality and satisfy the requirement of production and scientific research of refractories,conditional tests involving three methods for the boron determination(alkali titrimetry,inductively coupled plasma atomic emission spectrometry(ICP-AES),and curcumin absorption spectrophotometry)were carried out in this work.The affecting factors on the determination of boron were analyzed and discussed by performing the experiment.The results show that compared with curcumin absorption spectrophotometry,alkali titrimetry and ICP-AES have the advantages of simple operation,quick analysis and high precision(relative standard deviation<5%),which are more appropriate for boron determination in refractories. 展开更多
关键词 REFRACTORIES BORON DETERMINATION alkali titrimetry inductively coupled plasma atomic emission spectrometry curcumin absorption spectrophotometry
下载PDF
Preparation of Chelating Cellulose Filters and Their Application to the Separation and Enrichment of Trace Elements
12
作者 LIU Chun-ming(Department of Changchun Normal College, Changchun,130032)GUO Yi-hang and ZHAO Xiao-liang(Center for Analysis and Testing, Northeast Normal University, Changchun, 130024) DING Lan(Center for Analysis and Testing ,Jilin University, Changchun, 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1995年第4期299-305,共7页
hreekinds of chelating cellulose filters were prepared and ten trace elements were preconcentrated simultaneously on the microcolumn that was filled with the chelating cellulose filters. Alkali and alkaline earth meta... hreekinds of chelating cellulose filters were prepared and ten trace elements were preconcentrated simultaneously on the microcolumn that was filled with the chelating cellulose filters. Alkali and alkaline earth metal ions were quantitatively separated as matrix elements at the selected pH values. The microcolumn has high enrichment factors and recoveries. 展开更多
关键词 Chelating cellulose Microcolumn Inductively coupled plasma atomic emission spectrometry Separation and enrichment
下载PDF
Comparison of 66 chemical element contents in normal and benign hyperplastic prostate
13
作者 Vladimir Zaichick Sofia Zaichick 《Asian Journal of Urology》 CSCD 2019年第3期275-289,共15页
Objective:The aim of this study was to clarify the differences between the prostatic levels of chemical elements in patients with benign prostatic hyperplasia(BPH)and healthy male.Methods:We evaluated the prostatic le... Objective:The aim of this study was to clarify the differences between the prostatic levels of chemical elements in patients with benign prostatic hyperplasia(BPH)and healthy male.Methods:We evaluated the prostatic level of 66 chemical elements in 43 patients with BPH and 37 healthy males.Measurements were performed using five instrumental analytical methods.Results:In the hyperplastic prostates,we have observed a significant increase in the mean level of Bi,Cr,Hg,K,Sb,and Se accompanied a significant decrease in the mean level of Al,Ce,Cs,Dy,Er,Gd,Ho,La,Mo,Nd,Pb,Pr,Sm,Sn,Tb,Tm,U,and Y.No differences were found in the mean prostatic level of other chemical elements including Ag,Al,Au,B,Ba,Be,Br,Ca,Cd,Co,Cu,Fe,Li,Mg,Mn,Na,Nb,Ni,P,Rb,S,Sc,Si,Th,Ti,Tl,Yb,Zn,and Zr between BPH patients and healthy males.Conclusions:The finding of chemical element contents and correlation between pairs of chemical element mass fractions indicates that there is a great disturbance of prostatic chemical element metabolism in BPH gland.Trace elements Bi,Cr,Hg,K,Sb,and Se may be regarded as the possible tissue biomarkers of hyperplastic transformation of prostate gland.Obtained data did not confirm a critical role of Cd and Pb accumulation in the pathogenesis of BPH.A potential age-related Zn,Fe,and Se deficiency in the prostate tissue has not been found as being involved in the etiology of BPH. 展开更多
关键词 Benign prostate hyperplasia Prostatic chemical element contents Trace element supplementations Energy dispersive Xray fluorescence analysis Neutron activation analysis Inductively coupled plasma atomic emission and mass spectrometry
下载PDF
Levels of chemical element contents in thyroid as potential biomarkers for cancer diagnosis (a preliminary study)
14
作者 Vladimir Zaichick Sofia Zaichick 《Journal of Cancer Metastasis and Treatment》 CAS 2018年第1期702-716,共15页
Aim:Thyroid cancer is an internationally important health problem.The aim of this exploratory study was to evaluate whether significantchanges in the thyroid tissue levels of Al,B,Ba,Br,Ca,Cl,Cu,Fe,I,K,Li,Mg,Mn,Na,P,S... Aim:Thyroid cancer is an internationally important health problem.The aim of this exploratory study was to evaluate whether significantchanges in the thyroid tissue levels of Al,B,Ba,Br,Ca,Cl,Cu,Fe,I,K,Li,Mg,Mn,Na,P,S,Si,Sr,V,and Zn exist in the malignantly transformed thyroid.Methods:Thyroid tissue levels of twenty chemical elements were prospectively evaluated in 41 patients with thyroid malignant tumors and 105 healthy inhabitants.Measurements were performed using a combination of non-destructive and destructive methods:instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry,respectively.Tissue samples were divided into two portions.One was used for morphological study while the other was intended for trace element analysis.Results:It was found that contents of Al,B,Br,Ca,Cl,Cu,K,Mg,Mn,Na,P,S,and Si were significantly higher(approximately 3.2,4.6,9.3,1.8,2.3,3.6,1.6,1.6,1.6,1.2,2.5,1.1,and 2.8 times,respectively)while content of I lower(nearly 26 times)in cancerous tissues than in normal tissues.Conclusion:There are considerable changes in chemical element contents in the malignantly transformed tissue of thyroid. 展开更多
关键词 Thyroid malignant tumors intact thyroid chemical elements biomarkers for cancer diagnosis instrumentalneutron activation analysis inductively coupled plasma atomic emission spectrometry
原文传递
上一页 1 下一页 到第