期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Quantitative Analysis of Heavy Metals in Water Based on LIBS with an Automatic Device for Sample Preparation 被引量:1
1
作者 胡丽 赵南京 +5 位作者 刘文清 孟德硕 方丽 王寅 余洋 马明俊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期699-703,共5页
Abstract Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were p... Abstract Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. 展开更多
关键词 SPECTROSCOPY automatic device sample preparation multiple enrichments quantitative analysis laser-induced breakdown spectroscopy
下载PDF
Performance of automated CT ASPECTS in comparison to physicians at different levels on evaluating acute ischemic stroke at a single institution in China 被引量:1
2
作者 Xiaochuan Huo Raynald +3 位作者 Hailan Jin Yin Yin Guangming Yang Zhongrong Miao 《Chinese Neurosurgical Journal》 CSCD 2021年第4期249-257,共9页
Background:Our aim was to evaluate the sensitivity and specificity of the automated computer-based Alberta Stroke Program Early CT Score(e-ASPECTS)for acute stroke patients and compare the result with physicians at di... Background:Our aim was to evaluate the sensitivity and specificity of the automated computer-based Alberta Stroke Program Early CT Score(e-ASPECTS)for acute stroke patients and compare the result with physicians at different levels.Methods:In our center,e-ASPECTS and 9 physicians at different levels retrospectively and blindly assessed baseline computed tomography(CT)images of 55 patients.Sensitivity,specificity,receiver-operating characteristic curves,Bland–Altman plots with mean score error,and Matthews correlation coefficients were calculated.Comparisons were made between the scores by physicians and e-ASPECTS with diffusion-weighted imaging(DWI)being the ground truth.Two methods for clustered data were used to estimate sensitivity and specificity in the region-based analysis.Results:In total,1100(55 patients×20 regions per patient)ASPECTS regions were scored.In the region-based analysis,sensitivity of e-ASPECTS was better than junior doctors and residents(0.576 vs 0.165 and 0.111,p<0.05)but inferior to senior doctors(0.576 vs 0.617).Specificity was lower than junior doctors and residents(0.883 vs 0.971 and 0.914)but higher than senior doctors(0.883 vs 0.809,p<0.05).E-ASPECTS had the best Matthews correlation coefficient of 0.529,compared to senior doctors,junior doctors,and residents(0.463,0.251,and 0.087,respectively).Conclusions:e-ASPECTS showed a similar performance to that of senior physicians in the assessment of brain CT of acute ischemic stroke patients with the Alberta Stroke Program Early CT score method. 展开更多
关键词 ASPECTS Computed tomography Ischemic stroke PHYSICIANS automatic device
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部