期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Atomic Interference Method for Direct Measurement of the Wigner Function of a Cavity Field
1
作者 ZHENGShi-Biao 《Communications in Theoretical Physics》 SCIE CAS CSCD 2001年第2期213-215,共3页
We propose a scheme for the reconstruction of a cavity field state. In the scheme the cavity field is first displaced by a microwave source, and then is placed in front of one slit of the two-slit apparatus. Ground st... We propose a scheme for the reconstruction of a cavity field state. In the scheme the cavity field is first displaced by a microwave source, and then is placed in front of one slit of the two-slit apparatus. Ground state atoms pass through the apparatus, hitting upon the screen far away from the two-slit apparatus. The atom-field interaction is dispersive. The contrast of interference fringes is directly related to the Wigner function for the field state. The scheme can be easily generalized to measure the Wigner function of an entangled state of two spatially separated single-mode cavities. 展开更多
关键词 atomic interference Wigner function cavity field
下载PDF
CORRECTION OF WING INTERFERENCE WITH KALMAN FILTERING IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY
2
作者 Jin Fu YANG Zhe Xiu PIAO +2 位作者 Xian Jin ZENG Zhuo Yong ZHANG Xin Hai CHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第3期193-196,共4页
A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and... A Kalman filter was developed for correction of wing interference in ICP-AES.Modeling wing interference theoretically instead of experimentally, the filter can compensate the shift in wavelength position in scans, and therefore reduce the effect of the interference on detection limit. 展开更多
关键词 LINE CORRECTION OF WING interference WITH KALMAN FILTERING IN INDUCTIVELY COUPLED PLASMA atomic EMISSION SPECTROMETRY LA
下载PDF
A new ellipse fitting method of the minimum differential-mode noise in the atom interference gravimeter 被引量:1
3
作者 Aopeng Xu Zhaoying Wang +2 位作者 Delong Kong Zhijie Fu Qiang Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期190-195,共6页
Ellipse fitting is a useful tool to obtain the differential signal of two atom interference gravimeters. The quality standard of ellipse fitting should be the deviation between the true phase and the fitting phase of ... Ellipse fitting is a useful tool to obtain the differential signal of two atom interference gravimeters. The quality standard of ellipse fitting should be the deviation between the true phase and the fitting phase of the interference fringe. In this paper, we present a new algorithm to fit the ellipse. The algorithm is to minimize the differential noise of two interference gravimeters and obtain a more accurate value of the gravity gradient. We have theoretically derived the expression of the differential-mode noise and implemented the ellipse fitting in the program. This new algorithm is also compared with the classical methods. 展开更多
关键词 ellipse fitting atom interference gravity measurement
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部