A typical magnetic-resonance scheme employs a static bias magnetic field and an orthogonal driving magnetic field oscillating at the Larmor frequency, at which the atomic polarization precesses around the static magne...A typical magnetic-resonance scheme employs a static bias magnetic field and an orthogonal driving magnetic field oscillating at the Larmor frequency, at which the atomic polarization precesses around the static magnetic field. Here we demonstrate both theoretically and experimentally the variations of the resonance condition and the spin precession dynamics resulting from the parametric modulation of the bias field. We show that the driving magnetic field with the frequency detuned by different harmonics of the parametric modulation frequency can lead to resonance as well. Also, a series of frequency sidebands centered at the driving frequency and spaced by the parametric modulation frequency can be observed in the precession of the atomic polarization. We further show that the resonant amplitudes of the sidebands can be controlled by varying the ratio between the amplitude and the frequency of the parametric modulation. These effects could be used in different atomic magnetometry applications.展开更多
One of the peculiar phenomenons in non-zero magnetic resonance magnetometer is that, with the increase of the temperature, the magnetic resonance linewidth is narrowed at first instead of broadened due to the increasi...One of the peculiar phenomenons in non-zero magnetic resonance magnetometer is that, with the increase of the temperature, the magnetic resonance linewidth is narrowed at first instead of broadened due to the increasing collision rate. The magnetometer usually operates at the narrowest linewidth temperature to obtain the best sensitivity. Here, we explain this phenomenon quantitatively considering the nonlinear of the optical pumping in the cell and did experiments to verify this explanation. The magnetic resonance linewidth is measured using one amplitude-modulated pump laser and one continuous probe laser. The field is along the direction orthogonal to the plane of pump and probe beams. We change the temperature from 53℃ to 93℃ and the pumping light from 0.1 mW to 2 mW. The experimental results agree well with the theoretical calculations.展开更多
Based on the parametric resonance magnetometer(PRM)theory,this paper establishes an experimen-tal system of PRM.The experimental results are consistent with the theoretical predictions.A PRM has been developed with se...Based on the parametric resonance magnetometer(PRM)theory,this paper establishes an experimen-tal system of PRM.The experimental results are consistent with the theoretical predictions.A PRM has been developed with sensitivity of 0.5 pT/Hz^(1/2),which can detect the magnitude of residual magnetic field;furthermore,a proportion-integration-differentiation(PID)closed-loop magnetic compensation system of the residual magnetic field also has been realized.Compared with open-loop compensation,the PID closed-loop compensation reduces the average value of the residual magnetic field in the z-axis direction from 0.0244nT to-0.0023nT,and the mean-square error from 0.2083 nT to 0.0691 nT.In the same way,the average value of the residual magnetic field in the y-axis direction is reduced from 0.0816nT to-0.0042nT,and the mean-square error from 0.1316nT to 0.0461 nT.The magnitude of residual magnetic fields in both directions is decreased to the order of picotesla(pT).In addition,based on the signal waveforms of the magnetometer,a method of verifying the effect of magnetic compensation is proposed.展开更多
基金Project supported by the National Science Fund for Distinguished Young Scholars of China(Grant No.61225003)the National Natural Science Foundation of China(Grant Nos.61531003 and 61571018)the National High Technology Research and Development Program of China
文摘A typical magnetic-resonance scheme employs a static bias magnetic field and an orthogonal driving magnetic field oscillating at the Larmor frequency, at which the atomic polarization precesses around the static magnetic field. Here we demonstrate both theoretically and experimentally the variations of the resonance condition and the spin precession dynamics resulting from the parametric modulation of the bias field. We show that the driving magnetic field with the frequency detuned by different harmonics of the parametric modulation frequency can lead to resonance as well. Also, a series of frequency sidebands centered at the driving frequency and spaced by the parametric modulation frequency can be observed in the precession of the atomic polarization. We further show that the resonant amplitudes of the sidebands can be controlled by varying the ratio between the amplitude and the frequency of the parametric modulation. These effects could be used in different atomic magnetometry applications.
基金supported by the National Natural Science Foundation of China(Grant Nos.51675034 and 61273067)Beijing Natural Science Foundation(Grant No.7172123)
文摘One of the peculiar phenomenons in non-zero magnetic resonance magnetometer is that, with the increase of the temperature, the magnetic resonance linewidth is narrowed at first instead of broadened due to the increasing collision rate. The magnetometer usually operates at the narrowest linewidth temperature to obtain the best sensitivity. Here, we explain this phenomenon quantitatively considering the nonlinear of the optical pumping in the cell and did experiments to verify this explanation. The magnetic resonance linewidth is measured using one amplitude-modulated pump laser and one continuous probe laser. The field is along the direction orthogonal to the plane of pump and probe beams. We change the temperature from 53℃ to 93℃ and the pumping light from 0.1 mW to 2 mW. The experimental results agree well with the theoretical calculations.
基金the Shanghai Aerospace Advanced Technology Joint Research Fund(No.USCAST2019-23)the Oceanic Interdisciplinary Program of Shanghai Jiao Tong University(No.SL2021ZD202)。
文摘Based on the parametric resonance magnetometer(PRM)theory,this paper establishes an experimen-tal system of PRM.The experimental results are consistent with the theoretical predictions.A PRM has been developed with sensitivity of 0.5 pT/Hz^(1/2),which can detect the magnitude of residual magnetic field;furthermore,a proportion-integration-differentiation(PID)closed-loop magnetic compensation system of the residual magnetic field also has been realized.Compared with open-loop compensation,the PID closed-loop compensation reduces the average value of the residual magnetic field in the z-axis direction from 0.0244nT to-0.0023nT,and the mean-square error from 0.2083 nT to 0.0691 nT.In the same way,the average value of the residual magnetic field in the y-axis direction is reduced from 0.0816nT to-0.0042nT,and the mean-square error from 0.1316nT to 0.0461 nT.The magnitude of residual magnetic fields in both directions is decreased to the order of picotesla(pT).In addition,based on the signal waveforms of the magnetometer,a method of verifying the effect of magnetic compensation is proposed.