期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Elemental Content in Brown Rice by Inductively Coupled Plasma Atomic Emission Spectroscopy Reveals the Evolution of Asian Cultivated Rice 被引量:4
1
作者 Yawen Zeng Luxiang Wang +4 位作者 Juan Du Jiafu Liu Shuming Yang Xiaoying Pu Fenghui Xiao 《Journal of Integrative Plant Biology》 SCIE CAS CSCD 2009年第5期466-475,共10页
The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inducti... The phylogenetic relationship for classification traits and eight mineral elements in brown rice (Oryza sativa L.) from Yunnan Province in China was carried out using microwave assisted digestion followed by inductively coupled plasma atomic emission spectroscopy, and the analytical procedures were carefully controlled and validated. In general, the results show that the mean levels of K, Ca, Mg, Fe and Cu in brown rice for 789 accessions of rice landraces was distinctly lower than that of improved cultivars. They further demonstrate that Ca plays an important role in the differentiation of subspecies indica-japonica, especially to enhance adaptation of cold stress, and that five mineral elements in brown rice enhance the eurytopicity from landrace to improved cultivar. Hierarchical cluster analysis, using average linkage from SPSS software based on eight mineral elements in brown rice, showed that Yunnan rice could be grouped into rice landrace and improved cultivar, with the rice landrace being further clustered into five subgroups, and that, interestingly, purple rice does not cluster with either of the groups. Our present data confirm that indica is the closest relative of late rice and white rice, and that they constitute rice landraces together, whereas japonica is the closest relatives of non-nuda, early-mid and glutinous rice. It is further shown that japonica, non-nuda, early-mid, glutinous, white and red rice might be more primitive than indica, nuda, late, non-glutinous and purple rice, respectively. 展开更多
关键词 brown rice core collection inductively coupled plasma atomic emission spectroscopy mineral element phylogenetic relationship
原文传递
Atomic Emission Spectrographic Analysis of High-purity Gallium with Prior Partial Dissolution of Matrix
2
作者 陈家英 钟秀霞 梁树权 《Rare Metals》 SCIE EI CAS CSCD 1992年第2期129-134,共6页
An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0.... An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0.5mol/L)to a small residue of which Ga was then removed by extraction with 1 ml isopropyl ether.The concentrated impurities were determined by AES procedure.The recoveries for the ele- ments at the range of 0.02~0.2 μg are 95~103%;the relative standard deviations for determined impurities overa rangeofn.10^(-7)~n·10^(-8)% are 4.3~12%;the detection limit of most elements can reach n·10^(-7)~ n·10^(-8)% level with the exception of Hg and Pt.This method has been successfully used to analyze many sam- ples sent by factories and institutes. 展开更多
关键词 High-purity gallium Trace elements atomic emission spectroscopy
下载PDF
A Study on the Determination of Copper by Microwave Induced Plasma Atomic Emission Spectrometry (MIP-AES)
3
作者 Zhang Hanqi, Yu Shirong, Zhang Xiaohui, Lu Hui and Jin Qinhan (Department of Chemistry, Jilin University, Changchun) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1990年第3期177-182,共6页
The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol in... The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol into the MIP. The desolvation system consisted of a condenser associated with a concentrated H2SO4 absorption cell. Various experimental conditions and interferences from easily ionised elements (EIEs) were also studied and some practical samples were analyzed. 展开更多
关键词 COPPER Microwave induced plasma atomic emission spectroscopy Easly ionised elements
下载PDF
Determination of Iron in Water Solution by Time-Resolved Femtosecond Laser-Induced Breakdown Spectroscopy 被引量:3
4
作者 Sergey S.GOLIK Alexey A.ILYIN +3 位作者 Michael Yu.BABIY Yulia S.BIRYUKOVA Vladimir V.LISITSA Oleg A.BUKIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期975-978,共4页
The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphi... The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection. 展开更多
关键词 femtosecond laser-induced breakdown spectroscopy LIBS femtosecond plasma IRON analysis of water atomic emission spectroscopy limit of detection
下载PDF
Dental Erosion by Beverages and Determination of Trace Elements in Teeth by Atomic Absorption Spectrometry
5
作者 Safaa Sabri Najim Maiada Abdulla Adnan 《American Journal of Analytical Chemistry》 2016年第7期548-555,共9页
The analysis of trace elements in human tooth for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostic and forensic science. This study investiga... The analysis of trace elements in human tooth for use as biomarkers continues to generate considerable interest in environmental and bioanalytical studies, medical diagnostic and forensic science. This study investigated concentrations of essential and toxic elements (Zn, Cu, Pb, Ni, Co and Cd) using flame atomic absorption spectroscopy (FAAS) and (Na and K) flame atomic emission spectroscopy (FAES) in human tooth obtained from Misan province, Iraq. The influence of smoking habits and born children on the levels of trace elements in additional to dental erosion by some beverages in the tooth samples were investigated. The overall of mean concentrations of (Zn 185.2 ppm, Cu 36.11 ppm, Pb 18.63 ppm, Ni 13.44 ppm, Co 3.45 ppm, and Cd 0.58 ppm, Na 11.683 ppm and K 115.27 ppm), (Zn 178.243 ppm, Cu 35.877 ppm, Pb 15.64 ppm, Ni 12.89 ppm, Co 3.421 ppm, Cd 0.455 ppm, Na 11,558.04 ppm and K 114.04 ppm) in smokers and non-smokers tooth groups respectively, (Zn 81.12 ppm, Cu 24.37 ppm, Pb 11.18 ppm, Ni 13.68 ppm, Co 3.32 ppm, Cd 0.44 ppm, Na 8227 ppm and K 76.42 ppm), (Zn 80.58 ppm, Cu 24.30 ppm, Pb 10.86 ppm, Ni 12.74 ppm, Co 2.71 ppm, Cd 0.23 ppm, Na 8165 ppm and K 72.80 ppm) in mothers and wives tooth groups respectively. However the w/w% loss of tooth immersed in following order of beverages (green tea, black tea, cinnamon, hibiscus, vinegar and citrus aurantifolia (9.09, 9.68, 12.36, 15.01, 16.77 and 17.38), (8.19, 8.25, 9.76, 13.37, 14.02 and 15.33) in smokers and non-smokers groups respectively, (11.25, 11.47, 13.30, 15.75, 19.58, and 20.91), (8.31, 7.96, 11.39, 13.49, 17.40, and 17.67) in mothers and wives groups respectively. However, there is a statistically significant variance found Zn (t<sub>cal</sub> 5.029, t<sub>tab</sub> 2.131), Pb (t<sub>cal</sub> 4.8538, t<sub>tab</sub> 2.131), Ni (t<sub>ca</sub><sub>l</sub> 5.243, t<sub>tab</sub> 2.131), Cd (t<sub>cal</sub> 3.9062, t<sub>tab</sub> 2.131) and Na (t<sub>cal</sub> 3.0832, t<sub>tab</sub> 2.131) between smokers and non-smokers tooth groups. However, the Co (t<sub>cal</sub> 2.7403, t<sub>tab</sub> 2.131) also shows statistically significant variance between mothers and wives groups. There is no statistically significant variance in w/w% loss after immersed the tooth in some beverages but in general it was higher in smokers than non-smokers and in mothers higher than wives. 展开更多
关键词 Flame atomic Absorption spectroscopy Flame atomic emission spectroscopy Trace Element Concentrations BIOMARKER
下载PDF
Formation and destruction of striation plasmas in helium glow discharge at medium pressures
6
作者 朱海龙 黄琪翔 +2 位作者 吴一繁 李昱瑞 任克昌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第5期176-182,共7页
The striation plasmas are usually generated within a positive column of glow discharge,where rich and complex physical interactions are involved,especially,in the medium or high pressures.Along these lines,our work ai... The striation plasmas are usually generated within a positive column of glow discharge,where rich and complex physical interactions are involved,especially,in the medium or high pressures.Along these lines,our work aims to thoroughly investigate the formation and destruction of helium striation plasmas at kPa level pressures.The characteristics of the helium striation plasmas,and especially the optical emission properties are explored.The emission lines of 706.52 nm and391.44 nm related to the energetic electrons and the high-energy metastable helium atoms respectively,were focused on in this work.The formation of striation plasmas in a helium glow discharge,is mainly associated with the instability originating from the stepwise ionization of high-energy metastable state atoms,Maxwellization of the electron distribution functions and gas heating.Additionally,the destruction effect of helium striation plasmas is of great significance when a small amount of nitrogen or oxygen is mixed into the discharge plasmas.The reduction of the mean electron energy and the consumption of the high-energy metastable helium atoms are considered as the underlying reasons for the destruction of striation plasmas. 展开更多
关键词 striation plasmas medium pressures atomic emission spectroscopy helium discharge metastable atoms ionization wave
下载PDF
Study of Direct Determination of Trace Lanthanum in Biological Samples by ICP-AES Combined with Fluo
7
作者 秦永超 江祖成 +2 位作者 蔡祥歆 张淑娴 曾云鹗 《Journal of Rare Earths》 SCIE EI CAS CSCD 1996年第1期54-58,共5页
A new method for direct determination of lanthanum in solid biological materials by fluorination electrothermal vaporization ICP-AES technique with polytetrafluoroethylene(PTFE) disperser as a fluorination agent has b... A new method for direct determination of lanthanum in solid biological materials by fluorination electrothermal vaporization ICP-AES technique with polytetrafluoroethylene(PTFE) disperser as a fluorination agent has been described. The effect of particle size on the signal intensity of La has been investigated. The vaporization behaviour of lanthanum and the main factors affecting fluorinating vaporization have been observed.Under optimum experimental conditions,the detection limit of La to this method is 2.0 ng/ml,and the RSD is 4.5%.The proposed method has been applied to determining directly trace lanthanum in solid biological standard reference materials without any chemical pretreatment,and the determined values are in good agreement with the certified ones. 展开更多
关键词 Fluorination vaporization Particle size effect Biological sample LANTHANUM Inductively coupled plasma atomic emission spectroscopy
下载PDF
Ultrasensitive determination of mercury by solution anode glow discharge atomic emission spectrometry coupled with hydride generation
8
作者 Mingli Yuan Xiaoxu Peng +3 位作者 Fen Ge Mingyue Zhao Qing Li Zheng Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2020年第10期2814-2818,共5页
An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the me... An innovative method for the ultrasensitive detection of mercury by solution anode glow discharge atomic emission spectroscopy(SAGD-AES) coupled with hydride generation(HG) was first investigated.In this method,the mercury vapor generated by the HG was transmitted to the SAGD through the miniature hollow tungsten tube for excitation and detected by a miniaturized spectrograph.A thorough parametric evaluation of the HG and SAGD system was performed,including the type and concentration of ca rrier acid,He flow rate,concentrations of NaBH4,discha rge current and discharge gap.Under optimal operating conditions,the detection limit for Hg^(2+) achieved 0.03 μg/L,with a relative standard deviation of 1.1% at the Hg^(2+) concentration of 5 μg/L.Moreover,the correlation coefficient of the calibration curve was 0.9996 in the range between 0.1 and 10 μg/L.The accuracy and practicability of HG-SAGD-AES were verified by measuring GBW09101 b(human hair),GBW10029(fish),soil and rice samples.The results showed good agreement with the certified values and values from direct mercury analyzer(DMA). 展开更多
关键词 Solution anode glow discharge Hydride generation atomic emission spectroscopy MERCURY
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部