In this research, the performance of the solar thermal powered systems (STPS) is analyzed with different models (without inserts, with inserts and with Nano fluids with different concentrations) and its impact on the ...In this research, the performance of the solar thermal powered systems (STPS) is analyzed with different models (without inserts, with inserts and with Nano fluids with different concentrations) and its impact on the Electric load in a residential/Institutional Electrical Distribution system. For this purpose, the electrical and solar thermal water heater is tested and validated. Solar thermal powered systems and its impact on the Institutional electrical distribution feeders are tested and compared with the energy efficiency (EE) and cost optimization. The goal of this paper is to analyze the impact of solar thermal energy on electrical energy consumption in the electrical distribution feeder level. The electrical system cost and energy consumptions are tabulated and observed that there is a considerable savings.展开更多
The design of hydro-bulge molds,able to provide hollow parts with special-shaped cross-sections,is still a pretty complicated task(especially for what concerns the design of the related hydraulic system and its“synch...The design of hydro-bulge molds,able to provide hollow parts with special-shaped cross-sections,is still a pretty complicated task(especially for what concerns the design of the related hydraulic system and its“synchronization”).In the present work,this task is addressed through the introduction of a new type of overhead cylinder hydraulic synchronization system,able to correct automatically any deviation from the optimal process.Using the AMESim software,the displacement synchronization curve of the piston rods of the two cylinders is obtained and it is verified that the system is able to implement an automatic deviation correction function by adjusting the bidirectional servo valve.A mathematical model for the synchronization system is presented,and the transfer function of the closed-loop control system is determined accordingly.The results show that the system response is generated at about 0.1∼0.2 s with the system reaching an equilibrium state at about 0.2 s.展开更多
文摘In this research, the performance of the solar thermal powered systems (STPS) is analyzed with different models (without inserts, with inserts and with Nano fluids with different concentrations) and its impact on the Electric load in a residential/Institutional Electrical Distribution system. For this purpose, the electrical and solar thermal water heater is tested and validated. Solar thermal powered systems and its impact on the Institutional electrical distribution feeders are tested and compared with the energy efficiency (EE) and cost optimization. The goal of this paper is to analyze the impact of solar thermal energy on electrical energy consumption in the electrical distribution feeder level. The electrical system cost and energy consumptions are tabulated and observed that there is a considerable savings.
基金projects of“The University Synergy Innovation Program of Anhui Province(GXXT-2019-004)Teaching Research Project of Anhui Education DepartmentScience and Technology Planning Project of Wuhu City(2021YF58).”。
文摘The design of hydro-bulge molds,able to provide hollow parts with special-shaped cross-sections,is still a pretty complicated task(especially for what concerns the design of the related hydraulic system and its“synchronization”).In the present work,this task is addressed through the introduction of a new type of overhead cylinder hydraulic synchronization system,able to correct automatically any deviation from the optimal process.Using the AMESim software,the displacement synchronization curve of the piston rods of the two cylinders is obtained and it is verified that the system is able to implement an automatic deviation correction function by adjusting the bidirectional servo valve.A mathematical model for the synchronization system is presented,and the transfer function of the closed-loop control system is determined accordingly.The results show that the system response is generated at about 0.1∼0.2 s with the system reaching an equilibrium state at about 0.2 s.