To improve welding quality, a method of proportional-integral-differential (PlD) parameters tuning based on pulsed gas metal arc welding (P-GMAW) control was put forward. Aiming at the request of dynamic responsiv...To improve welding quality, a method of proportional-integral-differential (PlD) parameters tuning based on pulsed gas metal arc welding (P-GMAW) control was put forward. Aiming at the request of dynamic responsiveness of PGMA W constant current control, a self-developed welding waveform wavelet analyzer was employed. By tuning the proportional parameter, integration time and differential time in sequence, the optimal PID parameters could be achieved. The results showed that, due to the PID parameters tuned by this method, the welding process was stable and the weld bead appearance was nice. The requirement of dynamic responsiveness of P-GMAW constant current control was fully met.展开更多
To determine the optimal or near optimal parameters of PID controller with incomplete derivation, a novel design method based on differential evolution (DE) algorithm is presented. The controller is called DE-PID co...To determine the optimal or near optimal parameters of PID controller with incomplete derivation, a novel design method based on differential evolution (DE) algorithm is presented. The controller is called DE-PID controller. To overcome the disadvantages of the integral performance criteria in the frequency domain such as IAE, ISE, and ITSE, a new performance criterion in the time domain is proposed. The optimization procedures employing the DE algorithm to search the optimal or near optimal PID controller parameters of a control system are demonstrated in detail. Three typical control systems are chosen to test and evaluate the adaptation and robustness of the proposed DE-PID controller. The simulation results show that the proposed approach has superior features of easy implementation, stable convergence characteristic, and good computational efficiency. Compared with the ZN, GA, and ASA, the proposed design method is indeed more efficient and robust in improving the step response of a control system.展开更多
A new and intelligent design method for PID controller with incomplete derivation is proposed based on the ant system algorithm ( ASA) . For a given control system with this kind of PID controller, a group of optimal ...A new and intelligent design method for PID controller with incomplete derivation is proposed based on the ant system algorithm ( ASA) . For a given control system with this kind of PID controller, a group of optimal PID controller parameters K p * , T i * , and T d * can be obtained by taking the overshoot, settling time, and steady-state error of the system's unit step response as the performance indexes and by use of our improved ant system algorithm. K p * , T i * , and T d * can be used in real-time control. This kind of controller is called the ASA-PID controller with incomplete derivation. To verify the performance of the ASA-PID controller, three different typical transfer functions were tested, and three existing typical tuning methods of PID controller parameters, including the Ziegler-Nichols method (ZN),the genetic algorithm (GA),and the simulated annealing (SA), were adopted for comparison. The simulation results showed that the ASA-PID controller can be used to control different objects and has better performance compared with the ZN-PID and GA-PID controllers, and comparable performance compared with the SA-PID controller.展开更多
Controllable saturation reactors are widely used in reactive power compensation. The control system of controllable saturation reactor determines adaption speed, accuracy, and stability. First, an innovative type of c...Controllable saturation reactors are widely used in reactive power compensation. The control system of controllable saturation reactor determines adaption speed, accuracy, and stability. First, an innovative type of controllable saturation reactor is introduced. After that the control system is designed, and a self-tuning algorithm in PID controller is proposed in the paper. The algorithm tunes PID parameters automatically with different error signals caused by varied loads in power system. Then the feasibility of the above algorithm is verified by Simulink module of Matlab software. The results of simulation indicate that the control system can efficiently reduce adaption time and overshoot.展开更多
文摘To improve welding quality, a method of proportional-integral-differential (PlD) parameters tuning based on pulsed gas metal arc welding (P-GMAW) control was put forward. Aiming at the request of dynamic responsiveness of PGMA W constant current control, a self-developed welding waveform wavelet analyzer was employed. By tuning the proportional parameter, integration time and differential time in sequence, the optimal PID parameters could be achieved. The results showed that, due to the PID parameters tuned by this method, the welding process was stable and the weld bead appearance was nice. The requirement of dynamic responsiveness of P-GMAW constant current control was fully met.
基金the National Natural Science Foundation of China (60375001)the Scientific Research Foundation of Hunan Provincial Education Department (05B016).
文摘To determine the optimal or near optimal parameters of PID controller with incomplete derivation, a novel design method based on differential evolution (DE) algorithm is presented. The controller is called DE-PID controller. To overcome the disadvantages of the integral performance criteria in the frequency domain such as IAE, ISE, and ITSE, a new performance criterion in the time domain is proposed. The optimization procedures employing the DE algorithm to search the optimal or near optimal PID controller parameters of a control system are demonstrated in detail. Three typical control systems are chosen to test and evaluate the adaptation and robustness of the proposed DE-PID controller. The simulation results show that the proposed approach has superior features of easy implementation, stable convergence characteristic, and good computational efficiency. Compared with the ZN, GA, and ASA, the proposed design method is indeed more efficient and robust in improving the step response of a control system.
基金This work was supported by the National Natural Science Foundation of China (No. 50275150)the Foundation of Robotics Laboratory, Chinese Academy of Sciences( No. RL200002).
文摘A new and intelligent design method for PID controller with incomplete derivation is proposed based on the ant system algorithm ( ASA) . For a given control system with this kind of PID controller, a group of optimal PID controller parameters K p * , T i * , and T d * can be obtained by taking the overshoot, settling time, and steady-state error of the system's unit step response as the performance indexes and by use of our improved ant system algorithm. K p * , T i * , and T d * can be used in real-time control. This kind of controller is called the ASA-PID controller with incomplete derivation. To verify the performance of the ASA-PID controller, three different typical transfer functions were tested, and three existing typical tuning methods of PID controller parameters, including the Ziegler-Nichols method (ZN),the genetic algorithm (GA),and the simulated annealing (SA), were adopted for comparison. The simulation results showed that the ASA-PID controller can be used to control different objects and has better performance compared with the ZN-PID and GA-PID controllers, and comparable performance compared with the SA-PID controller.
文摘Controllable saturation reactors are widely used in reactive power compensation. The control system of controllable saturation reactor determines adaption speed, accuracy, and stability. First, an innovative type of controllable saturation reactor is introduced. After that the control system is designed, and a self-tuning algorithm in PID controller is proposed in the paper. The algorithm tunes PID parameters automatically with different error signals caused by varied loads in power system. Then the feasibility of the above algorithm is verified by Simulink module of Matlab software. The results of simulation indicate that the control system can efficiently reduce adaption time and overshoot.