Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based...Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.展开更多
Two experimental techniques have been used to quantify the atomic oxygen density in the case of hot air plasma generated by a microwave (MW) resonant cavity. The latter operates at a frequency of 2.45 GHz inside a c...Two experimental techniques have been used to quantify the atomic oxygen density in the case of hot air plasma generated by a microwave (MW) resonant cavity. The latter operates at a frequency of 2.45 GHz inside a cell of gas conditioning at a pressure of 600 mbar, an injected air flow of 12 L/min and an input MW power of 1 kW. The first technique is based on the standard two photon absorption laser induced fluorescence (TALIF) using xenon for calibration but applied for the first time in the present post discharge hot air plasma column having a temperature of about 4500 K near the axis of the nozzle. The second diagnostic technique is an actinometry method based on optical emission spectroscopy (OES). In this case, we compared the spectra intensities of a specific atomic oxygen line (844 nm) and the closest wavelength xenon line (823 nm). The two lines need to be collected under absolutely the same spectroscopic parameters. The xenon emission is due to the addition of a small proportion of xenon (1% Xe) of this chemically inert gas inside the air while a further small quantity of H2 (2~) is also added in the mixture in order to collect OH(A- X) and NH(A-X) spectra without noise. The latter molecular spectra are required to estimate gas and excitation temperatures. Optical emission spectroscopy measurements, at for instance the position z=12 mm on the axis plasma column that leads to a gas measured temperature equal to 3500 K, an excitation temperature of about 9500 K and an atomic oxygen density 2.09× 1017+ 0.2×1017 cm-3. This is in very good agreement with the TALIF measurement, which is equal to 2.0×101T cm-3.展开更多
The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol in...The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol into the MIP. The desolvation system consisted of a condenser associated with a concentrated H2SO4 absorption cell. Various experimental conditions and interferences from easily ionised elements (EIEs) were also studied and some practical samples were analyzed.展开更多
Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or...Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or not. Subjecting the water sample to 0.3 Tesla magnetic field for 14 hours led to instantaneous effects on the examined water properties, where a reduction in the values of pH (7%) and interfacial tension (0.2%) was observed, whereas an increase (8%) in water electrical conductivity was recorded. Similar behaviours with slight changes in trend were observed after storing the samples for six days, which indicates a creation of permanent effects. Other experiments were conducted to explore the impact of magnetizing water sample containing inorganic mercury prior to detection by emission spectroscopy. Samples were prepared with different mercury concentrations and derivatized by using tin chloride (SnCI2). The generated mercury vapour species were transported with aid of carrier gas into a dielectric barrier discharge plasma atomizer, in which the mercury signal at 253.65 nm was recorded. The results have shown 3.5%-7.5% increase in the signal intensities recorded for the magnetized samples, mostly attributed to a reduction in the sample surface tension and other reasons, which facilitates analyte derivatization.展开更多
An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0....An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0.5mol/L)to a small residue of which Ga was then removed by extraction with 1 ml isopropyl ether.The concentrated impurities were determined by AES procedure.The recoveries for the ele- ments at the range of 0.02~0.2 μg are 95~103%;the relative standard deviations for determined impurities overa rangeofn.10^(-7)~n·10^(-8)% are 4.3~12%;the detection limit of most elements can reach n·10^(-7)~ n·10^(-8)% level with the exception of Hg and Pt.This method has been successfully used to analyze many sam- ples sent by factories and institutes.展开更多
For the first time, absolute densities of atomic nitrogen in its ground state (N4S) have been measured in hot dry and humid air plasma columns under post-discharge regime. The determination of space-resolved absolute ...For the first time, absolute densities of atomic nitrogen in its ground state (N4S) have been measured in hot dry and humid air plasma columns under post-discharge regime. The determination of space-resolved absolute densities leads to obtain the dissociation degrees of molecular nitrogen in the plasma. The hot plasmas are generated inside an upstream gas-conditioning cell at 600 mbar when the air gas flow is directly injected at 10 slm in a microwave resonant cavity (2.45 GHz, 1 kW) placed in the downstream side. Density measurements based on laser induced fluorescence spectroscopy with two-photon excitation (TALIF), are more particularly performed along the radial and axial positions of the plasma column. Calibration of TALIF signals is performed in situ (i.e. in the same gas-conditioning cell but without plasma) using an air gas mixture containing krypton. Optical emission spectroscopy is considered to estimate the rotational gas temperature by adding a small amount of H2 in dry air to better detect OH (A-X) spectra. The rotational temperatures in humid air plasma column (50% of humidity) are larger than those of dry air plasma column by practically 30% near the nozzle of resonant cavity on the axis of the plasma column. This is partly due to attachment heating processes initiated by water vapor. A maximum of the measured absolute nitrogen density is also observed near the nozzle which is also larger for humid air plasma column. The obtained dissociation degrees of molecular nitrogen in both dry and humid air plasma along the air plasma column are lower than the cases where only thermodynamic equilibrium is assumed. This is characteristic of the absence of chemical and energetic equilibria not yet reached in the air plasma column dominated by recombination processes.展开更多
基金funded by the Ministry of Education,Science and Technological Development of the Republic of Serbia(Nos.451-03-68/2022-14/200017 and 451-03-68/2022-14/200146)the financial support of the State Committee on Science and Technology of the Republic of Belarusthe Belarusian Republican Foundation for Fundamental Research(No.F20SRBG-001)。
文摘Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements.
文摘Two experimental techniques have been used to quantify the atomic oxygen density in the case of hot air plasma generated by a microwave (MW) resonant cavity. The latter operates at a frequency of 2.45 GHz inside a cell of gas conditioning at a pressure of 600 mbar, an injected air flow of 12 L/min and an input MW power of 1 kW. The first technique is based on the standard two photon absorption laser induced fluorescence (TALIF) using xenon for calibration but applied for the first time in the present post discharge hot air plasma column having a temperature of about 4500 K near the axis of the nozzle. The second diagnostic technique is an actinometry method based on optical emission spectroscopy (OES). In this case, we compared the spectra intensities of a specific atomic oxygen line (844 nm) and the closest wavelength xenon line (823 nm). The two lines need to be collected under absolutely the same spectroscopic parameters. The xenon emission is due to the addition of a small proportion of xenon (1% Xe) of this chemically inert gas inside the air while a further small quantity of H2 (2~) is also added in the mixture in order to collect OH(A- X) and NH(A-X) spectra without noise. The latter molecular spectra are required to estimate gas and excitation temperatures. Optical emission spectroscopy measurements, at for instance the position z=12 mm on the axis plasma column that leads to a gas measured temperature equal to 3500 K, an excitation temperature of about 9500 K and an atomic oxygen density 2.09× 1017+ 0.2×1017 cm-3. This is in very good agreement with the TALIF measurement, which is equal to 2.0×101T cm-3.
基金Supported by the Natinoal Natural Science Foundation of China.
文摘The determination of copper by MIP-AES was investigated in detail. Aqueous samples were introduced from an ultrasonic nebulizer and the solvent was removed by a desolvation device before introduction of the aerosol into the MIP. The desolvation system consisted of a condenser associated with a concentrated H2SO4 absorption cell. Various experimental conditions and interferences from easily ionised elements (EIEs) were also studied and some practical samples were analyzed.
文摘Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or not. Subjecting the water sample to 0.3 Tesla magnetic field for 14 hours led to instantaneous effects on the examined water properties, where a reduction in the values of pH (7%) and interfacial tension (0.2%) was observed, whereas an increase (8%) in water electrical conductivity was recorded. Similar behaviours with slight changes in trend were observed after storing the samples for six days, which indicates a creation of permanent effects. Other experiments were conducted to explore the impact of magnetizing water sample containing inorganic mercury prior to detection by emission spectroscopy. Samples were prepared with different mercury concentrations and derivatized by using tin chloride (SnCI2). The generated mercury vapour species were transported with aid of carrier gas into a dielectric barrier discharge plasma atomizer, in which the mercury signal at 253.65 nm was recorded. The results have shown 3.5%-7.5% increase in the signal intensities recorded for the magnetized samples, mostly attributed to a reduction in the sample surface tension and other reasons, which facilitates analyte derivatization.
文摘An improved method has been developed for enriching and determining trace In,Pt,Sn,Co,Hg,Pb,Ni, Bi,Pd,Cu and Ag in high-purity gallium.Sample was treated by PDM(partial dissolution of matrix)with HCl(11mol/L)-HNO_3(0.5mol/L)to a small residue of which Ga was then removed by extraction with 1 ml isopropyl ether.The concentrated impurities were determined by AES procedure.The recoveries for the ele- ments at the range of 0.02~0.2 μg are 95~103%;the relative standard deviations for determined impurities overa rangeofn.10^(-7)~n·10^(-8)% are 4.3~12%;the detection limit of most elements can reach n·10^(-7)~ n·10^(-8)% level with the exception of Hg and Pt.This method has been successfully used to analyze many sam- ples sent by factories and institutes.
文摘For the first time, absolute densities of atomic nitrogen in its ground state (N4S) have been measured in hot dry and humid air plasma columns under post-discharge regime. The determination of space-resolved absolute densities leads to obtain the dissociation degrees of molecular nitrogen in the plasma. The hot plasmas are generated inside an upstream gas-conditioning cell at 600 mbar when the air gas flow is directly injected at 10 slm in a microwave resonant cavity (2.45 GHz, 1 kW) placed in the downstream side. Density measurements based on laser induced fluorescence spectroscopy with two-photon excitation (TALIF), are more particularly performed along the radial and axial positions of the plasma column. Calibration of TALIF signals is performed in situ (i.e. in the same gas-conditioning cell but without plasma) using an air gas mixture containing krypton. Optical emission spectroscopy is considered to estimate the rotational gas temperature by adding a small amount of H2 in dry air to better detect OH (A-X) spectra. The rotational temperatures in humid air plasma column (50% of humidity) are larger than those of dry air plasma column by practically 30% near the nozzle of resonant cavity on the axis of the plasma column. This is partly due to attachment heating processes initiated by water vapor. A maximum of the measured absolute nitrogen density is also observed near the nozzle which is also larger for humid air plasma column. The obtained dissociation degrees of molecular nitrogen in both dry and humid air plasma along the air plasma column are lower than the cases where only thermodynamic equilibrium is assumed. This is characteristic of the absence of chemical and energetic equilibria not yet reached in the air plasma column dominated by recombination processes.